High-Temperature Structural Analysis on the Small-Scale PHE Prototype using Weld Properties (용접물성치를 고려한 소형 공정열교환기 시제품의 고온구조해석)

  • Song, Kee-Nam;Hong, Sung-Deok;Park, Hong-Yoon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.2
    • /
    • pp.1-6
    • /
    • 2012
  • A PHE (Process Heat Exchanger) in a nuclear hydrogen system is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature gas cooled Reactor) to the chemical reaction that yields a large quantity of hydrogen. A small-scale PHE prototype made of Hastelloy-X is being tested in a small-scale gas loop at Korea Atomic Energy Research Institute. Previous research on the high-temperature structural analysis of the small-scale PHE prototype had been performed only using parent material properties. In this study, high-temperature structural analysis using weld properties in weld zone was performed and the analysis results compared with the previous research.

Current Status and Prospect of Environmental friendly Farmstead Milk Processing in Korea (한국의 친환경적 목장형 유가공의 현황과 발전과제)

  • Bae, In-Hyu
    • Korean Journal of Organic Agriculture
    • /
    • v.18 no.2
    • /
    • pp.155-176
    • /
    • 2010
  • This study was conducted to research the status, history and prospects of farm scale milk processing and to develop a management strategy for small scale milk process plant in Korea. Also it aims to provide ways to apply it so as to vitalize the farm made milk products market practically. This study was also treats the practical development of dairy farm school programs through the farm scale milk processing. Farm-scale milk plant (FMP) should be some of the ideas to develop small scale and using the resources according to the local features, limited expanding in regional market, produce by consumers order amounts, management policy will be transferred organic dairy farm. A few policy suggestions to put FMP system of financial support would not from beginner, it is better to settled FMP system by government or co-operation group in practical support programs were proposed. What the state needs to do through direct involvement were to put efforts at demand expansion on FMP system products, to certificate and safety the farm made milk products marketing system settings, to build more variation chance of the milk products. What was more important, however, was support policy, to create the network of FMP market and to develop of training program contents for each FMP operation unit. The ideal FMP model for the development of Dairy Farming proposed in this research will be applied as a relevant reference in managing and realizing environmental friendly and sustainable dairy industry at the national level.

Single-Phase Multilevel PWM Inverter Based on H-bridge and its Harmonics Analysis

  • Choi, Woo-Seok;Nam, Hae-Kon;Park, Sung-Jun
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1227-1234
    • /
    • 2015
  • The efficient electric power demand management in electric power supply industry is currently being changed by distributed generation. Meanwhile, small-scale distributed generation systems using renewable energy are being constructed worldwide. Several small-scale renewable distributed generation systems, which can supply electricity to the grid at peak load of the grid as per policy such as demand response programs, could help in the stability of the electric power demand management. In this case, the power quality of the small-scale renewable distributed generation system is more significant. Low prices of power semiconductors and multilevel inverters with high power quality have been recently investigated. However, the conventional multilevel inverter topology is unsuitable for the small-scale renewable distributed generation system, because the number of devices of such topology increases with increasing output voltage level. In this paper, a single-phase multilevel inverter based on H-bridge, with DC_Link divided by bi-directional switches, is proposed. The proposed topology has almost half the number of devices of the conventional multilevel inverter topology when these inverters have the same output voltage level. Double Fourier series solution is mainly used when comparing PWM output harmonic components of various inverter topologies. Harmonic components of the proposed multilevel inverter, which have been analyzed by double Fourier series, are compared with those of the conventional multilevel inverter. An inverter prototype is then developed to verify the validity of the theoretical analysis.

Development of Guidelines for Physical Security Systems of Small-scale Water Supplies (소규모수도시설의 보안시설 설치지침 개발)

  • Kim, Youngil;Yi, Sangjin;Lee, Doojin;Lee, Wontae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.723-730
    • /
    • 2013
  • Due to the event of hazardous chemical injection into a water storage tank in Hongseong, Chungcheongnam-do in 2012, the Korean Ministry of Environment has revised the enforcement rules of the Water Supply and Waterworks Installation Act to install surveillance equipments such as closed-circuit television(CCTV). However, the enforcement rules still do not provide concrete provision for installation of physical security equipments. Thus we studied vulnerability of small-scale water supplies in Korea and developed guidelines for the physical security system of the facilities. The guidelines include selection and recommendation of the physical security approaches and measures to detect, delay and response to the presence of an intruder in small-scale water supplies. The security features include protection utilities(e.g., fencing and fence topping), exterior intrusion detectors and alarms, locks and padlocks, surveillance utilities(e.g., CCTV), and others.

Estimates of Economies of Scale and Economies of Density in the Ocean Shipping Industry (외항해운산업의 비용함수 추정 : 규모 및 밀도의 경제성 분석을 중심으로)

  • 하영석
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.2
    • /
    • pp.157-172
    • /
    • 1996
  • The long-existed licence system which has acted as one of the strong barriers to entry in the ocean shipping market in Korea is supposed to repeal in the near future. As a result, competition among the different sizes of firms which are operating under regional shield by means of the licence will be intensified. The main objective of this paper is to estimate the degree of economies of scale and economies of density for various firm sizes. For the successful estimation of economies scale and economies of density, translog cost models are developed and estimated through SURE technique which was suggested by Zeller (1963). The major findings are as follows ; All shipping firms in the sample exhibit economies of scale and density. Even small size shipping firms under licence system, they show substantial economies of scale contrary to the wide-known idea that small-size firms are subject to diseconomies of scale. For the ranked firm sizes according to owned deadweight tons, the degree of economies of scale decreases as the firm sizes are larger and larger. The degree of economies of density moderately declines from the smallest to the firm size of 30-60 thousand deadweight tons and sharply rise thereafter. And the large shipping firms with over half-million deadweight tons exhibit high economies density compared to other sizes of firm. If follows that the larger firms have great advantage in competition if the licence system is abolished.

  • PDF

Modified Similitude Law for Pseudodynamic Test on Small-scale Steel Models (철골 축소모헝의 유사동적실험을 위한 수정된 상사법칙)

  • Kim, Nam-Sik;Kwak, Young-Hak;Chang, Sung-Pil
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.6
    • /
    • pp.49-57
    • /
    • 2003
  • Although there are several experimental techniques to evaluate the seismic behavior and performance of civil structures, small-scale models in mast of physical tests, instead of prototypes or large-scale models, would be used due to a limitation on capacities of testing equipments. However, the inelastic seismic response prediction of small-scale models has some discrepancies inherently because the similitude law is generally derived in the elastic range. Thus, a special attention is required to regard the seismic behavior of small-scale models as one of prototypes. In this paper, differences between prototypes and small-scale models pseudodynamically tested on steel column specimens are investigated and an alternative to minimize them is suggested. In general, small-scale models could have the distorted stiffness induced from some experimental errors on test setup, steel fabrication and so on. Therefore, a modified similitude law considering both a scale factor for length and a stiffness ratio of small-scale model to prototype is proposed. Using the modified similitude law to compensate experimental errors, the pseudodynamic test results from modified small-scale model are much improved as compared with the results of prototype. According to the pseudodynamic test results of small-scale steel models, it can be concluded that the modified similitude law proposed could be effective in simulating the seismic response of prototype structures.

Methed for the Passaging of Microcarrier Cultures to a Production Scale for Producing High Titre Disabled Infectious Single Cycle-Herpes Simplex virus Type-2

  • Zecchini, Tracey-Ann;Wright, Paul-Andrew;Smith, Rodney-John
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.2
    • /
    • pp.118-122
    • /
    • 2000
  • A comlementary call line CR2 is curretly used to propagte the Disabled Infectious Single Cycle Herpes Simplex Virus Typee2 (DISC HSV-2) on a small Iaboratory scale upto 15 L. These cultures are initiated by passaging the cells from roller bottle cultures. Whilst this is suitable for the laboratory scale it is totally impractical for use in seeding an industrial manufacturing scaled version of the culture. It is paramount to have a robust system for passaging cells from a small microcarrierier culture system to a larger one by a serial subculturing regime. Here we report on the successes we have had in our laboratory in scaling up out production system for the DISC HSV-2 from small 1-L cultures to a 50-L vessel with the maintenance of the viral productivity. Ease of use, reproducibility and the need to minimise overall production time were factors which were taken into consideration whils developing our procedures. We were aware of the need to keep a production train simple and as short as possible as this was the amall scale study for an envisaged manufacturing process.

  • PDF

Analytical study on seepage behavior of a small-scale capillary barrier system under lateral no-flow condition

  • Byeong-Su Kim
    • Geomechanics and Engineering
    • /
    • v.35 no.1
    • /
    • pp.13-27
    • /
    • 2023
  • The model production for large-scale (lateral length ≥ 2.0 m) capillary barrier (CB) model tests is time and cost-intensive. To address these limitations, the framework of a small-scale CB (SSCB) model test under the lateral no-flow condition has been established. In this study, to validate the experimental methodology of the SSCB model test, a series of seepage analyses on the SSCB model test and engineered slopes in the same and additional test conditions was performed. First, the seepage behavior and diversion length (LD) of the CB system were investigated under three rainfall conditions. In the seepage analysis for the engineered slopes with different slope angles and sand layer thicknesses, the LD increased with the increase in the slope angle and sand layer thickness, although the increase rate of the LD with the sand layer thickness exhibited an upper limit. The LD values from the seepage analysis agreed well with the results estimated from the laboratory SSCB mode test. Therefore, it can be concluded that the experimental methodology of the SSCB model test is one of the promising alternatives to efficiently evaluate the water-shielding performance of the CB system for an engineered slope.

A Study on the Cuf-off Speed of Small-scale Wind Power System for Battery Charging (배터리 충전을 위한 소형풍력 발전 시스템의 한계 풍속에 관한 연구)

  • Ku, Hyun-Keun;Lee, Hyung-Uk;Kim, Jang-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.484-489
    • /
    • 2014
  • Three phase PWM(Pulse Width Modulation) converter of the small-scale wind power system is able to charge battery under the rated wind speed regions. However, it is impossible to control output power of converter at the over win speed region because back-EMF(Electro Motive Force) of PMSG(Permanent Magnet Synchronous Generator) is higher than the battery terminal voltage of PMSG is reduced. However, the cut-off wind speed exists although battery charging algorithm is implemented by flux weakening control method. Therefore, this paper performs analysis of other factors which affects limitation wind speed. The validity of the analysis are verified through simulation.

Simulation Performance of WAVE System with Combined DD-CE and LMMSE Smoothing Scheme in Small-Scale Fading Models

  • Seo, Jeong-Wook;Kwak, Jae-Min;Kim, Dong-Ku
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.3
    • /
    • pp.281-288
    • /
    • 2010
  • This paper investigates the performance of IEEE 802.11p wireless access in vehicular environments (WAVE) system in small-scale fading models reported by Georgia Institute of Technology (Georgia Tech). We redesign the small-scale fading models to be applied to the computer simulation and develop the IEEE 802.11p WAVE physical layer simulator to provide the bit error rate and packet error rate performances. Moreover, a new channel estimator using decision directed channel estimation and linear minimum mean square error smoothing is proposed in order to improve the performance of the conventional least square channel estimator using two identical long training symbols. The simulation results are satisfactorily coincident with the scenarios of Georgia Tech report, and the proposed channel estimator significantly outperforms the conventional channel estimator.