• Title/Summary/Keyword: Smart patient

Search Result 201, Processing Time 0.03 seconds

Research on the impact factors of smartphone medical APP user experience - centered on Chinese medical APP (스마트폰 의료 앱 사용자 체험의 영향 요인에 관한 연구 - 중국 의료 앱을 중심으로)

  • Zhang, Zhuo;Jang, Chung-Gun
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.4
    • /
    • pp.125-133
    • /
    • 2021
  • With the advent of experience era, the user experience has attracted much attention in all walks of life. And the importance of user experience emphasize began to be emphasized. It analyzed the interfering factors of user experience of smart phone medical APP, and evaluated their relative importance. Then it made suggestions on the priority of medical APP development and provided reference for medical APP design optimization and service quality improvement. First of all, based on the related research about user experience theory, smartphone APP user experience and mobile medical APP, it summarized the user experience elements of smartphone medical APP. Secondly, 200 subjects in the 20-40 age group who chose smartphone download experience and used medical APP were surveyed to rate the effect of 18 factors. The results show that the factors such as product resources, medical advertising recommendations, doctor-patient interaction, emotional pleasure, easy to learn, and other factors have a significant impact on users' good experience when using app.

Application of digital software as a medical devices in dental clinic (치과 임상에서 디지털기반 소프트웨어 의료기기의 적용)

  • Woo, Keoncheol;Baik, SaeYun;Kim, Seong Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.4
    • /
    • pp.203-210
    • /
    • 2020
  • By facing the era of the 4th industrial revolution, personalized medical services for patients are expanding with the development of information and communications technology. With these changes, digital medical devices have begun to be used to support diagnosis, patient monitoring, and decision-making of diseases, and recently software medical devices for the purpose of preventing, managing, or treating disorders or diseases have become popular. The aim of this article is to understand the current concept and status of Software as a Medical Device (SaMD), which are actively being carried out in the United States, and to find out what fields can be applied in the future. In addition, it intends to find out the Korean domestic policy trends related to smart healthcare and find out the application of digital software as a medical devices that can be used in dental clinic to keep pace with the upcoming changes in the medical field.

Health-Care Providers' and Parents' Perspectives on Complementary Alternative Medicine in Children with Cancer in Indonesia

  • Susilawati, Dwi;Sitaresmi, Mei;Handayani, Krisna;Ven, Peter van de;Sutaryo, Sutaryo;Kaspers, Gertjan;Mostert, Saskia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3235-3242
    • /
    • 2016
  • Background: Complementary alternative medicine (CAM) use in children with cancer is widespread. Health-care providers (HCP) need to acknowledge and address this need. This study explored and compared perspectives on CAM of HCP and parents of young patients with cancer in Indonesia. Materials and Methods: We conducted a cross-sectional study using semi-structured questionnaires in HCP and parents of childhood cancer patients at an Indonesian academic hospital. Results: A total of 351 respondents participated: 175 HCP (response rate 80%) and 176 parents (response rate 80%). Parents were more likely than HCP to think that chemotherapy can cure cancer (80% compared to 69%, P=0.013). Nearly half of all parents (46%) and HCP (45%) doubted whether CAM can cure cancer. Parents were more likely than HCP to think that CAM can be helpful in childhood cancer treatment (54% compared to 35%, P=0.003). The most recommended CAM by HCP was self-prayer (93%). Reasons for recommending CAM were: hope for improvement of the child's condition (48%), patient wants to stop treatment (42%). Most discouraged CAM by HCP was by old-smart people (70%), the reasons being: lack of evidence for usefulness (77%), lack of CAM knowledge (75%). The proportion thinking that patients were unlikely to raise the CAM topic if they perceived that doctors were skeptical was higher in parents than in HCP (52% versus 1%) (P<0.001). Most HCP (71%) and parents (77%) acknowledged that their knowledge about safety and efficacy of CAM was inadequate (P=ns). The proportion that wanted to learn or read more about CAM was higher among parents than HCP (48% compared to 31%, P=0.002). Conclusions: HCP and parents have different perspectives on CAM use in children with cancer. HCP should enhance their CAM knowledge and encourage open communication about CAM with parents. If doctors' skepticism is perceived, parents are unlikely to raise CAM as a topic.

A Measurement System for Color Environment-based Human Body Reaction (색채 환경 기반의 인체 반응 정보 측정 시스템)

  • Kim, Ji-Eon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.2
    • /
    • pp.59-65
    • /
    • 2016
  • The result of analyzing the cognitive reaction due to the color environment has been applied to various filed especially in medical field. Moreover, the study about the identification of patient's condition and examination the brain activity by collecting the bio-signal based on the color environment is being actively conducted. Even though, there were a variety of experiments by convention the color environment using a light or LED color, it still has a problem that affects the psychological information. Therefore, our proposed system using a HMD (Head Mounting display) to provide a completed color environment condition. This system uses the BMS(Biomedical System) to collect the biometric information which responds to the specific color condition and the human body response information can be measured by the development the Memory and Attention test on Mobile phone. The collection of Biometric information includes electro cardiogram(ECG), respiration, oxygen saturation (Sp02), Bio-impedance, blood pressure will store in the database. In addition, we can verify the result of the human body reaction in the color environment by Memory and Attention application. By utilizing the reaction of the human body information that is collected thought the proposed system, we can analyze the correlation between the physiological information and the color environment. And we also expect that this system can apply to the medical diagnosis and treatment. For future work, we will expand the system for prediction and treatment of Alzheimer disease by analyzing the visualization data through the proposed system. We will also do evaluation on the effectiveness of the system for using in the rehabilitation program.

Smart Emotion Management System based on multi-biosignal Analysis using Artificial Intelligence (인공지능을 활용한 다중 생체신호 분석 기반 스마트 감정 관리 시스템)

  • Noh, Ayoung;Kim, Youngjoon;Kim, Hyeong-Su;Kim, Won-Tae
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.397-403
    • /
    • 2017
  • In the modern society, psychological diseases and impulsive crimes due to stress are occurring. In order to reduce the stress, the existing treatment methods consisted of continuous visit counseling to determine the psychological state and prescribe medication or psychotherapy. Although this face-to-face counseling method is effective, it takes much time to determine the state of the patient, and there is a problem of treatment efficiency that is difficult to be continuously managed depending on the individual situation. In this paper, we propose an artificial intelligence emotion management system that emotions of user monitor in real time and induced to a table state. The system measures multiple bio-signals based on the PPG and the GSR sensors, preprocesses the data into appropriate data types, and classifies four typical emotional states such as pleasure, relax, sadness, and horror through the SVM algorithm. We verify that the emotion of the user is guided to a stable state by providing a real-time emotion management service when the classification result is judged to be a negative state such as sadness or fear through experiments.

EEG Feature Engineering for Machine Learning-Based CPAP Titration Optimization in Obstructive Sleep Apnea

  • Juhyeong Kang;Yeojin Kim;Jiseon Yang;Seungwon Chung;Sungeun Hwang;Uran Oh;Hyang Woon Lee
    • International journal of advanced smart convergence
    • /
    • v.12 no.3
    • /
    • pp.89-103
    • /
    • 2023
  • Obstructive sleep apnea (OSA) is one of the most prevalent sleep disorders that can lead to serious consequences, including hypertension and/or cardiovascular diseases, if not treated promptly. Continuous positive airway pressure (CPAP) is widely recognized as the most effective treatment for OSA, which needs the proper titration of airway pressure to achieve the most effective treatment results. However, the process of CPAP titration can be time-consuming and cumbersome. There is a growing importance in predicting personalized CPAP pressure before CPAP treatment. The primary objective of this study was to optimize the CPAP titration process for obstructive sleep apnea patients through EEG feature engineering with machine learning techniques. We aimed to identify and utilize the most critical EEG features to forecast key OSA predictive indicators, ultimately facilitating more precise and personalized CPAP treatment strategies. Here, we analyzed 126 OSA patients' PSG datasets before and after the CPAP treatment. We extracted 29 EEG features to predict the features that have high importance on the OSA prediction index which are AHI and SpO2 by applying the Shapley Additive exPlanation (SHAP) method. Through extracted EEG features, we confirmed the six EEG features that had high importance in predicting AHI and SpO2 using XGBoost, Support Vector Machine regression, and Random Forest Regression. By utilizing the predictive capabilities of EEG-derived features for AHI and SpO2, we can better understand and evaluate the condition of patients undergoing CPAP treatment. The ability to predict these key indicators accurately provides more immediate insight into the patient's sleep quality and potential disturbances. This not only ensures the efficiency of the diagnostic process but also provides more tailored and effective treatment approach. Consequently, the integration of EEG analysis into the sleep study protocol has the potential to revolutionize sleep diagnostics, offering a time-saving, and ultimately more effective evaluation for patients with sleep-related disorders.

Automatic Electronic Medical Record Generation System using Speech Recognition and Natural Language Processing Deep Learning (음성인식과 자연어 처리 딥러닝을 통한 전자의무기록자동 생성 시스템)

  • Hyeon-kon Son;Gi-hwan Ryu
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.731-736
    • /
    • 2023
  • Recently, the medical field has been applying mandatory Electronic Medical Records (EMRs) and Electronic Health Records (EHRs) systems that computerize and manage medical records, and distributing them throughout the entire medical industry to utilize patients' past medical records for additional medical procedures. However, the conversations between medical professionals and patients that occur during general medical consultations and counseling sessions are not separately recorded or stored, so additional important patient information cannot be efficiently utilized. Therefore, we propose an electronic medical record system that uses speech recognition and natural language processing deep learning to store conversations between medical professionals and patients in text form, automatically extracts and summarizes important medical consultation information, and generates electronic medical records. The system acquires text information through the recognition process of medical professionals and patients' medical consultation content. The acquired text is then divided into multiple sentences, and the importance of multiple keywords included in the generated sentences is calculated. Based on the calculated importance, the system ranks multiple sentences and summarizes them to create the final electronic medical record data. The proposed system's performance is verified to be excellent through quantitative analysis.

Study for Automatic Exposure Control Technique (AEC) in SPECT/CT for Reducing Exposure Dose and Influencing Image Quality (SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰)

  • Yoon, Seok-Hwan;Lee, Sung-Hwan;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.33-38
    • /
    • 2014
  • Purpose Auto exposure control (AEC) in SPECT/CT automatically controls the exposure dose (mA) according to patient's shape and size. The aim of this study was to evaluate the effect of AEC in SPECT/CT on exposure dose reduction and image quality. Materials and Methods The model of SPECT/CT used in this study was Discovery 670 (GE, USA), Smart mA for AEC; and $^{99m}Tc$ as a radioisotope. To compare SPECT and CT images by CT exposure dose variation, we used a standard technique set at 80, 100, 120, 140 kVp, 10, 30, 50, 100, 150, 200, 250 mA, and AEC at 80, 100, 120, 140 kVp, 10-250 mA. To evaluate resolution and contrast of SPECT images, triple line phantom and flangeless Esser PET phantom were used. For CT images, noise and uniformity were checked by anthropomrphic chest phantom. For dose evaluation to find DLP value, anthropomorphic chest phantom was used and the CT protocol of torso was applied by standard technique (120 kVp, 100 mA) and AEC (120 kVp, 10-250 mA). Results When standard and AEC were applied, the resolutions at SPECT images with attenuation correction (AC) were the same as FWHM by center 3.65 mm, left 3.48 mm, right 3.61 mm. Contrasts of standard and AEC showed no significant difference: standard 53.5, 29.8, 22.5, 15.8, 6.0, AEC 53.5, 29.6, 22.4, 15.7, 6.1 In CT images, noise values at standard and AEC were 15.4 and 18.5 respectively. The application of AEC increases noise but the value of coefficient variation were 33.8, 24.9 respectively, obtaining uniform noise image. The values of DLP at standard and AEC were 426.78 and 352.09 each, which shows that the application of AEC decreases exposure dose more than standard by approximately 18%. Conclusion The results of our study show that there was no difference of AC in SPECT images based on the CT exposure dose variation at SPECT/CT images. It was found that the increased CT exposure dose leads to the improvement of CT image quality but also increases the exposure dose. Thus, the use of AEC in SPECT/CT contributes to obtaining equal AC SPECT images, and uniform noise in CT images while reducing exposure dose.

  • PDF

The Preliminary Results of Intensity-Modulated Radiotherapy for Tonsillar Cancer (편도암에 대한 세기조절방사선치료의 예비적 결과)

  • Park, Geum-Ju;Lee, Sang-Wook;Choi, Eun-Kyung;Kim, Jong-Hoon;Song, Si-Yeol;Youn, Sang-Min;Park, Sung-Ho;Park, Dong-Wook;Ahn, Seung-Do
    • Radiation Oncology Journal
    • /
    • v.27 no.3
    • /
    • pp.120-125
    • /
    • 2009
  • Purpose: We wanted to present the preliminary results of intensity-modulated radiotherapy (IMRT) for the treatment of tonsillar cancer. Materials and Methods: We retrospectively analyzed 12 patients who underwent IMRT for tonsillar cancer at Asan Medical Center between November 2002 and February 2007. Seven patients (58%) received definitive treatment, and five (42%) were treated in the postoperative setting. Among the definitively treated patients, 6 patients received cisplatin-based chemotherapy regimens. Simultaneous modulated accelerated radiation therapy (SMART) was used in nine patients. The prescribed dose was 72 Gy at 2.4 Gy/fraction for the definitively treated cases and 61.6 Gy at 2.2 Gy/fraction for the postoperative cases. The median follow-up period was 34 months. Results: All twelve patients completed treatment without interruption, and eleven showed a complete response. One patient had persistent loco-regional disease after treatment. The three-year estimates of loco-regional control, disease-free survival and overall survival were 91.7%, 91.7%, and 100%. The worst acute mucositis was Grade 1 in four patients, Grade 2 in five patients, Grade 3 in two patients and Grade 4 in one patient. Grade 3 xerostomia was observed in six patients. Conclusion: Intensity-modulated radiotherapy was shown to be a safe and effective treatment modality for tonsillar cancer. Further studies with a larger number of patients and a longer follow-up period are needed to evaluate the ultimate tumor control and late toxicity of IMRT for treating tonsillar cancer.

A Study on the Improvement for Medical Service Using Video Promotion Materials for PET/CT Scans (PET/CT 검사에서 동영상 홍보물을 통한 의료서비스 향상에 관한 연구)

  • Kim, Woo Hyun;Kim, Jung Seon;Ko, Hyun Soo;Sung, Ji Hye;Lee, Jeoung Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.30-35
    • /
    • 2013
  • Purpose: One of the current services, providing information to the patients and their guardians by using promotion materials induces positive responses and contributes to the improvement of the hospital reliability. Therefore, the objective of this study is to evaluate the effectiveness of audio visual materials, one of the means of promotion, as a way to give accurate medical information to resolve patient's curiosity about purpose and procedure of their examination and deplete complains about waiting which attributes negative effect to service quality assessment. Materials and Methods: 60 patients(mean age $53.97{\pm}12.24$, male : female = 26 : 34) who had $^{18}F-FDG PET/CT$ scan from July 2012 to August 2012 in Seoul Asan Medical Center were referred to the study. All of the patients having PET/CT scan were asked to watch an informative video material before the injection of radiopharmaceutical ($^{18}F-FDG$) and to fill in a questionnaire. Results: As a result of analyzing the contents of questionnaire, 52% of 60 patients had PET/CT scan for the first time and 72.4% of the patients read the PET/CT guidebook offered from their outpatient department or inpatient wards before their scan. After we searched the level of previous knowledge of the purpose and method of PET/CT scan, the patients answered 25.1% "know well", 34% "not sure", 40.9% "don't know" respectively. And 84.7% of the patients answered that watching the PET/CT guide video before the injection helps understanding what exam they were having and 15.3% of the patients did not. For the question asking ever the patients have experienced using our homepage or smart phone QR code to see the guide video before they visit out PET center, only 3.3% of them answered "yes". Lastly, the patients answered 60.1% "yes", 31.4% "so so" and 8.5% "no" respectively for the question asking whether watching the video makes the patients to fill the waiting time short. Conclusion: It is found that understanding of objective and method of the PET/CT scan and level of satisfaction was improved after the patients watched the guide video whether they had PET/CT scan before and read the PET/CT guidebook or not. Also, watching the video was effective for the reduction of perceptible waiting time. But while displaying the PET/CT guide video is useful for providing information about the scan and shortening the waiting time as one of the medical service, utilization of service was actually very poor because of the passive promotion and indifference of the patients about their examination. Therefore, from now on, it is necessary to construct the healthcare system which can be offered to more patients through the active promotion.

  • PDF