• Title/Summary/Keyword: Skin probe

Search Result 79, Processing Time 0.03 seconds

Clinical In Vivo Bio Assay of Glucose in Human Skin by a Tattoo Film Carbon Nano Tube Sensor

  • Ly, Suw Young;Lee, Chang Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.595-601
    • /
    • 2017
  • In vivo assay of glucose detection was described using a skin tattoo film electrode (STF), and the probe was made from carbon nano tube paste modification film paper. Here in the square-wave stripping anodic working range obtained of $20-100mgL^{-1}$ within an accumulation time of 0 seconds only in sea water electrolyte solutions of pH 7.0. The relative standard deviations of 50 mg glucose that were observed of 0.14 % (n=12), respectively, using optimum stripping accumulation of 30 sec, the low detection limit (S/N) was pegged at 15.8 mg/L. The developed results can be applied to the detect of in vivo skin sensing in real time. Which confirms the results are usable for in vitro or vivo diagnostic clinical analysis.

Quantification of Melanin Density at Epidermal Basal Layer by Using Confocal Scanning Laser Microscope (CSLM) (Confocal Scanning Laser Microscope (CSLM)을 이용한 피부 기저층 멜라닌 밀도의 정량화)

  • Kim, Dong Hyun;Lee, Sung Ho;Oh, Myoung Jin;Choi, Go Woon;Yang, Woo Chul;Park, Chang Seo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.3
    • /
    • pp.259-268
    • /
    • 2014
  • Non-invasive technologies in skin research have enabled to use a live image of living skin without a biopsy or histologic processing of tissue. Confocal scanning laser microscope (CSLM) operated at a near-infrared wavelength of 830 nm allows visualization of inner structure of skin as a non-invasive manner. According to previous researches using CSLM, melanin cap and papillary ring were clearly observed in pigmented areas between stratum basale and papillary dermis. In this study, conversional analysis of CSLM digital images into numerical estimation using scanning probe image processor (SPIP) software was attempted for the first time. It is concluded that a quantification of CSLM images can pave way to expand the field of applications of CSLM.

Development of Quantitative Lymphedema Screening System to Monitor Change in Skin Elasticity through the Measurement of Indentation Force and Return Time (피부의 탄성변화에 따른 피부 가압과 복귀시간 측정을 통한 정량적 림프부종 진단 시스템 개발)

  • Seo, Jong Hyun;Cho, Chang Nho;Kim, Sung Chun;Chung, Seung Hyun;Koh, Eun Sil;Kim, Kwang Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.4
    • /
    • pp.170-176
    • /
    • 2013
  • Lymphedema is a phenomenon in which fluid is accumulated inside tissues due to the damaged lymphatic systems. Lymphedema can cause complications such as lymphangitis, infection, changes in skin texture, fibrosis, and lymphangiosarcoma. In this study, a lymphedema screening system based on the elasticity of the skin is proposed to easily quantify lymphedema. The developed probe consists of touch sensors, a load cell and hall-effect sensors to measure the indentation force on the skin and the return time of the skin. The developed system can be used to estimate the change in the elasticity of the skin to quantify lymphedema. The system was tested with a thyroid phantom and gelatin phantoms of different concentrations and the resulting force and the time were recorded. It was found that the increase in the elasticity leads to a higher indentation force and shorter return time. This shows that the developed system can monitor the change in the skin elasticity by measuring the return time and the indentation force. The feasibility of the system in clinical applications will be evaluated in the future study.

Skin-Mimicking Phantom for Measurment of Cosmetic Transdermal Absorption and Temperature Changes by Sonophoresis

  • Kim, Gahee;Jang, Hwijin;Choi, Seonmin;Park, Sanghyo;Kim, Woo Cheol;Key, Jaehong
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.271-279
    • /
    • 2022
  • Functional cosmetics containing various ingredients that improve skin health are currently being developed. In addition, technologies that help increase the absorption rate of such cosmetics have recently gained significant attention. Sonophoresis is a method to increase the transdermal absorption of cosmetics using ultrasound. A skin-mimicking phantom was fabricated using polydimethylsiloxane, Strat-MTM membrane, and thermochromic pigments. Gel-type cosmetics used in skin mask packs and epidermal-growth-factor-based nano-cosmetics were tested for their absorption rates at ultrasound frequencies of 1, 3, and 10 MHz in the single frequency mode, and 1/3 and 3/10 MHz in the dual frequency mode. The gel-type cosmetics and epidermal-grow-factor-based nano-cosmetics showed the highest absorption rate at 3/10MHz dual frequency. The size of the cosmetic particles decreased by 5-9 %. Furthermore, the temperature rise caused by ultrasound could be visually recognized by the thermochromic pigment in the phantom turning white. We presented a skin-mimicking phantom. The device can be customized according to the size of the ultrasound probe and has the advantage of quantitatively evaluating the transdermal permeability of cosmetics at a low cost. The development of the skin-mimicking phantom will be useful for determining the suitable conditions required to increase the absorption rate of cosmetics using ultrasound.

Lymphoscintigraphy for Intraopertive Sentinel Node Biopsy of Skin and Soft Tissue Malignancy (Lymphoscintigraphy와 전초 림프절 절제술을 이용한 피부 악성종양의 치험례)

  • Lee, Tae Hoon;Shim, Jeong Su;Jeong, Jae Ho
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.635-640
    • /
    • 2005
  • Sentinel lymphnode biopsy is widely performed in the management of malignant melanoma and breast cancer. The sentinel lymphnode is the prime site of draining from the malignant lesion and of metastasis. The aim of this study was to evaluate a usefulness of lymphoscintigraphy in conjunction with a removal of sentinel lymphnodes of skin and soft tissue malignancy. We studied 11 patients selected between January, 2003 and November, 2004. Clinically sentinel lymphnodes free of metastasis were examined with lymphoscintigraphy, gamma detection probe and vital dye staining, and we reviewed histopathologic findings and inert status of the nodes and the results fo treatment. Nine cases were malignant melanoma, one was squamous cell carcinoma on the left hand and another one leiomyosarcoma. Sentinel lymphnodes were identified in all cases. Three cases of malignant melanoma had positive sentinel lymphnodes on histological examination. All patients with positive sentinel lymphnodes were treated with therapeutic regional lymphadectomy, chemotherapy and adjuvant regimen. Four patients underwent PET scanning and followed sentinel lymphnode biopsy. Two had no metastasis signs on PET scanning. Therapeutic lymphnode dissection was carried out upon the patients whose sentinel lymphnode was positive on PET scanning. We contend that lymphoscintigraphy and sentinel lymphnode biopsy are reliable to confirm regional lymphnode metastasis of the skin and soft tissue malignancy, and blind extensive lymphnode dissection can be spared.

Ring type non-invasive glucose sensor (민감도가 향상된 링 형태의 비 침습식 혈당 센서)

  • Lee, Ki-Hyuck;Lee, Kook-Joo;Lee, Dong-Ho;Kim, Moon-Il;Park, Gil-Hong
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.293-296
    • /
    • 2007
  • A novel sensitive and non-invasive ring-type glucose probe was designed and measured. The magnitude and phase of return loss change with different concentration of the glucose solution inside the loop structure. Ring type probe is more advantageous than open ended probe to measure electrical characteristics under the skin. The maximum difference of return loss was 0.94 for the concentration difference of 0% and 20% at 285MHz and more sensitive in low frequency.

  • PDF

Changes in Hydrophobic Surface of Collagen by Chondroitin Sulfate : Fluorescence Intensity Measurements with Bis-ANS as the Probe

  • Kim, Sung-Koo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.3
    • /
    • pp.446-453
    • /
    • 1995
  • The improtant components of extracellular matrix(ECM) are collagen and chondroitin sulfate. The hydrophobic surface of collagen is one of the determining factors of diameter of collagen fiber and also is closely related to the aging phenomena. The controlling mechanism of the diameter of collagen fiber influenced by the interaction with chondroitin sulfate was evaluated using bis-ANS as a hydrophobic probe. Hydrophobic surface area of collagen molecule shielded by chondroitin sulfate was evaluated. Relative fluorescence intensity of collagen in thepresence of chondroitin sulfate was measured using bis-ANS as a hydrophobic probe. The fluorescence intensity decreased with the increase in chondroitin sulfate up to 3.8 chondroitin sulfate/collagen(mole/mole). Further increase in the ratio of chondroitin sulfate to collagen did not change the fluorescence intensity. Similar changes in the relative fluorescence intensity were observed for both rat tail and lathyrific rat skin collagen. The fluorescence intensity indicated by the binding between bis-ANS and hydrophobic sites of collagen was pH dependent, and the shielding effect of collagen-chondroitin sulfate interaction could not be detected at pH above 6.0. This is probably due to the charge repulsions caused by negative charged collagen molecules at higher pH.

  • PDF

Analyse of characteristic of Eddy current sensor using Boundary Element Method (경계요소해석을 이용한 와전류 센서의 특성 해석)

  • Yoon, Man-Sik;Choi, Duck-Su;Yang, Gyu-Chang;Lee, Hyang-Beom;Park, Seung-Han
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.697-699
    • /
    • 2002
  • In this paper, the characteristics analysis of the eddy current sensor by using boundary element method package is presented. For the boundary element analysis. Faraday, which is the commercial package of the integrated engineering software, is used. To observe the impedance characteristic of the eddy current senor with the sensor position and lift-off, the eddy current testing analysis is performed on the ferromagnetic plate with defect. Considering the skin depth of the ferromagnetic specimen, the 800(Hz) driving source is chosen. The result shows that electro motive force is reduced as the probe moves to near the defect and the lift-off of the probe increases.

  • PDF

Study for increase of Light Transmission by applying Pressure (압력을 이용한 광선 투과도 증가에 대한 연구)

  • Yeo, Chang-Min;Son, Tae-Yoon;Jung, Byung-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.151-152
    • /
    • 2008
  • Laser has been applied in various diagnostic and therapeutic medical fields. For last few decades, medical low-level laser devices have been introduced in market, but they have limitations which cannot convey enough energy to deep layer of tissues for diagnostic or therapeutic purposes. To address the issue, there have been many studies of using physical and chemical methods; it is one of ways to apply negative or positive pressure to tissue. However, it is hard to apply desired pressure on tissues continuously when practical laser devices arc used. In this study, we introduce a low-level laser probe which allows maintain pressure on skin tissue. Consequently, we are confident that the pressure probe for low-level laser treatment should be a useful tool in order to deliver sufficient energy for practical uses.

  • PDF

STARTLE AND ORIENTING REFLEX COMPONENTS MODULATION BY ATTENTION TO TASK AND PERFORMANCE OF MENTAL TEST WITH NOISE FOREGROUND (백색소음하에서 단어암기 및 재인검사 수행시의 경악 및 정향반사 특성 : 스트레스/정서연구에의 시사점)

  • Estate Sokhadze
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.03a
    • /
    • pp.139-145
    • /
    • 1999
  • In current study on 8 college students there was examined modulation of eyeblink (as measured by integrated EMG of m.orbicularis oculi) and skin conductance response (SCR) to an acoustic startle probe (85 dB[A] white noise) by attending to task presented in auditory modality (to memorize words for further recognition) and entire performance of the word recognition test. Both eyeblink magnitude and SCR amplitude and rise time to startle probes were modified (larger magnitude of EMG peak, lower amplitude and shorter rise time of SCR) during attending to task as compared to performance on test. Results are interpreted n terms of modification of electrodermal and eyeblink components of startle and orienting reflexes by task characteristics (passive versus active efforts), attentional demands and aversiveness of experimental situation. However, eyeblink startle response manifested potentiation during attending to task, while SCR demonstrated attenuation. There are discussed implications of startle modulatioas a potentially sensitive probe of situational demands in stress research and also are considered prospects for further studies.

  • PDF