• 제목/요약/키워드: Single-Phase

검색결과 5,311건 처리시간 0.037초

단상 배전 STATCOM을 이용한 전기철도시스템의 전압강하 및 전력품질 향상 (Compensation of voltage drop and improvement of power quality at AC railroad system with single-phase distributed STATCOM)

  • 김준상;김진오;이준경;정현수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.192-193
    • /
    • 2006
  • An AC electrical railroad system has rapidly changing dynamic single-phase load, and at a feeding substation, three-phase electric power is transformed to the paired directional single-phase electric power. There is a great difference in electrical phenomenon between the load of AC electrical railroad system and that of general power system. Electric characteristics of AC electrical railroad's trainload are changed continuously according to the traction, operating characteristic, operating schedule, track slope, etc. Because of the long feeding distance of the dynamic trainload, power quality problems such as voltage drop, voltage imbalance and harmonic distortion may also occur to AC electrical railroad system. These problems affect not only power system stability. but also power quality deterioration in AC electrical railroad system. The dynamic simulation model of AC electrical railroad system presented by PSCAD/EMTDC is modeled in this paper, and then, it is analyzed voltage drop and power quality for AC electrical railroad system both with single-Phase distributed STATCOM(Static Synchronous Compensator) installed at SP(Sectioning Post) and without.

  • PDF

A Single-phase Harmonics Extraction Algorithm Based on the Principle of Trigonometric Orthogonal Functions

  • Yi, Hao;Zhuo, Fang;Wang, Feng;Li, Yu;Wang, Zhenxiong
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.253-261
    • /
    • 2017
  • For a single-phase active power filter (APF), designing a more efficient algorithm to guarantee accurate and fast harmonics extraction with a lower computing cost is still a meaningful topic. The common idea still employs a IRPT-based Park transform, which was originally designed for 3-phase applications. Therefore, an additional virtual signal generation (VSG) link is necessary when it is used in the single-phase condition. This method, with virtual signal generation and transform, is obviously not the most efficient one. Regarding this problem, this paper proposes a novel harmonics extraction algorithm to further improve efficiency. The new algorithm is based on the principle of trigonometric orthogonal functions (TOF), and its mathematical principle and physical meaning are introduced in detail. Its implementation and superiority in terms of computation efficiency are analyzed by comparing it with conventional methods. Finally, its effectiveness is well validated through detailed simulations and laboratory experiments.

Single-Phase Inverter for Grid-Connected and Intentional Islanding Operations in Electric Utility Systems

  • Lidozzi, Alessandro;Lo Calzo, Giovanni;Solero, Luca;Crescimbini, Fabio
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.704-716
    • /
    • 2016
  • Small distributed generation units are usually connected to the main electric grid through single-phase voltage source inverters. Grid operating conditions such as voltage and frequency are not constant and can fluctuate within the range values established by international standards. Furthermore, the requirements in terms of power factor correction, total harmonic distortion, and reliability are getting tighter day by day. As a result, the implementation of reliable and efficient control algorithms, which are able to adjust their control parameters in response to changeable grid operating conditions, is essential. This paper investigates the configuration topology and control algorithm of a single-phase inverter with the purpose of achieving high performance in terms of efficiency as well as total harmonic distortion of the output current. Accordingly, a Second Order Generalized Integrator with a suitable Phase Locked Loop (SOGI-PLL) is the basis of the proposed current and voltage regulation. Some practical issues related to the control algorithm are addressed, and a solution for the control architecture is proposed, based on resonant controllers that are continuously tuned on the basis of the actual grid frequency. Further, intentional islanding operation is investigated and a possible procedure for switching from grid-tied to islanding operation and vice-versa is proposed.

1선지락사고에 대한 초전도한류기의 동작특성 (Operating properties of resistive type superconducting fault current limiters with a single line-to-ground fault)

  • Park, Hyo-Sang;Park, Chang-Joo;Lee, Sang-il;Chung, Soo-Bok;Oh, Geum-Kon;Chung, Hun-Sang
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.279-281
    • /
    • 2003
  • We analysed the operating properties of resistive type superconducting fault current limiters (SFCLs) based on YBCO thin films with a single line-to-ground fault. When a single line-to-ground fault occurred, the short circuit current of a fault phase increased up to about 6 times of transport currents immediately after the fault instant and was effectively limited to the designed current level within 2 ms by the resistance development of the SFCL. The fault currents of the sound phases almost did not change because of their direct grounding system. The unsymmetrical rates of a fault phase were distributed from 6.4 to 1.4. It was found that the unsymmetrical rates of currents were noticeably improved within one cycle after the fault instant. We calculated the zero phase currents for a single line-to-ground fault using the symmetrical component analysis. The positive sequence resistance was reduced remarkably right after the fault but eventually approached the balanced positive resistance component prior to the system fault. This means that the system reaches almost the three-phase symmetrical state in about 60 ㎳ after the fault. The ground currents were almost 3 times of the zero phase mts since most of the fault currents flowed through the grounding line.

  • PDF

11kW 5.58kW/L 무(無)전해커패시터 단상/3상 겸용 전기자동차 탑재형 충전기 (A 11 kW 5.58 kW/L Electrolytic Capacitor-less EV Charger With Single- and Three-Phase Compatibility)

  • 김형진;박준영;김선주;라마단;기에우 흐우 푹;최세완
    • 전력전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.277-284
    • /
    • 2021
  • A single and three phase-compatible single-stage EV charger without electrolytic capacitor is proposed in this study. DC battery-charging current is inherently guaranteed in the three-phase grid due to three output currents with a phase shift of 120° between each other. The proposed EV charger can provide a DC battery charging current for the single-phase grid through the integrated active power decoupling circuit without using additional switches. The proposed EV charger ensures ZVS turn-on of all switches with wide grid and battery voltage ranges. The 11 kW prototype of the proposed EV charger demonstrates a peak efficiency of 97.01% and a power density of 5.58 kW/L.

자기 포화 영역을 갖는 단상 6/6 SRM의 자기 구조 해석 및 개선 (Analysis and Improvement for Single 6/6 SRM with a Saturable Area)

  • 오석규
    • 한국자기학회지
    • /
    • 제27권2호
    • /
    • pp.70-75
    • /
    • 2017
  • 단상 SRM은 자기동이 어려운 관계로 다양한 방법으로 자기동을 실현시키려는 연구가 진행되고 있다. 보조자석을 사용하거나 보조극 등을 만들어 자기동을 실현시키는 방법들이 연구되고 있다. 최근에 회전자 형상에 변화를 주어 기동할 수 있는 방법이 제시되었다. 이는 회전자 형상에 변화를 주어 부분적으로 자기포화 정도를 다르게 하여 자기동을 실현하는 방식이다. 본 논문에서는 자기 포화 영역을 갖는 단상 6/6 SRM의 자기구조를 해석하고 기존의 자기구조를 개선하는 것을 목적으로 한다. 이 자기 해석을 위해 유한요소법 해석 프로그램인 FLUX2D를 사용하였다.

상태관측기를 이용한 단상 PLL제어의 성능 개선 (Performance Improvement of Single-phase PLL Control using State Observer)

  • 황희훈;최종우
    • 전력전자학회논문지
    • /
    • 제14권2호
    • /
    • pp.96-104
    • /
    • 2009
  • 본 논문에서는 단상 전원의 위상 및 주파수 검출을 위해 전차원 상태관측기를 이용한 가상 2상 방식의 단상 위상고정루프(PLL: Phase Locked Loop) 제어기를 제안한다. 기존의 방식은 전원단에 주입된 저차 고조파를 완벽하게 제거하지 못하여 전체 PLL 시스템에 영향을 주게 된다. 제안된 알고리즘은 전차원 상태관측기를 사용하여 기본파와 고조파를 분리하고 고조파 성분을 효과적으로 제거 및 검출하여 기본파 성분만을 발생한다. 그리고 가상 발생신호 및 기존 입력신호를 함께 제어함으로써 기존방식보다 정상상태 오차를 감소시킬 수 있다. 모의실험결과 및 실제실험결과를 통하여 설계한 제어기에 의해 발생된 주파수가 실제값에 수렴하였으며 정상상태 추정 특성이 향상됨을 검증하였다. 또한 고조파 성분이 효과적으로 제거되고 기본파 성분만을 출력하는 것을 확인하였다.

Oxygen Deficiency, Hydrogen Doping, and Stress Effects on Metal-Insulator Transition in Single-Crystalline Vanadium Dioxide Nanobeams

  • 홍웅기;장성진;박종배;배태성
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.424.1-424.1
    • /
    • 2014
  • Vanadium dioxide (VO2) is a strongly correlated oxide exhibiting a first-order metal-insulator transition (MIT) that is accompanied by a structural phase transition from a low temperature monoclinic phase to a high-temperature rutile phase. VO2 has attracted significant attention because of a variety of possible applications based on its ultrafast MIT. Interestingly, the transition nature of VO2 is significantly affected by stress due to doping and/or interaction with a substrate and/or surface tension as well as defects. Accordingly, there have been considerable efforts to understand the influences of such factors on the phase transition and the fundamental mechanisms behind the MIT behavior. Here, we present the influences of oxygen deficiency, hydrogen doping, and substrate-induced stress on MIT phenomena in single-crystalline VO2 nanobeams. Specifically, the work function and the electrical resistance of the VO2 nanobeams change with the compositional variation due to the oxygen-deficiency-related defects. In addition, the VO2 nanobeams during exposure to hydrogen gas exhibit the reduction of transition temperature and the complex phase inhomogenieties arising from both substrate-induced stress and the formation of the hydrogen doping-induced metallic rutile phase.

  • PDF

2상 유동 모델의 일반적인 유도 (General Derivation of Two-Fluid Model)

  • Hee Cheon No
    • Nuclear Engineering and Technology
    • /
    • 제16권1호
    • /
    • pp.1-10
    • /
    • 1984
  • 2상 유동에 대한 일반적인 시간과 공간에 대해 평균된 보존방정식과 jump condition을 유도했다. 단상난류 유동 방정식에 사용되는 방법을 써서, 한부분에서 순간적으로 이루어지는 평형 방정식 (local instant balance eq.)으로부터 2상유동내 단상영역에 관한 시간에 대해 평균된 방정식을 유체체적에 대해 적분하여 얻어진 결과는 공간적으로 두차례에 걸쳐 평균된다. 즉, 한 유체체적내에서 일차적으로 k번째 상의 단상영역에 대해 평균하고 다음에 k번째 상 전체체적에 대해 평균한다. 질량, 운동량 그리고 에너지 보존 방정식은 일반적인 시간과 공간에 대해 평균된 방정식으로부터 얻어진다. 이 모델의 장점은 Ishii모델, 그리고 Banerjee의 model과 비교하여 설명된다. 마지막으로, THERMIT-6S의 방정식에 포함된 가정과 근사항들에 대해 박혀둔다.

  • PDF

삼상 분리형 자속구속형 전류제한기의 동작 특성 분석 (Analysis of Operational Characteristics of Separated Three-Phase Flux-Lock SFCL)

  • 두승규;두호익;박충렬;김민주;김용진;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.289-289
    • /
    • 2008
  • We investigated the operational characteristics of the separated three-phase flux-lock type superconducting fault current limiter (SFCL). The single-phase lock type SFCL consist of two coils, which are wound in parallel through an iron core. The high-$T_c$ superconducting(HSTC) thin film connected in series with secondary coil. The separated three-phase flux-lock type SFCL consist of three single-phase flux-lock type SFCL. In a normal condition, the SFCL is not operate. When a fault occurs, the current of a HSTC thin film exceeds its critical current by fault current, the resistance of the HSTC thin film generated. Therefore fault current was limited by SFCL. The separated three-phase flux-lock type SFCL are operated in fault condition such as the the single line-to-ground fault, the double line-to-ground fault and the triple line-to-ground fault. The experimental results, the SFCL operational characteristics was dependent on fault condition.

  • PDF