• 제목/요약/키워드: Sky-Bridge

검색결과 32건 처리시간 0.021초

스카이브릿지를 이용한 RC 주거용 건물의 진동제어 (Vibration Control of RC Residential Building Structure Using Sky-Bridge)

  • 안상경;오정근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.450-453
    • /
    • 2006
  • Coupling adjacent building with supplemental damping devices is a developing method of reduced structural response due to wind and seismic excitations. The philosophy is to allow structures, vibrating at different frequencies, to exert control forces upon one another to reduce the overall responses of the system. This paper studies the effect of installing vibration control devices of two high rise building structures(49 stories and 42 stories) connected by sky-bridge. According to the analysis results the use of sky-bridge can be effective in increasing damping ratio of the system.

  • PDF

SKY-BRIDGE로 연결된 건물의 진동제어 (Vibration Control of Buildings Connected by a Sky-Bridge)

  • 류진국;김진구
    • 한국전산구조공학회논문집
    • /
    • 제17권2호
    • /
    • pp.203-213
    • /
    • 2004
  • 본 연구에서는 최상층에 설치된 연결교량과 두 건물의 연결부에 점탄성감쇠기 (Viscoelastic Dampers, VED)를 설치하여 지진에 의한 연결된 건물의 응답을 저감하는 방법에 대해서 연구하였다. 제안된 방법의 적용성을 백작잡음하중에 대한 2자유도계 구조물의 RMS (root-mean-squared) 응답을 통하여 검토한 후, 점탄성감쇠기의 크기변화에 따른 응답 감소 효과를 분석하기 위해 다양한 층수의 연결된 구조물에 대하여 지진응답 해석을 수행하고, VED 설치 전후의 최대변위, 소성힌지 분포, 잔류변위 등을 비교하였다. 해석결과에 따르면, 구조물의 응답을 최소화하는 점탄성감최기의 적정 크기가 존재하며, 연결된 두 구조물의 고유주기의 차이가 증가할수록 점탄성감쇠기의 진동제어 효과가 커진다는 것을 알 수 있다.

구조물의 고유진동주기 및 스카이브릿지 설치위치에 따른 진동특성평가 (Vibration Characteristics Evaluation According to Natural Periods of Structures and Location of a Sky-bridge)

  • 김현수
    • 한국산학기술학회논문지
    • /
    • 제14권6호
    • /
    • pp.3068-3073
    • /
    • 2013
  • 근래에 스카이브릿지를 활용하여 연결된 고층구조물의 진동제어성능을 개선하고자 하는 연구가 수행되고 있다. 본 논문에서는 스카이브릿지로 연결되는 두 구조물의 고유진동주기의 차이와 스카이브릿지 설치위치가 진동제어성능에 미치는 영향에 대해서 분석하여 보았다. 이를 위하여 40층과 50층 구조물을 연결된 예제구조물로 선택하였고 두 구조물의 고유진동주기 차이를 1.0배에서 1.5배까지 순차적으로 변경하면서 해석모델을 구성하였다. 각각의 해석 모델에 대하여 KBC2009를 기반으로 생성한 인공지진하중을 입력 하중으로 생성하여 시간이력해석을 수행하였다. 수치해석결과 두 구조물의 고유진동주기차이가 증가할수록, 연결된 층의 높이가 높아질수록 변위 및 속도응답에 대해서 일반적으로 우수한 제어성능을 나타내는 것을 알 수 있었다. 그러나 가속도응답의 경우에는 이러한 경향과 반대되는 제어성능변화를 나타내었다.

Innovative Design and Practice in Horizontal Skyscraper-ChongQing Raffles

  • Li-Gang, Zhu
    • 국제초고층학회논문집
    • /
    • 제11권3호
    • /
    • pp.197-205
    • /
    • 2022
  • One of important design challenges in Chongqing Raffles City Plaza project is Sky Bridge structural design and its connection scheme in high level. This article systematically describes the structural system and its design and analysis methodology, with discussing the impacts on structural performance due to different connection approaches. The seismic isolation scheme in high level is innovatively adopted to the final design. Under the conditions of various load cases, the different models and assumptions are implemented. A full assessment on Sky Bridge's structural performance, seismic isolation, and its connection is conducted in terms of seismic performance based design. By co-operating with architecture, MEP and other disciplines, the structural economy index is fulfilled.

인접건축물의 진동제어를 위한 MR감쇠기의 적용 (Application of MR damper for Vibration Control of Adjacent Buildings)

  • 김기철;강주원
    • 한국공간구조학회논문집
    • /
    • 제12권4호
    • /
    • pp.99-108
    • /
    • 2012
  • In recently, sky-bridge are often applied to high-rised adjacent buildings for pedestrian bridge. the seisnic response control of adjacent buildings have been studied and magneto-rheological(MR) fluid dampers have been applied to seismic response control. In this study, vibration control effect of the MR damper connected adjacent buildings has been investigated. Adjacent building structures with different natural frequencies were used as example structures. Two typed of control methods, displacement based or velocity based, are applied to determinate control force of MR damper. In this numerical analysis, it has been shown that displacement-based control algorithm is more effective than velocity-based control algorithm for seismic response control of adjacent buildings. And, when displacement-based control method is applied to control of adjacent buildings, the control of building occurred large displacement is more efficient in reducing the seismic response.