• Title/Summary/Keyword: Single Device

Search Result 1,727, Processing Time 0.031 seconds

Energy Transfer Phenomenon in Organic EL Devices Having Single Emitting Layer (단층형 유기 EL 소자의 에너지 전달 특성에 관한 연구)

  • Kim, Ju-Seung;Seo, Bu-Wan;Gu, Hal-Bon;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.331-334
    • /
    • 2000
  • The organic electroluminescent(EL) device has gathered much interest because of its large potential in materials and simple device fabrication. We fabricated EL devices which have a blended single emitting layer containg poly(Nvinylcarbazole)[PVK] and poly(3-dodecylthiophene)[P3DoDT]. The molar ratio between P3DoDT and PVK changed with 1:0, 2:1 and 1:1. To improve the external quantum efficiency of EL devices, we applied insulating layer, LiF layer between polymer emitting layer and AI electrode. All of the devices emit orange-red light and it's can be explained that the energy transfer occurs from PVK to P3DoDT. Within the molar ratio 1:0, 2:1 and 1:1, the energy transfer was not saturated, which results in the not appearance of PVK emission in the blue region. In the voltage-current and voltage-light power characteristics of devices applied LiF layer, current and light power drastically increased with increasing with applied voltage. In the consequence of the result, the light power of the device have a molar ratio 1:1 with LiF layer was about 10 times larger than that of the device without PVK at 6V.

  • PDF

The Effect of Intervention on Hallux Valgus Patient's Foot Pressure (중재방법에 따른 엄지발가락 가쪽휨증 환자의 발바닥 압력분포에 미치는 영향)

  • Kim, Hosung;Kim, Myungchul;Lee, Minsoo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.3 no.2
    • /
    • pp.63-72
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the foot pressure of subjects with hallux valgus following conservative management. Methods: The subjects (20 females) were divided into 2 groups; Hallux valgus group (10) and Control group (10) who could evaluate questionnaire & weight bearing X-ray. All the participants were evaluated distribution of foot pressure by Zebris FDM-S system with conservative management (taping therapy and hallux valgus device) during single-limb stance. Results: The Hallux valgus group (HVG) was significantly different than Control group (CG) in hallux valgus angle(p<0.05). The Hallux valgus group with Foot Device (HVG-FD), Hallux valgus group with Taping (HVG-Tp) and Hallux valgus group with Foot device and Taping (HVG-FD&Tp) was not significantly different than CG in hallux valgus angle (p<0.05). The HVG was not significantly different than CG in forefoot (p1, p2, p3), significantly different than CG in rearfoot (p7) about foot pressure during single-limb stance (p<0.05). The HVG-FO and HVG-FO and TP was significantly different than HVG in forefoot (p1, p2, p3), on significantly different than HVG in rearfoot (p7) about foot pressure during single-limb stance (p<0.05). There was significantly correlation HVG-FO and HVG-FO & TP in forefoot (p1, p2, p3) was negative correlation (p<0.05) and in rearfoot (p7) was positive correlation (p<0.05). Conclusion: This study showed that hallux valgus were effected hallux valgus angle and foot pressure by various treatment methods during single-limb stance. Further study is needed to measure various age and work with hallux valgus for clinical application.

Development and application of the magnetic field device for single crystal growth (자기장 단결정 성장장치의 개발과 적용)

  • Kim, Shin Ae;Cho, Sang-Jin;Magay, Elena;Ryu, Sun-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • The three-dimensional structure of the proteins, including the location of the hydrogen atoms can be analyzed by using neutron diffraction. In order to grow single crystals for neutron diffraction experiments, we developed a simple magnetic field device with the commercial magnets and succeeded in growing hen egg-white lysozyme single crystals of more than 1 $mm^3$ in volume using this device. The crystals grown with a magnetic field were larger and had perfect transparency, whereas the crystals grown without a magnetic field had micro-cracks. The result of the X-ray measurement showed a good resolution and small mosaicity for the crystals grown in the presence of a magnetic field.

Single Phase Switched Reluctance Motor for Vacuum Cleaner (진공청소기용 단상 스위치드 리럭턴스 모터)

  • Lim, Jun-Young;Jung, Yun-Chul;Kim, Sang-Young;Choi, Yong-Won;Kim, Jungn-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.247-251
    • /
    • 2001
  • Universal motors are mainly used for vacuum cleaner application. There are a lot of researches on SRM that applys home appliance throughout the world. The manufacturing cost of SRM drive makes it hard to expand its application to home appliance. This paper presents Single Phase SRM for the vacuum cleaner that has advantge in cost and performance over conventional universal motor. This paper proposes new power device driving scheme by using SRM switching characteristic. The driving scheme is very simple and inexpensive. Dwell Time Control method is used for the minimum switching loss of power device. The switching frequency of power device is less than 4.5kHz at 45,000rpm. By use of this scheme, power device based on very small switching losses can be used on SRM drive. Also, the biggest problem in single phase SRM is starting, this paper shows a new starting algorithm with two hall sensors, accelerating and running sensors, respectively. Finally, the proposed Single Phase SRM achieves higher efficiency and long life time compared to universal motor. Its life time is more than 1500 hours. Its life time is extended 4 times than that of conventional motor and its suction power is increased $20\%$ at the same volume of conventional universal motor.

  • PDF

Is it Beneficial to Utilize an Articulating Instrument in Single-Port Laparoscopic Gastrectomy?

  • Kim, Amy;Lee, Chang Min;Park, Sungsoo
    • Journal of Gastric Cancer
    • /
    • v.21 no.1
    • /
    • pp.38-48
    • /
    • 2021
  • Purpose: As the number of gastric cancer survivors is increasing and their quality of life after surgery is being emphasized, single-port surgery is emerging as an alternative to conventional gastrectomy. A novel multi-degree-of-freedom (DOF) articulating device, the ArtiSential® device (LivsMed, Seongnam, Korea), was designed to allow more intuitive and meticulous control for surgeons facing ergonomic difficulties with conventional tools. In this study, we evaluated the feasibility of this new device during single-port laparoscopic distal gastrectomy (SP-LDG) for early gastric cancer (EGC) patients. Materials and Methods: Consecutive patients diagnosed with EGC who underwent SP-LDG with ArtiSential® (LivsMed) graspers between April 2018 and August 2020 were enrolled in the study. The clinical outcomes were compared with those of a control group, in which prebent graspers (Olympus Medical Systems Corp) were used for the same procedures. Results: Seventeen patients were enrolled in the ArtiSential® group. There was no significant difference in operative time (205.4±6.0 vs. 218.1±9.9 minutes, P= 0.270) or the quality of surgery, in terms of the number of retrieved lymph nodes (49.5±3.5 vs. 45.9±4.0, P=0.473), length of hospital stay (15.4±2.0 vs. 12.4±1.3 days, P=0.588), and postoperative complications (40.0% vs. 41.2%, P=0.595), between the ArtiSential® group and the control group. Conclusions: The new multi-DOF articulating grasper is feasible and can be used as an alternative for prebent graspers during SP-LDG.

A Study of Orthognathic Surgical Guides with Two-stage Split Path (2단 절개 형태를 가지는 악교정 수술 장치 연구)

  • Min Uk, Kim;Chung Hwan, Park;Ji Hyoung, Rho;Eui Sung, Jung;Young Sang, Park;Dong Guk, Kim;Yohan, Seo;Young Jea, Woo;Jong Min, Lee
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.382-389
    • /
    • 2022
  • In this study, the accuracy of the orthognathic surgical guides with single-stage split path was upgraded to realize orthognathic surgical guides with two-stage split path and simulated surgery was performed to verify its accuracy. As a result, the average error distance between the simulation model and the scan model was + 0.289 / - 0.468 mm (standard deviation 0.128), which was confirmed to be within ± 0.5 mm, which is a clinically acceptable level. Also, there was no significant difference compared with the average value of + 0.313 / - 0.456 mm (average standard deviation 0.106) of the conventional single-stage split path type device. It is judged that the use of this device can contribute to the reduction of surgical time and increase in accuracy since a separate finishing operation for bone preparation is unnecessary.

Authentication for Single/Multiple Domain using Attribute Certificates (유비쿼터스 컴퓨팅 환경에서 속성 인증서를 이용한 단일/멀티 도메인 인증)

  • Lee Deok-Gyu;Park Hee-Un;Lee In-Yeong
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.3
    • /
    • pp.291-300
    • /
    • 2005
  • The Ubiquitous computer environment is thing which invisible computer that is not shown linked mutually through network so that user may use computer always is been pervasive. Intend computing environment that can use easily as user wants and it is the smart environment that user provides context awareness that is wanting computing environment. This Ubiquitous computing contains much specially weak side in security. Masquerade attack of that crawl that is quoted to user or server among device that is around user by that discrete various computing devices exist everywhere among them become possible. Hereupon, in this paper, proposed method that have following characteristic. Present authentication model through transfer or device. Suggest two method that realize authentication through device in case of moved to method(MD: Multi Domain) and user ownself space(SD: Single Domain) that realize authentication through device in case of moved user's direct path who device differs.

Development of a Single Fire Alarm System of House Based on Wireless Communication (무선 감응식 주택 단독 화재 경보 시스템 개발)

  • Park, Hyeon-Ho;Cho, Seong-Jin;Park, Byeong-Hwa;Heo, Jeong-Hun;Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1017-1022
    • /
    • 2018
  • In this paper, a single house fire alarm device, which can solve the problem of fire perception at midnight time and the attenuation of alarm signal due to the wall between rooms based on the wireless communication, was developed. The radio controlled fire alarm device was designed to allow fire to be recognized quickly and accurately by monitoring the temperature and $CO_2$ concentration based on the temperature sensor and gas sensor, by detecting the fire in the house and by transmitting the fire alarm to the individual wireless alarms of other rooms using the wireless transmission/reception module. Using the Arduino as a main control device, three independent fire alarm device prototypes were made, and their usefulness was verified by the correct operations in temperature and gas tests.

BPM Design Optimization of Mach-Zehnder Type Tandem Optical Switch and Its Operational Characteristics (2단 종속 접속 마하젠더형 광스위치의 BPM 최적설계 및 동작특성)

  • Choi, Young-Kyu;Kim, Gi-Rae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1829-1834
    • /
    • 2008
  • An optical switch/modulator is designed and the light propagating characteristics is analyzed by the simplified BPM. The distinctive feature of the switch/modulator is that all the waveguide branches are designed to be single-mode. Principle of the device is based on the coupled mode theory in the Y-junction interconnecting waveguide. In spite of all the waveguides are designed to be single-mode, adjusting the interconnecting waveguide length of the device, the same characteristics as existing device up to date is obtainable. Numerical results show that the switching characteristics periodically depends on the interconnecting waveguide length with a spatial of about 150${\mu}m$ in the Ti:LiNbO3 step index waveguide. The concept of design would be utilized effectively in fabricating the monolithic high density of optical integrated circuit.

A Novel Body-tied Silicon-On-Insulator(SOI) n-channel Metal-Oxide-Semiconductor Field-Effect Transistor with Grounded Body Electrode

  • Kang, Won-Gu;Lyu, Jong-Son;Yoo, Hyung-Joun
    • ETRI Journal
    • /
    • v.17 no.4
    • /
    • pp.1-12
    • /
    • 1996
  • A novel body-tied silicon-on-insulator(SOI) n-channel metal-oxide-semiconductor field-effect transistor with grounded body electrode named GBSOI nMOSFET has been developed by wafer bonding and etch-back technology. It has no floating body effect such as kink phenomena on the drain current curves, single-transistor latch and drain current overshoot inherent in a normal SOI device with floating body. We have characterized the interface trap density, kink phenomena on the drain current ($I_{DS}-V_{DS}$) curves, substrate resistance effect on the $I_{DS}-V_{DS}$ curves, subthreshold current characteristics and single transistor latch of these transistors. We have confirmed that the GBSOI structure is suitable for high-speed and low-voltage VLSI circuits.

  • PDF