DOI QR코드

DOI QR Code

Application of MR damper for Vibration Control of Adjacent Buildings

인접건축물의 진동제어를 위한 MR감쇠기의 적용

  • Received : 2012.10.16
  • Accepted : 2012.11.30
  • Published : 2012.12.15

Abstract

In recently, sky-bridge are often applied to high-rised adjacent buildings for pedestrian bridge. the seisnic response control of adjacent buildings have been studied and magneto-rheological(MR) fluid dampers have been applied to seismic response control. In this study, vibration control effect of the MR damper connected adjacent buildings has been investigated. Adjacent building structures with different natural frequencies were used as example structures. Two typed of control methods, displacement based or velocity based, are applied to determinate control force of MR damper. In this numerical analysis, it has been shown that displacement-based control algorithm is more effective than velocity-based control algorithm for seismic response control of adjacent buildings. And, when displacement-based control method is applied to control of adjacent buildings, the control of building occurred large displacement is more efficient in reducing the seismic response.

Keywords

References

  1. Shinya Soma, Takashi Tanaka, Toru Watanabe and Kazuto Seto, 'Seismic response control for parallel building structures using MR damper', Nihon Kikai Gakkai Kanto Shibu Sokai Koen Ronbunshu, Vol. 10, 2004, pp. 225-232
  2. Seung-Yong Ok, Kwan-Soon Park and Hyun-Moo Koh, Optimal Design of Linear Viscous Damping System for Vibration Control of Adjacent Building Structures, Earthquake Engineering Society of Korea, Vol. 10, No. 3, pp.85-100. https://doi.org/10.5000/EESK.2006.10.3.085
  3. Hyun-Su Kim, Ah-Ram Yang, Dong-Guen Lee, Sang-Kyung Ahn and Jung-Keun Oh, Performance Evaluation of Vibration Control of High-rise Buildings Connected by Sky-bridge, Korea Association for Spatial Structures, Vol. 8, No. 4, pp. 91-100
  4. Hyun-Su Kim, Young-Koo Park, Hyun Ko, Ui-Hyun Lee and Dong-Guen Lee, Performance Evaluation of Vibration Control According to Installation Location of Sky-bridge, Korea Association for Spatial Structures, Vol. 10, No. 3, pp.65-74.
  5. Gee-Cheol Kim, Joo-Won Kang and Seung-Hoon Chae, Hybrid Control Model of MR Damper for Seismic Response Control of Adjacent Buildings, Korea Association for Spatial Structures, Vol. 11, No. 2, pp. 101-110.
  6. Sang-Hyun Lee, Kyung-Won Min, Roo-Jee Lee and Joong-Koo Kim, Preliminary Design Procedure of MR Dampers for Controlling Seismic Response of Building Structures, Earthquake Engineering Society of Korea, Vol. 8, No. 5, pp. 55-64. https://doi.org/10.5000/EESK.2004.8.5.055