• Title/Summary/Keyword: Small Generator

Search Result 686, Processing Time 0.029 seconds

A Study on Design and Performance Analysis of a Prototype Permanent Magnet Synchronous Generator (영구자석 동기발전기의 설계 및 시제품 특성 분석에 관한 연구)

  • Oh, Jin-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.75-80
    • /
    • 2014
  • The small wind turbines has the merits of setting up with low costs by individuals, and get the energy saving effects that, it has the secured, separate markets from the big range systems, and the developing of it is continuously proceeding. The objective of this paper is to provide the design characteristics analysis of a permanent magnet synchronous generator(PMSG) skewed for magnet of rotor, the main advantage to be explored with the use of a split core design is the reduction in manufacturing costs and its simplicity in manufacture, compared to the manufacturing costs of a core skew PM machine. This thesis is aiming mainly analyzing the characteristics of the prototype to verify through Finite Element Method(FEM) and tests.

Design and Analysis of Direct-Coupled, Small-Scaled Permanent Magnet Generator for Wind Power Application (풍력발전을 위한 소용량 영구자석형 동기발전기의 설계 및 해석)

  • Kim, Il-Jung;Choi, Jang-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.39-51
    • /
    • 2014
  • This paper deals with design of a direct-coupled, small-scaled permanent magnet generator (PMG) for wind power application. First, this paper determines rated power and speed of the PMG from measured characteristics of wind turbines. Second, we derive analytical solutions for the open-circuit field in order to determine optimum magnet thickness and pole pitch/arc ratio. Third, on the basis of open circuit field solutions, stator magnetic circuit including slot opening, teeth width and yoke thickness is designed. And then, a diameter of stator coil which agree with a required current density is calculated, and its turns are determined from the area of slot considering winding packing factor. Finally, finite element (FE) method is employed in analyzing the details of the designed PMG and, test results such as back-emf measurements are given to confirm the design.

Design of Single/Multiband Impulse Generator Using SRD for UWB(Ultra Wideband) Technique (SRD를 이용한 UWB 기술용 단일/멀티밴드 Impulse Generator의 설계)

  • Kim, Ki Nam;Kim, Ihn Seok
    • Journal of Advanced Navigation Technology
    • /
    • v.9 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • In this paper, an impulse generator for UWB(Ultra Wide-band) technique with great possibility to be adopted as a next generation indoor WLAN(Wireless Local Area Network) has been designed by using SRD(Step Recovery Diode). Design goal is to design an impulse generator with simple structure, low cost, small size, and high performance. The impulse generator satisfied by FCC's regulation ( frequency range: 3.1~10.6 GHz, limit of power level: -41.25 dBm ) has been simulated by using ADS(Advanced Design System) which is the trade name of the Agilent Technologies. The output power of the impulse generator has been explained separately for single and multi band purposes, respectively.

  • PDF

On the Optimum Linear Voltage Regulator of a Self-excited DC Shunt Generator (직류자여자분권발전기의 최적선형전압조정기에 관한 연구)

  • Jong Swoo Won
    • 전기의세계
    • /
    • v.22 no.4
    • /
    • pp.11-16
    • /
    • 1973
  • This paper presents an optimum control of the field resistance for the self-excited DC shunt generator to keep a constant terminal voltage in case of the load change or the torque variation in the system. The non-linearity of the system is linearized by applying the small signal technique and the linearized equation is solved by the maximum principle with the digital computer. The optimal control value of the field resistance for the step error of the generator output voltage is obtained and the transient voltage characteristics in the system are investigated.

  • PDF

Permanent Magnet Excited Generator For Gearless Wind Generation Plant

  • Curiac, Paul;Kang, D.H.;Park, D.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.455-458
    • /
    • 2001
  • This paper presents an axial flux permanent magnet synchronous generator with a high power-to-weight ratio, dedicated for small-scale gearless wind power generation plants. For this purpose, a specific design is necessary to meet the imposed requirements. In this paper the design technique for the specifications is presented. The aim of the paper is also to discuss some of the first obtained test results and the involved demagnetizing problem (i.e. short-circuit).

  • PDF

A study on electronic braking system using wind power synchronous generator's armature reaction (풍력용 동기발전기의 전기자 반작용을 이용한 전기 제동방식에 관한 연구)

  • Park, Gui-Yeol;Moon, Chae-Joo;Cheang, Eui-Heang;Chang, Yung-Hak;Kim, Eui-Sun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.1-8
    • /
    • 2010
  • The mechanical parts of small windp ower generator less than 10kW are manufactured in the form of removing most of the accelerators. The braking system to protect blade from damages caused by high wind speed is manufactured in a manner having apparatus system(furling), manual brake or no brake. This study is on braking system in small size wind power generator, and carried out survey as following steps by applying electric braking system which uses armature reaction. We explained the principle of electric braking system and the principle of existing braking system. Also, this paper interpreted short circuit current through open circuit and short circuit, as well as checking brake system's action using armature reaction with real construction of control device.

Vibration Monitoring and Power Performance Evaluation of a Small Stand-alone Wind Turbine Generator (소형 독립형 풍력발전기의 진동 모니터링 및 출력 성능 평가)

  • Yoo, N.S.;Kim, Yoon-Ho;Kim, Seock-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.2 s.119
    • /
    • pp.114-120
    • /
    • 2007
  • Vibration performance of a 6 kW stand-alone wind turbine(W/T) generator is investigated under the wind environment of Daegwanryung mountain area. In the W/T, wind condition, power performance and structural stability are correlated each other An integrated monitoring system which consists of accelerometers, anemometers, power meters and auxiliary sensors for atmospheric data are constructed to measure the required data simultaneously. Based upon the data acquired over a long period of time, vibration performance of the W/T structure is estimated with annual wind data and generating power performance. Within the operating speed range, possibility of severe nitration is diagnosed. Vibration sources are identified and countermeasures are proposed. The goal of the study is to offer the basic information on W/T vibration performance at the design stage of a small stand alone W/T structure.

Steam generator performance improvements for integral small modular reactors

  • Ilyas, Muhammad;Aydogan, Fatih
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1669-1679
    • /
    • 2017
  • Background: Steam generator (SG) is one of the significant components in the nuclear steam supply system. A variety of SGs have been designed and used in nuclear reactor systems. Every SG has advantages and disadvantages. A brief account of some of the existing SG designs is presented in this study. A high surface to volume ratio of a SG is required in small modular reactors to occupy the least space. In this paper, performance improvement for SGs of integral small modular reactor is proposed. Aims/Methods: For this purpose, cross-grooved microfins have been incorporated on the inner surface of the helical tube to enhance heat transfer. The primary objective of this work is to investigate thermal-hydraulic behavior of the proposed improvements through modeling in RELAP5-3D. Results and Conclusions: The results are compared with helical-coiled SGs being used in IRIS (International Reactor Innovative and Secure). The results show that the tube length reduces up to 11.56% keeping thermal and hydraulic conditions fixed. In the case of fixed size, the steam outlet temperature increases from 590.1 K to 597.0 K and the capability of power transfer from primary to secondary also increases. However, these advantages are associated with some extra pressure drop, which has to be compensated.

Development of Simulated signal generator for Small Millimeter-wave Tracking Radar (소형 밀리미터파 추적 레이다용 모의신호 발생장치 개발)

  • Kim, Hong-Rak;Park, Seung-Wook;Woo, Seon-Keol;Kim, Youn-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.3
    • /
    • pp.157-163
    • /
    • 2019
  • A small millimeter-wave tracking radar is a pulse radar that searches, detects, and tracks a target in real time through a TWS (Track While Scan) method on a sea-going traps target with a large RCS running at low speed. This paper describes the development of a simulated signal generator to verify the performance of a small millimeter wave tracking radar in laboratory anechoic chamber environment. We describe a GUI program for testing and performance analysis in conjunction with hardware configuration and tracking radar, and verified the simulated signal generator implemented through performance test.

Power Quality Analysis of Wind-Diesel Hybrid Generation System Installation Area (복합발전 풍력-디젤 하이브리드 시스템 설치 지역의 전력품질 분석)

  • An, Hae-Joon;Kim, Hyun-Goo;Kim, Seok-Woo;Ko, Seok-Whan;Jang, Gil-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.539-541
    • /
    • 2009
  • A severely cold weather condition of King Sejong Station, Antarctica becomes a very severe condition for an installation/operation of wind generation system. When the existing wind generation system works, it may cause a damage and destruction of wind generation system and can bring about big problems in terms of the power quality. Accordingly, it is essential to obtain technologies for the installation and operation of small wind generation system for the polar region's wind generation, and to assess and demonstrate the performance in the severely-cold environment and the polar wind generation system's development, supplementation, alteration. Also, as the available power of King Sejong Station, Antarctica, the diesel generator has been mainly used, and the wind generator has been used in the hybrid form. Wind generation and diesel generation has the different load following control each other. In the wind generation, the generated power very rapidly changes according to the change of the velocity of the wind. On the other hand, the diesel generation shows very gentle change in the velocity of output. Therefore, the study is intended to analyze the 10kw small wind generator-diesel generator's power quality of King Sejong Station, Antarctica, which is the hybrid system installation area.

  • PDF