• 제목/요약/키워드: Skin Irritation

검색결과 328건 처리시간 0.027초

Skin Corrosion and Irritation Test of Nanoparticles Using Reconstructed Three-Dimensional Human Skin Model, EpiDermTM

  • Kim, Hyejin;Choi, Jonghye;Lee, Handule;Park, Juyoung;Yoon, Byung-Il;Jin, Seon Mi;Park, Kwangsik
    • Toxicological Research
    • /
    • 제32권4호
    • /
    • pp.311-316
    • /
    • 2016
  • Effects of nanoparticles (NPs) on skin corrosion and irritation using three-dimensional human skin models were investigated based on the test guidelines of Organization for Economic Co-operation and Development (OECD TG431 and TG439). EpiDerm$^{TM}$ skin was incubated with NPs including those harboring iron (FeNPs), aluminum oxide (AlNPs), titanium oxide (TNPs), and silver (AgNPs) for a defined time according to the test guidelines. Cell viabilities of EpiDerm$^{TM}$ skins were measured by the 3-(4, 5-dimethylthiazol-2-yl)-2.5-diphenyltetrazolium bromide based method. FeNPs, AlNPs, TNPs, and AgNPs were non-corrosive because the viability was more than 50% after 3 min exposure and more than 15% after 60 min exposure, which are the non-corrosive criteria. All NPs were also non-irritants, based on viability exceeding 50% after 60 min exposure and 42 hr post-incubation. Release of interleukin 1-alpha and histopathological analysis supported the cell viability results. These findings suggest that FeNPs, AlNPs, TNPs, and AgNPs are 'non-corrosive' and 'non-irritant' to human skin by a globally harmonized classification system.

Evaluation of Irritating Potential of Newly Developed Toothpaste in the Hamster Oral Mucous Membrane

  • Kim, Bae-Hwan;Kim, Jin-Woo;Chang, Ih-Seop;Sim, Young-Chul;Lee, Yong-Soon
    • Toxicological Research
    • /
    • 제17권3호
    • /
    • pp.167-171
    • /
    • 2001
  • Oral mucous membrane test using Syrian hamsters was performed to evaluate the reliability as a model system for the assessment of the potentially irritating substances intended for the mucous membranes, and to determine the irritating potential of a new emulsion-type formulated toothpaste. After test substances were implanted into the cheek pouches of hamsters with diluents (20 mg/kg) under pento-barbital sodium anesthesia, we made the comparison in irritation between emulsion-type and dispersion-type of triclosan (TCS) formulations in the range of 0.2% to 0.3%. The emulsion-type formulations using non-ionic surfactant showed less mucosal lesion than other commercial toothpastes with 0.3% TCS, or dispersion-type ones. However, no significant difference in irritation was detected between 0.2% and 0.3% TCS. We report that this hamster cheek pouch method could be a reliable approach for the evaluation slight difference in the irritating potentials of cosmetics and hygiene products intended for the lips or other mucous membranes, and this method showed that the new emulsion-type formulation significantly lowered the TCS-induced toxicity, compared with other commercial toothpastes.

  • PDF

초음파 투과성 매질들의 여러 특성에 관한 연구 (The study was to analyze the effect of various ultrasound transmission media)

  • 강군용;김영배
    • 대한물리치료과학회지
    • /
    • 제9권4호
    • /
    • pp.185-192
    • /
    • 2002
  • Ultrasound has been found useful as a therapeutic modality for the reduction of muscular and tendinous spasm. It has also been utilized for pain and other pathologic conditions through the ability of soundwaves to introduce molecules of chemical substances through the skin by a process. Choice of the transmission medium is very important for effective ultrasound treatment in clinical field. The purpose of this study was to analyze the effects of various ultrasound conduction media in regard to ultrasound conductivity and degree of absorption, evaporation and of skin irritation. The media used in this study were Antiphlamine, Sacch lotion, Stereogel, Trastgel, Antiphlamine S lotion, and Mentholatum lotion that have been used in clinical medicine. The study revealed that Antiphlamine was not compatible with a good ultrasound transmitter. Other media excluding Antiphlamine were compatible with a good ultrasound conductor, but they had some drawback with their nature of higher absorption, evaporation and skin irritation. The medium that was prepared by mixing of Antiphlamine with Gel in 1 to 10 ratio was a good ultrasound transmitter and extents of absorption and evaporation and of skin irritation of it were less than the other media.

  • PDF

Study on hair dryer thermal vibration massage to make shaving more comfortable

  • Tian, Zhixing;You, Kwang-Bock;Bae, Myung-Jin
    • International Journal of Advanced Culture Technology
    • /
    • 제9권2호
    • /
    • pp.123-129
    • /
    • 2021
  • When shaving, it is easy to suffer shaving burns, that is, facial burn irritation during shaving. The reason is that the razor blade irritates the skin. The current solution is to make the razor sharper and use a razor with a blade heating function. Although these ways can increase the comfort of shaving, they will also greatly increase shaving costs. This paper proposes using a hairdryer to massage the skin before shaving to reduce skin irritation during shaving. This is a simple, practical and low-cost method. The hair dryer's heat, sound, and wind energy have a massage effect, and they can make shaving easier and more comfortable. For analyzing shaving effect, two evaluation methods are used, which are sound spectrum analysis and mos. The sound spectrum analysis is used to analyze the working status of the razor objectively. The MOS test can reflect the subjective feelings of the subject on the shaving's comfort. The results show that the hairdryer thermal vibration massage can make the beard easier to cut, thereby reducing the irritation of the razor to the skin and improving shaving comfort.

Cumutative skin irritation test of marine elastine in rabbit

  • Kim, Yun-Jung;Kim, Ki-Sung;Yun, Won-Jong;Kim, Kap-Ho;Kim, Eun-Ae;Lee, Jong-Sung;Kang, Jong-Koo;Kim, Su-Hyon
    • 한국환경성돌연변이발암원학회:학술대회논문집
    • /
    • 한국환경성돌연변이발암원학회 2004년도 춘계학술대회
    • /
    • pp.137-137
    • /
    • 2004
  • PDF

코지산을 함유한 폴록사머 겔 제제의 약물방출 및 피부자극성 (Drug Release and Skin Irritancy of Poloxamer Gel Containing Kojic Acid)

  • 박은우;조성완;김동섭;최기환;최영욱
    • Journal of Pharmaceutical Investigation
    • /
    • 제28권3호
    • /
    • pp.177-183
    • /
    • 1998
  • Low toxicity, reverse thermal gelation and high drug loading capabilities suggest that poloxamer 407 gels have great potential as a topical drug delivery system. Kojic acid (KA) is an antimelanogenic agent which has been widely used in cosmetics to whiten the skin color. However, it has the drawbacks of skin irritancy due to its acidic pH. Poloxamer gels of different polymer contents were formulated to overcome the problem and compared to the cream type formulations of either w/o/w multiple emulsion cream or o/w type emulsion cream. Using Franz diffusion cells mounted with a synthetic cellulose membrane (MWCO 12,000), drug release characteristics of the formulations were evaluated by the HPLC assay of KA concentration in the receptor compartment of pH 7.4 phosphate buffered saline solutions. Drug release from w/o/w multiple emulsion cream was controlled by oil membrane, showing the apparent zero order release kinetics. The KA release from the poloxamer gels was also controlled by the gel matrix, showing that drug release increased linearly as KA contents increase, but decreased exponentially as the polymer contents increase. In the skin irritancy test, the primary irritancy index(PII) of poloxamer gel base was lower than those of multiple emulsion cream base and o/w cream. Depending on KA contents or polymer contents in the gel. PH values in poloxamer gels were ranged from 1.3 to 2.0, which are interpreted as low or negligible irritation on skin. There was a good correlation between the log value of flux in drug release and PII value in skin irritation. It was possible to conclude that the poloxamer gels containing KA might be a good candidate for an antimelanogenic topical delivery system by virtue of the controlled release of the drug and the reduced skin irritancy.

  • PDF

유기농업자재 중 님과 고삼 추출물의 피부 및 안점막자극성 (Evaluation of Skin & Eye Irritation of Plant Extracts, Neem and Sophora)

  • 오진아;최진희;최미선;김진효;백민경;박경훈;유아선;이제봉;김두호
    • 농약과학회지
    • /
    • 제17권4호
    • /
    • pp.478-481
    • /
    • 2013
  • 본 연구는 병해충 관리용 유기농업자재 허용물질로 지정된 식물추출물 중 님 추출물(미얀마산, 인도산)과 고삼추출물(중국산)의 독성 평가를 위해 피부자극성과 안점막자극성시험을 수행하였다. 시험결과, 원산지가 다른 님 추출물 2종은 모두 피부자극성과 안점막자극성이 없는 것으로 평가되었고, 고삼 추출물은 피부자극성은 없었고 안점막자극성이 강도로 나타났으나 시간이 경과함에 따라 자극이 경감하는 것으로 평가됐다. 따라서 안점막자극성이 강한 것으로 평가된 고삼 추출물을 유기농업자재로 사용할 때 농작업자에 대한 안전대책이 필요한 것으로 판단된다.

농약 품목에 대한 GHS 기준과 농진청 기준에 따른 자극성 산출 후 자극성 분류 차이 비교 (Comparison of Differences between the Results of Irritation Classification after Irritation Calculation with GHS Criteria and RDA Directives in Plant Protection Products)

  • 유아선;오진아;박수진;조유미;이제봉;이난희;이주연;임양빈
    • 농약과학회지
    • /
    • 제20권4호
    • /
    • pp.326-340
    • /
    • 2016
  • 농약의 원제에 대한 GHS 체계 도입에 따라 농약 품목에 대한 GHS 도입 필요성이 대두되고 있어 GHS 도입 시 현행과의 평가 기준을 비교하였다. 농약 59 품목의 독성시험성적에 대하여 농약관리법과 GHS에 따라 피부자극성 및 안점막자극성을 산출 및 분류한 결과, 피부자극성 경도 및 중도로 분류된 품목에서 GHS 기준에 의해 '분류되지 않음'으로 구분된 품목이 전체의 25.5%였고 안점막자극성 경도에서 GHS 기준에 의해 '분류되지 않음'으로 구분된 품목이 45.8%로 나타나 자극성 구분이 완화되었다. 반면 비가역적 반응의 평가에 의해 경도와 중도에서 피부자극성이 피부부식성 구분 1로 보다 높게 평가된 품목이 6.8%, 안점막자극성이 심한 눈손상 구분 1로 보다 높게 평가 된 품목이 5.1%였다. 농약 품목의 시험성적을 이용한 GHS 분류와 품목에 함유된 원제의 자극성 구분과 함유량을 이용하여 GHS 혼합물 분류기준에 따라 분류한 결과를 비교한 결과, 피부자극성에서는 25.5% 품목의 자극성 구분이 완화되었고, 3.4% 품목의 자극성 구분이 강화되었다. 안점막자극성에서는 25.4%의 품목에 대한 자극성 구분이 완화되었고 11.9%의 품목의 자극성 구분이 강화되었다. 농약 품목에 GHS를 도입할 경우, 상이한 분류 결과를 보완할 수 있는 방안 마련이 필요하다고 사료된다.

홍삼가수분해농축액(GS-E3D)의 피부 안전성 평가 (Skin Safety Evaluation of Pectin Lyase-modified Red Ginseng Extract (GS-E3D))

  • 표미경;이경희;차선우;박기용;이기무
    • 생약학회지
    • /
    • 제49권3호
    • /
    • pp.246-254
    • /
    • 2018
  • Pectin lyase-modified red ginseng extract (GS-E3D) is a newly developed ginsenoside Rd-enriched ginseng extract. This study was designed to investigate the skin safety of GS-E3D. Single oral toxicity, single dermal toxicity, bovine corneal opacity and permeability (BCOP) assay, skin irritation test with $SkinEthic^{TM}$ human epidermis model, skin sensitization local lymph node assay, and human patch test, were examined. The oral and dermal $LD_{50}$ value of GS-E3D was over 2,000 mg/kg in rats. GS-E3D was identified as a non-irritant to skin in BCOP assay, human epidermis models, and patch test from the 32 human subjects. The skin sensitization potential of GS-E3D was less than 25% in local lymph node assay. These results indicate that GS-E3D can be used as a safe ingredient without adverse effects in various skin care products.

YHB216의 토끼에서 국소독성시험 및 마우스에서 소핵시험 (Study on Local Irritation in Rabbits and Micronucleus Test in Mice with YHB216)

  • 강민정;김미영;박명규;김봉태;안경규;최연식;문병석;이종욱
    • Toxicological Research
    • /
    • 제18권1호
    • /
    • pp.79-85
    • /
    • 2002
  • YHB216 is one of new recombinant human erythropoietins (rHu-EPO) developed by Yuhan Research Institute. The rHu-EPO products are widely being used for the treatment of various types of anemia. As a series of safety studies on YHB216, we performed the local irritation test (dermal & ocular application) in male New Zealand White rabbits and micronucleus test in male ICR mice. In the skin irritation test, 0.5 ml of YHB216 10,000 IU/ml solution was applied to the back skin of rabbits for 24 hours and sub-sequent observation was performed. There was no induced response after the treatment and the primary irritation index (P.I.I.) was‘0’. In the eye irritation test, 0.1 ml of YHB216 10,000 IU/mL solution was instilled into the conjunctiva of the eye. No treatment-related reaction was observed at the cornea, iris, and conjunctiva. In the micronucleus test, YHB216 was administered intravenously to male mice (6 mice per group) at dose levels of 0, 6,250, 12,500, and 25,000 IU/kg. Bone marrow cells were collected at 24 hours after the treatment. YHB216 treated groups showed no significant difference in the P/N (polychromatic erythrocyte/ normochromatic erythrocyte) ratio and in the number of micronucleated polychromatic erythrocyte com-pared with the control. In conclusion, YHB216 was found to be a non-irritating material up to 10,000 IU/ml in the local irritation test and to be a non-mutagen up to 25,000 IU/kg in the micronucleus test.