• 제목/요약/키워드: Single-switching state

검색결과 111건 처리시간 0.022초

Analysis and Implementation of a New Single Switch, High Voltage Gain DC-DC Converter with a Wide CCM Operation Range and Reduced Components Voltage Stress

  • Honarjoo, Babak;Madani, Seyed M.;Niroomand, Mehdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.11-22
    • /
    • 2018
  • This paper presents a single switch, high step-up, non-isolated dc-dc converter suitable for renewable energy applications. The proposed converter is composed of a coupled inductor, a passive clamp circuit, a switched capacitor and voltage lift circuits. The passive clamp recovers the leakage inductance energy of the coupled inductor and limits the voltage spike on the switch. The configuration of the passive clamp and switched capacitor circuit increases the voltage gain. A wide continuous conduction mode (CCM) operation range, a low turn ratio for the coupled inductor, low voltage stress on the switch, switch turn on under almost zero current switching (ZCS), low voltage stress on the diodes, leakage inductance energy recovery, high efficiency and a high voltage gain without a large duty cycle are the benefits of this converter. The steady state operation of the converter in the continuous conduction mode (CCM) and discontinuous conduction mode (DCM) is discussed and analyzed. A 200W prototype converter with a 28V input and a 380V output voltage is implemented and tested to verify the theoretical analysis.

Simple Technique Reducing Leakage Current for H-Bridge Converter in Transformerless Photovoltaic Generation

  • Kot, Radoslaw;Stynski, Sebastian;Stepien, Krzysztof;Zaleski, Jaroslaw;Malinowski, Mariusz
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.153-162
    • /
    • 2016
  • Given their structural arrangement, photovoltaic (PV) modules exhibit parasitic capacitance, which creates a path for high-frequency current during zero-state switching of the converter in transformerless systems. This current has to be limited to ensure safety and electromagnetic compatibility. Many solutions that can minimize or completely avoid this phenomenon, are available. However, most of these solutions are patented because they rely on specific and often complex converter topologies. This study aims to solve this problem by introducing a solution based on a classic converter topology with an appropriate modulation technique and passive filtering. A 5.5 kW single-phase residential PV system that consists of DC-DC boost stage and DC-AC H-bridge converter is considered. Control schemes for both converter stages are presented. An overview of existing modulation techniques for H-bridge converter is provided, and a modification of hybrid modulation is proposed. A system prototype is built for the experimental verification. As shown in the study, with simple filtering and proper selection of switching states, achieving low leakage current level is possible while maintaining high converter efficiency and required energy quality.

단상 강압 정류기를 이용한 유도전동기의 효율 및 역률 개선 (Efficiency and Power Factor Improvement of Induction Motor Using Single-Phase Back Rectifier)

  • 문상필;이현우;서기영
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.22-29
    • /
    • 2002
  • 일반적으로 유도 전동기 가변속 운전할 때 인버터의 스위칭 작용으로 많은 고조파가 포함되어 전동기의 고조파 손실, 토크 맥동, 전자기적 소음 및 진동 등을 초래하게 된다. 이와 같은 문제점을 해결하기 위하여 본 논문에서는 부분공진 벅 컨버터와 3상 전압형 SPWM 인버터 회로를 유도전동기 운전시스템에 적용하였다. 제안한 회로의 입력전류를 거의 단위 역률로 정현파화하기 위해 동작 조건을 다양하게 변화시켰으며 커패시터는 보조다이오드와 전력스위칭에 적절히 배열하여 전원측으로 전압을 회생시켜 공급하였다. 그리고 전압반전기능을 부가하는 것에 의해 전원전압 극성 반전시 입력전류의 변형 최소화함으로서 역률 및 효율이 개선시켰다. 또한 출력 필터를 이용하여 출력선간전압의 고조파 성분을 감소하였으며, 상태공간 해석을 도입하여 정류기의 동작을 예측하였다. 이러한 모든 사항은 시뮬레이션과 실험을 통하여 그 타당성을 확인하였다.

A Physical-layer Security Scheme Based on Cross-layer Cooperation in Dense Heterogeneous Networks

  • Zhang, Bo;Huang, Kai-zhi;Chen, Ya-jun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제12권6호
    • /
    • pp.2595-2618
    • /
    • 2018
  • In this paper, we investigate secure communication with the presence of multiple eavesdroppers (Eves) in a two-tier downlink dense heterogeneous network, wherein there is a macrocell base station (MBS) and multiple femtocell base stations (FBSs). Each base station (BS) has multiple users. And Eves attempt to wiretap a macrocell user (MU). To keep Eves ignorant of the confidential message, we propose a physical-layer security scheme based on cross-layer cooperation to exploit interference in the considered network. Under the constraints on the quality of service (QoS) of other legitimate users and transmit power, the secrecy rate of system can be maximized through jointly optimizing the beamforming vectors of MBS and cooperative FBSs. We explore the problem of maximizing secrecy rate in both non-colluding and colluding Eves scenarios, respectively. Firstly, in non-colluding Eves scenario, we approximate the original non-convex problem into a few semi-definite programs (SDPs) by employing the semi-definite relaxation (SDR) technique and conservative convex approximation under perfect channel state information (CSI) case. Furthermore, we extend the frame to imperfect CSI case and use the Lagrangian dual theory to cope with uncertain constraints on CSI. Secondly, in colluding Eves scenario, we transform the original problem into a two-tier optimization problem equivalently. Among them, the outer layer problem is a single variable optimization problem and can be solved by one-dimensional linear search. While the inner-layer optimization problem is transformed into a convex SDP problem with SDR technique and Charnes-Cooper transformation. In the perfect CSI case of both non-colluding and colluding Eves scenarios, we prove that the relaxation of SDR is tight and analyze the complexity of proposed algorithms. Finally, simulation results validate the effectiveness and robustness of proposed scheme.

Mycoplasma pneumoniae의 성장과 형태에 미치는 환경요소적 영향 (Effects of environmental factors on growth and morphology of mycoplasma pneumoniae)

  • Kim, Chi-Kyung
    • 미생물학회지
    • /
    • 제16권3호
    • /
    • pp.131-139
    • /
    • 1978
  • Mycoplasma pneumoniae was examined for growth characteristics and morphology when cultivated in several media supplemented with a variety of sera and under different atmospheric conditions. different formula of the medium as well as different sources of lot numbers of the serum in the same medium exhibited varying effects on growth rate and adherence. When the organisms were cultivated in SSR-2 medium in a normal atmospheric environment or under a facultative anaerobic condition provided with carbon dioxide, they developed filamentous cells with heavy growth, whereas mainly round-shaped cells were produced under strict anaerobic conditions of hydrogen and carbon dioxide. Both morphologies of the organism were transformed by switching the incubation environments. An inverted phasecontrast microscopy using modified petri dishes was excellent to observe single cells and useful to follow the development of the cells. Growth, turbidity, and pneumoniae colonies developed on a solid medium and produced clear when overlaid with sheep blood agar.

  • PDF

Efficient Message Scheduling for WDM Optical Networks with Minimizing Flow Time

  • Huang, Xiaohong;Ma, Maode
    • Journal of Communications and Networks
    • /
    • 제6권2호
    • /
    • pp.147-155
    • /
    • 2004
  • In this paper, we propose an efficient sequencing technique, namely minimum Row time scheduling (MFTS), to manage variable-Iength message transmissions for single-hop passive starcoupled WDM optical networks. By considering not only the message length but also the state of the receivers and the tuning latency, the proposed protocol can reduce the average delay of the network greatly. This paper also introduces a new channel assignment technique latency minimizing scheduling (LMS), which aims to reduce the scheduling latency. We evaluate the proposed algorithm, using extensive discrete-event simulations, by comparing its performance with shortest job first (SJF) algorithm. We find that significant improvement in average delay could be achieved by MFTS algorithm. By combining the proposed message sequencing technique with the channel selection technique, the performance of the optical network could be further improved.

대용량 인버터의 병렬운전 (Parallel Operation of High Power Inverters)

  • 이현동;지준근;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.150-152
    • /
    • 1994
  • This paper deals with the parallel operation of inverters. To enlarge capacity of inverter system and reduce current ripples on inverter output side, two or more inverters are operated in parallel. Up to now six-step inverters and sinusoidal PWM inverters are considered in parallel operation, but using space-vector PWM inverters we can get many advantages of reducing ripple current energy and torque ripple and so on. As we can choose effective voltage vectors more freely than single operation, inverter output current ripples can be reduced by shifting beginning and end point of switching state back and forth.

  • PDF

수용가 전원 응용을 위한 단상 Buck AC-AC 전력 변환기 (A Single-Phase Buck AC-AC Power Converter for Custom Power Applications)

  • 강정식;최남섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.427-430
    • /
    • 2001
  • 산업분야에서 많이 사용되고 있는 컴퓨터나 자동화 제조공정 등은 순간적인 전압저하나 이상전압에 매우 민감하게 반응한다. 부하에 공급되는 전력의 신뢰도의 문제가 증가함에 따라 수용가 측에서는 무정전 전원장치(UPS)와 같은 일정전압을 유지한 수 있는 전력 조절장치들을 사용하고 있다. 본 논문에서는 수용가 전원의 안정화를 위한 제어장치로서 단상 Buck AC-AC 전지변환기를 제안한다. 제안된 전력변환기는 IGBT스위칭 모듈을 사용하고 전압의 저하가 발생했을 때 펄스폭 변조(PWM) 제어에 의하여 일정한 전압을 유지할 수 있다. 본 논문에서는 정상상태에서의 동작특성을 해석하고 PSPICE 시뮬레이션으로 동작특성을 확인한다.

  • PDF

Single-Phase Bridgeless Zeta PFC Converter with Reduced Conduction Losses

  • Khan, Shakil Ahamed;Rahim, Nasrudin Abd.;Bakar, Ab Halim Abu;Kwang, Tan Chia
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.356-365
    • /
    • 2015
  • This paper presents a new single phase front-end ac-dc bridgeless power factor correction (PFC) rectifier topology. The proposed converter achieves a high efficiency over a wide range of input and output voltages, a high power factor, low line current harmonics and both step up and step down voltage conversions. This topology is based on a non-inverting buck-boost (Zeta) converter. In this approach, the input diode bridge is removed and a maximum of one diode conducts in a complete switching period. This reduces the conduction losses and the thermal stresses on the switches when compare to existing PFC topologies. Inherent power factor correction is achieved by operating the converter in the discontinuous conduction mode (DCM) which leads to a simplified control circuit. The characteristics of the proposed design, principles of operation, steady state operation analysis, and control structure are described in this paper. An experimental prototype has been built to demonstrate the feasibility of the new converter. Simulation and experimental results are provided to verify the improved power quality at the AC mains and the lower conduction losses of the converter.

지중송전계통에서 OF 및 XLPE 케이블 혼용 연계 운용의 효용성 평가 (Effectiveness Evaluation on Combined Connection Operation of OF and XLPE Cable)

  • 채직병;이종범
    • 전기학회논문지
    • /
    • 제64권6호
    • /
    • pp.857-863
    • /
    • 2015
  • OF cable with excellent reliability and economic efficiency, has been used as the main cable of underground transmission in Korea. However, as XLPE cable is excellent in view points such as reduction of loss, convenience on the construction/operation, and manufacturing technology, it has been replaced as instead of OF cable. Also, when the aging occurs in some sections of OF cable, the section is replaced as XLPE cable without changing of whole cable line. However, there are some differences like electrical constants between both types of cables. Therefore if underground transmission system will be operated as combined connection composited of both cables, it should be proved that overvoltage is stable in steady and transient state. This paper describes the effectiveness of connection operation in combined OF and XLPE cable. For the evaluation of effectiveness, some important analysis such as sheath component voltage, lightning and switching overvoltage, single line-to-ground fault are carried out in steady and transient state. EMTP/ATPDraw is used for modeling and analysis of system.