• 제목/요약/키워드: Smoke Spread

검색결과 125건 처리시간 0.05초

지하철 객차 화재발생시 피난 시간에 대한 연구 (A study of evacuation time in a subway carriage fire)

  • 김승렬;노재성;노경철;유홍선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1313-1318
    • /
    • 2007
  • Recently, the terror frequently has taken place for unspecified individuals as modern society is complicated. Especially, in case of a subway carriage fire as Daegu subway fire, because smoke spread path usually coincide with passenger's evacuation path, it will reduce visibility and can cause fatalities by asphyxiation. This study performs not only fire simulation with CFAST V6 but also evacuation simulation with EXODUS V4 for the purpose of taking measures for passengers's life safety in subway fire. As a result of evacuation simulation without fire, evacuation times are 36 s for EXODUS V4 and simple hand calculation, and when fire is occurred fire, 101 persons evacuated in 32 s. Therefore, a countermeasure of evacuation in subway carriage fire is required to repression of fire and emergency exit.

  • PDF

대심도 역사의 제연팬 용량에 따른 연기확산 영향 분석 (Analysis of Smoke Spread Effect Due to The Ventilation Capability in Underground Subway-Station)

  • 구인혁;장용준
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2012년도 춘계학술발표회 초록집
    • /
    • pp.424-427
    • /
    • 2012
  • 본 연구에서는 최근 증가하고 있는 대심도역사의 제연팬 용량에 따른 연기확산영향에 대하여 분석하였다. 시뮬레이션모델은 신금호 역사(5호선, 깊이 46m)를 대상으로 하였으며, 제연팬 용량에 따른 연기확산 영향을 분석 하였다. 현장조사 및 실측을 통하여 계측된 실제 역사의 제연팬에 관한 데이터를 화재시뮬레이션 조건으로 적용하였다. 역사전체를 해석 대상으로 하여 총 400만개의 격자를 사용하였으며, 제연팬 용량에 따른 연기확산 영향 비교를 위하여 화재 시나리오를 작성하여 Case별로 화재해석을 수행하였다. 계산 효율을 높이기 위하여 MPI병렬처리기법을 사용하였으며 해석코드는 LES(large eddy simulation) 기법을 주로 사용하는 FDS5 code를 사용하였다.

  • PDF

건축물 창호의 화재안전설계를 위한 실험적 연구 (An Experimental Study on the Fire Safety Design of Windows in Building)

  • 이병흔;진승현;한지우;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.10-11
    • /
    • 2018
  • In the building, the opening penetrates the wall and serves as a spreading channel for smoke and flame in case of fire. In Korea, more than 1,500 fire plume are generated annually, and the number has increased by about 30% over the past five years. Therefore, in the case of windows protecting the opening, fire protection performance is important to prevent the spread of fire. However, in Korea, the standard for window is not clear. In this study, fire tests (EN 13823) for windows were conducted in Korea, and then fire protection performance of windows was compared. As a result of the experiment, PVC windows showed a phenomenon that they could not withstand the temperature during the fire experiment, and AL windows showed a difference in the degree of cracking of the glass.

  • PDF

교통정체가 심한 도로터널에 대한 화재시 제연방식에 관한 연구 (The study of ventilation system during fire in road tunnel with bi-directional or congested unidirectional traffic)

  • 유지오;신현준;남창호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.474-479
    • /
    • 2008
  • The purpose of this paper is to estimate the fire safety in tunnels with bi-directional and/or congested unidirectional traffic where there may be people on both sides of the fire. Therefore, the spread and movement of smoke are simulated by Fire Dynamic Simulator code under different ventilation systems, longitudinal, semi-transverse, large port exhaust system. And as quantitative risk index, FED (Fractional Effective Dose) for each ventilation system are calculated and compared by existed code developed previous research.

  • PDF

터널 화재시 승객의 개인적 위험도 계산에 대한 확률적 접근 (The probability approach for the personal risk calculation of the passenger due to a tunnel fire)

  • 김동진;황영하;장용준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1246-1254
    • /
    • 2008
  • The land transportation is the most common way to transport passengers as well as freight among other mode of transportations and consequently more likely to be constructed for faster and convenient travel In this regard, the demand for tunnel constructions will be increasing and the safety inside the tunnel will be considered major concern more than ever. In this paper, we show probabilistic methodology to calculate the personal risk of each evacuee starting from a different location in a tunnel on fire. Passenger evacuation time and smoke spread time are both assumed to be continuous random variables having specific distributions. The evacuation of passengers at each location and the safety facilities inside the tunnel are also crucial factors to calculate the probability of death.

  • PDF

한·일 건축물 방화구획 기준 비교분석 (A Comparative Analysis on the building Fire Protection Standards of Korea and Japan)

  • 신영덕;한지우;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.4-5
    • /
    • 2019
  • Smoke and fire spread throughout the building as a result of problems in the fire prevention section of Uijeongbu Apartment Fire in 2015 and Jecheon Sports Center Fire in 2017 in Korea, causing a number of casualties. It is believed that the fire compartment standards need to be reviewed as the fire in recent buildings continues to show problems. In this study, a comparative analysis was conducted on the fire prevention zone standard with Japan to improve the fire compartmente standard in Korea.

  • PDF

지하철 내장재료의 재료특성에 따른 화재안전도 평가 (Fire safety evaluation of the subway car's interior materials)

  • 이덕희;정우성;이철규;김선욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.327-332
    • /
    • 2003
  • We investigated the fire characteristics of the subway electric car's interior materials and evaluated the safety of it. The testing methods are ISO 4589-2 for Limited Oxygen Index, ISO 5658-2 for surface flame spread, ISO 5660-1 for Heat Release Rate, ASTM E 662 for smoke density and BS 6852 Annex B.2 for gas toxicity. The materials of seven organization including KNR were tested. Most of the materials are under the levels of the foreign country's demand. We also reported the test methods of other countries and compared it to ours.

  • PDF

화재 시뮬레이션(FDS)을 이용한 커튼월 구조의 화재 확산에 관한 연구 (A Study on the Fire Spread through Curtain Wall System with Fire Simulations (FDS))

  • 송영주;구선환;김현진;박득진;박정민
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.31-37
    • /
    • 2012
  • 본 논문에서는 화재 시뮬레이션 프로그램을 이용하여 이중외피 구조 중 커튼월 구조의 화재 시 위험성을 일반적인 구조와 비교하여 보았다. 이를 위해 화재 시뮬레이션 프로그램(FDS)을 기반으로 한 PyroSim을 이용하여 가상의 5층 건축물로 모델링을 한 후 커튼월 구조를 적용하지 않은 모델과 커튼월 구조를 적용한 모델로 나누어 동일한 제반조건과 장소에서 화재가 발생 하도록 하였으며, 화재 특성을 확인하기 위해 연기거동, 가시거리, CO, $CO_2$의 농도를 비교 분석하였다. 그 결과, 커튼월 구조가 적용 되지 않은 경우보다 커튼월 구조가 적용된 경우 연기가 최상층에서부터 빠르게 채워져 밑의 층으로 점점 내려가는 현상을 확인 할 수 있었으며, 화재 시뮬레이션을 통해 화재 시 커튼월 구조의 위험성을 검증 하였다.

비닐장판 위에서 연소된 인화성 액체의 성장 특성과 탄화 패턴 (Growth Characteristics and Hydrocarbon Patterns of Flammable Liquid on a Vinyl Layer)

  • 조희수;최충석
    • 한국화재소방학회논문지
    • /
    • 제32권5호
    • /
    • pp.15-21
    • /
    • 2018
  • 본 연구에서는 인화성 액체가 비닐바닥에 뿌려져 화재가 발생되었을 때의 성장 특성 및 탄화 패턴 등을 해석하는데 있다. 아세톤은 화염이 착화되고 약 0.2 s 경과되었을 때 화염이 최성기에 도달하였다. 화염은 난류 패턴이며, 연기의 색상은 흰색이었다. 연소가 진행되는 하단은 층류 패턴이 확인되었고, 상단 부분은 난류 패턴이다. 연소 완료된 바닥은 희미한 포어 패턴을 나타냈다. 벤젠은 착화 후 약 0.6 s 경과하였을 때 강렬한 화염이 생성되었고, 길이는 약 50 mm로 측정되었다. 화염이 쇠퇴기로 접어들었을 때 불완전 연소에 의한 다량의 검은색 연기가 발생하였다. 연소가 완료된 바닥면의 탄화 패턴은 포어 패턴 및 스플래시 패턴 등이 확인되었다. 알코올은 착화되어 약 1.1 s 경과하였을 때 강렬한 화염이 형성되었다. 또한 인화성 액체가 고인 곳은 탄화 심도가 크게 형성되었고, 인화성 액체가 흘러간 곳의 경계면에서 탄화의 흔적이 확인되었다.

딥런닝 기반의 프레임 유사성을 이용한 화재 오탐 검출 개선 연구 (Fase Positive Fire Detection Improvement Research using the Frame Similarity Principal based on Deep Learning)

  • 이영학;심재창
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.242-248
    • /
    • 2019
  • 화염 및 연기 감지 알고리즘 연구는 다양한 모양, 빠른 확산 및 색상으로 인해 컴퓨터 비전에서 어려운 과제이다. 일반적인 센서 기반 화재 감지 시스템의 성능은 환경 요인(실내 및 화재발생 위치)에 따라 크게 제한된다. 이러한 문제를 해결하기위해 딥러닝 방법을 적용하였으며, 이것은 물체의 형상을 특징으로 추출하므로 비슷한 형상이 프레임내에 존재하면 오탐으로 검출 될 수 있다. 본 연구는 화재 오탐 검출 개선을 위해 딥런닝 사용 전과 후에 프레임 유사성을 이용하여 오탐을 줄이는 새로운 알고리즘을 제안한다. 실험결과 제안된 방법을 적용하여 화재 검출 성능은 유지를 하면서 오탐 부분이 최소 30% 까지 감소하는 결과를 얻을 수 있었다. 제안된 방법의 오탐 검출 성능이 뛰어나다는 것을 확인하였다.