OF cable with excellent reliability and economic efficiency, has been used as the main cable of underground transmission in Korea. However, as XLPE cable is excellent in view points such as reduction of loss, convenience on the construction/operation, and manufacturing technology, it has been replaced as instead of OF cable. Also, when the aging occurs in some sections of OF cable, the section is replaced as XLPE cable without changing of whole cable line. However, there are some differences like electrical constants between both types of cables. Therefore if underground transmission system will be operated as combined connection composited of both cables, it should be proved that overvoltage is stable in steady and transient state. This paper describes the effectiveness of connection operation in combined OF and XLPE cable. For the evaluation of effectiveness, some important analysis such as sheath component voltage, lightning and switching overvoltage, single line-to-ground fault are carried out in steady and transient state. EMTP/ATPDraw is used for modeling and analysis of system.
Keywords
OF Cable; XLPE Cable; Combined connection operation; EMTP;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Jik-Byoung Chea, et al., “Transient Phenomena Analysis in Combined Connection System of OF and XLPE Cable” KIEE Summer Conference, pp. 342- 343, July 2014.
2 IEEE Std. 634, "IEEE Standard Cable Penetration Fire Stop Qualification Test", 1978.

3 KEPRI, "A Study on the Reduction of Induced Voltage and Circulating Current at the Metallic Sheath of Underground Transmission Power Cables", 2003.
4 J.W. Kang, et al., "Analysis of temperature and energy characteristic of OF Cable", KIEE, pp. 721 -723, July 2005.
5 Kwang-Man Ko, et al., "Switching Overvoltage Analysis according to Length Variation of Arrestor Lead Wire in Service Entrance of Combined Transmission Line” KIEE Summer Conference, pp. 296-297, July 2014.
6 CIGRE KOREA, "Underground Cable System Engineering", 2014.
7 Soon-Chul Hwang, et al., "The Application of 154kV OF/XLPE Transition Joint", KIEE, pp. 274- 276, July 1991.
8 H,J, Kim, "Development of Transition Joint fo 154kV OF Cable and XLPE Cable", KIEE, pp. 1826 -1828, July 2004.