• 제목/요약/키워드: Single particle size

검색결과 359건 처리시간 0.029초

Ignition Behavior of Single Coal Particles From Different Coal Ranks at High Heating Rate Condition

  • Lee, Dongfang;Kim, Ryang Gyoon;Jeon, Chung-Hwan
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.111-114
    • /
    • 2012
  • The ignition behavior of single coal particles of five kindes of coal with different ranks (low volatile bituminous, low volatile sub-bituminous, high volatile bituminous, lignite) with particle size of $150-200{\mu}m$ was investigated at high heating rate condition. Particles were injected into a laminar flow reactor and the ignition behavior was observed with high speed cinematography. Sub-bituminous were observed to ignite homogeneously; however, low volatile bituminous coal and lignite undergo fragmentation prior to igntion. The observation was analyzed with previous work.

  • PDF

Characterization of Individual Atmospheric Aerosols Using Quantitative Energy Dispersive-Electron Probe X-ray Microanalysis: A Review

  • Kim, Hye-Kyeong;Ro, Chul-Un
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권3호
    • /
    • pp.115-140
    • /
    • 2010
  • Great concerns about atmospheric aerosols are attributed to their multiple roles to atmospheric processes. For example, atmospheric aerosols influence global climate, directly by scattering or absorbing solar radiations and indirectly by serving as cloud condensation nuclei. They also have a significant impact on human health and visibility. Many of these effects depend on the size and composition of atmospheric aerosols, and thus detailed information on the physicochemical properties and the distribution of airborne particles is critical to accurately predict their impact on the Earth's climate as well as human health. A single particle analysis technique, named low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA) that can determine the concentration of low-Z elements such as carbon, nitrogen and oxygen in a microscopic volume has been developed. The capability of quantitative analysis of low-Z elements in individual particle allows the characterization of especially important atmospheric particles such as sulfates, nitrates, ammonium, and carbonaceous particles. Furthermore, the diversity and the complicated heterogeneity of atmospheric particles in chemical compositions can be investigated in detail. In this review, the development and methodology of low-Z particle EPMA for the analysis of atmospheric aerosols are introduced. Also, its typical applications for the characterization of various atmospheric particles, i.e., on the chemical compositions, morphologies, the size segregated distributions, and the origins of Asian dust, urban aerosols, indoor aerosols in underground subway station, and Arctic aerosols, are illustrated.

쌀가루의 수분함량과 입자크기에 따른 Extrudate 의 물성학적 성질 (Effects of Moisture Content and Particle Size of Rice Flour on the Physical Properties of the Extrudate)

  • 류기형;이철호
    • 한국식품과학회지
    • /
    • 제20권4호
    • /
    • pp.463-469
    • /
    • 1988
  • 쌀가루의 압출성형 특성을 조사하기 위하여 원료의 수분합량과 입자크기를 달리하여 자가발열형 single screw extruder로 처리하고 이때 온도변화에 따른 extrudate의 물성학적인 성질을 비교하였다. 원료의 수분함량은 17%, 19%, 22%, 25%, 28%로 했고 입자크기는 18-60mesh와 60-120mesh의 두 범위로 했다. 내부흐름의 온도는 자동 온도기록계에 기록되게 하여 정상상태 가동이 될 때까지 경시적으로 시료를 채취하였다. 팽화율은 수분함량과 입자크기가 감소함에 따라 증가하였으며, bulk density는 팽화율과 역상관 관계를 나타내었다. Extrudate의 절단력은 수분함량이 적고 입자조기가 감소함에 따라 낮아졌으며 기공의 크기도 균일하였다. 색도는 수분함량과 입자크기가 증가함에 따라 명도는 증가하였고 황색도는 감소하였다. 겉보기 점도는 수분함량이 증가함에 따라 증가했고, 수용성 지수는 감소하였다. 원료의 수분이 감소함에 따라 일부의 전분은 호정화를 유발하는 것으로 판단되었다.

  • PDF

축류형 사이클론을 이용한 공기역학경과 광학직경 상관관계 분석에 관한 연구 (A Study on Correlation Analysis between Aerodynamic Diameter and Optical Diameter Using Axial Flow Cyclone)

  • 김은정;박경려;허지은;조철희;조윤행
    • 한국입자에어로졸학회지
    • /
    • 제19권4호
    • /
    • pp.155-164
    • /
    • 2023
  • APS (Aerodynamic Particle Sizer) and OPC (Optical Particle Counter) have been widely used to real-time measurement of indoor and outdoor aerosols. The APS measures the size distribution based on an aerodynamic diameter, while the OPC uses optical diameter to measure the size distribution of aerosols. Since obtaining a size distribution based on aerodynamic diameter is important to understand aerosol characteristics, lots of researcher had been developed experimental equations which can convert optical diameter into aerodynamic diameter. However, previous studies have conducted repeated experiments on particles having a single diameter. In this study, an experimental method of converting optical diameter into aerodynamic diameter through a single experiment was presented. The collection efficiencies of an axial cyclone were measured using APS and OPC at the same time, and the correlation equation between aerodynamic diameter and optical diameter was driven through a theoretical model. Using the proposed method, the size distribution of NaCl particles measured by OPC showed a high correlation with the size distribution obtained by APS (0.93 of R-squared value). In the tests conducted on ISO A1, A2, and A4 test particles, the converted OPC size distribution tended to be similar to the APS size distribution, and for each of test particles (ISO A1, A2, and A4), the R-squared values for the APS particle size distribution were 0.75, 0.86, and 0.89, respectively.

EFFECTS OF TRACE METALS ON PARTICULATE MATTER FORMATION IN A DIESEL ENGINE: METAL CONTENTS FROM FERROCENE AND LUBE OIL

  • Lee, D.G.;Miller, A.;Park, K.H.;Zachariah, M.R.
    • International Journal of Automotive Technology
    • /
    • 제7권6호
    • /
    • pp.667-673
    • /
    • 2006
  • Diesel particulate matter(DPM) often contains small amounts of metal as a minor component but this metal may contribute to adverse health effects. Knowledge of the mechanism for particle formation as well as the size preference of the trace metals is critical to understanding the potential for health concerns. To achieve this, the size and the composition of each particle should be optimally measured at the same time. Single particle mass spectrometer(SPMS) would be the best tool for this objective. In this paper, we therefore will introduce new findings about the mechanism and distribution of the trace metals in DPM, derived from a study where an SPMS was used to analyze freshly emitted DPM.

입자층(粒子層)을 이용(利用)한 열교환기(熱交換器) 개발(開發)에 관(關)한 연구(硏究)(I) - 유동층형(流動層形) 이중관식(二重管式) 열교환기(熱交換器)의 전열특성(傳熱特性)에 대한 실험적(實驗的) 연구(硏究) (대향류식(對向流式)) (Development of a Particle Bed Heat Exchanger(I) -An Experimental Study on Heat Transfer Characteristics of Fluidized Bed Heat Exchanger with Double Pipe (Counterflow))

  • 임종규;류지오;양한주;서정윤
    • 설비공학논문집
    • /
    • 제2권2호
    • /
    • pp.119-126
    • /
    • 1990
  • In this study, the overall heat transfer coefficients are calculated on fluidized bed double pipe heat exchanger and single phase double pipe heat exchanger at the same condition. The effect of the particle size, its material, fluidizing velocity and static bed height on overall heat transfer coefficient has been investigated. The main conclusions obtained from the experiment are as follows. 1. The overall heat transfer coefficient of the fluidized bed heat exchanger is higher than that of single phase forced convective heat exchanger (maximum 2.3 times) 2. The value of the overall heat transfer coefficient increase with an increase in static bed height and decrease with an increase in particle size. 3. For the same particle size, the particle of low density can obtain higher overall heat transfer coefficient than that of high density.

  • PDF

다단 임팩터(MOUDI)의 조대 입자 채취 특성 (Collection Characteristics of a MOUDI Cascade Impactor for Coarse Particles)

  • 배귀남;지준호;문길주
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.799-804
    • /
    • 1999
  • Particle collection characteristics of the MOUDI cascade impactor has been studied for coarse particles in the range of 2 to 20$mu extrm{m}$ in aerodynamic diameter. A vibrating orifice aerosol generator was empolyed to generate monodisperse test aerosols. The oleic acid and sodium chloride(NaCl) particles were used as test aerosols. Aluminum foil and Teflon filter were selected as impaction media. The sampling flow rate was changed from 25 to 35L/min. Particle collection efficiency for single stage was examined for liquid particles. The stage response was obtained experimentally for the cascade impactor composed of three stages and a backup filter. The results showed that most of particle collection efficiencies measured in this work are similar to the efficiency curves obtained by Marple et al.(1991). For particles less than cut-off size of the stage, the collection efficiencies of solid particles are similar to those of loquid particles. However, the collection efficiency of solid particles decreases with mereasing particle diameter for the particles greater than the actual cut-off size of the impactor. The particle collection efficiency increases with increasing sampling flow rate at the same particel size. However, the collection efficiency curves seem not to be greatly shifted with the flow rate. The stage responses obtained by direct measurements in this work are in good agreement with those derived from the collection efficiency curves for single stage.

  • PDF

입상여과에서 입자물질의 탈리 (Particle Detachment in Granular Media Filtration)

  • 김진근
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.673-679
    • /
    • 2004
  • Particle breakthrough can occur by either the breakoff of previously captured particles (or flocs) or the direct passage of some influent particles through the filter. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collectors. A single type of particle suspension (Min-U-Sil 5, nearly pure $SiO_2$) and three different destabilization methods (pH control, alum and polymer destabilization) were utilized. The operating conditions were similar to those of standard media filtration practice: a filtration velocity of 5 m/h. To assess the possibility of particle detachment during the normal filtration, a hydraulic shock load (20% increase of flow rate) was applied after 4 hours of normal filtration. The magnitude of particle detachment was proportional to the particle size for non-Brownian particles. At the same time, less favorable particles, i.e., particles with larger surface charge, were easily detached during the hydraulic shock load. Therefore, proper particle destabilization before filtration is crucial for maximum particle removal as well as minimum particle breakthrough.

마이크로파 플라즈마 토치를 이용한 에어로졸 입자 분석 (Aerosol Particle Analysis Using Microwave Plasma Torch)

  • 김학준;박지호
    • 대한화학회지
    • /
    • 제55권2호
    • /
    • pp.204-207
    • /
    • 2011
  • 입자의 화학적 성분을 제공하는 동시에 감도가 높고, 경제적이며, 공간을 덜 차지하는 입자 수 측정 시스템을 개 발하였다. 이 시스템은 마이크로파 플라즈마 토치를 이용하여 원자를 들뜬 상태로 만든 후 생성된 발광을 측정한다. 하나 의 입자로부터 생성된 발광의 파장으로부터 입자에 존재하는 원소를 확인할 수 있다. 발광의 세기로부터 입자의 화학적 성분뿐 아니라 입자의 크기 또한 측정할 수 있다. 장기적으로 이 시스템은 휴대가 가능하도록 만들어 현장에서 실시간으 로 대기에 존재하는 낮은 농도의 에어로졸 입자를 분석하는데 쓰일 수 있다.

Determination of the Uranium Backgrounds in Lexan Films for Single Particle Analysis using FT-TIMS technique

  • Park, Su-Jin;Park, Jong-Ho;Lee, Myung-Ho;Song, Kyu-Seok
    • Mass Spectrometry Letters
    • /
    • 제2권2호
    • /
    • pp.57-60
    • /
    • 2011
  • As background significantly affects measurement accuracy and a detection limit in determination of the trace amounts of uranium, it is necessary to determine the impurities in the Lexan detector film for single particle measurements by thermal ionization mass spectrometry coupled with fission track technique (FT-TIMS). We have prepared various micro sizes of the blank Lexan detector film using a micromanipulation technique for uranium measurements by TIMS. Few tens of fg of uranium background with no remarkable dependency on the film sizes were observed in the blank Lexan films with the sizes from $50{\times}50\;{\mu}m^2$ to $300{\times}300\;{\mu}m^2$. Based on the determination of the uranium background in the Lexan film, any background correction is necessary in the isotopic analysis of a uranium single particle with micron sizes when the particle bearing Lexan film is dissected with less than $300{\times}300\;{\mu}m^2$ size. The isotopic analysis of a uranium particle in U030 standard material using TIMS was carried out to verify the applicability of the Lexan film to the single particle analysis with high accuracy and precision.