• Title/Summary/Keyword: Slenderness

Search Result 529, Processing Time 0.022 seconds

Evaluation of Buckling Strength of Surface Plates in Steel-Plate Concrete Walls with Studs and Tie-bars (스터드 및 타이바를 가진 강판콘크리트 벽체의 표면강판 좌굴강도 평가)

  • Koo, Jimo;Lee, Kyungkoo;Kim, Wonki;Lee, JongBo
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.3
    • /
    • pp.129-138
    • /
    • 2016
  • Buckling of surface plates is an important limit state in Steel-Plate Concrete (SC) walls under axial compression. The surface plates may be anchored to concrete using connectors of studs or tie-bars. In this paper, the effects of studs and tie-bars on buckling of surface plates were evaluated by conducting tests. Experiments have three types of connectors; all studs, all tie-bars, and the combination of studs and tie-bars. Also, experiments have the various ratios of stud or tie-bar spacing to surface plate thickness. The experimental investigation shows that the buckling shape and strength of the surface plate of SC wall with the combination of studs and tie-bars have good agreements with that of the surface plate of SC walls with all studs or all tie-bars.

Deflection Analysis of Long Span Structures Using Under-Tension System (언더텐션 시스템을 이용한 장스팬 구조의 처짐 거동 해석)

  • Park, Duk-Kun;Lee, Jin;Ham, Su-Yun;Ahn, Nam-Shik;Lee, Ki-Hak;Lee, Jae-Hong
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.66-69
    • /
    • 2008
  • This study presents deflection analysis of long span structures for pedestrian bridge on crossroads. For long span structures, the size of structural members should be determined considering the esthetic view and vehicle below the structures. As a result, the slenderness ratio of members is increased and the structure may be suffered from significant deflection. The under-tensioned system on lower part of the structure, is applied in order to reduce the deflection and the size of members. In this regard, the under-tensioned system enables the load of upper parts to carη to the end of beam by means of tensional force in cable. In addition, effectiveness of under-tensioned system can be different depending on the size of cable, the number and spacing of posts. This study is performed with conforming the effect by analytical various parameters (size of cable, number and spacing of post). Dead and live loads is supposed to apply in the slab, and the analytical result by MIDAS program are presented addressing the effect of the under-tensioned system.

  • PDF

Evaluation of Rocking Mechanism for Embedded Shallow Foundation via Horizontal Slow Cyclic Tests (수평반복하중 실험을 이용한 근입된 얕은 기초의 회전거동 메커니즘 평가)

  • Ko, Kil-Wan;Ha, Jeong-Gon;Park, Heon-Joon;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.8
    • /
    • pp.47-59
    • /
    • 2016
  • Rocking behavior of shallow foundation reduces the superstructure load during earthquake. However, because of deficiency of understanding of rocking mechanism and soil permanent deformation, it has not been applied to real construction. In this study, slow cyclic tests were conducted for embedded shallow foundations with various slenderness ratio via centrifuge tests. From the variation of earth pressure 'soil rounding surface' phenomenon which makes maximum overturning moment equal to ultimate moment capacity was observed. Rocking and sliding behavior mechanism was evaluated. Also, nonlinear behavior and energy dissipation increase as rotation angle increases. And ultimate moment capacity of embedded foundation is larger than that of surface foundation. Finally, adequate ultimate moment capacity can be suggested for seismic design through this study.

Free Vibrations of Timoshenko Beam with Elastomeric Bearings at Two Far Ends (양단이 탄성받침으로 지지된 Timoshenko 보의 자유진동)

  • Lee, Byoung Koo;Lee, Tae Eun;Park, Chang Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.181-187
    • /
    • 2011
  • This paper deals with free vibrations of the Timoshenko beam supported by two elastomeric bearings at two far ends. The ordinary differential equation governing free vibrations of such beam is derived, in which both effects of rotatory inertia and shear deformation are included as the Timoshenko beam theory. Also, boundary conditions of the free end are derived based on the Timoshenko beam theory. The ordinary differential equation is solved by the numerical methods for calculating natural frequencies and mode shapes. Both effects of the rotatory inertia and shear deformation on natural frequencies are extensively discussed. Also, relationships between natural frequencies and slenderness ratio, foundation modulus and bearing length are presented. Typical mode shapes of bending moment and shear force as well as deflection are given in figures which show the positions of maximum amplitudes and nodal points.

A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads

  • Park, Su-Hee;Choi, Sung-Mo;Chung, Kyung-Soo
    • Steel and Composite Structures
    • /
    • v.8 no.6
    • /
    • pp.491-510
    • /
    • 2008
  • This paper presents a plan and guidelines that were drawn for Korean based research carried out on the fire-resistance of CFT columns. This research was carried out by reviewing the Korean regulations related to the fire-resistance of CFT columns and examining studies which had been made in Korea as well as overseas. The first phase of the study plan was to compare the fire-resistance of square CFT columns without fire protection (obtained through fire-resistance tests and numerical analyses) with estimated values (obtained through fire-resistance design formulas proposed in Korea and overseas). This comparison provided conclusions as outlined below. Fire-resistance tests conducted in this study proved that, when the actual design load is taken into consideration, square CFT columns without fire protection are able to resist a fire for more than one hour. A comparison was made of test and analysis results with the fire-resistance time based on the AIJ code, the AISC design formula and the estimation formula suggested for Korea. The results of this comparison showed that the test and analysis results for specimens SAH1, SAH2-1, SAH2-2 and SAH3 were almost identical with the AIJ code, the AISC design formula and estimation formula. For specimens SAH4 and SAH5, the estimation formula was more conservative than the AIJ code and the AISC design formula. It was necessary to identify the factors that have an influence on the fire-resistance of CFT columns without fire protection and to draw fire-resistance design formulas for these columns. To achieve this, it is proposed that numerical analyses and tests be conducted in order to evaluate the fire-resistance of circular CFT columns, the influence of eccentricity existing as an additional factor and the influence of the slenderness ratio of the columns. It is also suggested that the overall behavior of CFT structures without fire protection within a fire be evaluated through analysis simulation.

Behavior of stiffened and unstiffened CFT under concentric loading, An experimental study

  • Deifalla, Ahmed F.;Fattouh, Fattouh M.;Fawzy, Mona M.;Hussein, Ibrahim S.
    • Steel and Composite Structures
    • /
    • v.33 no.6
    • /
    • pp.793-803
    • /
    • 2019
  • Concrete-filled steel tubular (CFST) beam-columns are widely used owing to their good performance. They have high strength, ductility, large energy absorption capacity and low costs. Externally stiffened CFST beam-columns are not used widely due to insufficient design equations that consider all parameters affecting their behavior. Therefore, effect of various parameters (global, local slenderness ratio and adding hoop stiffeners) on the behavior of CFST columns is studied. An experimental study that includes twenty seven specimens is conducted to determine the effect of those parameters. Load capacities, vertical deflections, vertical strains and horizontal strains are all recorded for every specimen. Ratio between outer diameter (D) of pipes and thickness (t) is chosen to avoid local buckling according to different limits set by codes for the maximum D/t ratio. The study includes two loading methods on composite sections: steel only and steel with concrete. The case of loading on steel only, occurs in the connection zone, while the other load case occurs in steel beam connecting externally with the steel column wall. Two failure mechanisms of CFST columns are observed: yielding and global buckling. At early loading stages, steel wall in composite specimens dilated more than concrete so no full bond was achieved which weakened strength and stiffness of specimens. Adding stiffeners to the specimens increases the ultimate load by up to 25% due to redistribution of stresses between stiffener and steel column wall. Finally, design equations previously prepared are verified and found to be only applicable for medium and long columns.

Investigation on the monotonic behavior of the steel rack upright-beam column connection

  • Cao, Yan;Alyousef, Rayed;Jermsittiparsert, Kittisak;Ho, Lanh Si;Alaskar, Abdulaziz;Alabduljabbar, Hisham;Alrshoudi, Fahed;Mohamed, Abdeliazim Mustafa
    • Smart Structures and Systems
    • /
    • v.26 no.1
    • /
    • pp.103-115
    • /
    • 2020
  • The cold-formed steel storage racks are extensively employed in various industries applications such as storing products in reliable places and storehouses before distribution to the market. Racking systems lose their stability under lateral loads, such as seismic actions due to the slenderness of elements and low ductility. This justifies a need for more investigation on methods to improve their behavior and increase their capacity to survive medium to severe loads. A standardized connection could be obtained through investigation on the moment resistance, value of original rotational stiffness, ductility, and failure mode of the connection. A total of six monotonic tests were carried out to determine the behavior of the connection of straight 2.0 mm, and 2.6 mm thickness connects to 5 lug end connectors. Then, the obtained results are benched mark as the original data. Furthermore, an extreme learning machine (ELM) technique has been employed to verify and predict both moment and rotation results. Out of 4 connections, increase the ultimate moment resistance of connection by 13% and 18% for 2.0 mm and 2.6 mm upright connection, respectively.

Planning and Design of Monorail Bridges (모노레일 교량의 계획 및 설계)

  • Han, Nock-Hee;Yoo, Je-Nam;Lee, Sumg-Min
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1174-1187
    • /
    • 2007
  • Monorail System has many advantages compared with other Urban Lightweight Transit Systems, such as the friendliness of the vehicle's appearance, slenderness of the bridge structures, it's low construction cost and short construction period. So, lots of city governments have reviewed or proposed the Monorail System as the attractive alternative system. And recently, Daegu Metropolitan City Government have chosen the Monorail System for the Urban Railroad Line 3. According to these trends on Urban Lightweight Transit Systems, this paper has introduced the outline of the planning and design of Monorail Bridges. At first, trends of overseas Monorail Bridges have been reviewed and the principal design criteria adopted in the basic design of the Urban Railroad Line 3 for Daegu have been introduced. And next, the methods of planning, design, fabrication of the guideway beams which are made of PSC Beam or Steel Beam have been explained. We hope this paper be helpful for the Engineers who are interested in the Monorail Bridges.

  • PDF

Beam-Like Ship Vibration Analysis in Consideration of Fluid (유체력을 고려한 보-유추 선체진동 해석)

  • Son, Choong-Yul
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.206-213
    • /
    • 1999
  • In the beam-like ship vibration analysis. three-dimensional correction factor(J-factor) can be calculated by considering the three-dimensional effect of the two-dimensional added mass. However, existing method is time-consuming with low accuracy in respect of global vibration analyses for vessels with large breadth. In this paper, to improve the demerit of the previous method, a new method of the beam-like ship vibration analysis is introduced In this method. the three-dimensional fluid added mass of surrounding water is calculated directly by solving the velocity potential problem using the Boundary Element Method (BEM). Then the three-dimensional added mass is evaluated as the lumped mass for each strip. Also, the beam-like ship vibration analysis for the structural beam model if performed with the lumped mass considered. It was verified that this new method is useful for the beam-like ship vibration analysis by comparing results obtained from both the existing method and the new method with experimental measurements for the open top container model.

  • PDF

Elastic Seismic Design of Steel Highrise Buildings in Regions of Moderate Seismicity (중진대 철골조 초고층 건물의 탄성내진설계)

  • Lee, Cheol Ho;Kim, Seon Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.553-562
    • /
    • 2006
  • Lateral loading due to wind or earthquake is a major factor that affects the design of high-rise buildings. This paper highlights the problems associated with the seismic design of high-rise buildings in regions of strong wind and moderate seismicity. Seismic response analysis and performance evaluation were conducted for wind-designed concentrically braced steel high-rise buildings in order to check the feasibility of designing them per elastic seismic design criterion (or strength and stiffness solution) in such regions. Review of wind design and pushover analysis results indicated that wind-designed high-rise buildings possess significantly increased elastic seismic capacity due to the overstrength resulting from the wind serviceability criterion. The strength demand-to-capacity study showed that, due to the wind design overstrength, high-rise buildings with a slenderness ratio of larger than four or five can elastically withstand even the maximum considered earthquake (MCE) with the seismic performance level of immediate occupancy under the limited conditions of this study. A step-by-step seismic design procedure per the elastic criterion that is directly usable for practicing design engineers is also recommended.