• 제목/요약/키워드: Sinusoidal PWM(SPWM)

검색결과 16건 처리시간 0.027초

Analysis and Implementation of Multiphase Multilevel Hybrid Single Carrier Sinusoidal Modulation

  • Govindaraju, C.;Baskaran, K.
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.365-373
    • /
    • 2010
  • This paper proposes a hybrid single carrier sinusoidal modulation suitable for multiphase multilevel inverters. Multiphase multilevel inverters are controlled by hybrid modulation to provide multiphase variable voltage and a variable frequency supply. The proposed modulation combines the benefits of fundamental frequency modulation and single carrier sinusoidal modulation (SC-SPWM) strategies. The main characteristics of hybrid modulation are a reduction in switching losses and improved harmonic performance. The proposed algorithm can be applied to cascaded multilevel inverter topologies. It has low computational complexity and it is suitable for hardware implementations. SC-SPWM and its base modulation design are implemented on a TMS320F2407 digital signal processor (DSP). A Complex Programmable Logic Device realizes the hybrid PWM algorithm and it is integrated with a DSP processor for hybrid SC-SPWM generation. The feasibility of this hybrid modulation is verified by spectral analysis, power loss analysis, simulation and experimental results.

SPWM 구동 방식을 이용한 단상 풀 브리지 인버터의 전압 제어에 대한 연구 (A Study on the Voltage Control of a Single Phase Full-bridge Inverter using SPWM Driving Method)

  • 고윤석
    • 한국전자통신학회논문지
    • /
    • 제12권5호
    • /
    • pp.851-858
    • /
    • 2017
  • 본 연구에서는 SPWM 구동방식의 단상 풀 브리지 인버터의 전압제어계를 설계하였다. 전압제어계는 단상 풀-브리지 인버터, 출력전압과 기준전압의 오차를 선형적으로 보상하기 위한 PI 제어기, 제어기 신호로부터 SPWM 방식을 이용하여 게이트 신호를 발생시키기 위한 PWM 구동회로, 인버터 출력 전압 파형을 정현 파형으로 필터링하기 위한 LC 필터로 구성하였다. 끝으로, EMTP-RV를 이용하여 PWM 구동방식을 기반으로 하는 단상 풀-브리지 인버터의 전압 제어계를 모델링하였고 수개의 기준전압에 대한 시뮬레이션 연구를 통해 출력전압이 정확하게 기준전압을 수렴하는 것을 확인함으로서 제어계 설계의 유효성을 확인할 수 있었다.

Sinewave-PWM ZVS Inverter using High-Frequency Transformer for Utility AC Voltage Link

  • Chandhaket S.;Ogura K.;Konishi Y.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.511-515
    • /
    • 2003
  • This paper presents a novel prototype of the utility-interfaced sinusoidal pulse width modulated (SPWM) inverter using the high-frequency flyback transformer fur the small-scale solar photo-voltaic power conditioner (1kW - 4kW). The proposed SPWM power conditioner circuit with a high-frequency link has a function of electrical isolation, which is vital fur solar photovoltaic power conditioner systems with the viewpoint of safety and convenience. The discontinuous conduction mode (DCM) operation of the flyback transformer is also maintained to simplify the topology of the inverter circuit and control scheme. First, the operating principle of the proposed circuit is described far the understanding of the circuit parameters establishment. Then, the digitally constructed SPWM control scheme is presented. The proposed circuit is verified by the computer simulation and the prototype experiment.

  • PDF

A Single-Input Single-Output Approach by using Minor-Loop Voltage Feedback Compensation with Modified SPWM Technique for Three-Phase AC-DC Buck Converter

  • Alias, Azrita;Rahim, Nasrudin Abd.;Hussain, Mohamed Azlan
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.829-840
    • /
    • 2013
  • The modified sinusoidal pulse-width modulation (SPWM) is one of the PWM techniques used in three-phase AC-DC buck converters. The modified SPWM works without the current sensor (the converter is current sensorless), improves production of sinusoidal AC current, enables obtainment of near-unity power factor, and controls output voltage through modulation gain (ranging from 0 to 1). The main problem of the modified SPWM is the huge starting current and voltage (during transient) that results from a large step change from the reference voltage. When the load changes, the output voltage significantly drops (through switching losses and non-ideal converter elements). The single-input single-output (SISO) approach with minor-loop voltage feedback controller presented here overcomes this problem. This approach is created on a theoretical linear model and verified by discrete-model simulation on MATLAB/Simulink. The capability and effectiveness of the SISO approach in compensating start-up current/voltage and in achieving zero steady-state error were tested for transient cases with step-changed load and step-changed reference voltage for linear and non-linear loads. Tests were done to analyze the transient performance against various controller gains. An experiment prototype was also developed for verification.

견인전동기 구동시스템의 소음 저감을 위한 MRSF-PWM 방식 (MRSF-PWM Method for Acoustic Noise Reduction of Traction Motor Drive Systems)

  • 홍순찬;서영민
    • 전력전자학회논문지
    • /
    • 제7권3호
    • /
    • pp.262-271
    • /
    • 2002
  • 견인전동기 구동시스템에 사용되는 PWM 인버터는 전력용량이 크기 때문에 스위칭주파수가 제한되며, 따라서 전자기적 가청소음이 발생한다. 이러한 가청소음을 줄이기 위하여 새로운 MRSF-PWM 방식을 제안한다. 제안한 MRSF-PWM 방식에서는 고조파를 확산시키기 위해 삼각파와 톱니파를 함께 운송파로 사용하며, 출력전압의 선형제어범위를 넓히기 위해 정현파에 3차 고조파를 주입한 파형을 기준파로 사용한다. MRSF-PWM 방식의 타당성을 검증하기 위하여 컴퓨터 시뮬레이션을 수행하였다. 그 결과, MRSF-PWM 방식이 선형성 및 고조파 확산면에서 다른 RPWM 방식보다 우수하며 가청소음 저감면에서 SPWM 방식보다 효과적임을 확인하였다.

3레벨 4레그 PWM 컨버터의 커먼 모드 전압 저감 (Common-mode Voltage Reduction of Three Level Four Leg PWM Converter)

  • 지승준;고상기;김현식;설승기
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.488-493
    • /
    • 2014
  • This paper presents a carrier-based pulse-width modulation(PWM) method for reducing the common-mode voltage of a three-level four-leg converter. The idea of the proposed PWM method is intuitive and easy to be implemented in digital signal processor-based converter control systems. On the basis of the analysis of space-vector PWM(SVPWM) and sinusoidal PWM(SPWM) switching patterns, the fourth leg pole voltage of the three-phase converter called "f leg pole voltage" is manipulated to reduce the common-mode voltage. To synthesize f leg pole voltage for the suppression of the common-mode voltage, positive and negative pole voltage references of f leg are calculated. An offset voltage is also deduced to prevent the distortion of a, b, and c phase voltages. The feasibility of the proposed PWM method is verified by simulation and experimental results. The common-mode voltage of the proposed PWM method in peak-to-peak value is 33% in comparison with that of the conventional SVPWM method. The transition number of the common-mode voltage is also reduced to 25%.

Wavelet PWM Technique for Single-Phase Three-Level Inverters

  • Zheng, Chun-Fang;Zhang, Bo;Qiu, Dong-Yuan;Zhang, Xiao-Hui;Xiao, Le-Ming
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1517-1523
    • /
    • 2015
  • The wavelet PWM (WPWM) technique has been applied in two-level inverters successfully, but directly applying the WPWM technique to three-level inverters is impossible. This paper proposes a WPWM technique suitable for a single-phase three-level inverter. The work analyzes the control strategy with the WPWM and obtains the design of its parameters. Compared with the SPWM technique for a single-phase three-level inverter under the same conditions, the WPWM can obtain high magnitudes of the output fundamental frequency component, low total harmonic distortion, and simpler digital implementation. The feasibility experiment is given to verify of the proposed WPWM technique.

A Ripple Rejection Inherited RPWM for VSI Working with Fluctuating DC Link Voltage

  • Jarin, T.;Subburaj, P.;Bright, Shibu J V
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2018-2030
    • /
    • 2015
  • A two stage ac drive configuration consisting of a single-phase line commutated rectifier and a three-phase voltage source inverter (VSI) is very common in low and medium power applications. The deterministic pulse width modulation (PWM) methods like sinusoidal PWM (SPWM) could not be considered as an ideal choice for modern drives since they result mechanical vibration and acoustic noise, and limit the application scope. This is due to the incapability of the deterministic PWM strategies in sprawling the harmonic power. The random PWM (RPWM) approaches could solve this issue by creating continuous harmonic profile instead of discrete clusters of dominant harmonics. Insufficient filtering at dc link results in the amplitude distortion of the input dc voltage to the VSI and has the most significant impact on the spectral errors (difference between theoretical and practical spectra). It is obvious that the sprawling effect of RPWM undoubtedly influenced by input fluctuation and the discrete harmonic clusters may reappear. The influence of dc link fluctuation on harmonics and their spreading effect in the VSI remains invalidated. A case study is done with four different filter capacitor values in this paper and results are compared with the constant dc input operation. This paper also proposes an ingenious RPWM, a ripple dosed sinusoidal reference-random carrier PWM (RDSRRCPWM), which has the innate capacity of suppressing the effect of input fluctuation in the output than the other modern PWM methods. MATLAB based simulation study reveals the fundamental component, total harmonic distortion (THD) and harmonic spread factor (HSF) for various modulation indices. The non-ideal dc link is managed well with the developed RDSRRCPWM applied to the VSI and tested in a proto type VSI using the field programmable gate array (FPGA).

Cascaded NPC/H-bridge 컨버터의 DC링크 리플 저감을 위한 3차 고조파 주입 기법 (DC-link Ripple Reduction of Cascaded NPC/H-bridge Converter using Third Harmonic Injection)

  • 박우호;강진욱;현승욱;홍석진;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.218-219
    • /
    • 2016
  • This paper present Phase Shifted with carrier based on Sinusoidal PWM(SPWM) by using Cascaded NPC/H-birdge converter. The proposed Phase Shifted PWM method is adding third harmonic injection in switching signal. The advantage of the proposed method is reducing the voltage and capacity of the capacitor. This paper compare general Phase Shifted method with proposed Phase Shifted method that added the third harmonic injection. Each PWM method is tested without considering the switching loss by using PSIM 9.1.4 simulation.

  • PDF

연료 전지 시스템을 위한 Z-소스 인버터고 구성된 병렬 운전 시스템 (Parallel Operation Systems of Z-Source Inverters for Fuel Cell Systems)

  • 문현욱;정은진;김윤호
    • 전력전자학회논문지
    • /
    • 제10권5호
    • /
    • pp.443-449
    • /
    • 2005
  • 본 논문에서는 연료 전지 시스템을 위한 Z-소스 인버터로 구성된 병렬 운전 시스템을 제시 하였다. PWM 방식으로는 Carrier phase shifted SPWM을 적용하였으며 이 방식은 출력 전류의 고조파 성분을 줄일 수 있는 장점을 갖는다. 그러나 이 기법을 Z-소스 인버터로 구성된 병렬 운전 시스템에 적용하는 경우 추가적으로 순환 전류를 발생한다. Z-소스 인버터로 구성된 병렬 운전 시스템이 동작 시 발생하는 순환 전류를 분석하고 순환 전류를 감소시키며, 부하전류에 낮은 고조파 성분을 가질 수 있도록 순환 전류 리액터를 사용하였다. 이에 대한 적합성을 시뮬레이션과 실험을 통해 입증하였다.