• 제목/요약/키워드: Single and composite liner

검색결과 10건 처리시간 0.024초

Performance of Double Composite Landfill Liner considering Leakage Rate and Mass Flux

  • Nguyen, The Bao;Lee, Chul-Ho;Choi, Hang-Seok
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.295-304
    • /
    • 2010
  • Performance of a landfill liner is evaluated based on leakage rate and mass flux. In this study, the recently utilized double composite liner system, which consists of a geomembrane (GM), a geosynthetic clay liner (GCL), a GM, and a compacted clay layer (61 or 91.5 cm) is compared with other popular composite liners including the single GCL system, the Subtitle D liner system, and the Wisconsin NR500 liner system. The leakage rate through circular and long defects in the GM of the landfill liners is analyzed using numerical models. For the mass flux criterion, the analyses of inorganic contaminant transport through defects in the GM component of liner systems and diffusion of organic compounds through intact landfill liners are conducted using three- and one-dimensional numerical models, respectively. Cadmium and toluene are used in the analyses as a typical inorganic and organic substance, respectively, which will be chemical species encountered during landfill operation. The comparison shows that the double composite liner systems are superior to the other liner systems according to the performance-based evaluation.

  • PDF

매립지 차수재 두께 산정을 위한 컴퓨터 프로그램 개발 (Development of a Computer Program to Estimate Landfill Liner Thickness)

  • 도남영;이승래;정광영
    • 한국지반환경공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.13-26
    • /
    • 2005
  • 본 연구에서는 여러 연구자들에 의해 제안된 단일 점토 및 혼합 차수재를 통한 유기 및 무기 오염물질 이동에 관한 연구결과를 정리하여 보았고, 이러한 연구결과를 바탕으로 오염물질 유출 기준을 만족하는 차수재의 두께를 산정할 수 있는 차수재 설계 프로그램을 개발하였다. 본 프로그램을 이용하여 점토 차수재를 통한 $Cl^-$이온의 이동성에 바탕을 둔 매립지 두께를 산정해본 결과 비교적 합리적인 결과를 얻을 수 있었다. 따라서 본 연구에서 개발된 프로그램을 이용할 경우에는 비교적 간편한 방법으로 매립지 차수재의 예비설계를 수행할 수 있을 것으로 사료된다.

  • PDF

필라멘트 와인딩법에 의한 단일 개구부 복합재료 압력용기의 개발 (Development of Filament Wound Composite Pressure Vessels with a Single Boss)

  • 황병선;김병선;김병하;박승범
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.129-135
    • /
    • 2000
  • Double boss type composite pressure bottles have been developed widely but single boss type had not because there are some difficulty in technical point. In this paper a research was performed to develop composite pressure vessel in conjunction with design, fabrication, and test. Fiber pattern and angles were decided by CADFIL software and they are [liner/$15^{\circ}$/$15^{\circ}$/$90^{\circ}$/$18^{\circ}$/$90^{\circ}$/$21^{\circ}$/$21^{\circ}$/$90^{\circ}$]. Fabrication of bottles was done by AEA's 5-axis filament winding machine. During fabrication fiber optic sensor were embedded to measure were behavior of structure at the applied internal pressure. Even though satisfied test results were not obtained, the experimental set-up of fiber optics showed the possibility for the application of filament wound vessels. However, the conventional strain and fabrication of single boss composite bottles.

  • PDF

복합재료 산소 압력용기의 성형 및 내압 시험 (Processing and Pressure Test of Filament Wound Composite Pressure Vessels for Oxygen Tanks)

  • 황병선;김병하;김병선;박승범;엄문광
    • Composites Research
    • /
    • 제14권3호
    • /
    • pp.10-17
    • /
    • 2001
  • 복합재료 압력용기를 개발하기 위하여 설계, 제작, 시험을 연계한 연구가 수행되었다. 섬유의 와인딩 패턴 및 각도는 CADFIL 코드를 활용하여 결정하였고, 그 각도는 [$liner/15^{\circ}/15^{\circ}/90^{\circ}/18^{\circ}/90^{\circ}/21^{\circ}/21^{\circ}/90^{\circ}$] 이었다. 압력용기의 제작은 5축 필라멘트 와인딩기를 활용하여 이루어졌다. 제조 공정 중에 광섬유 센서를 매립하여 내부 압력이 가해질 때 각 지점에서 스트레인을 측정하였다. 광섬유가 실험적으로 사용된 반면에 일반적으로 적용하는 스트레인 게이지를 부착하여 안정적인 시험결과를 확보하였다. 가압 시험결과는 유한요소 해석 결과와 비교하였고 그 결과는 유사한 일치를 보여주었다. 이 과정을 통하여 개구부 한개를 지닌 복합재료 압력용기의 설계, 제작 및 시험평가가 성공적으로 이루어져 제조기술의 확보가 가능하였다.

  • PDF

폐기물 매립지 최종복토 차단층으로서 Geosynthetic Clay Liner 적용성 평가 (The Evaluation of Geosynthetic Clay Liner as a barrier layer for the Final Cover System in landfill)

  • 이정란;문철환;정찬기;이재영
    • 한국지반신소재학회논문집
    • /
    • 제3권2호
    • /
    • pp.23-29
    • /
    • 2004
  • 폐기물 매립지 최종복토의 주요 기능중 하나는 매립지 내부로 우수의 침투를 억제하는 것이다. 이러한 기능을 담당하는 차단층은 폐기물 관리법상 다짐점토층(45cm)의 단독포설이나 다짐점토층(30cm)상부에 HDPE를 복합으로 포설하도록 되어 있다. 그러나 바닥층 사면부에서와 같이 최종복토층 끝단 사면부에서 다짐점토층의 포설이 어렵다는 문제점이 있다. 따라서 본 연구에서는 토목합성물질 사이에 차수성이 뛰어난 벤토나이트를 삽입한 토목합성수지점토라이너(Geosynthetic Clay Liner; GCL)를 다짐점토층 대신 적용하여 최종복토 끝단 사면부에서 차단층으로서의 적용가능성을 평가해 보고자 HELP 분석과 사면에서의 안정성 검토, 환경적 내구성 검토를 수행하였다. 그 결과 GCL이 기존의 다짐점토층보다 안정된 결과를 나타내고 있어 GCL을 최종복토의 차단층으로서 사용하도록 제안하고자 한다.

  • PDF

전체 화염 및 단일 화염 노출 조건에서 복합재료 용기 표면 온도 변화 비교 (Test Results of Composite Cylinder Surface Temperature change between Pool Fire and Single Impinging Jet Flame Exposure Condition)

  • 이재훈;황준호;김영섭;김효
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.648-651
    • /
    • 2009
  • 탄소섬유강화플라스틱(CFRP:Carbon Fiber Reinforced Plastic)용기의 외부에 화재가 발생할 경우 함침된 수지(Resin)가 탄화되면서 자체 강도가 약화되고 충전된 가스가 외부 온도 상승에 따라 압력 상승이 발생하여 용기의 폭발로 이어지는 사고가 발생할 개연성이 높다. 화염 노출조건에서 복합재료 용기의 폭발을 방지하기 위하여 용기용 밸브에 내장된 온도감응식 압력안전장치(TPRD:Thermally activated Pressure Relief Device) 작동 성능을 검증하기 위한 방법으로 화염실험(Bonfire test)를 실시하고 있으나, 개방 공간에서 실시되는 이 실험은 표면 온도 변화가 매우 크게 발생하여 실험에 대한 재현성(Reproducibility)에 의문이 제기되고 있다. 따라서, 표면 온도를 일정하게 유지하기 위한 실험 방법의 개선이 필요하다. 본 연구에서는 경유+heptane을 이용한 전체 화염에 노출되는 경우와, 천연가스를 이용한 단일화염에 노출되는 경우의 실험 결과 비교를 통하여 화염 노출 표면 온도를 일정하게 유지하기 위한 가열 방법의 타당성을 검토하였다. 또한, 복합재료 라이너(Liner)의 온도 변화 비교를 통하여 집중화염 노출 조건에서 열전달 특성을 알아보았다.

  • PDF

수복방법에 따른 복합레진 및 글라스아이오노머 시멘트의 변연부 미세누출에 관한 연구 (A STUDY ON THE MICROLEAKAGE OF COMPOSITE RESIN AND GLASS IONOMER CEMENT WITH VARYING FILLING METHODS)

  • 황호길;박주식
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.174-186
    • /
    • 1996
  • The purpose of this study was to evaluate the adaptability to tooth structure of composite resin and glass ionomer cement according to filling methods. In this study. two class V cavities were prepared on the buccal and lingual surface of each tooth of forty extracted human premolars. and they were randomly assigned into 4 groups with 10 teeth. The cavities of each group were filled with the CLEARFIL FII self curing resin(Control Group), Z-100 light curing resin (Group 1). $Vitremer^{TM}$ light curing glass ionomer cement(Group 2) and Z-100 light curing resin over the $Vitremer^{TM}$ liner(Group 3). The specimens underwent temperature changed from $5^{\circ}C$ to $55^{\circ}C$ five hundred times. After thermocycling. specimens were immersed in 2% methylene blue solution and stored in 100% relative humidity at $37^{\circ}C$ for 24 hours. And then. the specimens sectioned buccolingually. Degree of dye penetration at tooth-restoration interfaces were examined by Tool maker's microscope(x 200) and Image analyzer. The results were as follows : 1. On the occlusal margin. among the experimental groups. the group 2 showed the highest dye penetration($2.40{\pm}0.68$) and the group 3 showed the lowest dye penetration($1.15{\pm}0.37$). There was significant difference among the experimental groups(p<0.001). 2. On the gingival margin, among the experimental groups, the group 1 showed the highest dye penetration($3.30{\pm}0.57$) and the group 2 showed the lowest dye penetration($1.65{\pm}0.49$). There was significant difference among the experimental groups(p>0.001). 3. About total degree of dye penetration, the group 1 showed the highest dye penetration($2.25{\pm}1.17$) and the group 3 showed the lowest dye penetration ($1.43{\pm}0.55$). There was significant difference among the experimental groups(p<0.001). 4. The sum of dye penetration at occlusal margin was less than gingival margin. There was significant difference between occlusal margin and gingival margin (p<0.001). The results showed that differences were more pronounced at the gingival margin. Composite restorations inserted over the glass-ionomer liner demonstrated significantly less leakage than single restoration that used composite resin or glass-ionomer cement.

  • PDF

침하에 의한 폐기물 매립지 최종복토층 HDPE의 영향에 관한 연구 (The Effects of HDPE by Landfill Settlements in the Final Cover System)

  • 문철환;이재영;전한용
    • 한국지반신소재학회논문집
    • /
    • 제2권3호
    • /
    • pp.11-18
    • /
    • 2003
  • 최종복토의 설계에 있어 가장 중요한 요소 중 하나는 매립지 내부로 우수의 침투를 제한하는 것이다. 우수의 침투는 침출수 발생량을 증가시켜 침출수 처리 비용의 증가에 따른 매립지 운영 비용을 증가 초래한다. 따라서, 매립지의 최종복토층은 우수의 침투를 최소화하기 위해 단독의 다짐점토층 또는 HDPE와 다짐점토층의 복합으로 구성된 차단층을 포설하도록 되어 있다. 그러나 다짐점토층과 HDPE는 매립 폐기물의 분해에 의해 발생하는 침하에 의해 손상이나 파손이 발생할 우려가 있다. 따라서 본 연구는 매립 종료 후 침하에 따른 폐기물 매립지 최종복토층 HDPE의 영향에 대해 평가하고자 수행되었다. 현장시험시공과 lysimeter test, 최종복토 후 침하 예측 결과 최종복토층의 HDPE는 침하에 의한 영향을 크게 받지 않는 것으로 나타나 침하에 대해 안정하다고 할 수 있다.

  • PDF

5급 와동에서 수종의 상아질 접착제에 따른 미세누출의 비교 (THE COMPARISON OF MICROLEAKAGE OF CLASS V COMPOSITE RESIN RESTORATIONS WITH VARIOUS DENTIN BONDING SYSTEMS)

  • 임연희;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.153-161
    • /
    • 2001
  • The purpose of this study was to evaluate microleakage of six current dentin bonding systems. In this in vitro study, class V cavities were prepared on buccal and lingual surfaces of thirty extracted human molars. Each margin was on enamel and dentin/cementum. Experimental teeth were randomly divided into six groups of 5 each. Group 1 : Scotchbond Multi-Purpose; Group 2 : Single Bond; Group 3 : Prime&Bond NT ; Group 4 : Clearfil Liner Bond 2 ; Group 5 : MAC Bond II ; Group 6 : One-up Bond F. The bonding agent and composite resin were applied to class V cavities according to manufacturer's directions. After thermocycling, the specimens were immersed in 0.5% basic fuchsin dye solution for 6 hours and sectioned longitudinally through the center of the restoration with a low speed diamond saw. The degree of microleakage was measured as the extent of dye penetration under the stereomicroscope at $\times$20. The data were analyzed using one way ANOVA. When significant differences found. multiple comparisons were made using Duncan's Multiple Range Test. The results of this study were as follows: 1. In all groups, leakage value seen at the enamel margin was significantly lower than that seen at the dentin margin(P<0.001). 2. At the enamel margin, none of the dentin bonding systems used in this study showed statistically significant difference in leakage values(P<0.05). 3. At the cementum margin, group 3 showed the highest leakage value, and others were decreased as group 5, 6, 4 in that order, and group 1, 2 showed the lowest leakage value. There was statistically significant difference between group 3 and the other groups except for group 5(P<0.05).

  • PDF

상아질-레진 계면의 공초점 현미경적 형태 및 전단결합강도와의 관계 (CONFOCAL LASER SCANNING MICROSCOPIC MORPHOLOGY OF DENTIN-RESIN INTERFACE AND ITS RELATIONSHIP WITH SHEAR BOND STRENGTH)

  • 최낙원;조병훈;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.310-321
    • /
    • 1999
  • In this in vitro study, confocal laser scanning microscopic morphology of dentin-resin interface and its relationship to shear bond strength were investigated after the exposed dentin surfaces were treated with 3 different kinds of dentin adhesive systems[three-step; Scotchbond Multi-Purpose Plus(SMPP), self-priming bonding resin; Single Bond(SB), self-etching primer; Clearfil Liner Bond 2(LB2)]. 52 extracted human molar teeth without caries and/or restorations. The experimental teeth were randomly divided into three groups of seventeen teeth each. In five teeth of each group, class V cavities(depth: 1.5mm) with 900 cavosurface angles were prepared at the cementoenamel junction on buccal and lingual surfaces. Bonding resins of each dentin adhesive system were mixed with rhodamine B. Primer of SMPP was mixed with fluorescein. In group 1. the exposed dentin was conditioned with etchant, applied with above primer and bonding resin of SMPP. In group 2, with etchant and self-priming bonding agent of SB. In group 3, with self-etching primer and bonding agent of LB2. After treatment with dentin adhesive systems, composite resin were applied and photocured. The experimental teeth were cut longitudinally through the center line of restoration and grounded so that about $90{\mu}m$-thick wafers of buccolingually orientated dentin were obtained. And, $70{\sim}80{\mu}m$-thick wafers sectioned horizontally, thus presenting a dentinal tubules at 900 to the cut surface of a remaining tooth, were obtained. Primer of SMPP mixed with rhodamine B was applied to these wafers. Confocal laser scanning microscopic investigations of these wafers were done within of 24 hours after treatment. To measure shear bond strength, the remaining twelve teeth of each group were grounded horizontally below the dentinoenamel junction, so that no enamel remained. After applying dentin adhesive systems on the dentin surface, composite was applied in the shape of cylinder. The cylinder was 5mm in diameter, and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. It was concluded as follows ; 1. Hybrid layer of SMPP(mean: $4.56{\mu}m$) was thicker than that of any other groups. This value was not statistically significant thicker than that of SB(mean: $3.41{\mu}m$, p>0.05), and significant thicker than that of LB2(mean: $1.56{\mu}m$, p<0.05). There was a statistical difference between SB and LB2(p<0.05). 2. Although there were variations in the length of resin tag even in a sample, and in a group, most samples in SMPP and SB showed resin tags extending above $20{\mu}m$. But samples in LB2 showed resin tags of $10{\mu}m$ at best. 3. Besides primer's infiltration into demineralized peritubular dentin and dentinal tubules, fluorophore of primer was detected in the lateral branches of dentinal tubules. 4. All groups demonstrated statistically significant differences from one another(p<0.05), with shear bond strengths given in descending order as follows: SMPP(18.3MPa), SB(16.0MPa) and LB2(12.4MPa). 5. LB2 having thinnest hybrid layer($1.56{\mu}m$) showed the lowest shear bond strength(12.4MPa).

  • PDF