• Title/Summary/Keyword: Single photon emission tomography (SPECT)

Search Result 138, Processing Time 0.022 seconds

Significant Reperfusion on $^{99m}Tc-HMPAO$ SPECT in a Case of Subacute MCA Infarction (한의학적 치료로 $^{99m}Tc-HMPAO$ SPECT상 현저한 재관류를 보인 아급성기 중대뇌동맥경색 환자 1례)

  • Park, Jung-Mi;Jung, Woo-Sang;Seo, Al-An
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.3
    • /
    • pp.437-442
    • /
    • 2001
  • For ischemic cerebrovascular disease, it is well known that early luxury perfusion is related to a good clinical outcome and single photon emission computed tomography(SPECT) has the potential for providing useful information about regional cerebral blood flow. We report one case of Rt. MCA infarction mainly treated by oriental medicine and revealed luxury perfusion without thrombolysis. In acute stage, neurological deficits of the patient were very severe. 99mTc-HMPAO SPECT images obtained 10days after the attack showed large perfusion defect in the Rt. MCA territory. We followed up 99mTc-HMPAO SPECT 40days after the ictus. Despite of the poor early perfusion, we found considerably improved perfusion and neurological improvement.

  • PDF

Effect of Radioisotope Position on Performance of Industrial SPECT (방사성동위원소 위치에 따른 산업용 SPECT 성능에 미치는 영향)

  • Moon, Jinho;Kim, Jongbum;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.245-249
    • /
    • 2012
  • Demand of fluid flow visualization has increased in industrial processes, because medical imaging technology is highly developed. As a part of the industrial process imaging technology, industrial single photon emission computed tomography (SPECT) system was developed to measure the cross-sectional distribution of the process fluid. The SPECT consists of 36 NaI (Tl) detectors with the hexagonal configuration. Reconstructed images were acquired for various positions of radioactive source to estimate SPECT device performance. To evaluate the reliability of the experimental results, the Monte Carlo simulation results are compared with experimental results. In general, the experimental and simulation results were consistent. However, as the source position was getting far from the center of the reactor, the accuracy of reconstructed images was compromised. It seems to be due to the inconsistent spatial resolution of the collimators according to the source position.

Tc-99m DMSA SPECT for Follow-Up of Non-Operative Treatments in Renal Injuries: A Prospective Single-Center Study

  • Sang-Geon Cho;Ki Seong Park;Jahae Kim;Jang Bae Moon;Ho-Chun Song;Taek Won Kang;Seong Hyeon Yu
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.1017-1027
    • /
    • 2023
  • Objective: The assessment of cortical integrity following renal injuries with planar Tc-99m dimercaptosuccinic acid (DMSA) scintigraphy depends on measuring relatively decreased cortical uptake (i.e., split renal function [SRF]). We analyzed the additive values of the volumetric and quantitative analyses of the residual cortical integrity using single-photon emission computed tomography (SPECT) compared to the planar scintigraphy. Materials and Methods: This prospective study included 47 patients (male:female, 32:15; age, 47 ± 22 years) who had non-operatively managed renal injuries and underwent DMSA planar and SPECT imaging 3-6 months after the index injury. In addition to planar SRF, SPECT SRF, cortical volume, and absolute cortical uptake were measured for the injured kidney and both kidneys together. The correlations of planar SRF with SPECT SRF and those of SRF with volumetric/quantitative parameters obtained with SPECT were analyzed. The association of SPECT parameters with renal function, grades of renal injuries, and the risk of renal failure was also analyzed. Results: SPECT SRF was significantly lower than planar SRF, with particularly higher biases in severe renal injuries. Planar and SPECT SRF (dichotomized with a cutoff of 45%) showed 19%-36% of discrepancies with volumetric and quantitative DMSA indices (when dichotomized as either high or low). Absolute cortical uptake of the injured kidney best correlated with glomerular filtration rate (GFR) at follow-up (ρ = 0.687, P < 0.001) with significant stepwise decreases by GFR strata (90 and 60 mL/min/1.73 m2). Total renal cortical uptake was significantly lower in patients with moderate-to-high risk of renal failure than those with low risk. However, SRF did not reflect GFR decrease below 60 mL/min/1.73 m2 or the risk of renal failure, regardless of planar or SPECT (count- or volume-based SRF) imaging. Conclusion: Quantitative measurements of renal cortical integrity assessed with DMSA SPECT can provide more clinically relevant and comprehensive information than planar imaging or SRF alone.

The Influence of Collimators on SPECT COR Measurements (SPECT 회전중심 측정에 있어서 콜리메타의 영향)

  • Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.19 no.1
    • /
    • pp.89-94
    • /
    • 1996
  • Misalignment between the electronic and mechanical axes of rotation will result in artifact generation and image degradation during single photon emission computed tomography(SPECT) reconstruction. Acceptance and quality control testing procedures have not emphasized the variability in center of rotation(COR) measurements caused by collimators and the need to verify uniformity across the full collimator field of view (FOV). Variation from the mean COR across the FOV was tested in four different collimators using multiple point source acquisitions. The mean COR was different for each collimator and one of the four had a > 0.5 pixel difference from the mean COR on some area of the FOV, This variation makes this collimator unacceptable for SPECT acquisition. Thus, initial acceptance testing of SPECT collimators should verify a uniform COR across the full FOV and collimators with a variability from the mean COR > 0.5 pixels should be rejected.

  • PDF

The changes of cerebral blood flow by brain imaging algorithm in the Normal Brains : Analysis by Statistical Parametric Mapping (정상 뇌혈류 영상에서 재구성 알고리즘 적용에 따른 섭취율 차이 : 통계적 파라미터 지도를 사용한 분석)

  • Lee, Hyo-Yeong;Kim, Yun-Jin;Sin, Sung-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5311-5316
    • /
    • 2012
  • Single Photon Emission Computed tomography(SPECT) was performed on 13 healthy adults (average age: 39) to investigate the changes of cerebral blood flow according to brain imaging analysis algorithm. The acquired images were filtered and reconstructed through Filtered Back Projection (FBP) and Ordered Subset Expectation Maximization (OSEM). The brain distribution data of radiopharmaceuticals were compared using Statistical Parametric Mapping (SPM), and the changes of blood flow was expressed in Cluster. As a result, uptake rate was increased in Sub-gyral, Sub-Lobar, Extra-Nuclear, Limbic lobe and Cingulate Gyrus, while uptake rate was decreased in Middle frontal gyrus, Inferior Frontal Gyrus and Precentral Gyrus. The discriminable SPM was shown according to cerebral blood flows in Cluster by the reconstruction algorithm.

Effect of Particulate Matter on Human Health, Prevention, and Imaging Using PET or SPECT

  • Zaheer, Javeria;Jeon, Jongho;Lee, Seung-Bok;Kim, Jin Su
    • Progress in Medical Physics
    • /
    • v.29 no.3
    • /
    • pp.81-91
    • /
    • 2018
  • Particulate matter (PM) in dust causes serious pathological conditions, and it has been considered a critical health issue for many years. Respiratory disorders such as bronchitis, asthma, and chronic inflammation, are the most common illnesses due to PM that appears as dust. There is evidence that cardiovascular and neurological abnormalities are caused by PM. Although an extensive amount of work has been conducted on this topic, including studies on the nature of the particles, particle size measurements, particle distribution upon inhalation, the health effects of fine particles, disease prevention, diagnosis, and treatment, to this date, there is still a considerable lack of knowledge in these areas. Therefore, the identification of the key components that cause diseases owing to PM, and the specific diagnoses of the diseases, is important. This review will explore the current literature on the origin and nature of PM and their effects on human health. In addition, it will also highlight the approaches that have been adopted in order to diagnose the effects of PM using positron emission tomography (PET) or single-photon emission computerized tomography (SPECT).

Clinical Application of Cardiac Hybrid Imaging in Coronary Artery Disease (관상동맥질환에서 심장 하이브리드 영상의 임상적 이용)

  • Gho, Ihn-Ho;Kong, Eun-Jung
    • Journal of Yeungnam Medical Science
    • /
    • v.26 no.1
    • /
    • pp.15-23
    • /
    • 2009
  • Constant technological developments in coronary artery disease have contributed to the assessment of both the presence of coronary stenosis and its hemodynamic consequences. Hence, noninvasive imaging helps guide therapeutic decisions by providing complementary information on coronary morphology and on myocardial perfusion and metabolism. This can he done using single photon emission computed tomography (SPECT) or positron emission tomography (PET) and multidetector CT (MDCT). Advances in image-processing software and the advent of SPECT/CT and PET/CT have paved the way for the combination of image datasets from different modalities, giving rise to hybrid imaging. Three dimensional cardiac hybrid imaging helped to confirm hemodynamic significance in many lesions, add new lesions such as left main coronay artery disease, exclude equivocal defects, correct the corresponding arteries to their allocated defects and identify culprit segment. Cardiac hybrid imaging avoids the mental integration of functional and morphologic images and facilitates a comprehensive interpretation of coronaty lesions and their pathophysiologic adequacy by three dimensional display of fused images, and allows the best evaluation of myocardial territories and the coronary-artery branches that serve each territory. This integration of functional and morphological information were feasible to intuitively convincing and might facilitate development of a comprehensive non-invasive assessment of coronary artery disease.

  • PDF

Pulling Bowstring of Gated Myocardial SPECT (게이트 심근 SPECT : 도약을 위한 준비)

  • Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.433-435
    • /
    • 1998
  • Recent progress of technology permits us to assess ventricular function and wall motion as well as myocardial perfusion using electrocardiographic gated myocardial perfusion single photon emission computed tomography (GM-SPECT). It is interesting that echocardiography and magnetic resonance imaging are moving in the same direction with the use of contrast medium to assess myocardial perfusion. A valid fundamental basis for a new technology is essential for a successful competition. Lee et al. report in this issue the reproducibility of serial measurement of left ventricular function including systolic wall thickening using a novel statistical method. It has important implications such as nitroglycerin or dobutamine application during GM-SPECT. The field of nuclear cardiology must continue to strive toward more sophisticated but straightforward evaluation of cardiac diseases.

  • PDF

Synthetic Approach to 99mTc-labeled SPECT Radiotracers with Multi-nitroimidazoles for Hypoxia

  • Anh Thu Nguyen;Hee-Kwon Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Hypoxia, defined as the deficiency of oxygen, is a significant hallmark of cancers presenting in the majority of solid tumors. Detection of tumor hypoxia is essential in cancer diagnosis to prevent cancer progression, metastasis, and resistance to cancer therapies in clinical practices. Single-photon emission computed tomography (SPECT) is one of the methods studied and applied for hypoxia detection with the use of radiolabeled imaging agents in which 99mTc is the common radioisotope used for radiolabeling. Nitroimidazoles are the hypoxia-targeting moieties presenting in numerous 99mTc-radiolabeled imaging agents due to their bio-reducible ability in hypoxic environments. Recently, in addition to 99mTc-labeled radiopharmaceuticals containing one nitroimidazole unit, there has been considerable attention given to 99mTc-radiopharmaceuticals bearing two or more nitroimidazole units. This review summarizes the synthesis of hypoxia-targeting chelators and radiolabeling processes to produce these 99mTc-radiopharmaceuticals for SPECT imaging.

A Study on Virtual Reality Management of 3D Image Information using High-Speed Information Network (초고속 정보통신망을 통한 3차원 영상 정보의 가상현실 관리에 관한 연구)

  • Kim, Jin-Ho;Kim, Jee-In;Chang, Chun-Hyon;Song, Sang-Hoon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.12
    • /
    • pp.3275-3284
    • /
    • 1998
  • In this paper, we deseribe a Medical Image Information System. Our system stores and manages 5 dimensional medical image data and provides the 3 dimensional medical data via the Internet. The Internet standard VR format. VRML(Virtual Reality Modeling Language) is used to represent the 3I) medical image data. The 3D images are reconstructed from medical image data which are enerated by medical imaging systems such ans CT(Computerized Tomography). MRI(Magnetic Resonance Imaging). PET(Positron Emission Tomograph), SPECT(Single Photon Emission Compated Tomography). We implemented the medical image information system shich rses a surface-based rendering method for the econstruction of 3D images from 2D medical image data. In order to reduce the size of image files to be transfered via the Internet. The system can reduce more than 50% for the triangles which represent the surfaces of the generated 3D medical images. When we compress the 3D image file, the size of the file can be redued more than 80%. The users can promptly retrieve 3D medical image data through the Internet and view the 3D medical images without a graphical acceleration card, because the images are represented in VRML. The image data are generated by various types of medical imaging systems such as CT, MRI, PET, and SPECT. Our system can display those different types of medical images in the 2D and the 3D formats. The patient information and the diagnostic information are also provided by the system. The system can be used to implement the "Tele medicaine" systems.

  • PDF