• Title/Summary/Keyword: Single-Phase

Search Result 5,311, Processing Time 0.039 seconds

A Fault Indicator Generation Algorithm using Phase Angle of Zero-Sequence Current in Ungrounded System (비접지 계통에서 영상전류 위상을 이용한 고장표시 생성 알고리즘)

  • Lim, Hee-Taek;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1141-1149
    • /
    • 2008
  • Most faults are single-phase-to-ground fault in ungrounded system. The fault currents of single-phase-to-ground are much smaller than detection thresholds of measurement devices, so detecting single-phase-to-ground faults is difficult and important in ungrounded system. This paper proposed to a FI(Fault Indicator) generation algorithm in ungrounded system. The algorithm just using line-to-line voltage and zero-sequence current detects fault line, fault phase, fault section and FI(Fault Indicator) at terminal device, This paper also proposed to application plan for this algorithm. In the case study, the proposed algorithm has been testified in demo system by Matlab/Simulink simulations.

A Study on Radiation Quality of the Diagnostic X-ray Equipments (진단용(診斷用) X-선장치(線裝置)의 선질(線質) 특성(特性)에 관(關)한 연구(硏究))

  • Park, Myeong-Hwan;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.55-59
    • /
    • 1997
  • The quality of continuous X-ray beam depends upon the half value layer which varies according to the geometric conditions, filtration thickness, and tube voltage. We compared the inverter type X-ray equipment with the conventional single phase 2 peak and the three phase 12 peak for the quality obtained by changes of the added filter thickness and the tube voltage. The quality of single phase 2 peak X-ray generator showed increase for the added filter and the tube volt-age. The half value layer is Increased the thicker the filter and the higher the kVp. The quality of the Inverter type and the three phase 12 peak in comparison with the single phase 2 peak X-ray generator is increased.

  • PDF

The Speed Character Measurements of the Single Phase SRM by using the Unipolar driving curcuit (유니폴라 구동회로를 이용한 단상 SRM의 속도 특성 측정)

  • Kim, Yong-Heon;Lee, Eun-Woong;Lee, Jong-Han;Jo, Yeon-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.887-888
    • /
    • 2006
  • Switched Reluctance Motor(SRM) is rotated by reluctance force generated between rotor pole and stator pole. So SRM must be switched by exciting current according to rotor position. but SRM takes the advantages of high speed driving and very simple structure. The single phase SRM can not be start by itself and torque ripple is generated more than multi-phase SRM. But mechanical structure and driver is simpler than multi-phase SRM. The single phase SRM driver is composed with the absolute encoder and DSP to control exciting section and current, and is supplied by constant voltage. So The paper is intend to measure the speed charactrer of double silent pole type SRM by using the unipolar driving curcuit.

  • PDF

The Analysis of the Inductance Profile in the Single Phase SRM for Blower (송풍기 구동용 단상 SRM의 인덕턴스 해석)

  • Lee Jong-Han;Lee Eun-Woong;Kim Yong-Heon;Ku Tae-Man
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1025-1027
    • /
    • 2004
  • Recently, the Single phase SRM has been researched and developed in many appliances with various types. This paper presents a theoretical representation of the phase inductance of a single phase SRM, as function of position and current, taking into account the non-linearity of the magnetic circuit. The method is based on the Fourier series expansion. the theoretical expressions for the calculation of instantaneous phase inductance, flux linkage, coenergy and electromagnetic torque as a function of rotor position and winding currents are derived. And it is compared with the results of the finite element analysis.

  • PDF

Drive of induction motor using three-phase inverter and voltage type PWM single-phase converter (전압형 PWM 단상 컨버터와 3상 인버터를 이용한 유도전동기의 운전)

  • 문상필;서기영;이현우;강욱중
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.18-24
    • /
    • 2001
  • This paper deals with a three-phase Pulse width Modulation(PWM) voltage souse inverter-induction motor drive with a single-phase PWM converter. The single-phase system has the pulsating instantaneous power with twice the frequency of the ac source. The power pulsation generates the dc voltage pulsation of the converter. In result, the waveforms of the inverter output current and voltage are distorted. The steady-stare operations of the system are analyzed by employing a state-spare method Such everything confirmed it's validity throughout simulation and experiment.

  • PDF

Modelling of Secondary Arc Using EMTP-RV (EMTP-RV를 이용한 2차 아크 모델링)

  • Oh, Yun-Sik;Kang, Sung-Bum;Seo, Hun-Chul;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.937-943
    • /
    • 2012
  • Most of faults occurred in transmission lines are single-phase to ground faults and transient faults. Single-phase auto reclosing is an appropriate scheme to maintain the system stability and restore the system effectively when those faults are occurred. In single-phase auto reclosing scheme, the secondary arc is generated after faulted phase is tripped to eliminate the fault and it is sustained by the capacitive and inductive coupling to the healthy phases. It is important to reclose the faulted phase after fully extinction of secondary arc because of the damage applied to system. Therefore, it is necessary to research on the detection of secondary arc extinction to ensure high success rate of reclosing. In this step, firstly, the accurate modelling of secondary arc should be performed. In this paper, the modelling of secondary arc is performed by using EMTP-RV and the simulation results show that the implemented model is correct and effective.

Fast Single-Phase All Digital Phase-Locked Loop for Grid Synchronization under Distorted Grid Conditions

  • Zhang, Peiyong;Fang, Haixia;Li, Yike;Feng, Chenhui
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1523-1535
    • /
    • 2018
  • High-performance Phase-Locked Loops (PLLs) are critical for grid synchronization in grid-tied power electronic applications. In this paper, a new single-phase All Digital Phase-Locked Loop (ADPLL) is proposed. It features fast transient response and good robustness under distorted grid conditions. It is designed for Field Programmable Gate Array (FPGA) implementation. As a result, a high sampling frequency of 1MHz can be obtained. In addition, a new OSG is adopted to track the power frequency, improve the harmonic rejection and remove the dc offset. Unlike previous methods, it avoids extra feedback loop, which results in an enlarged system bandwidth, enhanced stability and improved dynamic performance. In this case, a new parameter optimization method with consideration of loop delay is employed to achieve a fast dynamic response and guarantee accuracy. The Phase Detector (PD) and Voltage Controlled Oscillator (VCO) are realized by a Coordinate Rotation Digital Computer (CORDIC) algorithm and a Direct Digital Synthesis (DDS) block, respectively. The whole PLL system is finally produced on a FPGA. A theoretical analysis and experiments under various distorted grid conditions, including voltage sag, phase jump, frequency step, harmonics distortion, dc offset and combined disturbances, are also presented to verify the fast dynamic response and good robustness of the ADPLL.

Performance Comparison of Single-Phase PLL Algorithms Using Virtual 2-Phase Strategy (가상 2상 방식을 사용한 단상 PLL 알고리즘의 성능 비교)

  • Lee, Yong-Seok;Ji, Jun-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.226-228
    • /
    • 2006
  • This paper presents a comparative study of single-phase PLL algorithms using virtual 2-phase strategy. Simulation and experimental results, including operation of the PLL structures introduced in reference papers, are presented to allow a performance comparison of the PLL algorithms.

  • PDF

The Parallel Operation of Single Phase PWM Rectifier using IGBT (IGBT를 이용한 단산 PWM정류기 병렬운전)

  • 이현원;장성영;김연준;이광주;김남해
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.122-125
    • /
    • 1999
  • The AC-to-DC single-phase PWM rectifier for traction applications using high power semiconductor, IGCT is made and tested. Parallel operation of two PWM converter is adopted for increasing capacity of converters. For reducing harmonics, the harmonic content is eliminated by the phase shift between two converters switching phase. The output voltage control is achieved by interns calculation without detecting the input current. The part of PLL used for controlling power factor is simply implemented by software.

  • PDF

The Analysis of Characteristics for Digital PLL Control (디지털 PLL 제어의 특성 분석)

  • Kim Y.K.;Choi J.W.;Kim H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.548-553
    • /
    • 2003
  • The frequency and phase angle of the utility voltage are important in many industrial systems. this paper present a detailed analysis of single-phase digital PLL control for utility connected systems. and its performance under utility conditions with noise is discussed. The experimental results demonstrate phase tracking capability in the single-phase grid-connected operation.

  • PDF