• Title/Summary/Keyword: Site Effects

Search Result 2,601, Processing Time 0.032 seconds

Relative Risk Ratio of Residents Living Near the Municipal Solid Waste Landfill Site at Some Province in South Korea

  • Lee Jin-Heon;Choi Jin-Ha
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.3
    • /
    • pp.240-248
    • /
    • 2006
  • The purposes of this study were to investigate the symptoms, diseases and deaths of residents living near the municipal solid waste landfill site, and to compare the relative risk ratio of their adverse health effects with control group. In self-evaluation, the scores were especially severe lowest in residents of v2 and v3 villages(which were located about 500 m toward under the landfill site) such as 32.2 and 16.7 for village-environment, 24.8 and 16.0 for management of landfill site, and 23.5 and 16.5 for confidence of environmental policy, respectively. On symptoms, relative risk ratios were also highest as 3.53 and 3.55 for breathing difficulty, and 3.36 and 3.00 for respiratory symptom in v2 and v3 villages, respectively. On morbidity, they were slightly high as much as 1.39 and 1.24 in v5 and v2 villages, respectively. On mortality, relative risk ratios were $1.15{\sim}2.46$ in experimental villages. They were especially high as much as 2.46 in v3 village where located near under the landfill site, and also 2.14 in v5 village where located at area affected with the landfill site, but near the sea. The rate of cancer causing death was average 35.2% of total deaths. It was very highest as much as 61.1 % in v2 village, where was closely located near under the landfill site. Cancers causing death in this village were lung cancer(3 cases), larynx cancer(2 cases), stomach cancer(2 cases), pancreatic cancer(1 case), thryoid cancer(1 case), leukemia(1 case) and other(1 case). Our data, although based on limited number of cases and geographical coverage, suggest that residents living near landfill site have the increasing relative risks of various symptoms and mortality causing cancer. No causal mechanisms are available to explain these findings. But the possibility of a causal association between the increased adverse health effects and the municipal solid waste landfill site cannot be fully excluded.

GIS-based Spatial Zonations for Regional Estimation of Site-specific Seismic Response in Seoul Metropolis (대도시 서울에서의 부지고유 지진 응답의 지역적 예측을 위한 GIS 기반의 공간 구역화)

  • Sun, Chang-Guk;Chun, Sung-Ho;Chung, Choong-Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1C
    • /
    • pp.65-76
    • /
    • 2010
  • Recent earthquake events revealed that severe seismic damages were concentrated mostly at sites composed of soil sediments rather than firm rock. This indicates that the site effects inducing the amplification of earthquake ground motion are associated mainly with the spatial distribution and dynamic properties of the soils overlying bedrock. In this study, an integrated GIS-based information system for geotechnical data was constructed to establish a regional counterplan against ground motions at a representative metropolitan area, Seoul, in Korea. To implement the GIS-based geotechnical information system for the Seoul area, existing geotechnical investigation data were collected in and around the study area and additionally a walkover site survey was carried out to acquire surface geo-knowledge data. For practical application of the geotechnical information system used to estimate the site effects at the area of interest, seismic zoning maps of geotechnical earthquake engineering parameters, such as the depth to bedrock and the site period, were created and presented as regional synthetic strategy for earthquake-induced hazards prediction. In addition, seismic zonation of site classification was also performed to determine the site amplification coefficients for seismic design at any site and administrative sub-unit in the Seoul area. Based on the case study on seismic zonations for Seoul, it was verified that the GIS-based geotechnical information system was very useful for the regional prediction of seismic hazards and also the decision support for seismic hazard mitigation particularly at the metropolitan area.

The Effect of Cd-Dopping on Sintering behavior of PNN-PT-PZ Ceramics (PNN-PZ-PT 세라믹스의 소결 거동에 미치는 Cd-doping 효과)

  • 조정호;김호기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.217-220
    • /
    • 1995
  • By substituting Cd$\^$2+/ into both A-site and B-site in PNN-PZ-PT ternary perovskite material, it is possible to determine the effects of the substitution site of Cd$\^$2+/ on sintering behavior. Sintering was performed in the temperature range from 1000$^{\circ}C$ to 1300$^{\circ}C$. The substitution site of Cd$\^$2+/ is identified by XPS spectra. Although Cd$\^$2+/ is substituted into both A-site and B-site in PNN-PZ-PT, Cd$\^$2+/ prefers A-site to B-site. The density is influenced by substitution site of Cd$\^$2+/. If Cd$\^$2+/ replaces Pv$\^$2+/, weight gain is observed during sinterig process. On the contrary, if Cd$\^$2+/ replaces Ni$\^$2+/, weight loss is promoted during sintering. From these weight changes, it is believed that Cd$\^$2+/ changes the bonding strength between B-site cation and oxygen of octahedron in perovskite structure. The changes of lattice parameters as a function of Cd$\^$2+/ content were consistent with those of the bonding strength. The densities of A-site-doped compositions were higher than those of B-site-doped composition.

  • PDF

Effects of forest fire on physical and chemical properties of soil (산불이 토양의 물리ㆍ화학적 특성에 미치는 영향)

  • 박관수
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.119-126
    • /
    • 1999
  • This study was carried out to estimate the effect of forest fire on physical and chemical properties of soil The forest fire was in April 1995 at Kongju of Chungnam. Soil samples were collected at 0~5cm, 5~10cm, and 10~20cm soil depths in September 1998 from the burned and unburned sites. Soil organic matter concentrations at 0~5cm and 5~10cm soil depths were significantly greater in unburned site than in burned site. Soil concentrations were greater in unburned site than in burned site at all soil depths. Cation exchange capacity was significantly higher in unburned site than in burned site at 0~5cm soil depth. There were no differences in available soil P, exchangeable soil K, Ca, and Mg, and pH of soil between burned and unburned sites. Soil water content at 0~5cm soil depth was significantly greater in unburned site than in burned site. Bulk density at 0~5cm soil depth was significantly higher in burned site than in unburned site. Forest fire had an adverse effect on physical and chemical properties of soil in this study, Burning of vegetation and forest 리oor organic matter in burned site may reduce organic matter supply to soil and increase soil erosion. Consequently, forest fire may have adverse influence on long-term site productivity.

  • PDF

Site Attenuations of an Open Area Test Site (야회시험장의 시험장감쇠량)

  • 김기채;정연춘;정정환;정낙삼
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.9
    • /
    • pp.1336-1343
    • /
    • 1990
  • In this paper the theoretical analysis of the site attenuation was made on the concept of mutual impedance of antennas and the cause of characteristic hump in the site attenuation curve below 80 MHz is explained. The deviation between the FCC site attenuatios and the experimental results of an ideal open area test site at low frequencies(below 80MHz) was found to be the mutual coupling effects of the antennas under the FCC's measurement conditions. It seems desirable that the site attenuations curve of FCC document be revicused to the theoretical curves presented in this paper is long as the FCC's measurement conditions are to the applied.

  • PDF

Influence of Adjacent Structures on Surface-Wave Dispersion Characteristics and 2-D Resistivity Structure (표면파 분산특성과 전기비저항 분포특성에 대한 인접구조물의 영향)

  • Joh, Sung-Ho;Kim, Bong-Chan;Cho, Mi-Ra;Kim, Suhk-Chol;Youn, Dae-Hee;Hong, Jae-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1318-1327
    • /
    • 2008
  • Geotechnical sites in urban areas may have embedded structures such as utility lines and underground concrete structures, which cause difficulties in site investigation. This study is a preliminary research to establish knowledge base for developing an optimal technique for site investigation in urban areas. Surface-wave method and resistivity survey, which are frequently adopted for non-destructive site-investigation for geotechnical sites, were investigated to characterize effects of adjacent structures. In case of surface wave method, patterns of wave propagation were investigated for typical sets of multi-layered geotechnical profiles by numerical simulation based on forward modeling theory and field experiments for small-size model tests and real-scale tests in the field. In case of resistivity survey, 3-D finite element analyses and field tests were performed to investigate effects of adjacent concrete structures. These theoretical and experimental researches for surface-wave method and resistivity survey resulted in establishing physical criteria to cause interference of adjacent structures in site investigation at urban areas.

  • PDF

The Relationship Among Service Quality, Customer Satisfaction and e-Loyalty in e-Learning Site (e-러닝 사이트에서 서비스품질 결정요인, 고객만족 및 고객 e-로열티간의 관계)

  • Kim, Yeong-Real;Han, Dae-Mun;Kim, Jong-Woo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.5
    • /
    • pp.146-162
    • /
    • 2007
  • The purpose of this study was to investigate the nature of relationship among service quality, customer satisfaction and e-loyalty in e-learning site. In order to achieve the study purpose, survey method was applied. As a result, it was revealed that service quality had significant effects on customer satisfaction in e-learning site. The influential factors of service quality on customer satisfaction included convenience of use, personalization, tangibles, responsiveness, and reliability in e-learning site. In addition, service quality had significant effects on e-loyalty as well.

  • PDF

Effects of Multi-site and Single-site Functional Massage and Stretching on Pain, Tenderness Threshold and Grip Strength in Patients with Lateral Epicondylalgia (가쪽위관절융기 통증 환자에서 복합 부위와 단일 부위에 기능적 마사지와 스트레칭을 적용할 때 통증, 압통 역치와 악력에 미치는 영향)

  • Min-keun Jung;Jae-guk Jeon;Eui-joo Shin
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.29 no.3
    • /
    • pp.13-22
    • /
    • 2023
  • Background: The purpose of this study was to investigate the effects of functional massage and stretching, applied to the elbow and shoulder joints, on pain, tenderness threshold, and grip strength. Methods: A total of 29 individuals were assigned to a single site (n=15) or multiple sites (n=14). Pain measured through the visual analogue scale (VAS), tenderness threshold (TTH), and grip strength (GI) were measured before and four weeks after the intervention. Results: After four weeks of treatment, visual analogue scale significantly decreased in both groups (p<.05), and the tenderness threshold and grip strength significantly increased in both groups (p<.05). There was also a significant difference between the two groups (p<.05). Conclusion: The reduction of visual analogue scale and the increase in the tenderness threshold and grip strength were more significant in the multi-site treatment group than in the single-site treatment group.

  • PDF

Electrical resistivity survey and interpretation considering excavation effects for the detection of loose ground in urban area

  • Seo Young Song;Bitnarae Kim;Ahyun Cho;Juyeon Jeong;Dongkweon Lee;Myung Jin Nam
    • Geomechanics and Engineering
    • /
    • v.35 no.2
    • /
    • pp.109-119
    • /
    • 2023
  • Ground subsidence in urban areas due to excessive development and degraded underground facilities is a serious problem. Geophysical surveys have been conducted to estimate the distribution and scale of cavities and subsidence. In this study, electrical resistivity tomography (ERT) was performed near an area of road subsidence in an urban area. The subsidence arose due to groundwater leakage that carried soil into a neighboring excavation site. The ERT survey line was located between the main subsidence area and an excavation site. Because ERT data are affected by rapid topographic changes and surrounding structures, the influence of the excavation site on the data was analyzed through field-scale numerical modeling. The effect of an excavation should be considered when interpreting ERT data because it can lead to wrong anomalous results. A method for performing 2D inversion after correcting resistivity data for the effect of the excavation site was proposed. This method was initially tested using a field-scale numerical model that included the excavation site and subsurface anomaly, which was a loosened zone, and was then applied to field data. In addition, ERT data were interpreted using an existing in-house 3D algorithm, which considered the effect of excavation sites. The inversion results demonstrated that conductive anomalies in the loosened zone were greater compared to the inversion that did not consider the effects of excavation.

Modeling the Effects of Low Impact Development on Runoff and Pollutant Loads from an Apartment Complex

  • Jeon, Ji-Hong;Lim, Kyoung-Jae;Choi, Dong-Hyuk;Kim, Tae-Dong
    • Environmental Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.167-172
    • /
    • 2010
  • The effects of low impact development (LID) techniques, such as green roofs and porous pavements, on the runoff and pollutant load from an apartment complex were simulated using the Site Evaluation Tool (SET). The study site was the Olympic Village, a preexisting apartment complex in Seoul, South Korea, which has a high percentage of impervious surfaces (approximately 72% of the total area). Using the SET, the effects of replacing parking lots, sidewalks and driveways (37.5% of the total area) having porous pavements and rooftops (14.5% of the total area) with green roofs were simulated. The simulation results indicated that LID techniques reduced the surface runoff, and peak flow and pollutant load, and increased the evapotranspiration and soil infiltration of precipitation. Per unit area, the green roofs were better than the porous pavements at reducing the surface runoff and pollutant loads, while the porous pavements were better than green roofs at enhancing the infiltration to soil. This study showed that LID methods can be useful for urban stormwater management and that the SET is a useful tool for evaluating the effects of LID on urban hydrology and pollutant loads from various land covers.