• Title/Summary/Keyword: Slabs

Search Result 1,125, Processing Time 0.028 seconds

Condition assessment of aged underground water tanks-Case study

  • Zafer Sakka;Ali Saleh;Thamer Al-Yaqoub;Hasan Karam;Shaikha AlSanad;Jamal Al-Qazweeni;Mohammad Mosawi;Husain Al-Baghli
    • Structural Engineering and Mechanics
    • /
    • v.90 no.5
    • /
    • pp.493-504
    • /
    • 2024
  • This paper presents the methodology and results for the investigation of the structural safety of 40 aged underground water tanks to support the weight of photovoltaic (PV) systems that were supposed to be placed on their roof reinforced concrete (RC) slabs. The investigation procedure included (1) review of available documents; (2) visual inspection of the roof RC slabs; (3) carrying out a series of nondestructive (ND) tests; and (4) analysis of results. Out of the 40 tanks, eleven failed the visual inspection phase and were discarded from further investigation. The roof RC slabs of the tanks that passed the visual inspection were subjected to a series of ND tests that included infrared thermography, impact echo, ultrasonic pulse velocity (UPV), Schmidt hammer, concrete core compressive strength, and water-soluble chloride content. The NDT results proved that eight more tanks were not suitable to support the PV systems. Based on the results of the visual inspection and testing, a probabilistic decision-making criterion was established to reach a decision regarding the structural integrity of the roof slabs. The study concluded that the condition of the drainage filter was essential in protecting the tanks and its intact presence can be used as a strong indication of the structural integrity of the roof RC slabs.

Punching Shear Strength in Thick Slabs (Thick Slab의 펀칭전단강도)

  • Kim, Woo;Kim, Dae-Joong;Lee, Jee-An
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.47-52
    • /
    • 1994
  • In designing of slabs, a prediction of the punching shear capacity is one of important concerns. In this study, an equation was proposed to predict the punching shear strength of reinforced concrete slabs. The proposed equation depends on concrete compression strength, steel ratio, effective depth and slab radial length. The good correlation exists between the predicted punching shear strength and the measured.

  • PDF

Fabrication of Concrete Slabs for Precast Pavement Construction (조립식 포장 시공을 위한 콘크리트 슬래브 제작)

  • Park, Hee-Beom;Kim, Seong-Min;Park, Won-Joo;Lee, Seung-Jae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.447-448
    • /
    • 2010
  • This study was conducted to investigate the feasibility of precast concrete slab fabrication. Slabs were designed including detailed element techniques, and based on the design, high performance precast slabs could be fabricated.

  • PDF

Crack Control Performance of the RC Composite Slabs Produced with Extruded ECC Panel (압출성형 ECC 패널을 이용한 RC슬래브의 균열제어성능)

  • Kim, Yun-Yong;Lee, Jong-Han;Cho, Chang-Geun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.95-96
    • /
    • 2010
  • This paper presents the crack control of reinforcement concrete composite slabs which were produced with the extruded ECC panel. Cracking control performance was evaluated based on the flexural tests on real scale one-way slabs manufactured with or without ECC panel.

  • PDF

Failure Analysis of Reinforced Concrete Slabs using Pseudo-Volume Control Method (의사체적제어법을 이용한 철근콘크리트 슬래브의 파괴거동 해석)

  • 심상효;송하원;최강룡;남상혁;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.577-582
    • /
    • 2000
  • The pseudo-volume control method is developed for the failure analysis of RC slabs, by adding pressure node into layered shell element utilizing in-plane constitutive models of reinforced concrete and layered formulation. For the failure analysis of RC slabs n this paper, geometric nonliearity is also considered in the analysis. The validity of the pseudo-volume control method is verified by comparing analysis results and existing experimental results.

  • PDF

Development of Probabilistic Prediction System for Remaining Life of Reinforced Concrete Bridge Decks (도로교 콘크리트 바닥판의 합리적인 수명 평가 및 예측시스템 개발)

  • 오병환;최영철;이준혁
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.637-640
    • /
    • 2002
  • The deterioration of RC deck slabs has been a serious problem and high portion of budget has been a spent for repair and strengthening of deck slab. The concrete deck slabs are subject to direct application of vehicle loading and accumulation of fatigue damage. Besides, various environmental causes. In this paper, an probabilistic study is carried out to predict exact load effects and structural capacity of deck slab during its service life, and estimate an appropriate remaining life of deck slab. To achieve this purpose the live load model is developed using by influence line including deterioration of deck slab, and deterioration model of bridge deck slab is developed. In addition, the fatigue life of reinforced concrete deck slabs considering corrosion of reinforcement are estimated based on experimental formula. This study will help rational decisions for the management and repair of reinforced concrete deck slabs.

  • PDF

Minimum Thickness Requirements of Flat Plate Considering Construction Scheme (시공 계획을 고려한 플랫 플레이트 최소 두께)

  • 강성훈;최경규;박홍근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.631-636
    • /
    • 2002
  • It is common in multistory flat-plate structures that newly cast slabs are supported by a number of previously cast floors. Then the weight of newly cast slabs is imposed on shored previously cast floors as load, and this load may be large as double as dead load. Because early-age construction loads cause large immediate deflection and creep deflection with cracks, this loads influence long-term behavior of slabs. In current provision, the minimum thickness is required to satisfy serviceability But this minimum thickness based on historical precedent is determined by span length, therefore the minimum thickness of current provision can not includes properly the effect of construction scheme including the number of shored floors and construction cycle. In the present study, a minimum thickness criterion, which includes the effect of concrete strength, geometry of slabs and construction scheme, was developed from computer-based iteration using deflection calculation procedure of current code method.

  • PDF

Long-term flexural cracking control of reinforced self-compacting concrete one way slabs with and without fibres

  • Aslani, Farhad;Nejadi, Shami;Samali, Bijan
    • Computers and Concrete
    • /
    • v.14 no.4
    • /
    • pp.419-444
    • /
    • 2014
  • In this study experimental result of a total of eight SCC and FRSCC slabs with the same cross-section were monitored for up to 240 days to measure the time-dependent development of cracking and deformations under service loads are presented. For this purpose, four SCC mixes are considered in the test program. This study aimed to compare SCC and FRSCC experimental results with conventional concrete experimental results. The steel strains within the high moment regions, the concrete surface strains at the tensile steel level, deflection at the mid-span, crack widths and crack spacing were recorded throughout the testing period. Experimental results show that hybrid fibre reinforced SCC slabs demonstrated minimum instantaneous and time-dependent crack widths and steel fibre reinforced SCC slabs presented minimum final deflection.

Formation Mechanism of Surface Crack and Its Control on Continuously Cast Slabs of Nb-containing Austenitic Stainless Steel (Nb 첨가 오스테나이트계 스테인레스강의 연속주조시 표면크랙 형성기구 및 제어)

  • Shim, Sang-Dae;Kim, Sun-Koo
    • Journal of Korea Foundry Society
    • /
    • v.21 no.5
    • /
    • pp.280-285
    • /
    • 2001
  • Nb-containing austenitic stainless steel is widely used as exhaust frame and diffuser assembly in power plant. However, this steel is known to be difficult to produce by the continuous casting process due to the surface cracks. Therefore, the continuous casting technology was developed for the prevention of the surface cracks on CC slabs. Precipitates and the analysis of heat trasfer in a slab were investigated in order to find out the formation mechanism of surface cracks on cc slabs It was found that surface cracks are occurred due to the NbC precipitates, which are formed along the grain boundaries around $800^{\circ}C$. The secondary cooling pattern has been developed to produce the defect free CC slabs of Nb-containing austenitic stainless steel.

  • PDF

Modified Equivalent Frame Models for Flat Plate slabs Under Lateral Load (수평하중을 받는 플랫 플레이트 슬래브 해석을 위한 수정된 등가골조모델)

  • Park Young Mi;Cho Kyung Hyun;Han Sang Whan;Lee Li Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.272-275
    • /
    • 2004
  • This study is to propose a modified equivalent frame method under lateral loading. ACI 318-02 allows the equivalent frame method to conduct slab analysis subjected to lateral loads. However, current method can not predict the behavior of the slabs particularly under lateral loading because the equivalent frame method in the ACI 318 has been developed against gravity loads. This study provides more precise model for the analysis of the flat plate slabs under lateral loading. The model reflect the force transfer mechanism of slabs, column and torsional member more accurately than the existing model. The accuracy of this model is verified by compared with finite element method analysis results.

  • PDF