• Title/Summary/Keyword: Sink Unit

Search Result 60, Processing Time 0.026 seconds

Analysis of Carbonation Reduction Coefficient and CO2 uptakes under Finishing Materials (표면마감 조건에 따른 탄산화감소계수 및 CO2 흡수량 산정)

  • Song, Hun;Shin, Hyeon-UK;Chu, Yong-Sik;Lee, Jong-Kyu;Cho, Hyung-Kyu;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.215-216
    • /
    • 2012
  • Emissions of CO2 occur during the production of cement manufacturing process. During the production of clinker, limestone is mainly calcium carbonate, is heated to produce lime and CO2 as a by-product. It has a major problem, CO2 uptake is not considered in concrete carbonation, just focus in CO2 emission. This study is to develop a simulation model for CO2 uptakes in concrete structures based on carbonation reduction coefficient considering finishing materials. CO2 uptakes unit of concrete cubic meter is calculated by CO2 emissions unit of concrete materials and usage of concrete materials in mix proportion. From the simulation result, CO2 uptake ratios is 2.04 percent in carbonation models of concrete structure during 40 years.

  • PDF

A Numerical Study on a Prediction of Performance of the Metal Hydride Thermal Conversion System through the Propagation Phenomena of Superadiabatic Thermal Waves (초단열 열파동의 전파현상을 활용하는 수소저장합금 열변환 시스템의 성능예측을 위한 수치해석적 연구)

  • Kim, Gyu-Jeong;Kim, Gwan-Yeong;Chae, Jae-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.572-582
    • /
    • 2001
  • A method of metal-hydride thermal conversion that is an alternative to the traditional method is proposed and investigated. The unit heat pump consists of reactors of two different metal-hydrides are distributed inside parallel channels filled with porous media. The channels are blown through with a heat-transfer agent. Thermal conversion develops as a set of successive heat waves. By a numerical-modeling method it is shown that the maximum thermal effect is attained in synchronous motion of the heat wave and the heat source (or sink) that accompanies the phase transition in the succession of unit metal-hydride pumps. The results are presented in a form convenient for prediction of the thermal and energy efficiency of the proposed thermal-conversion method in real devices.

Living Space Needs of Rural Elderly Residents in a Farming Retirement Community (자영농 노인촌락 입주자의 생활공간 욕구)

  • 이인수
    • Korean Institute of Interior Design Journal
    • /
    • no.14
    • /
    • pp.42-54
    • /
    • 1998
  • This study aims to analyze needs for living space of residents in a farming retirement community In this study a survey was performed about desire for living space and aesthetic aspects of housing environment. Results of the study are as follows; 1. Most residents desire permanently formed dwelling unit rather than assembled temporary structure so that they comfortable in noise-prevented space. 2 The retirement community residents do not desperately prefer individually separated room because open space provides better observsation function for emergencies. 3. They hope their dwelling units are grouped like regular neighborhood and the units have traditional designs such conventional kitchen and sink and wooden floor. Finally in this study it is proposed that Korean rural retirement community be established with maximum use conventional dwelling resources so that the residents benefit old fashioned living tradition even in the recently moved retirement society.

  • PDF

Forced Convective Cooling Characteristics with Stacked Modules of Multi-PCBs' in Telecommunication Cabinet (다중 PCB 적층 모듈구조의 정보통신용 캐비넷 강제대류 냉각특성 연구)

  • Kim, W.T.;Kim, K.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.230-239
    • /
    • 1996
  • A multi-faceted experimental investigation has been carried out to study the cooling performance for stacked modules in arrays of heat generating rectangular modules deployed along PCB's in the enclosed cabinet. The main parameters which have an important effect on cooling characteristics are flow velocity, channel spacing, installation of fan unit, attachment of heat sink, and acoustic noise. The results of individual effect are very helpful for the electronic packaging designer. In order to improve the cooling performance, it is certain that the enlargement of channel space is obviously effective, while this id disadvantageous in high density electronic packaging. Each of the paameters is quantitatively examined as cooling performance and the correlation of Reynolds number to Nusselt number is compared with previous study.

  • PDF

Evaluation on Thermal Potential of Tap Water, Rain Water, Waste Water as City Water System (도시 수자원으로서의 상수.우수, 하수에 대한 열적 포텐셜의 평가)

  • ;大阪大學
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.26-33
    • /
    • 1998
  • It has been referred as a problem that heat source/sink is distance from heat demand area in using unused energy. To solve the distance problem in using unused energy, the water from city water system like tap water, rain water, waste water used as unused energy. To survey the potential of the water of city water system, it is developed that the calculation method of the potential using unit method. The amount of theoretical unused energy and energy saving in the Osaka City, Japan were estimated by using that method.

  • PDF

Second Law Optimization of Water-to-Water Heat Pump System

  • Kim, Kyu-Hyung;Woo, Joung-Son;Lee, Se-Kyoun
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.122-128
    • /
    • 2003
  • This paper presents a thermodynamic analysis of heat pump system using water as a heat source and heat sink. The primary object in this study is the optimization of exergetic efficiency. Two different systems, 2-stream and 1-stream system, are analyzed in detail. Mass flow ratio (the ratio of mass flow rate of water through evaporator to that through condenser) is identified as the most important parameter to be optimized. It is shown that there exists an optimum mass flow ratio to maximize exergetic efficiency. The variation of optimum exergetic efficiency of 2-stream system is quite small and the value lies between 0.2∼0.23 for the range of investigation in this study. However, far better performance can be obtained from 1-stream system. This means considerable irreversibilities are generated through condenser of the 2-stream system. The effects of adiabatic efficiency of compressor-motor unit on the overall system performance are also examined in the analysis.

Thermodynamic Analysis of Power Generation Cycle Utilizing LNG Cold Energy (LNG 냉열을 이용하는 동력사이클 열역학 해석)

  • 최권일;장홍일
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.1
    • /
    • pp.48-55
    • /
    • 1999
  • thermodynamic cycle analysis has been performed for the power generation systems to utilize the cold energy of liquefied natural gas (LNG). The power cycle used the air or water at room temperature as a heat source and the LNG at cryogenic temperature as a heat sink. Among manypossible configurations of the cycle. the open Rankine cycle. and the closed Brayton cycle, and the closed Rankine cycle are selected for the basic analysis because of their practical importance. The power output per unit mass of LNG has been analytically calculated for various design parameters such as the pressure ratio. the mass flow rate. the adiabatic efficiency. the heat exchanger effectiveness. or the working fluid. The optimal conditions for the parameters are presented to maximize the power output and the design considerations are discussed. It is concluded that the open Rankine cycle is the most recormmendable both in thermodynamic efficency and in practice.

  • PDF

The dweller's consciousness, satisfaction and demands on bathroom in 30s pyung apartments (아파트 거주자의 욕실에 대한 의식.만족.요수 -30평형대 아파트를 중심으로-)

  • 이영심;신경주
    • Journal of the Korean housing association
    • /
    • v.9 no.1
    • /
    • pp.43-53
    • /
    • 1998
  • The purpose of this study is to provide a basic study for a desirable bathroom planning of the 30s pyung apartment. The survey was performed to the housewives of 30s pyung apartments in Seoul. The purpose of the survey was to examine the dweller's consciousness, satisfaction, and demands on bathroom in 30s pyung apartments, and to give useful information on bathroom planning of 30s pyung apartment. Some details shoul be considered in bathroom planning of 30s pyung spartments. It seems that the bathrooms of bath unit and extra sink and a toilet stool are the most approriate type in 30s pyung apartment among present bathroom types. It is suitable that the bathroom is close to bedroom and the bathroom door faces the wall. There is much meed for a showercurtain and more comfortable toilet stool. It is necessary to reduce the noise of toilet stool and reinforce the soundproofing fuction in bathroom. And the function of ventilation, drainage, and insulation should be improved for better bathroom enivronment. The implications of this findings for apartment bathroom planning and future research were discussed.

  • PDF

LED Module Temperature Analysis for LED Chip Thermal Resistance Measurement (LED Chip 열저항측정을 통한 LED Module 온도분석)

  • Jeong, Hee-Suk;Yoo, Hyoung-Yul;Kim, Jeong-Su;Lee, Young-Joo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.164-167
    • /
    • 2009
  • It is difficult to measure junction temperature in the LED Module. According to the arrangement control unit and heat sink, temperature distribution is changed in the LED Module. A method of forecasting LED Module thermal resistance is suggested with measuring LED and PCB board temperature.

  • PDF

A Structured and Multi-cellular Model of Starch Biosynthesis in Potato

  • Saithong, Treenut;Saraboon, Piyaporn;Meechai, Asawin;Cheevadhanarak, Supapon;Bhumiratana, Sakarindr
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2005.09a
    • /
    • pp.151-155
    • /
    • 2005
  • Recently, systems biology has been increasingly applied to gain insights into the complexity of living organisms. Many inaccessible biological information and hidden evidences fur example flux distribution of the metabolites are simply revealed by investigation of artificial cell behaviors. Most bio-models are models of single cell organisms that cannot handle the multi-cellular organisms like plants. Herein, a structured and multi-cellular model of potato was developed to comprehend the root starch biosynthesis. On the basis of simplest plant cell biology, a potato structured model on the platform of Berkley Madonna was divided into three parts: photosynthetic (leaf), non-photosynthetic (tuber) and transportation (phloem) cells. The model of starch biosynthesis begins with the fixation of CO$_2$ from atmosphere to the Calvin cycle. Passing through a series of reactions, triose phosphate from Calvin cycle is converted to sucrose which is transported to sink cells and is eventually formed the amylose and amylopectin (starch constituents). After validating the model with data from a number of literatures, the results show that the structured model is a good representative of the studied system. The result of triose phosphate (DHAP and GAP) elevation due to lessening the aldolase activity is an illustration of the validation. Furthermore, the representative model was used to gain more understanding of starch production process such as the effect of CO$_2$ uptake on qualitative and quantitative aspects of starch biosynthesis.

  • PDF