• Title/Summary/Keyword: Single restoration

Search Result 354, Processing Time 0.029 seconds

Distribution and Population Dynamics of Korean Endangered Species; Hipparchia autonoe (Lepidoptera: Nymphalidae) on Mt. Hallasan, Jeju Island, Korea (한국산 멸종위기종 산굴뚝나비(나비목, 네발나비과)의 분포와 개체군 동태)

  • Kim, Do-Sung;Cho, Young-Bok;Kim, Dong-Soon;Lee, Yeong-Don;Park, Seong-Joon;Ahn, Nung-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.5
    • /
    • pp.550-558
    • /
    • 2014
  • This study was conducted to investigate the distribution and the population dynamics of Hipparchia autonoe by using a line transect and Mark-Release-Recapture (MRR) at the Mt. Halla in Jeju Island. The results showed that H. autonoe was found from 1,500 m above the sea level. Total 1,493 H. autonoe with 978 males and 515 females were captured and released in the MRR study site. Among them, 518 individuals including 284 males and 234 females were recaptured. The average survival time was 2.31 days with 2.14 days for males and 3.47 days for females, indicating longer survival time in case of females than males. The daily population size of males estimated in the MRR study site was maintained about 1,000 individuals in July and gradually decreased less than 200 in August. The number of females showed peak at 335 individuals on July 24, and gradually decreased less than 120 in August. Thus, female population was 1/3 of males. The average travel distance of male and female H. autonoe were $116.8{\pm}191.9m$ and $118.4{\pm}161.5m$, respectively, indicating almost same between sexes. H. autonoe in the Mt. Halla formed single population group in the wide meadow around the Baekrokdam Lake. The highest population density of H. autonoe was occurred in the restored area from damages, where host plants such as the sheep's fescue or the food plant are abundant by artificial restoration efforts.

Advanced Hybrid EER Transmitter for WCDMA Application Using Efficiency Optimized Power Amplifier and Modified Bias Modulator (효율이 특화된 전력 증폭기와 개선된 바이어스 모듈레이터로 구성되는 진보된 WCDMA용 하이브리드 포락선 제거 및 복원 전력 송신기)

  • Kim, Il-Du;Woo, Young-Yun;Hong, Sung-Chul;Kim, Jang-Heon;Moon, Jung-Hwan;Jun, Myoung-Su;Kim, Jung-Joon;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.8
    • /
    • pp.880-886
    • /
    • 2007
  • We have proposed a new "hybrid" envelope elimination and restoration(EER) transmitter architecture using an efficiency optimized power amplifier(PA) and modified bias modulator. The efficiency of the PA at the average drain voltage is very important for the overall transmitter efficiency because the PA operates mostly at the average power region of the modulation signal. Accordingly, the efficiency of the PA has been optimized at the region. Besides, the bias modulator has been accompanied with the emitter follower for the minimization of memory effect. A saturation amplifier, class $F^{-1}$ is built using a 5-W PEP LDMOSFET for forward-link single-carrier wideband code-division multiple-access(WCDMA) at 1-GHz. For the interlock experiment, the bias modulator has been built with the efficiency of 64.16% and peak output voltage of 31.8 V. The transmitter with the proposed PA and bias modulator has been achieved an efficiency of 44.19%, an improvement of 8.11%. Besides, the output power is enhanced to 32.33 dBm due to the class F operation and the PAE is 38.28% with ACLRs of -35.9 dBc at 5-MHz offset. These results show that the proposed architecture is a very good candidate for the linear and efficient high power transmitter.

A study on the Hematologic Effects of Radioactive Iodine($^{131}I$) Therapy on Various Thyroid Diseases (방사성동위원소옥소(放射性同位元素沃素)($^{131}I$)의 치료량(治療量)이 갑상선종환자(甲狀腺腫患者)의 혈액상(血液像)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kim, Myung-Jae;Kim, Noe-Kyeong;Lee, Jung-Sang;Choi, Keun-Chul;Lee, Ryong-Woo;Kim, Kee-Won;Kang, Shin-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.51-58
    • /
    • 1969
  • To clarify the hematologic effects of the radioiodine ($^{131}I$) in therapeutic doses ($5{\sim}10$ mCi) on the various thyroid patients, authors studied the peripheral blood pictures of 396 goitrous patients before and after radioiodine ($^{131}I$) administrations in the Isotope Clinic of Seoul National University Hospital. Among these 396 cases of goiters, we gave 5 to 10 mCi of radioiodine ($^{131}I$) with single or fractionated administrations. The blood pictures of peripheral blood were repeated after 3 months in 40 cases of 65 cases who had been treated with $^{131}I$. The blood pictures of non-treated thyroid patients were compared with that of normal Korean values to clarify any difference between normal and goiter. The blood pictures of hyperthyroid patients treated with $^{131}I$ therapy were compared with the blood pictures of non-treated thyroid patients. The results were as following: 1) The incidence according to type: Toxic diffuse goiter: 35.4% Nontoxic nodular goiter: 29.7% Euthyroid: 13.8% Nontoxic diffuse goiter: 12.6% Hypothyroidism: 4.3% Thyroiditis($\bar{s}$ subacute form): 1.8% Toxic nodular goiter: 1.4% Malignancy: 1.0% 2) Age incidence: The range of distribution was 11 to 71 years. The peak incidence was found in the 4th decade of life. $80.6{\sim}82.6%$ of those 396 cases were found among the 3rd, 4th and the 5th decades of life. 3) Sex incidence: Sex ratio of male:female was 1:7.8. 4) The most outstanding findings in peripheral blood before treatment were decreased erythrocyte count and hemoglobin value in all types of thyroid diseases, especially in. the cases of hypothyroidism and thyroiditis. Hook worm-infested patients showed no significant difference in erythrocytes and hemoglobin values from those of other hook worm free patients. 5) Total leukocytes count was within normal range. Differential count of W.B.C. showed increased percentile of lymphocyte in diffuse toxic goiter and thyroiditis. 6) 39 cases of diffuse goiter treated with $^{131}I$ toxic showed amelioration in the anemia and restoration to normal range of lymphocyte count in association with increased percentile of neutrophiles 3 months after administration, except a case of toxic nodular goiter. One can observe anemia in slight degree, and increased lymphocytes count in hypothyroidism. Therapeutic dose of radioiodine ($^{131}I$) does not result any residual effect on the hematopoietic function. Radioiodine ($^{131}I$) therapy resulted in improvement of thyroid function in association of amelioration of pevious abnormal blood pictures. 7) Authors did not observe any myxedema resulted from radioiodine therapy during the 3 months period in this study.

  • PDF

MICROLEAKAGE OF MICROFILL AND FLOWABLE COMPOSITE RESINS IN CLASS V CAVITY AFTER LOAD CYCLING (Flowable 및 microfill 복합레진으로 충전된 제 5급와동에서 load cycling 전,후의 미세변연누출 비교)

  • Kang, Suk-Ho;Kim, Oh-Young;Oh, Myung-Hwan;Cho, Byeong-Hoon;Um, Chung-Moon;Kwon, Hyuk-Choon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.142-149
    • /
    • 2002
  • Low-viscosity composite resins may produce better sealed margins than stiffer compositions (KempScholte and Davidson, 1988: Crim, 1989). Plowable composites have been recommended for use in Class V cavities but it is also controversial because of its high rates of shrinkage. On the other hand, in the study comparing elastic moduli and leakage, the microfill had the least leakage (Rundle et at. 1997) Furthermore, in the 1996 survey of the Reality Editorial Team, microfills were the clear choice for abfraction lesions. The purpose of this study was to evaluate the microleakage of 6 compostite resins (2 hybrids, 2 microfills, and 2 flowable composites) with and without load cycling. Notch-shaped Class V cavities were prepared on buccal surface of 180 extracted human upper premolars on cementum margin. The teeth were randomly divided into non-load cycling group (group 1) and load cycling group (group 2) of 90 teeth each. The experimental teeth of each group were randomly divided into 6 subgroups of 15 samples. All preparations were etched, and Single bond was applied. Preparations were restored with the following materials (n=15) : hybrid composite resin [Z250(3M Dental Products Inc. St. Paul, USA), Denfil(Vericom, Ahnyang, Korea)], microfill [Heliomolar RO(Vivadent, Schaan, Liechtenstein), Micronew(Bisco Inc. Schaumburg, IL, USA)], and flowable composite[AeliteFlo(Bisco Inc. Schaumburg, IL, USA), Revolution(Kerr Corp. Orange, CA, USA)]. Teeth of group 2 were subjected to occlusal load (100N for 50,000 cycles) using chewing simulator(MTS 858 Mini Bionix II system, MTS Systems Corp. Minn. USA). All samples were coated with nail polish 1mm short of the restoration, placed in 2% methylene blue for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a sclale of 0 (no leakage) to 3 (3/3 of wall). Results were statistically analyzed by Kruscal-Wallis One way analysis, Mann-Whitney U-test, and Student-Newmann-Keuls method. (p = 0.05) Results : 1. There was significantly less microleage in enamel margins than dentinal margins of all groups (p<0.05) 2. There was no significant between six composite resin in enamel margin of group 1. 3. In dentin margin of group 1, flowable composite had more microleakage than others but not of significant differences. 4. there was no significant difference between six composite resin in enamel margin of group 2. 5. In dentin margin of group 2, the microleakage were R>A =H=M>D>Z. But there was no significant differences. 6. In enamel margins, load cycling did not affect the marginal microleakage in significant degree. 7. In enamel margins, load cycling did affect the marginal microleakage only in Revolution. (p<0.05).

LONGEVITY AND FAILURE ANALYSIS OF FIXED RESTORATIONS SERVICED IN KOREA (국내에서 제작된 고정성 보철물의 수명과 실패 요인 및 양상)

  • Shin Woo-Jin;Jeon Young-Sik;Lee Keun-Woo;Lee Ho-Yong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.158-175
    • /
    • 2005
  • Statement of problem. Every effort has been continually made to obtain objectivity in measuring the longevity of fixed restorations, such as by establishing unified judgement standard for deciding success and adopting statistical method that analyzes the data of successful and failed cases at the same time. In Korea, however desired level of development has not to be made in this field yet. Purpose. This study, adopting California Dental Association (CDA) quality evaluation system, established objective standard for deciding success, and inferred the longevity of fixed restorations and their failure analysis through adopting Kaplan-Meier survival analysis. Material and method. In order to assess the longevity of flxed restorations serviced in Korea and causes of failure, a total of 1109 individuals (aged 15-74, 716 women and 393 men loaded with 2551 unit fixed restorations, and 1934 abutments) who lived in Kyung-In Province were examined and the findings were as follows : Results. 1. Length of service of fixed restorations serviced in Korea was 6.86$\pm$0.15 yr (mean), 5.5 yr (median), and the rate of success was 65.82% in 5 year survival, and 21.15% in 10 year survival. 2. When there was patient's need for replacing old prosthetics, longevity of fixed restorations was 7.51$\pm$0.27 yr (mean), 7 yr (median), and the rate of success was 61.08% in 5 year survival, and 17.57% in 10 year survival. 3. Longevity of fixed restorations was longest in the over-sixty age group(9.21$\pm$0.66) and that of the teen age group(3.39$\pm$0.28) was shortest (p<0.05). 4. Longevity of fixed restorations of women (7.38$\pm$0.18 years) was longer than that of men (6.00$\pm$0.26) (p<0.05). 5. As for the provider factor (such as unlicensed performers, university hospitals, and private clinic), there was no statistically significant difference in longevity of fixed restorations. 6. Defective margin (34.78%). periodontal disease (12.15%), periapical involvement (11.73%), was the most frequent causes of failure and poor esthetics group showed the longest life above all (p<0.05). Actual frequent causes of failure after removing old prosthetics were defective margin, periapical involvement, periodontal disease and uncemented restoration. In 75.67% of the cases, abutment state after removing old prosthetics was good enough for loading another prosthetics. 7. There was found to have statistically significant influence between longevity of single crown (6.35$\pm$0.20 yr) and that of 3 unit fixed restorations (7.60$\pm$0.30 y) (p<0.05). In each case the most frequent cause of failure was defective margin. 8. The number of cantilever pontic, pontic/abutment ratio, oral hygiene status were found to have no statistically significant influence on longevity of fixed restorations in all groups (p>0.05). 9. Longevity of fixed restorations made of non precious metal was longest (9.60$\pm$0.40 yr) semi precious and precious trailing behind(p<0.05). 10. Group function group (37.04%) and partial group function group (44.62%) were predominant in frequency but showed no correlation between them and among different types of occlusal plane and different types of occlusal surface (p>0.05). 11. Longevity of fixed restorations was longest in the centric interference group(9.35$\pm$0.62) (p<0.05) among different types of occlusal interference. Conclusion. We found that longevity of fixed restorations serviced in Korea is affected by age, gender and type of material, and that most frequent cause of failure is defective margin. In order to assess the accurate longevity of axed restorations, unified research design. overcoming inter-observer difference and establishing the objective research items are needed. Furthermore, it is thought that prospective approach through thorough study and regular follow-ups is needed just from the start of research. Nationwide detailed studies on length of service of fixed restorations manufactured in Korea are hoped to be conducted hereafter.

2-D/3-D Seismic Data Acquisition and Quality Control for Gas Hydrate Exploration in the Ulleung Basin (울릉분지 가스하이드레이트 2/3차원 탄성파 탐사자료 취득 및 품질관리)

  • Koo, Nam-Hyung;Kim, Won-Sik;Kim, Byoung-Yeop;Cheong, Snons;Kim, Young-Jun;Yoo, Dong-Geun;Lee, Ho-Young;Park, Keun-Pil
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.127-136
    • /
    • 2008
  • To identify the potential area of gas hydrate in the Ulleung Basin, 2-D and 3-D seismic surveys using R/V Tamhae II were conducted in 2005 and 2006. Seismic survey equipment consisted of navigation system, recording system, streamer cable and air-gun source. For reliable velocity analysis in a deep sea area where water depths are mostly greater than 1,000 m and the target depth is up to about 500 msec interval below the seafloor, 3-km-long streamer and 1,035 $in^3$ tuned air-gun array were used. During the survey, a suite of quality control operations including source signature analysis, 2-D brute stack, RMS noise analysis and FK analysis were performed. The source signature was calculated to verify its conformity to quality specification and the gun dropout test was carried out to examine signature changes due to a single air gun's failure. From the online quality analysis, we could conclude that the overall data quality was very good even though some seismic data were affected by swell noise, parity error, spike noise and current rip noise. Especially, by checking the result of data quality enhancement using FK filtering and missing trace restoration technique for the 3-D seismic data inevitably contaminated with current rip noises, the acquired data were accepted and the field survey could be conducted continuously. Even in survey areas where the acquired data would be unsuitable for quality specification, the marine seismic survey efficiency could be improved by showing the possibility of noise suppression through onboard data processing.

RESISTANCE TO DEMINERALIZATION OF ENAMEL OF PRIMARY TEETH ACCORDING TO RESTORATIONS: IN VITRO STUDY USING QLF (유치 수복물에 따른 주변 법랑질의 탈회 저항성: QLF를 이용한 연구)

  • Kwon, Hae-Sook;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.1
    • /
    • pp.44-52
    • /
    • 2010
  • The objective of this in vitro study was to detect and monitor demineralization and remineralization of primary teeth according to restorative materials using quantitative light-induced fluorescence (QLF). A single bur hole was drilled on the each sound forty eight primary anterior teeth, and the specimens were divided into three groups. The cavity was restored with $Filtek^{TM}$ Z250(Group 1), F2000(Group 2), $Ketac^{TM}$ N100(Group 3) following the manufacturer's instructions. The teeth were subjected to the demineralizing buffer for 3 days, and then subjected to a remineralizing buffer for 14 days. The change of mineral loss(${\Delta}Q$) according to the stages was evaluated by QLF and the following results were obtained: 1. When demineralization was done, ${\Delta}Q$ was increased as follows. : Group 1 ($-110.79\;{\pm}\;27.77$) < Group 2 ($-104.84\;{\pm}\;28.95$) < Group 3 ($-90.16\;{\pm}\;21.87$) : Resistance to demineralization was statistically significant in Group 3. 2. There was a statistically significant increase in ${\Delta}Q$ of all groups since 1st day of remineralization 3. The rate of remineralization, ${\Delta}$(${\Delta}Q$)/day, showed significant high value in each group on the 1st day then decreased rapidly. 4. There was no statistically significant difference in the degree of remineralization among restorative materials.

CONFOCAL LASER SCANNING MICROSCOPIC MORPHOLOGY OF DENTIN-RESIN INTERFACE AND ITS RELATIONSHIP WITH SHEAR BOND STRENGTH (상아질-레진 계면의 공초점 현미경적 형태 및 전단결합강도와의 관계)

  • Choi, Nak-Won;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.310-321
    • /
    • 1999
  • In this in vitro study, confocal laser scanning microscopic morphology of dentin-resin interface and its relationship to shear bond strength were investigated after the exposed dentin surfaces were treated with 3 different kinds of dentin adhesive systems[three-step; Scotchbond Multi-Purpose Plus(SMPP), self-priming bonding resin; Single Bond(SB), self-etching primer; Clearfil Liner Bond 2(LB2)]. 52 extracted human molar teeth without caries and/or restorations. The experimental teeth were randomly divided into three groups of seventeen teeth each. In five teeth of each group, class V cavities(depth: 1.5mm) with 900 cavosurface angles were prepared at the cementoenamel junction on buccal and lingual surfaces. Bonding resins of each dentin adhesive system were mixed with rhodamine B. Primer of SMPP was mixed with fluorescein. In group 1. the exposed dentin was conditioned with etchant, applied with above primer and bonding resin of SMPP. In group 2, with etchant and self-priming bonding agent of SB. In group 3, with self-etching primer and bonding agent of LB2. After treatment with dentin adhesive systems, composite resin were applied and photocured. The experimental teeth were cut longitudinally through the center line of restoration and grounded so that about $90{\mu}m$-thick wafers of buccolingually orientated dentin were obtained. And, $70{\sim}80{\mu}m$-thick wafers sectioned horizontally, thus presenting a dentinal tubules at 900 to the cut surface of a remaining tooth, were obtained. Primer of SMPP mixed with rhodamine B was applied to these wafers. Confocal laser scanning microscopic investigations of these wafers were done within of 24 hours after treatment. To measure shear bond strength, the remaining twelve teeth of each group were grounded horizontally below the dentinoenamel junction, so that no enamel remained. After applying dentin adhesive systems on the dentin surface, composite was applied in the shape of cylinder. The cylinder was 5mm in diameter, and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. It was concluded as follows ; 1. Hybrid layer of SMPP(mean: $4.56{\mu}m$) was thicker than that of any other groups. This value was not statistically significant thicker than that of SB(mean: $3.41{\mu}m$, p>0.05), and significant thicker than that of LB2(mean: $1.56{\mu}m$, p<0.05). There was a statistical difference between SB and LB2(p<0.05). 2. Although there were variations in the length of resin tag even in a sample, and in a group, most samples in SMPP and SB showed resin tags extending above $20{\mu}m$. But samples in LB2 showed resin tags of $10{\mu}m$ at best. 3. Besides primer's infiltration into demineralized peritubular dentin and dentinal tubules, fluorophore of primer was detected in the lateral branches of dentinal tubules. 4. All groups demonstrated statistically significant differences from one another(p<0.05), with shear bond strengths given in descending order as follows: SMPP(18.3MPa), SB(16.0MPa) and LB2(12.4MPa). 5. LB2 having thinnest hybrid layer($1.56{\mu}m$) showed the lowest shear bond strength(12.4MPa).

  • PDF

Experiences with Emergency Percutaneous Cardiopulmonary Support in In-hospital Cardiac Arrest or Cardiogenic Shock due to the Ischemic Heart Disease (허혈성 심질환으로 인해 병원 내에서 발생한 심정지 혹은 심정지 혹은 심인성 쇼크에 있어서의 경피적 심폐 보조장치의 치료 경험)

  • Rhee Il;Kwon Sung-Uk;Cho Sung Woo;Gwon Hyeon-Cheol;Lee Young Tak;Park Pyo Won;Park Kay-Hyun;Lee Sang Hoon;Sung Kiick
    • Journal of Chest Surgery
    • /
    • v.39 no.3 s.260
    • /
    • pp.201-207
    • /
    • 2006
  • Background: Percutaneous cardiopulmonary support (PCPS) provides passive support of gas exchange and perfusion, allowing the use of other methods of care for organ recovery, and saves lives of patients with severe cardiopulmonary failure in a wide variety of clinical settings with a minimal risk of bleeding and need for chest re~ exploration. We summarized a single center's experiences with PCPS in patients with cardiogenic shock or cardiac arrest due to the ischemic heart disease. Material and Method: Among the 20 consecutive patients with cardiogenic shock or cardiac arrest from May 1999 to June 2005, Biopump (Medtronic, Inc, Minneapolis, MN) was used in 7 patients and the self-priming, heparin-coated circuit of EBS (Terumo, Japan) was applied to remaining 13 patients. Most of cannulations were performed percutaneously via femoral arteries and veins. The long venous cannulas of DLP (Medtronic inc. Minneapolis, MN) or the RMI (Edwards's lifescience LLC, Irvine, CA) were used with the arterial cannulae from 17 Fr to 21 Fr and the venous cannula from 21 Fr to 28 Fr. Result: The 20 consecutive patients who were severely compromised and received PCPS for the purpose of resuscitation were comprised of 13 cardiac arrests and 7 cardiogenic shocks in which by-pass surgery was performed in 11 patients and 9 ongoing PCls under the cardiopulmonary support. The mean support time on the PCPS was 38$\pm$42 hours. Of the 20 patients implanted with PCPS, 11 patients ($55\%$) have had the PCPS removed successfully; overall, 8 of these patients ($40\%$) were discharged from the hospital in an average surviving time for 27$\pm$17 days after removing the PCPS and survived well with 31$\pm$30 months of follow-up after the procedure. Conclusion: The use of PCPS appears to provide the hemodynamic restoration, allowing the survival of patients in cardiac arrest or cardiogenic shock who would otherwise not survive, and patients receiving PCPS had a relatively long-term survival.

In vitro Multiplication through Single-Node Culture of Sea-Milkwort (Glaux maritima L.) (갯봄맞이(Glaux maritima L.) 실생의 단마디배양을 통한 기내증식)

  • Bae, Su-Ji;Kang, Beum-Chang;Jeong, Mihye;Kim, Soochong;Kim, Chang Kil;Han, Jeung-Sul
    • Horticultural Science & Technology
    • /
    • v.34 no.3
    • /
    • pp.461-471
    • /
    • 2016
  • This study was conducted to establish an in vitro propagation system for sea-milkwort (Glaux maritima L.), which is an endangered coastal plant species with high horticultural value. Two phenotypes, 'Red type (RT)' and 'Pistachio type (PT)' based on the colors of stem and flower, were obtained from a personal horticulturist in 2009 and used for this study as plant materials. The stock plants showed typical morphologies in flower, capsule, and seed appearances as previously reported. Low temperature treatment at $4^{\circ}C$ for four or more weeks after in vitro sowing maximized seed germination percentage, indicating that imbibition of seed and subsequent low temperature treatment are crucial for its germination. The in vitro seedlings had phenotypic variation, falling into 'RT' and 'PT' classes like the stock plants. Although slight differences depending on genotype and medium were recognized, the fourth or fifth nodes detached from the in vitro seedlings revealed the best multiplication efficacy when estimated on the basis of total number of nodes of newly developed axillary shoots. In addition, the nodes from 'RT' and 'PT' regenerated the most shoots on medium supplemented with $0.5mg{\cdot}L^{-1}$ BA alone and $0.5mg{\cdot}L^{-1}$ BA plus $0.5mg{\cdot}L^{-1}$ IAA, respectively. The node culture-derived plantlets were well acclimatized in a culture room ex vitro and completed the pseudo-annual life cycle coincident with that in the natural salt march habitat with the current cultivation method of applying fresh water-irrigation under an inland environment. This work represents the first report of in vitro propagation of sea-milkwort. Thus, our study will contribute to exo-habitat conservation and natural habitat restoration of this endangered species in addition to development of a horticultural product.