• Title/Summary/Keyword: Slow component

Search Result 149, Processing Time 0.029 seconds

Design of Heavy Weight Door Hinge for Built-in Appliances (빌트인 가전기기용 고 중량 도어힌지의 설계에 관한 연구)

  • Choi, Seong-Dae;Byn, Yong-Kun;Kim, Gi-Man
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.41-47
    • /
    • 2021
  • In this study, the hinges of heavy weight doors were designed and analyzed in line with the trend that built-in appliances are becoming larger and the weight of doors is also increasing. The main specification of the heavy weight door hinge is to allow the deflection at the end of the door to be less than 2 mm when opening and closing, including the automatic closing, slow closing, and closing force control functions. The structural analysis of the design mechanism, component design, and methods for improving the deflection are as follows: 1) Mechanism of the automatic closing function should sense automatically using the spring compression force at a specific angle by the contact between the cam and the cam module roller. 2) Through structural analysis, the maximum stress of the door was found in the link pin hole connected to the pin at each link. 3) Consequently, the pin holder was designed and applied, with little variance, but up to 93% of the specification limit.

Diagnosis of Alzheimer's Disease using Wrapper Feature Selection Method

  • Vyshnavi Ramineni;Goo-Rak Kwon
    • Smart Media Journal
    • /
    • v.12 no.3
    • /
    • pp.30-37
    • /
    • 2023
  • Alzheimer's disease (AD) symptoms are being treated by early diagnosis, where we can only slow the symptoms and research is still undergoing. In consideration, using T1-weighted images several classification models are proposed in Machine learning to identify AD. In this paper, we consider the improvised feature selection, to reduce the complexity by using wrapping techniques and Restricted Boltzmann Machine (RBM). This present work used the subcortical and cortical features of 278 subjects from the ADNI dataset to identify AD and sMRI. Multi-class classification is used for the experiment i.e., AD, EMCI, LMCI, HC. The proposed feature selection consists of Forward feature selection, Backward feature selection, and Combined PCA & RBM. Forward and backward feature selection methods use an iterative method starting being no features in the forward feature selection and backward feature selection with all features included in the technique. PCA is used to reduce the dimensions and RBM is used to select the best feature without interpreting the features. We have compared the three models with PCA to analysis. The following experiment shows that combined PCA &RBM, and backward feature selection give the best accuracy with respective classification model RF i.e., 88.65, 88.56% respectively.

Thermoluminescene Properties of Li6Gd(BO3)3:Ce3+ Scintillation Single Crystal (리튬 가돌리늄 보레이트 섬광단결정의 열형광 특성)

  • Kim, Sunghwan;Lee, Joonil
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.455-459
    • /
    • 2014
  • We grew the $Li_6Gd(BO_3)_3:Ce^{3+}$ scintillator and determined the scintillation and thermoluminescence properties for X-rays. The emission spectrum of $Li_6Gd(BO_3)_3:Ce^{3+}$ is located in the range of 370~500 nm, peaking at 423 nm an 455 nm, due to the $4f{\rightarrow}5d$ transition of $Ce^{3+}$ ions. The fluorescence decay time of the crystal is composed three components. The fast component is 60 ns (25%), the intermediate component is 787 ns (29%) and the slow component is $5.9{\mu}s$ (46%) of the crystal. The after-glow is caused by the electron and hole traps in the crystal lattice. We determined physical parameters of the traps in the crystal. The thermoluminescence trap are composed two traps. The determined activation energy (E), kinetic order (m) and frequency factor (s) of the first trap are 0.65 eV, 1.01 and $6.9{\times}10^8s^{-1}$. And, the determined activation energy, kinetic order and frequency factor of the second trap are 0.96 eV, 1.79 and $3.1{\times}10^{12 }s^{-1}$, respectively.

Studies on the Development of Compound Fertilizer for Raising Rice Seedling in Trays for Machine Transplanting -I. Manufacture of Compound Fertilizer (수도상자육묘용(水稻箱子育苗用) 전용복합비료(專用複合肥料) 개발연구(開發硏究) -I. 비료(肥料) 제조시험(製造詩驗))

  • Choi, Du-Hoi;Yuk, Chang-Soo;Shin, Jae-Sung;Han, Ki-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.22 no.2
    • /
    • pp.100-104
    • /
    • 1989
  • This study was carried out in order to develop a compound fertilizer for raising rice seedling in trays. A compound fertilizer, a trail product, was manufactured using the major fertilizer sources of ammonium sulfate, diammonium phosphate and potassium chloride in combination with zeolite and glutamic acid fermentation waste. Besides, polyacrylamide for slow release control of the fertilzer and Tachigaren and sulfuric acid for reducing the occurrence of seedling rot were used. The component ratios of N, $P_2O_5$ and $K_2O$ of trial product were 4.19, 5.41 and 4.05 percent respectively. The dissolution rate of nitrogen component in water for the trial product with polyacrylamide was lower about fifteen percents than the product without polyacylamide in six hours. Hymexazole, main component of Thachigaren, from the product was released about 86.2 percents in forty eight hours. When the product with polyacylamide applied on red earth soil and paddy soil, the pH of soil ranged from 4.6 to 5.4 for 25 days experiment.

  • PDF

Influences of Gastric Mucosa upon the Catecholamine Induced Gastric Motility in Guinea-pig (기니피그 위점막이 카테콜아민 유발 위운동에 미치는 영향)

  • Rhee, Poong-Lyul;Kim, Ki-Whan;Lee, Sang-Jin
    • The Korean Journal of Physiology
    • /
    • v.23 no.2
    • /
    • pp.277-289
    • /
    • 1989
  • The effects of noradrenaline on the contractile and electrical activities were investigated using the circular muscle strips with intact mucosa prepared from the antrum and fundus of guinea-pig stomach. Electrical responses of circular muscle cells were recorded using glass capillary microelectrodes filled with 3 M KCI. All experiments were performed in tris-buffered Tyrode solution which was aerated with 100% $O_2\;and\;kept\;at\;35^{\circ}C$. The results obtained were as follows: 1) The spontaneous contractions recorded from the antral and fundic circular muscle strips with intact mucosa were suppressed dose-dependently by the application of noradrenaline, whereas those recorded from the mucosa-free strips were potentiated in a dose-dependent manner. 2) The inhibitory influences on the contractile activities in the normal intact strips were developed via both ${\alpha}-adrenoceptors\;and\;{\beta}-adrenoceptors$, while the excitatory influences in the mucosa-free strips resulted from the strong excitatory effect via ${\alpha}-adrenoceptors$ and the weak inhibitory effect via ${\beta}-adrenoceptors$. 3) Noradrenaline produced hyperpolarization of membrane potential, and increased the amplitude and the maximum rate of rise of slow waves in the mucosa-free strips of antral and fundic circular muscle. 4) Apamin blocked the appearance of the component of initial suppression of spontaneous phasic contractions observed in the mucosa-free strips of antral circular muscle after the application of noradrenaline. 5) The inhibitory influences on the contractile activities in the normal strips with intact mucosa remained unaffected even in the strip with separate mucosa, in which mucosa and muscle layer were mechanically disconnected . From the above results, following conclusions could be made. (1) There are no regional differences between the effects of noradrenaline on the antral circular muscle and those on the fundic circular muscle. (2) Excitatory responses to noradrenaline observed in the mucosa-free strip result from the dominant ${\alpha}-excitatory$ and tile weak ${\beta}-inhibitory$ action of noradrenaline. (3) Inhibitory responses to noradrenaline in the normal strips with intact mucosa develop via both ${\alpha}-inhibitory\;and\;{\beta}-inhibitory$ actions.

  • PDF

Relationship Between Amyloid Positivity and Sleep Characteristics in the Elderly With Subjective Cognitive Decline

  • Kyung Joon Jo;SeongHee Ho;Yun Jeong Hong;Jee Hyang Jeong;SangYun Kim;Min Jeong Wang;Seong Hye Choi;SeungHyun Han;Dong Won Yang;Kee Hyung Park
    • Dementia and Neurocognitive Disorders
    • /
    • v.23 no.1
    • /
    • pp.22-29
    • /
    • 2024
  • Background and Purpose: Alzheimer's disease (AD) is a neurodegenerative disease characterized by a progressive decline in cognition and performance of daily activities. Recent studies have attempted to establish the relationship between AD and sleep. It is believed that patients with AD pathology show altered sleep characteristics years before clinical symptoms appear. This study evaluated the differences in sleep characteristics between cognitively asymptomatic patients with and without some amyloid burden. Methods: Sleep characteristics of 76 subjects aged 60 years or older who were diagnosed with subjective cognitive decline (SCD) but not mild cognitive impairment (MCI) or AD were measured using Fitbit® Alta HR, a wristwatch-shaped wearable device. Amyloid deposition was evaluated using brain amyloid plaque load (BAPL) and global standardized uptake value ratio (SUVR) from fluorine-18 florbetaben positron emission tomography. Each component of measured sleep characteristics was analyzed for statistically significant differences between the amyloid-positive group and the amyloid-negative group. Results: Of the 76 subjects included in this study, 49 (64.5%) were female. The average age of the subjects was 70.72±6.09 years when the study started. 15 subjects were classified as amyloid-positive based on BAPL. The average global SUVR was 1.598±0.263 in the amyloid-positive group and 1.187±0.100 in the amyloid-negative group. Time spent in slow-wave sleep (SWS) was significantly lower in the amyloid-positive group (39.4±13.1 minutes) than in the amyloid-negative group (49.5±13.1 minutes) (p=0.009). Conclusions: This study showed that SWS is different between the elderly SCD population with and without amyloid positivity. How SWS affects AD pathology requires further research.

Waveguide Spatial Interference Filtering in Adaptive Matched Field Processing (적응 정합장처리에서 도파관 공간간섭 필터링)

  • 김재수;김성일;신기철;김영규;박정수
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.288-295
    • /
    • 2004
  • Detection and localization of a slow and quiet target in shallow water environments is a challenging problem for which it is well known that snapshot is deficient because of a fast and strong interferer. This paper presents waveguide interference filtering technique that mitigate strong interferer problems in adaptive matched field processing. MCM (multiple constraint method) based on NDC (null direction constraint) has been proposed for new spatial interferer filter. MCM-NDC using replica force a interferer component to be filtered through CSDM (cross-spectral density matrix). This filtering have an effect on sidelobe reduction and restoring of signal gain of a quiet target. This technique was applied to a simulation on Pekeris waveguide and vertical array data from MAPLE03 (matched acoustic properties and localization experiment) in the East Sea and was shown to improve SBNR (signal-to-background-and-noise ratio) over the standard MVDR (minimum-variance distortionless response) and NSP (null space projection) technique.

Evaluation of the Corrosion Resistance of Steel Coated with Zinc Using a Cr-free Coating Solution as a Function of Heat Treatment Time (Cr-free 코팅액에 의한 아연도금강판의 건조시간에 따른 내식특성)

  • Seo, Hyun-Soo;Moon, Hee-Joon;Kim, Jong-Soon;Ahn, Seok-Hwan;Moon, Chang-Kwon;Nam, Ki-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.67-74
    • /
    • 2010
  • Chromate conversion coating is a coating technique used to passivate aluminum, zinc, cadmium, copper, silver, magnesium, tin, and their alloys to slow corrosion. The process uses various toxic chromium compounds, which may include hexavalent chromium. The industry is developing less toxic alternatives in order to comply with substance restriction legislation, such as RoHS. One alternative is to develop a Cr-free coating solution. In this study, eco-friendly, Cr-free solutions (urethane solution S-700, organic/inorganic solution with Si LRO-317) were used. Test specimens were dried in a drying oven at $190^{\circ}C$ for 3, 5, 7, and 9 minutes. Corrosion resistance was evaluated using a salt spray test for 72 hours. The results show that the optimum corrosion resistance was achieved at $190^{\circ}C$ for five minutes for EGI and three or five minutes for HDGI, respectively. The adhesive properties of the two types of coating solutions were superior regardless of drying time.

A New Temporal Filtering Method for Improved Automatic Lipreading (향상된 자동 독순을 위한 새로운 시간영역 필터링 기법)

  • Lee, Jong-Seok;Park, Cheol-Hoon
    • The KIPS Transactions:PartB
    • /
    • v.15B no.2
    • /
    • pp.123-130
    • /
    • 2008
  • Automatic lipreading is to recognize speech by observing the movement of a speaker's lips. It has received attention recently as a method of complementing performance degradation of acoustic speech recognition in acoustically noisy environments. One of the important issues in automatic lipreading is to define and extract salient features from the recorded images. In this paper, we propose a feature extraction method by using a new filtering technique for obtaining improved recognition performance. The proposed method eliminates frequency components which are too slow or too fast compared to the relevant speech information by applying a band-pass filter to the temporal trajectory of each pixel in the images containing the lip region and, then, features are extracted by principal component analysis. We show that the proposed method produces improved performance in both clean and visually noisy conditions via speaker-independent recognition experiments.

Picosecond Fluorescence Lifetimes of Hematoporphyrin Derivatives in Solutions and in vitro (용액 및 시험관 실험에서의 헤마토포르피린 유도체 분자의 피코초 형광수명시간 분석)

  • Kim, Hyun-Soo;Chu, Sung-Sil;Kim, Gwi-Eon;Lee, Won-Young;Kim, Ung
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.61-70
    • /
    • 1995
  • The picosecond time resolved fluorescence spectra of Hematoporphyrin Derivative (HPD) in both solutions and cancer cell are measured by a time correlated single photon counting system with a synchronously mode locked dye laser. Two exoponential decay components in the fluorescence spectra were observed. The slow decay(6.3 ㎱)and the fast one(350 ㎰)are attributed to be originated from monomers and dimers, respectively. The absorption and fluorescence measurements in steady state also showed the presence of a monomeric and dimeric forms of HPD molecules. The monomer lifetime in the cancer cell was measured to be longer than that in solution, which was expected from the blue shift and narrowing of the absorption spectra for HPD-treated in vitro. The relative amplitude of the fast component was found to be enhanced in cancer cell, strongly indicating the higher affinity of the dimer for the cancer cell.

  • PDF