• Title/Summary/Keyword: Single-phase T-type inverter

Search Result 9, Processing Time 0.032 seconds

Design of Odd Harmonic Repetitive Controller for Uninterruptible Power Supply (무정전 전원장치를 위한 홀수고조파 반복제어기의 설계)

  • Yoon, Chun-gi;Cho, Younghoon;Lim, Seung-beom
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.147-148
    • /
    • 2015
  • This paper presents an odd harmonic repetitive controller for single-phase UPS inverters. The proposed repetitive controller achieves the low output voltage THD and reduces the steady-state error by eliminating odd harmonic distortions caused by nonlinear and unbalanced loads. The proposed control scheme is verified through experiment using a 5kW single-phase T-type inverter.

  • PDF

Pulse Width and Pulse Frequency Modulated Soft Commutation Inverter Type AC-DC Power Converter with Lowered Utility 200V AC Grid Side Harmonic Current Components

  • Matsushige T.;Ishitobi M.;Nakaoka M.;Bessyo D.;Yamashita H.;Omori H.;Terai H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.484-488
    • /
    • 2001
  • The grid voltage of commercial utility power source hi Japan and USA is 100rms, but in China and European countries, it is 200rms. In recent years, In Japan 200Vrms out putted single phase three wire system begins to be used for high power applications. In 100Vrms utility AC power applications and systems, an active voltage clamped quasi-resonant Inverter circuit topology using IGBTs has been effectively used so far for the consumer microwave oven. In this paper, presented is a half bridge type voltage-clamped high-frequency Inverter type AC-DC converter using which is designed for consumer magnetron drive used as the consumer microwave oven in 200V utility AC power system. This zero voltage soft switching Inverter can use the same power rated switching semiconductor devices and three-winding high frequency transformer as those of the active voltage clamped quasi-resonant Inverter using the IGBTs that has already been used for 100V utility AC power source. The operating performances of the voltage source single ended push pull type Inverter are evaluated and discussed for consumer microwave oven. The harmonic line current components In the utility AC power side of the AC-DC power converter operating at ZVS­PWM strategy reduced and improved on the basis of sine wave like pulse frequency modulation and sine wave like pulse width modulation for the utility AC voltage source.

  • PDF

Effect of Pulse Width Modulation Methods on Power Losses and Thermal Loadings of Single-Phase 5-Level NPC Inverters for PV Systems (전압 변조 방법에 따른 단상 5-레벨 NPC 태양광 인버터의 전력 손실 및 열 부하 분석)

  • Ryu, Taerim;Choi, Ui-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.1
    • /
    • pp.56-62
    • /
    • 2022
  • In this paper, the effect of pulse width modulation methods on thermal loadings and power losses of single-phase five-level NPC inverters for photovoltaic systems are analyzed. The pulse width modulation methods affect the power losses of the NPC inverters and thus lead to different thermal loadings of NPC inverters. To identify the reliability-critical power device with respect to thermal stress, the thermal loadings of I- and T-type NPC inverters are analyzed by applying the unipolar pulse modulation method. Then, the effect of the discontinuous pulse width modulation method on power losses and thermal loadings of power devices of I- and T-type NPC inverters are analyzed. Finally, the operation of NPC inverters applying the discontinuous pulse modulation method is confirmed by experiments. The results show that the discontinuous pulse modulation method is able to improve the reliability of NPC inverters by reducing thermal loadings of reliability-critical power devices and it is more effective for T-type NPC inverters than I-type NPC inverters.

Lifetime Evaluation of Power Devices of Single-Phase 5-Level NPC Inverters Considering Mission Profile of PV Systems (미션 프로파일을 고려한 단상 5-레벨 태양광 NPC 인버터의 전력 반도체 소자 수명 분석)

  • Ryu, Taerim;Choi, Ui-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.3
    • /
    • pp.221-227
    • /
    • 2022
  • The reliability improvement of PV systems is an important factor in reducing the cost of PV energy because it is closely related to the annual energy production as well as the maintenance cost of PV systems. The reliability of PV inverters plays a key role in the reliability of PV systems because it is regarded as one of the most reliable critical parts of PV systems. The lifetime evaluation of PV inverters considering the mission profile in the design phase plays an important role in reliability design to ensure the required lifetime of PV inverters. In this paper, the lifetime of representative single-phase T-type and I-type NPC inverters are comparatively evaluated by considering the mission profile of a PV system recorded at Iza, Spain. Furthermore, the effect of the pulse width modulation methods on the lifetime is also discussed. The lifetime evaluation of PV inverters is performed at the component-level first and then the system level by considering all power devices.

Development of Uninterruptible Power Supply with Voltage Sag Restorer Function (순시전압강하 보상 기능을 가지는 무정전전원공급장치의 개발)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.95-101
    • /
    • 2014
  • In this paper, UPS, with a built-in instantaneous sag drop compensation features, was developed to improve performance. The improved UPS, using instantaneous moving average method, compensates by quickly measuring the voltage and series inverter of half-bridge type, using line-interactive method that links with the voltage of the battery and power source, was developed. In addition, by developing a parallel inverter that uses a high-efficiency PWM switching method, overall UPS system was enhanced. To verify the performance of the proposed algorithm, single-phase 5[kVA] UPS systems were designed and the experimental system was constructed. The low-cost type of Cortex-M3 module CPU STM32F103R8T6 (32[bit]) is attached and the switching time of mode transfer was set within 4 [ms]. THD of the linear load operates in less than 3[%], and the stability of the output voltage operates in approximately ${\pm}2[%]$ range. The superior performance of the operations was confirmed with the system set as above.

A Single-Phase Hybrid Multi-Level Converter with Less Number of Components

  • Kim, Ki-Mok;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.105-107
    • /
    • 2018
  • This paper presents a new hybrid multilevel converter topology, which consists of a combination of the series connected switched capacitor units with boost ability, and an H-bridge with T-type bidirectional switches. The proposed converter boosts the input voltage without any bulky inductors, and has the small number of components, which can make the size and cost of a power converter greatly reduced. The output filter size and harmonics are also reduced by the high quality multilevel output. In addition, there is no need for complicated methods to balance the capacitor voltage. Simulation and experimental results with a nine-level converter system are presented to validate the proposed topology and modulation method.

  • PDF

The Study on the Image Quality and Patient Exposure Dose of Chest Radiography in Korea (흉부촬영시 피폭선량과 화질에 관한 조사연구)

  • Lee, Sun-Sook;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.18 no.2
    • /
    • pp.49-59
    • /
    • 1995
  • Recently, general radiography became to variety because of the continuous development of Inverter type generator and ortho chromatic system. Therefore, we must re-evaluate about patient exposure dose and image quality. I studied about chest radiography which has frequency among general radiography being used during FEB. to AUG., 1994 over 151 medical facilities from medical facilities that are located in Seoul area. The result obtained were as follows ; 1) The rectification method of the generator were employing mainly single phase full wave in 82.8 %, three phase full wave in 11.26 % and Inverter type in 4.64 % and condenser type is 1.32 %. 2) Exposure kV was used below 80 kV in most medical facilities and 21.8 % of the medical facilities was using high tube voltage higher than 120 kV. 3) The exposure time was used below the 0.05 sec in 28.4 %, in 29.8 % of the medical facilities used above 0.1 sec. 4) The usage frequency of the added filter is 15.3 %, and among them compound filter was used only 4 %. 5) Rare earth screen was used in 37.7 %. 6) The average skin entrance dose was 0.25 mSv, the range of dose is $0.05{\sim}0.79\;mSv$ in each medical facilities. 7) The average density of the lung field is 1.76, 0.49 in lung side, 0.30 in mediastinum and 0.37 in heart shadow. Therefore it is required to improve all of these for increasing image quality and reducing patient exposure dose as soon as possible.

  • PDF

The Improvement of Transient State Characteristics with Voltage Type PWM Conbverter Control (전압형 PWM 컨버터 제어에의한 과도상태의 특성 개선)

  • 이상일;이진섭;백형래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.268-274
    • /
    • 1999
  • The problem of power factor and hmmonics are occurred in convelter system which used to SCRs and diodes as p power semiconductor devices. IGBT power device with selh:ommutation type was solved that problem. maintain the l input line current with sinusoidal wave CUlTent of input power source voltage. It was estimated that improvement of t transient state characteristics with feedfolward compensator added in the diode rectifier with single phase voltage type i inverter was used to simulation load. As a results it was verified that the transient state characteristics with voltage t type PWM convelter control was improved.

  • PDF

A Ripple Rejection Inherited RPWM for VSI Working with Fluctuating DC Link Voltage

  • Jarin, T.;Subburaj, P.;Bright, Shibu J V
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2018-2030
    • /
    • 2015
  • A two stage ac drive configuration consisting of a single-phase line commutated rectifier and a three-phase voltage source inverter (VSI) is very common in low and medium power applications. The deterministic pulse width modulation (PWM) methods like sinusoidal PWM (SPWM) could not be considered as an ideal choice for modern drives since they result mechanical vibration and acoustic noise, and limit the application scope. This is due to the incapability of the deterministic PWM strategies in sprawling the harmonic power. The random PWM (RPWM) approaches could solve this issue by creating continuous harmonic profile instead of discrete clusters of dominant harmonics. Insufficient filtering at dc link results in the amplitude distortion of the input dc voltage to the VSI and has the most significant impact on the spectral errors (difference between theoretical and practical spectra). It is obvious that the sprawling effect of RPWM undoubtedly influenced by input fluctuation and the discrete harmonic clusters may reappear. The influence of dc link fluctuation on harmonics and their spreading effect in the VSI remains invalidated. A case study is done with four different filter capacitor values in this paper and results are compared with the constant dc input operation. This paper also proposes an ingenious RPWM, a ripple dosed sinusoidal reference-random carrier PWM (RDSRRCPWM), which has the innate capacity of suppressing the effect of input fluctuation in the output than the other modern PWM methods. MATLAB based simulation study reveals the fundamental component, total harmonic distortion (THD) and harmonic spread factor (HSF) for various modulation indices. The non-ideal dc link is managed well with the developed RDSRRCPWM applied to the VSI and tested in a proto type VSI using the field programmable gate array (FPGA).