• 제목/요약/키워드: Small performance hall

검색결과 34건 처리시간 0.023초

D 문화체육센타 소공연장의 음향특성에 관한 연구 (An Study on the Acoustics Characteristics of D's Small Performance Hall)

  • 한경연;서정석;김재수
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2004년도 추계학술대회 논문집
    • /
    • pp.367-371
    • /
    • 2004
  • The purpose of this research is furnishing of basic material for acoustic planning hereafter, after understanding the acoustic merits and demerits through measuring and analyzing on room acoustic of small performance hall. As the result of the measurement, those physical evaluation indexes such as SPL, RT, EDT, $D_{50}$, $C_{80}$, RASTI have being kept the satisfiable acoustic condition for the service of performance hall. Therefore, as small performance hall is regarded as equipped with sufficient volume of sound, reverberatory feeling and diffusive feeling, it judges as an excellent performance place, also it is considered that it could be utilized as a useful material when design so similar performance hall, hereafter.

  • PDF

가청화를 이용한 소규모 다목적 홀의 음향 성능평가에 관한 연구 (A Study about Appraise on Acoustic Performance of small-scaled Multi-Purpose Hall, using Auralization)

  • 주덕훈;윤재현;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.148-152
    • /
    • 2007
  • In recent days, on account of the cultural development and the improvement of citizen's consciousness level, it is the real situation that the construction of small-scaled Multi-Purpose Hall where various cultural events could be performed, is on increasing. However, since the most of Multi-Purpose Hall had been designed and built up without any consideration on Acoustic Factor, many problems are on occurring thereat. Since those small-scaled Multi-Purpose Hall have been mostly used with the finishing material which contains a high degree of Acoustic Absorption indiscreetly, both diffusion and reflection of sound are not establishing properly, and because thereverberation of sound is very low, in case of musical performance by musical instrument, its sound hears too arid and stiff, there occurs some acoustic defect such as it becomes difficult for music appreciation with sufficient timbre, so that the capability improvement on the matter is urgently requiring situation. Therefore, this Study has tried to seize the satisfaction level about the small-scaled Multi-Purpose Hall after betterment of the acoustic performance by appraise the acoustic condition of the Hall, using Auralization Technique that can experience Virtual Acoustic Field regarding to the small-scaled Multi-Purpose Hall as its object. It is deemed that such research result could be practically used as the useful material which enables to bring a reduction effect of construction cost as well asenhancement of the acoustic performance through its presupposition?control on the acoustic problem when construction or renovation of other similar small-scaled Multi-Purpose Hall in the future.

  • PDF

음향성능 개선을 위한 소규모 다목적홀의 건축음향성능 평가 (Evaluation on Architectural Acoustic Performance of Small-scaled Multipurpose Hall for Improvement of Acoustic Performance)

  • 윤재현;주덕훈;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.226-230
    • /
    • 2007
  • In case of domestic performance hall, it is real situation that the demand of multipurpose hall that accommodative a lecture, gathering activity, drama and concert than a professional performance hall such as opera house, is on increasing. Accordingly, since such multipurpose hall, in view of its characteristics, is emphasizing the clearness of sound, also it requiring the repletion or abundance of sound simultaneously, it could be said that the sufficient examination and plan with regard to the architectural acoustics design is indispensable. However, since most of multipurpose hall has ever been designed and constructed without any consideration on an acoustic factor, many problem points are generating. Standing on such viewpoint, this Research has measured the physical acoustic characteristics about the small-scaled multipurpose hall recently built without any acoustic consideration, and through the above, tried to grasp the acoustic defect and controversial point thereof. It is deemed that such study result could be utilized as an important material for improvement the acoustic performance of the multipurpose hall.

  • PDF

소규모 다목적 홀의 음향성능 개선 사례 (Case study on the Improvement of Acoustic performance for Small Multipurpose Hall)

  • 주덕훈;윤재현;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.236-241
    • /
    • 2007
  • Recently, in accordance with the cultural progress and the improvement of citizen's consciousness level, it is the real situation that the construction of small-scaled Multi-Purpose Hall where various cultural events could be performed, is on increasing. However, because the most of Multi-Purpose Hall had been designed and built up without any consideration on Acoustic Factor, many problems are on occurring thereat. Because those small-scaled Multi-Purpose Hall have been mostly used with the finishing material which contains a high degree of Acoustic Absorption indiscreetly, both diffusion and reflection of sound are not establishing properly, and since the reverberation of sound is very low, in case of musical performance by musical instrument, its sound hears too arid and stiff, there occurs some acoustic defect such as it becomes difficult for music appreciation with sufficient timbre, so that the capability improvement on the matter is urgently requiring situation. On this viewpoint, this Research has caught the Authenticity of the forecasted value and actually measured value using Acoustic Simulation on the subject of the small-scaled Multi-Purpose Hall, and then intended to propose the optimum acoustic condition on the basis of the Authenticity. As the result, it could be designed a Multi-Purpose Hall equipped with the satisfactory acoustic performance compare with the time before improvement, so that it is considered that such research result could be practically used as the fundamental material when design for other similar small-scaled Multi-Purpose Hall in the future.

  • PDF

Development of 10-mN Class Hall Thruster and Its Performance Optimization through Numerical Analysis

  • Seon, Jong-Ho;Park, Jae-Heung;Lee, Jong-Sub;Lim, Yu-Bong;Seo, Mi-Hui;Choe, Won-Ho;Lee, Hae-June
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.550-552
    • /
    • 2008
  • A small hall thruster with a thrust of about 10 mN and a specific impulse of about 1500 s is being developed with an intent to control or maintain the orbits of small satellites. The total mass, consumed electric power and efficiency of the thruster are approximately 10 kg, 300W and 30%, respectively. The thruster system consists of a hall thruster with a cylindrical cross section, a power processing unit and a Xenon(Xe) gas feed system. Laboratory examination of the thruster performance finds that the thruster meets the design specification.

  • PDF

강의전용 공간으로 리모델링된 대학 소공연장의 음향성능 개선 및 변화 : W대학의 사례를 바탕으로 (Improvement and Change of Acoustic Performance of University Small Hall Remodeled as Exclusive for Lecture Room : Based on the case of the W University)

  • 김민주;김재수
    • 교육녹색환경연구
    • /
    • 제19권2호
    • /
    • pp.21-31
    • /
    • 2020
  • 본 연구는 교육품질에 직·간접적인 영향을 미치는 다양한 환경요소 중 음환경에 대한 내용을 W대학 인문대 소공연장의 리모델링 사례를 통해 분석하고자 하였다. 본 연구의 대상인 W대학 인문관의 소공연장은 강의전용 공간으로 리모델링하기에 앞서 적당한 울림이 필요한 공연장과 상대적으로 음성의 명료성이 중요한 강의실의 음향성능 차이를 인지하고 강의전용 공간에 적합한 실내 음환경을 조성하고자 하였다. 따라서 본 연구에서는 리모델링 전 음향성능 측정, 음향 시뮬레이션을 통한 마감재료 변경안 제시, 리모델링 후 음향성능 측정의 단계를 거쳐 리모델링에 따른 강의전용공간의 음향성능 개선안의 사례를 제시하고자 하였다. 이러한 과정은 추후 마감재 변경을 통한 강의전용 공간 등 교육공간에 적합한 실내 음향성능 확보의 사례로 활용될 수 있을 것으로 사료된다.

소형위성용 저전력 홀 추력기의 성능 비교 연구 (Comparison Study of the Low Power Hall Thrusters Performance)

  • 강성민;김연호;정연황;선종호;이종섭;서미희;최원호
    • 한국항공우주학회지
    • /
    • 제39권2호
    • /
    • pp.195-200
    • /
    • 2011
  • 소형 지구관측위성의 궤도 보정을 위한 저전력 홀 추력기를 개발하였다. 원통형 홀 추력기의 성능 특성을 파악하기 위해 원통형 홀 추력기과 고리형 홀 추력기를 제작하여 시험을 수행했고 그 결과를 비교 분석하였다. 원통형 추력기는 채널 내경에 따른 성능 변화를 보기 위해 28 mm, 50 mm 두 종류로 제작되었다. 다양한 방전 조건에서 추력과 이온 에너지, 이온 전류를 측정하였다. 결과는 원통형 추력기가 고리형 추력기에 비해 연료 효율과 전압 효율에서 더 뛰어나고, 전류 효율에서는 떨어짐을 보였다.

Double-PLL을 이용한 홀 센서 기반 PMSM 제어의 위치 추정 성능 개선 (Performance Improvement of Position Estimation by Double-PLL Algorithm in Hall Sensor based PMSM Control)

  • 이송철;정영석
    • 전력전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.270-275
    • /
    • 2017
  • This paper proposes a double-phase-locked-loop (PLL) to improve the performance of position estimation in hall sensor-based permanent magnet synchronous motor control. In hall sensor-based control, a PLL is normally used to estimate the rotor position. The proposed Double-PLL consists of two PLLs, including a reset type integrator. The motor control is more accurate and has better performance than conventional PLL, such as a small estimated position ripple. The validity of the proposed algorithm is verified by simulations and experiments.