• Title/Summary/Keyword: Sinusoidal

Search Result 1,980, Processing Time 0.031 seconds

Estimation of Lateral Dynamic P-multiplier of Group Pile Using Dynamic Numerical Analysis Results (동적 수치해석 결과를 이용한 군말뚝의 횡방향 동적 P-승수 산정)

  • Park, Jeong-Sik;Jeong, Sang-Seom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.567-578
    • /
    • 2018
  • In this study, to investigate the effect of the stress reduction of group piles by dynamic loading, a dynamic p-y curve was established and the dynamic p-multiplier was calculated. Dynamic numerical analysis was performed by input sinusoidal waves to the bottom of the pile - ground system for $2{\times}2$ group pile, single pile and $5{\times}5$ group pile, single pile in dry sandy soil, and the pile spacing was changed to 2.5 and 5.0 times of the pile diameter. By establishing and comparing the dynamic p-y curves of the single pile and group piles, the dynamic group pile effect of the piles according to the pile center spacing and row position of the group pile piles is analyzed. $5{\times}5$ showed symmetry of the dynamic P-multiplier value around the pile origin coordinate. The dynamic p-multiplier value at the single pile, $5{\times}5$ pile (pile spacing: 2.5D) is 0.26 ~ 0.30 at the pile number 3, pile number 23, 0.14 pile number 13, and 0.14 ~ 0.38 at the pile number 5, pile number 18. These values differed from the static p-multiplier, especially due to the different loading conditions. The dynamic p-multiplier ($P_{dm}$) estimation through various types of input dynamic loads is expected to be used for dynamic design and analysis of group pile-ground systems of civil foundation structures.

Evaluation of Dynamic Group Pile Effect in Dry Sand by Centrifuge Model Tests (원심모형 실험을 이용한 건조토 지반에서의 군말뚝 효과 분석)

  • Yoo, Min-Taek;Cha, Se-Hwan;Choi, Jung-In;Han, Jin-Tae;Kim, Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.1
    • /
    • pp.67-77
    • /
    • 2012
  • In this study, a series of centrifuge shaking-table tests for a $3{\times}3$ group pile and a single pile applied by sinusoidal wave was performed in dry sand for various pile spacings, ranging from three to seven times the pile diameter. A comparison of centrifuge tests of both single pile and group pile showed that the lateral ground response of the group pile was smaller than that of the single pile. In addition, the reduction in subgrade reaction for the group pile increased with decreasing pile spacing. The side piles, that is, the 1st row and 3rd row piles showed identical dynamic p-y behavior and the center pile in the 2nd row caused a lower reduction effect compared with the 1st and 3rd row piles. From the comparison between the p-y curves of the 2nd row piles, it was found that the lateral ground response of the outer pile in the 2nd row was less than that of the center pile in the 2nd row. The p-multipliers for the side piles, for the center pile and for the outer pile ranged from 0.28 to 0.77, from 0.55 to 1.0 and from 0.39 to 0.87, respectively.

Development of Fiber Optic Total Reflected Extrinsic Fabry-Perot Interferometric Sensor for Structural Strain Measurement (구조물의 변형률 측정을 위한 광섬유 TR-EFPI 센서의 개발)

  • Kwon, In-Bum;Choi, Man-Yong;Moon, Hahn-Gue;Kim, Min-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.96-105
    • /
    • 2000
  • Fiber optic TR-EFPI(total reflected extrtinsic Fabry-Perot interferometric) sensor was developed to measure the strain of structures, such as building, bridge, aircraft, etc. It has been difficult to distinguish the increase and decrease of the strain from the conventional fiber optic EFPI sensor because their signals only have a sinusoidal wave pattern related to the change of strain. Also, the absolute strain could not be measured by the simple fiber optic EFPI sensor. In this study, in order to measure the magnitude of strain with the direction of strain, the fiber optic sensor was simply constructed with the total reflected EFPI sensor probe. This probe was manufactured with a single mode fiber and a mirror coated fiber in a silica glass capillary tube. The output signal of this fiber optic TR-EFPT sensor can give the information about the magnitude and the direction of strain. The loading-unloading test was performed by the universal testing machine with alluminum beam specimen to compare the strain from fiber optic TR-EFPI sensor with the value from electrical strain gauge. In the result of this experiment. the strain from fiber optic TR-EFPI sensor had a good agreement with the values from the electrical strain gauge.

  • PDF

Effects of Crataegii fructus on the Contractile Response of Rabbit Corpus Cavernosum (산사(山査)가 토끼 음경해면체의 수축에 미치는 영향)

  • Lee, Han Seok;Park, Sun Young
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.5
    • /
    • pp.602-610
    • /
    • 2013
  • This study was aimed to evaluate the cavernosal relaxation effect of Crataegii fructus(CF) in the contracted rabbit penile corpus cavernosum by agonists.In order to study the effect of CF on the vasoconstriction of rabbit penile corpus cavernosum, isolated rabbit penile corpus cavernosum tissues were used for the experiment using organ baths containing Krebs solution.To investigate the cavernosal relaxation of CF, CF extract at $0.01{\sim}3.0mg/m{\ell}$ was added after penile corpus cavernosum were contracted by norepinephrine(NE) $1{\mu}M$. To analyze the mechanism of CF's vasorelaxation, CF extract infused into contracted penile tissues by NE after each treatment of indomethacin(IM), $N{\omega}$-nitro-L-arginine(L-NNA), methylene blue(MB), tetraethylammonium chloride(TEA).To study the effect of CF on influx of extracellular calcium chloride($Ca^{2+}$) in penile tissues, in $Ca^{2+}$-free krebs solution, $Ca^{2+}$ 1 mM infused into contracted penile tissues by NE after pretreatment of CF. Cytotoxic activity of CF on human umbilical vein endothelial cell(HUVEC) was measured by MTT assay, and nitric oxide(NO) prodution was measured by Griess reagent. CF relaxed cavernosal strip with endothelium contracted by NE, but in the strips without endothelium, CF-induced relaxation was significantly inhibited. The pretreatment of L-NNA, MB, TEA decreased significantly on the cavernosal relaxation than not-treatment of them. But the pretreatment of IM had no significant effect on the cavernosal relaxation. In $Ca^{2+}$-free krebs solution, when $Ca^{2+}$ infused into contracted penile tissues by NE, pretreatment of CF inhibit contraction induced by adding $Ca^{2+}$.NO production wasn't increased by treatment of CF on HUVEC. This findings showed that CF is effective for the relaxation of rabbit penile corpus cavernosum, and we suggest that CF relax rabbit corpus cavernosal smooth muscle through multiple action mechanisms that include increasing the release of nitric oxide from corporal sinusoidal endothelium, inhibition of $Ca^{2+}$ mobilization into cytosol from the extracellular fluid, and maybe a hyperpolarizing action.

A Study on the Torque Characteristics Depending on the Elastic Body Materials of a Hexadecagon Shaped Ultrasonic Motor (탄성체 재질 변화에 따른 16각형 초음파모터의 토크 특성 연구)

  • Cheon, Seong-Kyu;Jeong, Seong-Su;Lee, Byung-Ha;Ha, Yong-Woo;Kim, Myong-Ho;Park, Tae-Gone
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.5
    • /
    • pp.286-291
    • /
    • 2014
  • In this study, novel ultrasonic rotary motor of hexadecagon shape stator was proposed. Stator of the hexadecagon ultrasonic motor was composed of an elastic ring and ceramics. The elastic ring had sixteen sides and sixteen angular points. Eight ceramics were attached on the outer surface of the eight sides of the ring. When rotor of cylindrical shaft was inserted inside of the ring stator, central lines of the sixteen sides of the stator hold the shaft by the slight pressures(frictions). This slight pressure was a preload of the motor and it could be controlled by radius and thickness of the ring. When two sinusoidal voltages which have 90 degree phase difference were applied to each four ceramics, elliptical displacements of inner surface of the ring were obtained. These elliptical displacements of the inner surface rotated the shaft rotor through the frictions. The proposed hexadecagon ultrasonic motor was designed and analyzed by using the finite element method (FEM), depending on materials of the elastic ring. Based on the FEM results, one model of motor which showed maximum displacement at contact points was chosen and fabricated. And characteristics of the motor were compared with simulated results. When the motor was fabricated with these results, EL20ET0.5CT0.5CW2 model showed 115[rpm] speed about input voltage of 60[Vrms] at 65.6[kHz]. And the maximum torque of 6[gfcm] was obtained. From these results, the hexadecagon shaped ultrasonic motor can be used to actuator for optical device which needs detailed position control. Also it can be used to medical and portable device by reducing size and weight.

Experimental Study on Steel Beam with Embossment Web (엠보싱 웨브를 가지는 보 부재의 실험적 연구)

  • Park, Han-Min;Lee, Hee-Du;Shin, Kyung-Jae;Lee, Swoo-Heon;Chae, Il Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.479-486
    • /
    • 2017
  • Steel beams with corrugated web have been widely used in the steel structures. However, it is challenging to weld the section between the corrugated web and the flange straight, which increases the cost of production. In order to solve this issue, steel beam with intaglio and embossed web (It is called an IEB) was invented. A web with embossment is produced by cold pressing and welded to flange by automatic welding machine. The loading tests were conducted to investigate the load-carrying capacity of IEB, and its test result was compared with that of H-shaped beam having a same size of flange and web. The test results of IEB series showed about 40% higher load capacities than H-shaped series. As a result of comparing the IEB specimen with Eurocodes for steel beams with corrugated web, all of specimens tested in this study did not meet the design value. Therefore, it is difficult to apply existing formula to IEB and new design formula should be presented for field application.

Amplification and Howling Suppression of Telephonic Speech for the Hearing-Impaired Person (난청인을 위한 전화기 음성증폭 및 하울링 억제)

  • Lee, Sang-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.6
    • /
    • pp.623-629
    • /
    • 1998
  • To provide sufficient sound to the hearing-impaired person(HIP) who have many difficulty in communication with others using general telephone, big amplification is needed. But big amplification can occur howling as a side effect. In this study we developed the new technique of big amplification without howling, manufactured and estimated the new hearing aid telephone. Telephone speech is divided to three frequency band, amplified respectively and fitted to HIP's hearing ability. The telephone speech frequency is monitored by counter in time domain. The counter transfers the sinusoidal sound to rectangular wave using comparator and counts the number of rectangular wave in a certain time period, that is frequency, to monitor the howling. Telephone have microphone and speaker, which are fitted in a rigid structure and frequency band of telephone sound is limited, so howling occurs in the limited frequency band. If the counter notices that howling conditions happen, microprocessor decreases quickly the gain of the related frequency band. The result of test of our new hearing aid telephone showed that we can amplifiy the sound as much as 40dB, which is meaningful level to many HIP, and make HIP increase their perception ability from 20% to 60.8% in 1 syllable test and from 28.9% to 78% in 2 syllable test.

  • PDF

Development of a Frequency Dependent Type Apex Locator with Automatic Compensation (자동 보정 주파수 의존형 근관장 측정기의 개발)

  • Kim, Deok-Won;Nam, Gi-Chang;Kim, Yeong-Ju;Lee, Seung-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.6
    • /
    • pp.595-602
    • /
    • 1998
  • Among the apex locators, the frequency dependent type is more accurate and convenient to use than others, But the accuracy of the apex locator is still influenced by the presence of various electrolytes used in root canal treatments. In this study, we have developed a frequency dependent electronic apex locator minimizing the influence of the electrolytes on the measurement of root canal lengths. It was also confirmed that two frequencies of 500Hz and 100kHz are optimal for the measuring impedance compare with commercial product used(400Hz and 8kHz)a and there were no differences in accuracy among the three different types of the waveforms; sinusoidal, triangular, and rectangular waves(p>0.05). Impedance ratio of the two different frequencies represents the position of the file in root canal, and the voltage difference of two signals represents the status of the fluid in the root canal. As a result of compensation using the voltage differences, the errors were decreased on the average from +0.54mm to +0.18mm in $H_2O_2$ solution (p<0.01), and from -0.33mm to -0.01mm in NaOCl solution(p<0.01). The accuracies based on ${\pm}$0.5mm, in $H_2O_2$ and NaOCl solutions were improved with the automatic compensation from 71.1% and 91.1% to 82.2% and 100% respectively.

  • PDF

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

Electrical Stimulation Can Facilitate Vestibular Compensation Following Unilateral Labyrinthectomy in Rats

  • Park, Byung-Rim;Kim, Jin-Ok;Kim, Min-Sun;Lee, Moon-Young;Kim, Jae-Hyo;Jin, Yuan-Zhe;Choi, Myung-Ae
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.5 no.2
    • /
    • pp.123-131
    • /
    • 2001
  • To investigate the effects of electrical stimulation on vestibular compensation, which is the recovery of vestibular symptoms following unilateral labyrinthectomy (UL), intermittent electrical stimulation was applied to the injured vestibular portion in Sprague-Dawley rats. Vestibuloocular and vestibulospinal reflexes, electrical activity and expression of c-Fos protein in medial vestibular nuclei (MVN) were measured with time following UL. Spontaneous nystagmus occurred with frequency of $2.9{\pm}0.2$ beats/sec at 2 hours after UL and disappeared after 72 hours. Electrical stimulation decreased the frequency of nystagmus significantly till 24 hours after UL. Roll head deviation was $107{\pm}9.7^{\circ}$ at 2 hours after UL and the deviation was maintained till 72 hours, but electrical stimulation decreased the deviation significantly 6 hours after UL. Resting activity of type I neurons in ipsilateral MVN to the injured vestibular side decreased significantly compared with control at 6 and 24 hours after UL, but the activity of type I neurons was recovered to control level by electrical stimulation at 24 hours after UL. Gain of type I neurons induced by sinusoidal rotation of 0.1 Hz decreased significantly till 24 hours after UL, but electrical stimulation restored the activity at 24 hours. The gain of type II neurons decreased significantly at 6 hours after UL, but electrical stimulation restored the activity. Expression of c-Fos protein was asymmetric between bilateral MVN till 24 hours after UL, but the asymmetry disappeared by electrical stimulation 6 hours after UL. These results suggest that electrical stimulation to the injured vestibular portion facilitates vestibular compensation following UL by restoration of symmetry of neuronal activity between bilateral vestibular nuclei resulting from increased activity in ipsilateral vestibular nuclei to the injured side.

  • PDF