• 제목/요약/키워드: Slice

검색결과 984건 처리시간 0.025초

RIQUIER AND DIRICHLET BOUNDARY VALUE PROBLEMS FOR SLICE DIRAC OPERATORS

  • Yuan, Hongfen
    • 대한수학회보
    • /
    • 제55권1호
    • /
    • pp.149-163
    • /
    • 2018
  • In recent years, the study of slice Dirac operators has attracted more and more attention in the literature. In this paper, Almansitype decompositions for null solutions to the iterated slice Dirac operator and the generalized slice Dirac operator are obtained without a star-like domain centered at the origin. As applications, we investigate Riquier type problems and Dirichlet type problems in the theory of slice monogenic functions.

냉장저장 중 사과 슬라이스의 갈변에 미치는 갈변저해제의 효과 (Effects of Antibrowning agents on browning of apple slices during cold storage)

  • 안선정;이귀주
    • 한국식품조리과학회지
    • /
    • 제21권1호
    • /
    • pp.24-32
    • /
    • 2005
  • 냉장 저장 시 사과슬라이스의 갈변정도 및 조직감과 같은 물리적인 변화와 PPO활성, 총페놀 함량등의 화학적 변화를 측정하였으며 관능검사를 행하여 비교하였으며 또한 이들 변화들 간의 상관관계를 알아본 결과는 다음과 같다. 갈변 정도는 fresh apple slice, 물에 침지한 시료군, CP 시료군, ascorbic acid 시료군 모두 증가하는 경향을 나타냈으며 그 크기는 fresh apple slice>물에 침지한 시료군>ascorbic acid 시료군>CP 시료군 순이었으며, PPO활성은 시료군 모두 증가하는 경향을 나타냈으며 그 크기는 fresh apple slice>물에 침지한 시료군>ascorbic acid 시료군>CP 시료군 순이었으며 CP 시료군의 증가가 가장 낮았다. 총페놀 함량은 fresh apple slice군은 60 mg/100 g에서 56.2 mg/100 g로 감소하는 경향을 보였으나 물에 침지한 시료군은 59.6 mg/100 g에서 56.0 mg/100 g으로, CP 시료군, ascorbic acid 처리군은 51.9 mg/100 g에서 52.8mg/100 g로, 54.1 mg/100 g에서 54.4 mg/100 g로 나타났다. 조직감은 시료군 모두 감소하는 경향을 보였으며 그 크기는 fresh apple slice>물에 침지한 시료군>ascorbic acid 시료군>CP 시료군 순으로 감소하였다. 또한 관능 검사에서 CP 시료군이 다른 처리군들 보다 더 효과적인 것으로 나타났다. 상관관계 분석에서 갈변 정도와 PPO활성, 총페놀 함량 등이 높은 상관성을 나타내었다. 이러한 연구결과로 사과 슬라이스의 냉장 저장중 효소적 갈변 변화에 대한 영향에서 카라멜 생성물에 침지한 CP 시료군이 효소적 갈변에 대한 저해 효과가 있는 것으로 나타났으며 기타 다른 요인에서도 효과적인 것으로 나타나 sucrose의 카라멜 생성물을 채소 및 과일의 저장 과정에 갈변 억제물질로 이용할 수 있을 것으로 생각된다.

상층두께와 관심영역의 크기 변화가 CT 번호에 미치는 영향 (Effect of the slice thickness and the size of region of interest on CT number)

  • 이지연;김기덕;박창서
    • Imaging Science in Dentistry
    • /
    • 제31권2호
    • /
    • pp.85-91
    • /
    • 2001
  • Purpose: To evaluate the effect of the slice thickness and the size of region of interest (ROI) on CT number using quantitative CT phantom Materials and Methods: The phantom containing 150 mg/cc, 75 mg/cc and 0 mg/cc calcium hydroxyapatite was scanned with 1, 3, 5 and 10 mm slice thicknesses by single energy quantitative computed tomography (QCT). CT numbers were measured on center position of the phantom. Shape of ROI was circular and sizes were 1, 3, 5, 11, 16, 21, 26 and 33 mm². ANOVA and Tukey's multiple comparison method were performed for statistical comparison of CT numbers according to different slice thicknesses. Coefficient of variation of CT number measured in each size of ROI was evaluated in same slice thickness. Results : CT numbers had statistically significant difference according to slice thicknesses (p<0.05). As the slice thickness increased, CT number also increased. As the density of phantom became lower and the size of ROI became smaller, the coefficient of variation of CT number increased. When the size of ROI was more than 11 mm² in 1 mm slice thickness, 5 mm² in 3 mm slice thickness and 3 mm² in 5 mm slice thickness, the coefficient of variation became consistent. In 10 mm slice thickness, the size of ROI had little effect on the coefficient of variation. Conclusion: CT number had variation according to the slice thickness and the size of ROI although the object was homogeneous. The slice thickness and the size of ROI are critical factors in precision of the CT number measurements.

  • PDF

ON THE TRANSFORMATION FORMULA OF THE SLICE BERGMAN KERNELS IN THE QUATERNION VARIABLES

  • Park, Jong-Do
    • 대한수학회보
    • /
    • 제53권5호
    • /
    • pp.1401-1409
    • /
    • 2016
  • In complex analysis, the Bergman kernels for two biholomorphically equivalent complex domains satisfy the transformation formula. Recently new Bergman theory of slice regular functions of the quaternion variables has been investigated. In this paper we construct the transformation formula of the slice Bergman kernels under slice biregular functions in the setting of the quaternion variables.

미래인터넷 테스트베드의 Semi-federated Slice Control을 위한 Plastic Slice의 S/W 모델 (S/W model of Plastic Slice for Semi-federated Slice Control of Future Internet Testbed)

  • 차병래;김종원
    • 한국항행학회논문지
    • /
    • 제16권5호
    • /
    • pp.817-830
    • /
    • 2012
  • 통신 및 컴퓨팅 환경의 급격한 변화 및 다양한 사용자 요구사항의 증대로 인해 현재의 인터넷이 갖는 근본적인 문제를 해결하기 위한 노력으로 미래인터넷 연구가 국내외로 활발히 진행되고 있다. 본 연구에서는 미래 인터넷의 연구 주제인 Federation Job Control에 대한 Plastic Slice의 소프트웨어 모델의 기초 개념과 아이디어를 제안한다.

모형물을 이용한 전산화 단층 촬영에서 3차원적 부피측정의 정확성 평가 (Three-Dimensional Volume Assessment Accuracy in Computed Tomography Using a Phantom)

  • 김현수;왕지환;임일혁;박기태;연성찬;이희천
    • 한국임상수의학회지
    • /
    • 제30권4호
    • /
    • pp.268-272
    • /
    • 2013
  • The purpose of this study was to assess the effects of reconstruction kernel, and slice thickness on the accuracy of spiral CT-based volume assessment over a range of object sizes typical of synthetic simulated tumor. Spiral CT scanning was performed at various reconstruction kernels (soft tissue, standard, bone), and slice thickness (1, 2, 3 mm) using a phantom made of gelatin and 10 synthetic simulated tumors of different sizes (diameter 3.0-12.0 mm). Three-dimensional volume assessments were obtained using an automated software tool. Results were compared with the reference volume by calculating the percentage error. Statistical analysis was performed using ANOVA and setting statistical significance at P < 0.05. In general, smaller slice thickness and larger sphere diameters produced more accurate volume assessment than larger slice thickness and smaller sphere diameter. The measured volumes were larger than the actual volumes by a common factor depending on slice thickness; in 100HU simulated tumors that had statistically significant, 1 mm slice thickness produced on average 27.41%, 2 mm slice thickness produced 45.61%, 3 mm slice thickness produced 93.36% overestimates of volume. However, there was no statistically significant difference in volume error for spiral CT scans taken with techniques where only reconstruction kernel was changed. These results supported that synthetic simulated tumor size, slice thickness were significant parameters in determining volume measurement errors. For an accurate volumetric measurement of an object, it is critical to select an appropriate slice thickness and to consider the size of an object.

An Efficient Network Slice Configuration Method in 5G Mobile Networks

  • Kim, Jae-Hyun
    • 한국컴퓨터정보학회논문지
    • /
    • 제27권9호
    • /
    • pp.101-112
    • /
    • 2022
  • 본 논문에서는 5G 네트워크 슬라이싱에 대해서 분석하고 5G 이동 통신망에서의 효율적인 네트워크 슬라이스 설정 방안을 제안한다. 5G 이동 통신망에서 네트워크 슬라이싱은 네트워크 슬라이스 인스턴스 정보에 기반하여 구분되고 수행된다. 단말과 네트워크 간의 네트워크 슬라이스 인스턴스 정보가 상호 일치하지 않는 경우, 단말의 PDU 세션 연결 요청 실패에 따른 불필요한 시그널링 오버헤드가 발생한다. 본 논문은 이러한 문제를 해결하기 위해서, 두 가지 효율적인 네트워크 슬라이스 설정 기법, 단말 기반 ENSC(Efficient Network Slice Configuration) 기법과 네트워크 기반 ENSC 기법을 제안한다. 제안하는 두 가지 기법들은 신속한 단말과 네트워크 간의 최신 변경 업데이트된 네트워크 슬라이스 정보를 제공 설정 수행하게 되어, 기존 방안과 비교하여 배터리 리소스 효율성을 향상시키고 불필요한 시그널링 오버헤드를 최소화할 수 있다.

전산화단층촬영 검사의 방사선 선량에 관한 연구 (A Study on the Radiation Dose in Computed Tomographic Examinations)

  • 임청환;조정근;이만구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권4호
    • /
    • pp.381-389
    • /
    • 2007
  • 본 연구는 전산화단층촬영 검사의 방사선 선량에 관하여 조사하고자 하였다. 이를 위하여 문헌고찰을 실시하였으며, 여러 기관으로부터 자료를 수집하였고, 각 의료기관의 CT장비에서 선량을 측정하였으며, 병원에서 시행하고 있는 Protocol에 입각하여 피폭선량을 계산하였다. 이 연구의 주요 결과는 다음과 같다. 1. 두부팬텀을 이용하여 측정된 100 mAs 당 $CTDI_W$ 값은 4 slice MDCT 장비가 24.20 mGy로 가장 높았다. 장비의 세대별 구분에 따른 $CTDI_W$ 값은 통계적으로 유의한 차이가 있었다(p < 0.01). 2. 복부팬텀을 이용하여 측정한 100 mAs 당 $CTDI_W$ 값은 4 slice MDCT 장비가 13.58mGy로 가장 높았으며, $CTDI_W$ 값은 장비 세대별로 통계적으로 유의한 차이가 있었다(p<0.01). 3. 두부검사에서의 환자선량은 조영제를 사용하지 않을 경우에 가장 높은 장비는 16 slice MDCT로 $818.83\;mGy{\cdot}cm$이었다(p < 0.05). 조영제를 사용하는 경우는 4 slice MDCT 장비에서 $1460.77\;mGy{\cdot}cm$로 가장 높게 측정되었으며, 평균 환자선량은 장비 종류 사이에 유의한 차이가 있었다(p < 0.1). 4. 흉부검사에서의 환자선량은 조영제를 사용하지 않을 경우에 16 slice MDCT에서 평균은 $521.63\;mGy{\cdot}cm$로 가장 높았으며, 장비종류별로 유의한 차이가 있었다(p < 0.05). 조영제를 사용하는 경우에 8 slice MDCT 장비에서의 환자선량이 평균 $1,174.70\;mGy{\cdot}cm$로 가장 높았으며, 장비별로 평균 환자선량에는 통계적으로 유의한 차이는 없었다. 5. 복부-골반검사에서 조영제를 사용하지 않을 경우에 환자선량이 가장 높은 장비는 16 slice MDCT 장비로 평균은 $856.27\;mGy{\cdot}cm$이었으며, 평균 환자선량은 장비 사이에 유의한 차이가 있었다(p < 0.05). 조영제를 사용하는 경우 환자선량이 가장 높은 장비는 16 slice MDCT로 평균 $1,720.64\;mGy{\cdot}cm$이었다. 평균 환자선량은 장비 사이에 유의한 차이가 있었다(p < 0.05). 6. 간 검사에서 조영제를 사용하지 않을 경우에 환자선량이 가장 높은 장비는 8 slice MDCT로 평균 환자선량은 $612.07\;mGy{\cdot}cm$이었고, 환자선량은 장비사이에 유의한 차이가 있었다(p < 0.05). 조영제를 사용하는 경우의 환자선량은 8 slice MDCT 장비의 평균이 $2,197.93\;mGy{\cdot}cm$로 가장 높았으며, 장비사이에 유의한 차이가 있었다(p < 0.1). 조사대상 의료기관의 76.2%에서 조영제를 투여하는 검사의 반복횟수가 $3{\sim}4$회로 방사선피폭에 의한 위험이 있을 것으로 추정되었다.

  • PDF

슬라이스 복잡도 측정을 위한 VFG의 사용 (The Use of VFG for Measuring the Slice Complexity)

  • 문유미;최완규;이성주
    • 한국정보통신학회논문지
    • /
    • 제5권1호
    • /
    • pp.183-191
    • /
    • 2001
  • 본 논문은 데이터 슬라이스에서의 정보 흐름을 모델링하기 위해서 데이터 값 흐름 그래프(VFG: data Value Flow Graph)라고 하는 새로운 데이터 슬라이스(data slice) 표현을 개발한다. 다음으로, VFG에서의 정보 흐름의 복잡도를 측정하기 위해 기존의 흐름 복잡도를 이용하여 슬라이스 복잡도 척도를 정의한다. 본 연구에서는 각 슬라이스에 대한 슬라이스 복잡도와 전체 슬라이스 복잡도 간의 관계를 보여주고, VFG에서의 극소 수정(atomic modification)과 합성 연산자(concatenation operator)를 통해서 슬라이스 복잡도 척도의 스케일(scale) 인자들을 증명한다.

  • PDF

16-QAM 신호에서 Slice 가중치에 의한 S-MMA 적응 등화 알고리즘의 성능 비교 (Performance Comparison of S-MMA Adaptive Equalization Algorithm by Slice Weighting Value in 16-QAM Signal)

  • 임승각
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권3호
    • /
    • pp.55-61
    • /
    • 2013
  • 본 논문에서는 통신 채널에서 발생되는 찌그러짐과 잡음의 영향을 최소화하기 위하여 사용되는 S-MMA 적응 등화 알고리즘에서 Slice 가중치에 따른 성능을 비교하였다. 기존의 MMA 알고리즘에서는 등화기의 출력 신호와 송신 신호의 dispersion 상수만을 이용하지만, S-MMA에서는 등화기 출력 신호와 dispersion 상수외에 결정 장치의 출력 신호를 slice 상수만큼 고려하여 채널의 진폭과 위상 찌그러짐을 동시에 보상할 수 있다. 이때 slice 가중치가 적응 등화 알고리즘의 성능에 미치는 영향을 컴퓨터 시뮬레이션을 통해 확인하며, 성능 지수로는 등화기 출력 신호 성상도, 수렴 특성을 나타내는 잔류 isi, 최대 찌그러짐, MSE와 채널의 신호대 잡음비에 따른 SER을 사용하였다. 시뮬레이션 결과 slice 가중치가 적으면 잔류isi, 최대 찌그러짐과 MSE 성능이 우월하며, 가중치가 큰 경우 SER 성능이 우월함을 확인하였다.