• 제목/요약/키워드: Single shunt control

검색결과 26건 처리시간 0.027초

3상 인버터에서의 직류단 단일 션트 저항을 이용한 평균 상전류 추정 방법 (Average Phase Current Estimation Method using a DC Link Shunt Resistor in the Three-Phase Inverter)

  • 구현근;염한범;김장목
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.343-350
    • /
    • 2016
  • Generally, the average phase current is sampled at the midpoint of a PWM signal for the vector control of an AC motor. The three-phase current can also be reconstructed from a DC-link shunt resistor by sampling the shunt voltage during the active vectors of the SVPWM. However, the reconstructed current is different from the average current because of the deviation of the sampling point from the midpoint of the PWM signal. This paper proposes an algorithm to estimate the average current from the reconstructed current in a single-shunt inverter. The proposed method is derived from the phase current slopes based on switching states and corresponding switching time. In addition, the proposed method is generalized for all the six sectors of the space vector hexagon. The validity of the proposed algorithm is verified with simulations and experiments.

단상 능동 전력 조절 장치를 위한 새로운 제어기법 (A New Control Method for Single-Phase Active Power Line Contioners)

  • 서영조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.155-158
    • /
    • 2000
  • A new control method for single-phase shunt active power line conditioners(APLC's) operated under zero average power consumption is proposed in this paper. The amplitude of the sinusoidal source current which is in-phase with the source voltage can be determined from the average value of the instantaneous load power. Then the command current for the shunt APLC is obtained by subtraction the source current from the load current. Neither bulky filter nor time-consuming computation is required. The shunt power compensator supplies all the harmonics of he load current and the source only supplies the fundamental component,. Experimental results on a prototype verify the feasibility of the presented scheme,

  • PDF

압전분기회로를 이용한 보 구조물의 진동제어 파라미터 최적화 해석 (Parameter Optimization for Vibration Control of a Cantilever Beam Using Piezoelectric Shunt Damping System)

  • 임경채;조동수;박우철;기창두
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.918-921
    • /
    • 2005
  • According to the mechanical-electrical coupling characteristics and the electrical Impedance property of resistor-inductor-capacitor(RLC) series resonant circuit, the mechanical impedance analysis of a bimorph piezoceramic patch shunted with a series RLC resonant circuit is conducted. The displacement transfer function of a cantilever beam bonded with a piezoelectric shunt damping module is deduced in the case of single mode vibration of the beam. By the use of vibration damping theory of tuned mass damper system, the parameter optimization of piezoelectric shunt damping system is performed. The optimal resonant state of the shunting circuit can be obtained when the resister and conductor are optimally adjusted. Test results show that the vibration control effect as well improved with optimized piezoelectric shunt system.

  • PDF

Temporary Surgical Management of Intraventricular Hemorrhage in Premature Infants

  • Eun-Kyung Park;Ja-Yoon Kim;Dong-Seok Kim;Kyu-Won Shim
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권3호
    • /
    • pp.274-280
    • /
    • 2023
  • Post-hemorrhagic hydrocephalus (PHH) in preterm infant is common, life-threatening and the main cause of bad developmental outcomes. Ventriculoperitoneal (VP) shunt is used as the ultimate treatment for PHH. Low birth weight and low gestational age are the combination of worse prognostic factors while the single most important prognostic factor of VP shunting is age. Aggressive and early intervention have better effect in intraventricular hemorrhage and intracranial pressures control. It reduces infection rate and brain damage resulted in delayed shunt insertion. It is extremely important to let PHH infants get older and gain weight to have internal organs to be matured before undergoing VP shunt. As premature infants undergo shunt after further growth, shunt-related complications would be reduced. So temporary surgical intervention is critical for PHH infants to have them enough time until permanently shunted.

단상용 통합형 전력품질 개선장치의 개발에 관한 기초연구 (A Basic Study on the Development of the Single-Phase Unified Poorer Quality Conditioner)

  • 노대석;이현옥;오성철;최재석;차준민;김재언
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권2호
    • /
    • pp.90-98
    • /
    • 2003
  • Recently, the increasing application of electronic equipments and information devices has heightened the interest in power qualify. The term power quality is applied to a wide range of electromagnetic phenomena on the power system and is also concentrated by all areas such as utilities, their customers and suppliers of load equipments. In engineering terms, power Qualify is expressed by voltage qualify because the power supply system can only control the quality of the voltage. Therefore, the standards in power quality area are devoted to keep the supply voltage within allowable limits. This paper deals with single-phase unified power quality conditioner (UPQC), which ai s at the integration of series-active and shunt-active filter. The series filter il used to compensate for the voltage distortions and the shunt filter is used to provide reactive power and counteract the harmonic current injected by the load. Also, the voltage of the DC link capacitor is controlled to a desired value by the shunt active filter. The validity of the proposed UPQC is demonstrated using both the MATLAB/SIMULINK simulation and the experimental device with DSP (TMS320C32).

An Efficient FPGA based Real-Time Implementation Shunt Active Power Filter for Current Harmonic Elimination and Reactive Power Compensation

  • Charles, S.;Vivekanandan, C.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1655-1666
    • /
    • 2015
  • This paper proposes a new approach of Field Programmable Gate Array (FPGA) controlled digital implementation of shunt active power filter (SAPF) under steady state and dynamic operations. Typical implementations of SAPF uses microprocessor and digital signal processor (DSP) but it limited for complex algorithm structure, absence of feedback loop delays and their cost can be exceed the benefit they bring. In this paper, the hardware resources of an FPGA are configured and implemented in order to overcome conventional microcontroller or digital signal processor implementations. This proposed FPGA digital implementation scheme has very less execution time and boosts the overall performance of the system. The FPGA controller integrates the entire control algorithm of an SAPF, including synchronous reference frame transformation, phase locked loop, low pass filter and inverter current controller etc. All these required algorithms are implemented with a single all-on chip FPGA module which provides freedom to reconfigure for any other applications. The entire algorithm is coded, processed and simulated using Xilinx 12.1 ISE suite to estimate the advantages of the proposed system. The coded algorithm is also defused on a single all-on-chip Xilinx Spartan 3A DSP-XC3SD1800 laboratory prototype and experimental results thus obtained match with simulated counterparts under the dynamic state and steady state operating conditions.

Passive Suppression of Nonlinear Panel Flutter Using Piezoelectric Materials with Resonant Circuit

  • Moon, Seong-Hwan;Yun, Chul-Yong;Kim, Seung-Jo
    • Journal of Mechanical Science and Technology
    • /
    • 제16권1호
    • /
    • pp.1-12
    • /
    • 2002
  • In this study, a passive suppression scheme for nonlinear flutter problem of composite panel, which is believed to be more reliable than the active control methods in practical operations, is proposed. This scheme utilizes a piezoelectric inductor-resistor series shunt circuit. The finite element equations of motion for an electromechanically coupled system is derived by applying the Hamilton\\`s principle. The aerodynamic theory adopted for the present study is based on the quasi-steady piston theory, and von-barman nonlinear strain-displacement relation is also applied. The passive suppression results for nonlinear panel flutter are obtained in the time domain using the Newmark-$\beta$ method. To achieve the best damping effect, optimal shape and location of fille piezoceramic (PZT) patches are determined by using genetic algorithms. The effects of passive suppression are investigated by employing in turn one shunt circuit and two independent shunt circuits. Feasibility studies show that two independent inductor-resistor shunt circuits suppresses flutter more effectively than a single shunt circuit. The results clearly demonstrate that the passive damping scheme that uses piezoelectric shunt circuit can effectively attenuate the flutter.

A Four Leg Shunt Active Power Filter Predictive Fuzzy Logic Controller for Low-Voltage Unbalanced-Load Distribution Networks

  • Fahmy, A.M.;Abdelslam, Ahmed K.;Lotfy, Ahmed A.;Hamad, Mostafa;Kotb, Abdelsamee
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.573-587
    • /
    • 2018
  • Recently evolved power electronics' based domestic/residential appliances have begun to behave as single phase non-linear loads. Performing as voltage/current harmonic sources, those loads when connected to a three phase distribution network contaminate the line current with harmonics in addition to creating a neutral wire current increase. In this paper, an enhanced performance three phase four leg shunt active power filter (SAPF) controller is presented as a solution for this problem. The presented control strategy incorporates a hybrid predictive fuzzy-logic based technique. The predictive part is responsible for the SAPF compensating current generation while the DC-link voltage control is performed by a fuzzy logic technique. Simulations at various loading conditions are carried out to validate the effectiveness of the proposed technique. In addition, an experimental test rig is implemented for practical validation of the of the enhanced performance of the proposed technique.

전철 지중배전선로의 충전전류보상에 관한 연구 (A Study of the Charging Current Effect on Underground Distribution Line in Electric Railway)

  • 김양수;장우진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.214-218
    • /
    • 2008
  • Because on the high-tension underground distribution line of an electric railway high voltage XLPE Cable two or three circuits between railway stations with a standard as receiving transformer facilities are established at a $30km{\sim}50km$ interval, reactive power in which the phase of a current is larger than that of a voltage is supplied when trains are not working, so when there are no loading or low loading as night. Due to the long-distance trend of the underground distribution system on an alternating current railway distribution line, the terminal voltage of a transformer is over the standard voltage, and after all, commercial cycle overvoltage is continued. To solve this problem, the shunt reactor is installed in middle of power distribution lines to maintain receiver voltage meted under the allowance regulation through control of the reactive power. Also, in case that the thickness of single cable is over $60mm^2$ and length of line is about over 30km, a circuit breaker is broken by shorting shunt ability of charging current in excess of shunt current(31.5A.rms). Therefore, this thesis presents installing the location of shunt reactor for quantitative analysis by using optimum algorism for compensation and control of the charging current.

  • PDF

고조파 전류 제거를 위한 새로운 전류 보상 기법 (Novel Current Compensation Technique for Harmonic Current Elimination)

  • 정강률
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.587-591
    • /
    • 2004
  • This paper proposes a novel current compensation technique that can eliminate the harmonic currents included in line currents without computation of harmonic current components. A current controller with fast dynamics for an active filter is described. Harmonic currents are directly controlled without the need for sensing and computing the harmonic current of the load current, thus simplifying the control system. Current compensation is done in the time domain, allowing a fast time response. The DC voltage control loop keeps the voltage across the DC capacitor constant. High power factor control by an active filter is described. All control functions are implemented in software using a single-chip microcontroller, thus simplifying the control circuit. Any current-controlled synchronous rectifier can be used as a shunt active filter through only the simple modification of the software and the addition of current sensors. It is shown through experimental results that the proposed controller gives good performance for the shunt active filter.

  • PDF