• 제목/요약/키워드: Size and Number Concentration

검색결과 474건 처리시간 0.031초

입원서비스의 집중화 수준과 진료비 간의 관계 분석: 2009년~2011년 (A study on the relationship between the concentration status of inpatient services and medical charges per case between 2009 and 2011)

  • 곽진미;이광수;권혁준
    • 지식경영연구
    • /
    • 제16권1호
    • /
    • pp.209-224
    • /
    • 2015
  • Previous studies provided that limiting the number of services provided in hospital had influences in decreasing cost in delivering medical services. Hospitals could have positive effects on their profit by concentrating small number of services which they have comparative advantages. This study purposed to analyze the relationship between the concentration status of hospitals and medical charge for inpatients. National Inpatient sample data provided by the Health Insurance Review and Assessment Service (HIRA) for three years, 2009 to 2011 was used to compute the three concentration indices (Information Theory Index (ITI), Internal Herfindahl Index (IHI), and number of distinct Diagnosis-Related Groups (DRGs) treated) and total medical charge per inpatient case in each year. It was also used to select the control variables such as bed size, number of doctors per 100 beds, and locations. The ordinary least square regression models were developed and tested for hospital and general hospitals separately. The results showed that the total medical charge per inpatient case was significantly differed depending on the concentration indices, and there were positive relationships in ITI and IHI. The number of distinct DRGs had different directions in regression coefficients depending on the locations and hospital types. Hospitals had larger absolute standardized regression coefficients compare to those of general hospitals. However, their effects could be varied by the hospital types, number of doctors, and locations. It seems that hospitals have more influences on medical charges by concentrating their services than general hospitals. Study results provide knowledges to hospital administrators that concentration strategy can positive influences on the performance of small size hospitals.

TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109, HCT Particle Sensor 3030을 이용한 PM2.5 측정결과 비교 (Comparison Study of the TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109 and HCT Particle Sensor 3030 for PM2.5 measurement)

  • 김두용;정혁;박재홍;현준호;황정호
    • 한국입자에어로졸학회지
    • /
    • 제8권1호
    • /
    • pp.9-15
    • /
    • 2012
  • Three different commercial particle counters were used to measure the PM2.5 particles in this study. An Aerosol Spectrometer (AS) 1.109 model of Grimm and a Particle Sensor (PS) 3030 model of HCT were compared with an Aerodynamic Particle Sizer (APS) 3321 model of TSI. The responses of these instruments were compared for four sizes ($1.0{\mu}m$, $1.5{\mu}m$, $2.0{\mu}m$ and $2.5{\mu}m$) of polystyrene latex (PSL) particles and indoor air particles of the office room. The mode diameter, particle size distribution and total particle number concentration of PSL particles were measured by each instrument. In the office room, the total particle number concentration was measured for 25 minutes. In results of particle size distribution and mode diameter, the APS 3321 (52 size-channels) was more accurate than the AS 1.109 (31 size-channels) and PS-3030 (10-szie channels) since the APS has more number of size-channels than the other instruments. However, AS 1.109 and PS-3030 provided similar results of total particle number concentration to those from the APS 3321. In results of office room test, there were no significant difference from each instrument similar to results of PSL test.

OPC(광학적 입자 계수기)로 측정한 2001년 서울지역 에어로졸의 입경 분포 (Characteristics of Aerosol Size Distribution from OPC Measurement in Seoul, 2001)

  • 정창훈;전영신;최병철
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.515-528
    • /
    • 2003
  • The characteristics of one year observation aerosol data in Seoul, 200 I was studied using an OPC (Optical Particle Counter). The size resolved aerosol number concentrations of 0.3 ∼ 25 11m were measured. The results were compared with PM$_{10}$ mass concentration data under various meteorological conditions including dust and precipitation events. For fine particles whose diameter is less than 2.23 ${\mu}{\textrm}{m}$, the number concentration increases in the early morning which is considered due to transportation. while the coarse mode particles increase during daytime. This increase can be explained as local sources and human activities near sampling site. Hourly averaged data show that there exists diurnal variation. Generally, PM$_{10}$ data showed a similar tendency with OPC data. The size resolved OPC data showed that the particles of 0.5 ∼ 3.67 ${\mu}{\textrm}{m}$ are positively correlated with PM$_{10}$ data. The accumulated volume fraction of size resolved aerosol concentration in 0.5 ∼ 10 ${\mu}{\textrm}{m}$ showed that 0.5 ∼ 2.23 ${\mu}{\textrm}{m}$ particles occupied 59.2% of total aerosol volume of 0.5 ∼ 10 ${\mu}{\textrm}{m}$./TEX>.

이어도 해양종합과학기지에서의 3차원 바람성분에 따른 에어로솔 수 농도 변동 특성 (The Variation of Aerosol Number Concentrations in Relation with 3D Wind Components in the Ieodo Ocean Research Station)

  • 박성화;장상민;이동인;정운선;정종훈;정성아;정창훈;김경식;김경익
    • 대기
    • /
    • 제22권1호
    • /
    • pp.97-107
    • /
    • 2012
  • To investigate variation of aerosol number concentration at each different size with three-dimensional (3D) wind components in ocean area, aerosol particles and 3D wind components were measured in the Ieodo Ocean Research Station, which is located to 419 km southwest from Marado, the southernmost island of Korea, from 25 June to 8 July 2010. The Laser Particle Counter (LPC) and ultrasonic anemometer were used to measure the size of aerosol particles and 3D wind components (zonal (u), meridional (v), and vertical (w) wind) respectively. Surface weather chart, NCEP/NCAR reanalysis data and sounding data were used to analyze the synoptic condition. The distribution of aerosol number concentration had a large variation from bigger particles more than 1.0 ${\mu}m$ in diameter by wind direction during precipitation. In the number concentration of aerosol particles with respect to the weather conditions, particles larger than 1.0 ${\mu}m$ in size were decreased and sustained to the similar concentration at smaller particles during precipitation. The increase in aerosol number concentration was due to the sea-salt particles which was suspended by southwesterly and upward winds. In addition, the aerosol number concentration with vertical wind flow could be related with the occurrence and increasing mechanism of aerosol in marine boundary layer.

디젤 입자상물질의 크기분포 특성에 관한 실험적 연구 (Experimental Study on the Size Distribution of Diesel Particulate Matter (DPM))

  • 연익준;권순박;이규원
    • 환경위생공학
    • /
    • 제17권2호
    • /
    • pp.11-17
    • /
    • 2002
  • Diesel particulate matter (DPM) is known to be one of the major harmful emissions produced by diesel engines. The majority of diesel particles are in the range of smaller than $I{\mu}\textrm{m}$. Because of their tiny volume, ultrafine diesel particles contribute very little to the total mass concentration which is currently regulated for automobile emissions. Diesel particles are known to have deleterious effects upon human health because they penetrate human respiratory tract and have negative effects on the health. The measurement of the number distribution of nanometer size particles (nanoparticles) in the diesel exhaust emission is important in order to evaluate their environmental and health impact, and to develop new types of diesel particulate filters. In this study, we directly sampled particulate matters emitted from a diesel truck mounted on the chassis dynamometer by a flow separator and dilution system, and measured the nanoparticles using two types of differential mobility analyzers combined with a Faraday cup electrometer (FCE) and a condensation particle counter (CPC). The particle size distributions were analyzed by changing engine operation condition, i.e. ratio of engine loading. The total number concentration of particles were increased with the engine loading ratio and the nanoparticles (less than 50nm) were affected by hydrocarbon (HC) concentration in the diesel exhaust.

Anodic Oxidation Behavior of AZ31 Magnesium Alloy in Aqueous Electrolyte Containing Various Na2CO3 Concentrations

  • Moon, Sungmo;Kim, Yeajin
    • 한국표면공학회지
    • /
    • 제49권4호
    • /
    • pp.331-338
    • /
    • 2016
  • In this work, anodic oxidation behavior of AZ31 Mg alloy was studied as a function of $Na_2CO_3$ concentration in electrolyte by voltage-time curves and observation of surface appearances and morphologies after the anodic treatments, using optical microscopy and confocal scanning laser microscopy (CSLM). The voltage-time curves of AZ31 Mg alloy surface and surface appearances after the anodic treatments showed three different regions with $Na_2CO_3$ concentration : region I, below 0.2 M $Na_2CO_3$ where shiny surface with a number of small size pits; region II, between 0.4 M and 0.6 M $Na_2CO_3$ where dark surface with relatively low number of large size burned or dark spots; region III, more than 0.8 M $Na_2CO_3$ where bright surface with or without large size dark spots were obtained. The anodically treated AZ31 Mg alloy surface became significantly brightened with increasing $Na_2CO_3$ concentration from 0.5 M to 0.8 M which was attribute to the formation of denser and smoother surface films. Pits and porous protruding reaction products were found at relatively large size and small size spots, respectively, on the AZ31 Mg alloy surface in low concentration of $Na_2CO_3$ less than 0.2 M. The formation of pits is attributed to the result of repetition of the formation and detachment of porous anodic reaction products. Based on the experimental results obtained in this work, it is concluded that more uniform, denser and smoother surface of AZ31 Mg alloy could be obtained at more than 0.8 M $Na_2CO_3$ concentration if there is no other oxide forming agent.

광도가 서울 대기의 오존 생성 및 에어로졸 수 농도에 미치는 영향 (Effect of light intensity on the ozone formation and the aerosol number concentration of ambient air in Seoul)

  • 배귀남;박주연;김민철;이승복;문길주;김용표
    • 한국입자에어로졸학회지
    • /
    • 제4권1호
    • /
    • pp.9-20
    • /
    • 2008
  • The effect of light intensity on the ozone formation and the aerosol number concentration during the photochemical reactions of ambient air was investigated in an indoor smog chamber. The smog chamber consists of a housing, 64 blacklights, and a $2.5-m^3$ reaction bag made of Teflon film. The bag was filled with the unfiltered ambient air in Seoul from January 10 to March 18, 2002. In this work, the photolysis rate of $NO_2$, $k_1$ was used as an index of light intensity. Three levels of light intensity were controlled by changing the number of blacklights turned on among 64 blacklights: $0.29min^{-1}$ (50%), $0.44min^{-1}$ (75%), $0.57min^{-1}$ (100%). The ozone concentration increased rapidly within 10 minutes after irradiation irrespective of light intensity, thereafter it increased linearly during the irradiation. The ozone production rate seems to be dependent on both the light intensity and the quality of ambient air introduced into the reaction bag. The change in aerosol number concentration also depended on both the light intensity and the ambient air quality, especially aerosol size distribution. Based on the initial ambient aerosol size distributions, the photochemical potential for aerosol formation and growth is classified into two cases. One is the case showing aerosol formation and growth processes, and the other is the case showing no apparent change in particle size distribution.

  • PDF

디젤기관 배기 배출물에 있어서 매연 응집체 크기 및 농도의 시간적 계측에 관한 연구 (A Study on Temporal Measurement of Size and Concentration for Soot Aggregates among Exhaust Emissions in Diesel Engines)

  • 배명환;;배창환
    • 한국자동차공학회논문집
    • /
    • 제15권1호
    • /
    • pp.116-124
    • /
    • 2007
  • An optical method to measure the size and number density of soot aggregates in diesel exhaust has been proposed in this study. Two laser beams in co-axial alignment transmit a soot loaded exhaust gas flow, and the transmittance at each wavelength is detected by a photo diode simultaneously. The volume equivalent diameter and number density of soot aggregates in the optical path can be theoretically given by the transmittance values measured at two wavelengths. A test conducted by a single cylinder, 4 cycle, small and DI diesel engine shows that the temporal variations of the size and number density of soot aggregates in the diesel exhaust can be measured by the proposed method at a transient mode operation. It is found that the volume equivalent diameter varied temporally from 70 to 110 nm during the period that high soot concentration is observed. One can also conclude that the optical length longer than 1 m in the dynamic range regarding this method is preferable for measuring soot concentration at the level of $1\;mg/m^3$.

용융 알루미늄내에서 개재물의 크기분포 및 농도측정에 관한 연구 (A Study on the Measurement of the Concentration and the Size Distribution of Inclusions in the Molten Aluminum)

  • 안정;문광호;이광학
    • 한국주조공학회지
    • /
    • 제14권1호
    • /
    • pp.62-74
    • /
    • 1994
  • The concentration and particle size distribution of non-metallic inclusions which suspended in the molten aluminum at $700^{\circ}C$ were measured by using LiMCA apparatus. The result revealed that the number of inclusions increased with increasing the applied current or decreasing the orifice diameter, while decreased with increasing the purity of aluminum. And also, it was found that the number of inclusions increased with increasing the amount of boron added to molten aluminum. This was found to be attributed to the formation of the inclusions of TiB and $V_3B_2$. It was investigated that the average concentration of inclusions in a constant volume of 20ml of molten aluminum was increased in the order of pure molten aluminum, molten aluminum containing 20ppm of boron and molten aluminum used repeatly in the experimental casting in this study.

  • PDF

제주 고산 지역의 에어러솔 수농도 변동과 기상요소와의 상관성 연구 : 2001-2003 (Relationship between Meteorological Elements and Aerosols Number Concentration at Gosan, Jeju for $2001{\sim}2003$)

  • 이명주;오성남;김은연;장기호
    • 한국방재학회 논문집
    • /
    • 제6권3호
    • /
    • pp.47-56
    • /
    • 2006
  • 기후변화와 관련한 한반도 배경대기의 에어러솔에 대한 특성 연구는 관측된 입자 수농도와 대기 복사 관측 자료를 바탕으로 에어러솔의 물리적, 화학적 및 광학적 특성에 대하여 분석하였다. 에어러솔의 물리적 특성 연구는 2001년부터 2003년까지 제주도 고산관측소에 설치된 광학입자계수기(Optical Particle Counter, OPC)로 $0.3{\sim}25{\mu}m$직경의 에어러솔을 8개 구간으로 나누어 관측하여 분석하였다. 그 결과 황사의 발생률이 높은 봄철에 조대 입자($2.2{\mu}m$이상)의 수농도가 다른 계절보다 높게 나타났다. 기상요소 (상대습도, 풍속, 풍향, 시정 등)와 입자 수농도의 상관관계 분석에 의하면 $0.3{\sim}0.5{\mu}m$ 크기 구간에서는 상관성이 없는 것으로 나타났으며 $0.5{\sim}2.23{\mu}m$ 구간에서는 에어러솔 수농도와 상대습도가 서로 양의 상관관계를 가지는 것으로 나타났다. 풍속과의 상관성에서 작은 입자들은 풍속이 강해질수록 감소하는 패턴으로 분석되었으며 겨울철에는 조대입자 수농도가 높은 풍속에 증가하는 것으로 나타났다. 그리고 시정거리는 $0.5{\sim}1{\mu}m$ 크기 정도의 에어러솔 수 농도와 밀접한 관련이 있는 것으로 나타났으며 에어러솔 수 농도가 증가할수록 시정거리는 감소하는 경향을 보였다.