• Title/Summary/Keyword: Small Hall

Search Result 182, Processing Time 0.029 seconds

Structure and Electrical Properties of PbTe Thin Film According To The Substrate Temperature (기판온도에 따른 PbTe 박막의 구조 및 전기적 물성)

  • Lee, Hea-Yeon;Choi, Byung-Chun;Jeong, Jung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.184-188
    • /
    • 1999
  • PbTe thin films of high quality were deposited on HF-treated Si(100) substrates at various substrate temperature by pulsed laser deposition technique. XRD patterns showed that PbTe layers were well-crystallized to a cubic phase with (h00) preferred orientation with the substrate temperature up to $300^{\circ}C$. PbTe films could not form at substrate temperature above $400^{\circ}C$ because of reevaporation of the Pb. According to AFM image, the surface of films was composed of small granular crystals and flat matrix. According to the increase of substrate temperature, the grain size at film surface becomes larger. By Hall-effect measurement, the carrier concentration and Hall mobility of n-type PbTe films grown by $T_{sub}=300^{\circ}C$ were $3.68{\times}10^{18}cm^{-3}$ and $148\;cm^2/Vs$, respectively.

  • PDF

Study of the Dormitory Architecture of Governmental Secondary Schools in the Japanese Colonial Era (일제 강점기 관립 중등학교 기숙사 건축에 관한 연구)

  • Lee, Jeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5355-5362
    • /
    • 2014
  • This study reviewed the planning characteristics of dormitories for secondary schools in the Japanese Colonial Era by analyzing the architectural drawings collected by the National Archives of Korea. The dormitory was one of the essential facilities in secondary schools but there have been few studies in this area. The analysis items were the site plan and the planning characteristics of student bedrooms, dining hall, and supervisor's area, which were the main elements of the dormitory. The results of this study were summarized as follows. 1) Generally, the dormitory area was placed in the rear of buildings for teaching with a close connection. 2) The student bedroom wings were laid out in parallel to the south as a rule making the typical site plan pattern for a dormitory, whereas the other parts of dormitory, such as the dining hall and supervisor's area were placed in the site conditions. 3) Generally, the unit plans of bedrooms for Korean schools were the ondol type and were small in size, whereas those for Japanese were the tatami type and large in size with separate study and sleeping areas. 4) The dining hall annex was made up of a dining hall and kitchen-bathroom area in general. For Japanese schools, the school store area was added to these areas. The typical shapes of dining hall plans were narrow and long with an adjacent corridor, so the overall plan of the dining hall annex was like that of a single-corridor type block plan. 5) The supervisor's area was a smaller part of the dormitory but it was considered to be a symbolic part of the whole dormitory in site planning and design.

The Effects of spatial features on visitor attitudes at exhibition hall (전시홀 공간특성이 참관객 태도에 미치는 영향)

  • Duan, Mingming;Kim, Young Sun;Kim, Bong Seok
    • Korea Science and Art Forum
    • /
    • v.29
    • /
    • pp.89-100
    • /
    • 2017
  • This research aims to identify spatial features of exhibition hall for trade fair and establish a theoretical model on the effects of these features on the visitor attitudes. Also, it seeks to make suggestions on the service for exhibition environment or marketing activities through empirical analysis. The survey for this research was conducted for one week from Oct. 28 to Nov. 5, 2016 at COEX in Seoul. The 320 questionnaires were distributed to the visitors of the survey period, and all of the questionnaires were returned. Excluding those considered meaningless due to a small number of answered questions, a total of 303 samples were used for empirical analysis. The empirical analysis was conducted through SPSS 24.0. The results showed that each element of spatial features of the exhibition hall has significant effects on the visitor intuitive attitude. On the other hand, only Aesthetic and Convenience of spatial features of the exhibition hall has significant effects on the visitor conative attitude As above, this research conducted empirical researches on the effects of spatial features on visitor attitudes at exhibition hall to provide guidelines for establishing strategic management schemes of exhibition space that provide more convenient and pleasant environment. Also, this research aims to suggest development directions for organizer to provide quality service and environment, turning them into comfortable spaces that communicate with the visitors.

Development of a micro BLDC Motor and Sensorless Drive (초소형 BLDC모터 및 센서리스 구동모듈 개발)

  • Choi, J.H.;Jung, I.S.;Kim, J.H.;Hur, J.;Sung, H.G.;Cho, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1444-1446
    • /
    • 2005
  • Recently most machineries have been small size and mobile type. And human body insertion type endoscope and micro robot technology has been developed. Then the motors used in this field are developed in micro size such as about 2mm in diameter. The structure of this motor is similar to a general brushless DC(BLDC) motor but because of small size there is no position sensor such as hall sensor. In this paper, a design and fabrication result of an ultra-small brushless DC motor is presented. This motor is designed to 3-phase coreless winding and operated with sensor-less type driver. Test results confirmed the feasibility of the proposed motor drive system design.

  • PDF

Goodenss of Fit Test on Density Estimation

  • Kim, J.T.;Yoon, Y.H.;Moon, G.A.
    • Communications for Statistical Applications and Methods
    • /
    • v.4 no.3
    • /
    • pp.891-901
    • /
    • 1997
  • The objective of this research is to investigate the problem of goodness of fit testing based on nonparametric density estimation with a data-driven smoothing parameter. The small and large smaple properties of the proposed test statistic $Z_{mn}$ are investigated with the minimizer $\widehat{m}$ of the estimated mean integrated squared error by the Diggle and Hall (1986) method.

  • PDF

The Site Plan and the Design of Daeungjeon(Main Buddhist Hall) of Songgwangsa Temple Seen by Yi Ok, in the Late Joseon Period (이옥이 본 조선 후기 완주 송광사의 가람배치와 대웅전의 구조)

  • Tahk, Kyung-Baek
    • Journal of architectural history
    • /
    • v.26 no.2
    • /
    • pp.43-52
    • /
    • 2017
  • While going into troops for writing in the vignette style(小品文) in opposition to the Classical Chinese(古文), Yi Ok stopped by Songgwangsa Temple in Wanju. The things he felt during this stop were recorded in the Temple Chapter("寺觀") written in 1795. Therefore, the present dissertation evaluates the Songgwangsa Temple of the time based on this Temple Chapter. Data in the Temple Chapter draws attention to the fact that it records the layout of the temple in detail. Thus the study was able to confirm the change in layout by reviewing relevant records about repair. This reveals that the form of layout in general has been maintained although there were changes involving the relocation of the buildings and their names. Furthermore, the original Buddhist building was changed to a quarter for the monks. Also, in terms of layout after the 18th century, there are frequent name changes of the Myeongbujeon(冥府殿) and Nahanjeon(羅漢殿). After two repairs, in order to find the appearance of a Daeungjeon(Main Buddhist hall) with a two-storied structure of five bays at the front, the study evaluated the Geugnakjeon at Muryangsa Temple and the Daeungbojeon at Magoksa Temple. The evaluation revealed that the 'Jeol' used in the Temple Chapter were small pillars erected on a ridgepole just like the Geugnakjeon at Muryangsa Temple, and that the angle rafters were installed to corner bays in rectangular form. The intellectual Yi Ok left behind invaluable architectural data that reveals the Songgwangsa Temple of the 18th century.

Estimated Blood Pressure Algorithm of Wrist Wearable Pulsimeter Using by Hall Device (홀소자를 이용한 손목착용 맥진기의 혈압추정 알고리즘)

  • Ahn, Myung-Cheon;Cho, Jong-Gu;Son, Il-Ho;Lee, Sang-Suk;Kim, Kuen-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.3
    • /
    • pp.106-113
    • /
    • 2010
  • In order to get the precise blood pressure and pulse number in the cuffless status, the wrist wearable pulsimeter with a portable and small size apparatus using by Hall device is developed. The regression analysis of the pulse wave measured by the testing product of pulsimeter is conducted two equations of the blood pressure algorithm. The estimated values of blood pressure obtained by the cuffless pulsimeter during 5 s are compared with the practical values measured by electronic or mercury liquid blood pressure meters. The standard deviation of the estimated value and the practical value for the high blood pressure and the low blood pressure were 12.1 and 5.9, respectively, which have the neighborhood values of BP International Standard. The detail analysis of a pulse wave measured by cuffless wrist wearable detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of blood pressure applying for oriental medical apparatus like as the wrist wearable pulsimeter.

Effect of Work Function of Zn-doped ITO Thin Films on Characteristics of Silicon Heterojunction Solar Cells (실리콘 이종접합 태양전지 특성에 대한 Zn 도핑된 ITO 박막의 일함수 효과)

  • Lee, Seung-Hun;Tark, Sung-Ju;Choi, Su-Young;Kim, Chan-Seok;Kim, Won-Mok;Kim, Dong-Hhwan
    • Korean Journal of Materials Research
    • /
    • v.21 no.9
    • /
    • pp.491-496
    • /
    • 2011
  • Transparent conducting oxides (TCOs) used in the antireflection layer and current spreading layer of heterojunction solar cells should have excellent optical and electrical properties. Furthermore, TCOs need a high work function over 5.2 eV to prevent the effect of emitter band-bending caused by the difference in work function between emitter and TCOs. Sn-doped $In_2O_3$ (ITO) film is a highly promising material as a TCO due to its excellent optical and electrical properties. However, ITO films have a low work function of about 4.8 eV. This low work function of ITO films leads to deterioration of the conversion efficiency of solar cells. In this work, ITO films with various Zn contents of 0, 6.9, 12.7, 28.8, and 36.6 at.% were fabricated by a co-sputtering method using ITO and AZO targets at room temperature. The optical and electrical properties of Zn-doped ITO thin films were analyzed. Then, silicon heterojunction solar cells with these films were fabricated. The 12.7 at% Zn-doped ITO films show the highest hall mobility of 35.71 $cm^2$/Vsec. With increasing Zn content over 12.7, the hall mobility decreases. Although a small addition of Zn content increased the work function, further addition of Zn content over 12.7 at.% led to decreasing electrical properties because of the decrease in the carrier concentration and hall mobility. Silicon heterojunction solar cells with 12.7 at% Zn-doped ITO thin films showed the highest conversion efficiency of 15.8%.

Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the Photoplethysmograph (홀센서 집게형 맥진기와 심전도-용적맥파계를 이용한 한양방 융합용 환자감시장치 개발연구)

  • Lee, Dae-Hui;Hong, Yu-Sik;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.135-143
    • /
    • 2013
  • The clip-type pulsimeter equipped with a Hall sensor has a permanent magnet attached in the "Chwan" position to the center of a radial artery. The clip-type pulsimeter is composed of a hardware system measuring voltage signals. These electrical bio-signals display pulse rate, non-invasive blood pressure, respiratory rate, pulse wave velocity (PWV), and spatial pulse wave velocity (SPWV) simultaneously measured by using the radial artery pulsimeter, the electrocardiograph (ECG), and the photoplethysmograph (PPG). The findings of this research may be useful for developing a oriental-western biomedical signal storage device, that is, the new and fusion patient monitor, for a U-health-care system.

A Study on the Improvement of Common Facilities in the Rural Village (농촌마을 공동시설 개선 방향 설정에 관한 연구)

  • Jo, Sun-Jae;Im, Seung-Bin;O, Hwi-Yeong
    • Journal of Korean Society of Rural Planning
    • /
    • v.2 no.2
    • /
    • pp.37-44
    • /
    • 1996
  • The main aim of this study is to propose the improvement guidelines for the rural communit;- facilities(short as RCFs) in the village level. 28 villages were selected in consideration of the travelling distance to the nearest city, farming types and percentage of farm to total land. Through the analyses of the physical conditions and utilizing practices of RCFs in case villages, the tentative improvement guidelines were finally formulated. The major results of the study were summarized as follows ' 1. Most villagers thought the village hall and Jungjamok(Korean-style outdoor rest point) being centrally located, which was reflected in their high satisfaction with the accessibility to RCFs.However, they evaluated that above two places were too small and old for normal use, so set forth their views of high dissatisfaction on the scale of RCFs, 2. Analyses results of the survey in the study showed the ranking order of service level of RCFs as following; the village hall l rest building for the aged 1 rural-pocket park 1 village store / playground.And the need for cultural function was much more highly expressed than merely meeting function. 3. Considering together with the analysis results of this study and the related referencing guidelines, it is proposed to introduce the village hall, shop, and village store as basic ones of RCFs in the village level, which should form a single complex connected mutually and functionally each other.

  • PDF