• 제목/요약/키워드: Single-Phase transformer

검색결과 211건 처리시간 0.044초

자기적 비선형발생을 고려한 변칙적자동분석의 유한요소해석에 관한 연구 (A Study on the Analysis for the Nonlinear Magnetic Flux Distribution of a Transformer by Finite Element Method)

  • Dal-Ho Im;Chan-O Kim
    • 대한전기학회논문지
    • /
    • 제32권12호
    • /
    • pp.419-426
    • /
    • 1983
  • This study is to analyze the nonlinear characteristics of magnetic flux distribution of a transformer by Finite Element Method using 2-dimensional elements. To accomplish this, first a single phase shell-type transformer is selected a model to be analyzed, and the element equation is derived by the vriational approach. And then using the numerical approximation of a magnetization curve and the Direct Convergence Method which is presented in this study, the magnetic nonlinear characteristic is analyzed. In this consequence, the resultant values are converged within 10 iterations of calculation. And in the comparison with the case of linear analysis, these results are more accurate and reasonable.

고온초전도변압기의 특성시험 (Test of an High Temperature Superconducting Power Transformer)

  • 이희준;차귀수;이지광;김우석;한송엽;류경우;최경달
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권9호
    • /
    • pp.572-577
    • /
    • 2000
  • This paper describes the test results of a single phase 3kVA high temperature superconducting power transformer. The tapes are made with Bi-2223 and have silver alloy as the matrix. Four double pancake windings are used. Among them two double pancake windings are connected in series for high voltage winding and the others are connected in parallel for low voltage winding. The rated voltage and current of primary winding and secondary winding are 220/110V. 13.7/27.3A. Fundamental characteristics are obtained through short circuit and no load test. The over load capability and characteristics are investigated.

  • PDF

UHF 부분방전 신호를 이용한 전력용 변압기 내부의 부분방전 위치 추정 (Localization of partial discharge in power transformer by detecting UHF PD signal)

  • 주형준;구선근;한기선;박기준;윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.147-148
    • /
    • 2008
  • In this paper two kinds of techniques were compared for localization of PD(partial discharge) in power transformer and more useful method was suggested. Both of them, the time of arrival and the energy content method, were tested in 154kV single phase experimental transformer using UHF signal measurement. The former was using the difference of arrival time of recorded signals from four UHF sensors, the latter was based on the energy content in frequency spectra of signals detected at all sensors.

  • PDF

발전소용 외철형 765kV 변압기 개발 (Development of 765kV Shell Type Transformers for Generator Step-up)

  • 김영민;김도균;조광제;배용배
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권12호
    • /
    • pp.515-519
    • /
    • 2005
  • We have developed shell type 765kV transformers for generator step-up. Our research and development for shell type 765kV transformers have been continued since 1990. The shell type 765kV transformers of single phase 3MVA for step-up and 500MVA for power transmission were developed in Dec. 1992 and Oct. 1996, respectively. 204MVA 765kV transformer for generator step-up was also developed with the basis of technique and experience to the present. Total 12 phases of 204MVA 765kV transformers will be delivered at Tangjin thermal power plant by 2006. This paper describes electrical and structural features of the shell type 204MVA 765kV transformer.

고주파링크 방식을 이용한 계통연계형 태양광발전시스템 (High frequency Linked Grid-Connected PV System for Residential Use)

  • 정영석;유권종;이수홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.467-469
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier, four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

소형초전도변압기의 전기적 기초특성 (Fundamental characteristics of a small superconducting transformer)

  • 오봉환;한태희;나완수;조전욱;이언용;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.52-54
    • /
    • 1994
  • To demonstrate the applicability of super-conductors to electric power machines, the authors made and tested a small single-phase superconducting transformer. The aim of the study was to determine the fundamental properties of superconducting trans former. Therefore the superconducting transformer has a simple structure, i.e. the high voltage to low one ratio is 2:1 and the iron core is immersed in liquid helium. Fundamental characteristics are obtained through no-load and short-circuit tests. In this paper, the experimental results are described.

  • PDF

고주파링크 방식을 이용한 계통연계형 태양광발전시스템 (Utility Interactive Inverter with High-frequency Link for Photovoltaic Power System)

  • 정영석;유권종;이수홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1050-1052
    • /
    • 2000
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system (3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation. a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

계통연계형 태양광발전시스템을 위한 고주파 DC 링크 인버터 (High-Frequency DC Link Inverter for Grid-connected PV System)

  • 정영석;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.46-49
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kVA) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kVA high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier. four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Analysis of a Harmonics Neutralized 48-Pulse STATCOM with GTO Based Voltage Source Converters

  • Singh, Bhim;Saha, Radheshyam
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.391-400
    • /
    • 2008
  • Multi-pulse topology of converters using elementary six-pulse GTO - VSC (gate turn off based voltage source converter) operated under fundamental frequency switching (FFS) control is widely adopted in high power rating static synchronous compensators (STATCOM). Practically, a 48-pulse ($6{\times}8$ pulse) configuration is used with the phase angle control algorithm employing proportional and integral (PI) control methodology. These kinds of controllers, for example the ${\pm}80MVAR$ compensator at Inuyama switching station, KEPCO, Japan, employs two stages of magnetics viz. intermediate transformers (as many as VSCs) and a main coupling transformer to minimize harmonics distortion in the line and to achieve a desired operational efficiency. The magnetic circuit needs altogether nine transformers of which eight are phase shifting transformers (PST) used in the intermediate stage, each rating equal to or more than one eighth of the compensator rating, and the other one is the main coupling transformer having a power rating equal to that of the compensator. In this paper, a two-level 48-pulse ${\pm}100MVAR$ STATCOM is proposed where eight, six-pulse GTO-VSC are employed and magnetics is simplified to single-stage using four transformers of which three are PSTs and the other is a normal transformer. Thus, it reduces the magnetics to half of the value needed in the commercially available compensator. By adopting the simple PI-controllers, the model is simulated in a MATLAB environment by SimPowerSystems toolbox for voltage regulation in the transmission system. The simulation results show that the THD levels in line voltage and current are well below the limiting values specified in the IEEE Std 519-1992 for harmonic control in electrical power systems. The controller performance is observed reasonably well during capacitive and inductive modes of operation.

A PSpice Modeling of PFC Circuit Using Soft-Switched Boost Converter

  • Mok, H.S.;Choe, G.H.;Jeong, S.E.;Choi, J.Y.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.393-399
    • /
    • 1997
  • Single-phase and three-phase AC to DC power converters are becoming frequently used for high voltage/high power applications such as telecommunications. They often require input/output transformer isolation for safety, a unity input power factor for minimum reactive power, free input harmonic currents fed back to the AC Power distribution system and, finally, high efficiency and high power density for minimum weight and volume. The proposed boost converter for power factor correction (PFC) provides an unity input power factor, low harmonic distortion and high efficiency along with reduced volume and weight. Single-phase 220VAC input/380VDC 1KW output prototype is constructed and experimental results will be verified with those of PSpice simulation.

  • PDF