• Title/Summary/Keyword: Single Channel

Search Result 1,817, Processing Time 0.022 seconds

A Study On the Design of a Floating Point Unit for MPEG-2 AAC Decoder (MPEG-2 AAC 복호기를 위한 부동소수점유닛 설계에 관한 연구)

  • 구대성;김필중;김종빈
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.4
    • /
    • pp.355-355
    • /
    • 2002
  • In this paper, we designed a FPU(floating point unit) that it is very important and requires of high density when digital audio is designed. Almost audio system must support the multi-channel and required for high quality. A floating point arithmetic function in MPEG-2 AAC that implemented by hardware is able to realtime decoding when DSP realization. The reason is that MPEG-2 AAC is compatible to the Audio field of MPEG-4 and afterwards. We designed a FPU by hardware to increase the speed of a floating point unit with much calculation part in the MPEG-2 AAC Decoder. A FPU is composed of a multiplier and an adder. A multiplier used the Radix-4 Booth algorithm and an adder adopted 1's complement method for speed up. A form of a floating point unit has 8bit of exponent part and 24bit of mantissa. It's compatible with the IEEE single precision format and adopted a pipeline architecture to increase the speed of a processor. All of sub blocks are based on ISO/IEC 13818-7 standard. The algorithm is tested by C language and the design does by use of VHDL(VHSIC Hardware Description Language). The maximum operation speed is 23.2MHz and the stable operation speed is 19MHz.

Developing In-Band Full-Duplex Radio in FRS Band (동일대역 전이중 방식 FRS 대역 무전기 개발)

  • Kim, Jae-Hun;Kwak, Byung-Jae;Kim, Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.10
    • /
    • pp.769-778
    • /
    • 2017
  • In this paper, a self-interference signal cancellation(SIC) circult for In-band Full-Duplex has been developed and tested in RF/analog region. By use of this SIC circuit, a FM two-way radio has been developed working at FRS(Family Radio Service) band. The two-way radio device is transmitting the FM modulated signal and demodulating the wanted FM signal at the same time. A circulator is used to enable a single antenna to transmit and receive simuultaenously. The receiver circuit needs to cancel out the self-interference signal due to the transmit signal. A vector modulator(VM) is used to control the phase and magnitude of the esitmated signal. And in-phase and quadrature correlators are used to figure out the optimal coefficients of the VM to remove the self-interference signal according to the change of channel environment. In this work, SA58646 has been used as the FM transceiver, and the system is tested with a frequency of 465 MHz and a bandwidth of 12.5 kHz FM signal. The output power is 17.2 dBm at the antenna port, and the self intererence signal level is measured -49.2 dBm at the receiver end. Therefore the SIC level is measured by 66.4 dB.

The Analysis of 40Hz Event-Related Potentials in Schizophrenia (정신분열병 환자에서 40Hz 뇌 사건관련전위에 관한 연구 : 분석 방법론적 측면)

  • Youn, Tak;Park, Hae-Jeong;Kang, Do-Hyung;Kim, Myung-Sun;Kim, Jae-Jin;Kwon, Jun Soo
    • Korean Journal of Biological Psychiatry
    • /
    • v.8 no.2
    • /
    • pp.251-257
    • /
    • 2001
  • Backgrounds : Gamma band oscillatory activity is considered to be related to cognitive functions and illustrates that the concept of event-related oscillations bridges the gap between single neurons and neural assemblies. An event-related gamma oscillation is the time-locked responses of specific frequency, and can be identified by computing the amplitude frequency characteristics of the averaged event-related potentials(ERPs) after stimulation. Objectives : We purposed to present experimental paradigm to investigate ${\gamma}$-band oscillation activities from the recording of ERPs by using auditory oddball paradigm and investigate the difference of ${\gamma}$-band activity between schizophrenia and normal controls. Methods : The ERPs resulting from auditory stimuli with oddball paradigm in a group of schizophrenics(n=11), and also a group of age-, sex-, and handedness matched normal controls, were recorded by 128 channel EEG. The ${\gamma}$-band oscillatory activities were calculated by using time-frequency wavelet decomposition of the signal between 20 and 80Hz. The ${\gamma}$-band oscillatory activities of both groups were compared by t-test. Results : The ${\gamma}$-band oscillatory of the leads Fz, Cz, and Pz of both groups were represented well in the time-frequency maps. Significant increases of the ${\gamma}$-band activity in normal controls compared with schizophrenics were observed around 160 msec, 350 msec, and 800 msec after stimulation. Conclusions : Our results suggested that the increment in ${\gamma}$-band oscillatory activity during cognitive operations and decreased ${\gamma}$-band activity in schizophrenics may be associated with the cognitive dysfunctions and the pathophysiology of the schizophrenia.

  • PDF

Comparative Investigation on 4 types of Tunnel Field Effect Transistors(TFETs) (터널링 전계효과 트랜지스터 4종류 특성 비교)

  • Shim, Un-Seong;Ahn, TaeJun;Yu, YunSeop
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.5
    • /
    • pp.869-875
    • /
    • 2017
  • Using TCAD simulation, performances of tunnel field-effect transistors (TFETs) was investigated. Drain current-gate voltage types of TFET structure such as single-gate TFET (SG-TFET), double-gate TFET (DG-TFET), L-shaped TFET (L-TFET), and Pocket-TFET (P-TFET) are simulated, and then as dielectric constant of gate oxide and channel length are varied their subthreshold swing (SS) and on-current ($I_{on}$) are compared. On-currents and subthreshold swings of the L-TFET and P-TFET structures with high electric constant and line tunneling were 10 times and 20 mV/dec more than those of the SG-TFET and DG-TFET using point tunneling, respectively. Especially, it is shown that hump effect which dominant current element changes from point tunneling to line tunneling, is disappeared in P-TFET with high-k gate oxide such as $HfO_2$. The analysis of 4 types of TFET structure provides guidelines for the design of new types of TFET structure which concentrate on line tunneling by minimizing point tunneling.

Cluster Coordinator Node Based Inter-Cell Interference Management Methods in Heterogeneous Networks (이기종 네트워크에서 클러스터 코디네이터 노드 기반의 셀간 간섭 관리 방법)

  • Yang, Mochan;Wu, Shanai;Shin, Oh-Soon;Shin, Yoan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.3
    • /
    • pp.277-288
    • /
    • 2013
  • 3GPP LTE-Advanced (Third Generation Partnership Project Long Term Evolution-Advanced) as a next generation mobile communication standard introduced small base stations such as femto cells or pico cells, and D2D (Device-to-Device) communications between mobiles in the proximity in order to satisfy the needs of rapidly growing wireless data traffic. A diverse range of topics has been studied to solve various interference situations which may occur within a single cell. In particular, an introduction of a small base station along with D2D communication raises important issues of how to increase the channel capacity and frequency efficiency in HetNets (Heterogeneous Networks). To this end, we propose in this paper methods to manage the interference between the macro cell and other small cells in the HetNet to improve the frequency efficiency. The proposed CCN (Cluster Coordinator Node)-assisted ICI (Inter-Cell Interference) avoidance methods exploit the CCN to control the interference in HetNet comprising of an MeNB (Macro enhanced Node-B) and a large number of small cells. A CCN which is located at the center of a number of small cells serves to avoid the interference between macro cell and small cells. We propose methods of resource allocation to avoid ICI for user equipments within the CCN coverage, and evaluate their performance through system-level computer simulations.

Discharge Characteristics of Plasma Jet Doping Device with the Atmospheric and Ambient Gas Pressure (플라즈마 제트 도핑 장치의 대기 및 기체의 압력 변화에 대한 방전 특성)

  • Kim, J.G.;Lee, W.Y.;Kim, Y.J.;Han, G.H.;Kim, D.J.;Kim, H.C.;Koo, J.H.;Kwon, G.C.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.301-311
    • /
    • 2012
  • Discharge property of plasma jet devices is investigated for the application to the doping processes of crystalline solar cells and others. Current-voltage characteristics are shown as the typical normal-glow discharge in the various gas pressure of plasma jets, such as in the atmospheric plasma jets of Ar-discharge, in the ambient pressure of atmospheric discharge, and in the ambient Ar-pressure of Ar-discharge. The discharge voltage of atmospheric plasma jet is required as low as about 2.5 kV while the operation voltage of low pressure below 200 Torr is low as about 1 kV in the discharge of atmospheric and Ar plasma jets. With a single channel plasma jet, the irradiated plasma current on the doped silicon wafer is obtained high as the range of 10~50 mA. The temperature increasement of wafer is normally about $200^{\circ}C$. In the result of silicon wafers doped by phosphoric acid with irradiating the plasma jets, the doping profiles of phosphorus atoms shows the possibility of plasma jet doping on solar cells.

Effect of Acupuncture(PC6) on Behavior, Dopamine Release in the Nucleus Accumbens in Rats Sensitized to Morphine (몰핀에 민감화된 흰쥐의 내관부위 자침이 행동과 측핵의 도파민 유리에 미치는 효과)

  • Kim, Sang-Ho;Lyu, Seung-Jun;Kim, Tae-Heon;Kang, Hyung-Won;Lyu, Yeoung-Su
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.4
    • /
    • pp.982-992
    • /
    • 2005
  • Acupuncture as a therapeutic intervention is widely used for the treatment of many functional disorders such as substance abuse and mental dysfunction. Clinical trials are currently underway to determine the effectiveness of acupuncture in the treatment of drug addiction. Yet, there are still many unanswered questions about the basic mechanism of acupuncture. Studies have shown that both the psychomotor stimulant effects and rewarding properties of addictive drugs, including morphine, are sensitized by repeated drug administration and raised the possibility that both of these effects may De linked to the same or closely overlapping the mesolimbic dopamine systems. Neiguan (PC6) point on the pericardium channel which is associated with the brain and its mental function, has been used to treat mental, psychosomatic disorders and gastroenterological disorders. The present study was designed to investigate the effect of acupuncture on repeated morphine-induced changes in extracellular dopamine levels using in vivo microdialysis and to measure the effect of acupuncture on repeated morphine-induced behavioral changes. Male Sprague-Dawley rats were treated twice a day for three days with increasing doses of morphine (10, 20 and 40 mg/kg, s.c.) or with saline. After 15 days of withdrawal, rats were challenged with morphine hydrochloride (5 mg/kg, s.c.). Acupuncture was applied at bilateral Neiguan (PC6) points for 1min after the morphine challenge. Results showed that acupuncture at the specific acupoint PC6, but not at control points (tail and HE8) significantly decreased both dopamine release, behavior induced by a systemic morphine challenge or a single s.c. morphine injection in the morphine-repeated animals. These results suggest that reduction in sensitization may be one mechanism whereby acupuncture alleviates morphine craving in addicts. Moreover, in a more general sense these results suggest that acupuncture can be used as a therapeutic intervention for correcting reversible malfunction of the body by direction of brain pathway and thus acupuncture can contribute to the biochemical balance in the central nervous system by regulating neurotransmitters.

An Experimental Study on Tip Velocity and Downstream Recirculation Zone of Single Groyne Conditions (단일 횡수제 조건에 따른 선단부 유속과 재순환 영역에 대한 실험 연구)

  • Kang, Joon-Gu;Yeo, Hong-Koo;Kim, Sung-Jung
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.2
    • /
    • pp.143-153
    • /
    • 2005
  • Recently, the concern of groynes that provide us with various ecological environment and improvement of scenary near river as well as hydraulic improvement has greatly increased for naturalized river and ecological river restoration. However there is no adequate design guidelines in Korea. Furthermore there is lack of research for installation of groynes in Korea. Thus, in this study, we have conducted hydraulic modeling test for kinds of groyne and changes of permeability and made a study of the analysis for installation factor of groyne. Experimental conditions were the fixed bed model for flow pattern of groyne tip and separation length about changes of groyne length and permeability. The Experiments were conducted to measure velocity and drift angle at groyne tip. The main study kas measured the groyne tip velocity for a factor of scour and drift angle for velocity increase at center of channel. We have suggested the equation about groyne tip velocity rate(tip velocity/ approach velocity) and area rate(groyne area/ flow area). And In recirculation zone of groyne downstream, To study the basic data of groyne about installation interval has analyzed the change of separation length and incidence angle. We have suggested the equation about separation length rate(separation length/ groyne length), changes of permeability and installation angle.

Geophysical Imaging of Alluvial Water Table and the underlying Layers of Weathered and Soft Rocks (충적층 지하수면 및 그 하부의 풍화암/연암의 경계면 파악을 위한 복합 지구물리탐사)

  • Ju, Hyeon-Tae;Lee, Chul-Hee;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.25 no.3
    • /
    • pp.349-356
    • /
    • 2015
  • Although geophysical methods are useful and generally provide valuable information about the subsurface, it is important to recognize their limitations. A common limitation is the lack of sufficient contrast in physical properties between different layers. Thus, multiple methods are commonly used to best constrain the physical properties of different layers and interpret each section individually. Ground penetrating radar (GPR) and shallow seismic reflection (SSR) methods, used for shallow and very shallow subsurface imaging, respond to dielectric and velocity contrasts between layers, respectively. In this study, we merged GPR and SSR data from a test site within the Cheongui granitic mass, where the water table is ~3 m deep all year. We interpreted the data in combination with field observations and existing data from drill cores and well logs. GPR and SSR reflections from the tops of the sand layer, water table, and weathered and soft rocks are successfully mapped in a single section, and they correlate well with electrical resistivity data and SPS (suspension PS) well-logging profiles. In addition, subsurface interfaces in the integrated section correlate well with S-wave velocity structures from multi-channel analysis shear wave (MASW) data, a method that was recently developed to enhance lateral resolution on the basis of CMP (common midpoint) cross-correlation (CMPCC) analysis.

Reliability improvement of an ion-measuring system using FET sensor array (FET 센서 어레이를 이용한 이온 측정 시스템의 신뢰도 개선)

  • Choi, Jung-Tae;Lee, Seung-Hyup;Kim, Young-Jin;Lee, Young-Chul;Cho, Byung-Woog;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.341-346
    • /
    • 1999
  • In general cases, compared with glass electrode, FET type electrolyte sensors have many advantages. But the drift, memory effect and the poor reproducibility of the FET type electrolyte sensor cause the decrease of the reliability in the measurement system. To improve the reliability, an ion-measuring system using FET type electrolyte sensor array with 8 sensors has been developed. Developed system employed the electronic switchs to connect a signal detecting circuit with 8 sensor array and the system can measure ion concentration of 4 different type electrolyte($H^+$, $Na^+$, $K^+$, $Ca^{2+}$). The signal processing algorithm with insertion sorting method was adopted to enhance the reliability. We measured 3 different ion($H^+$, $Na^+$, $K^+$) to evaluate the performance of developed system. The results show that the designed signal processing algorithm can reduce the error range in comparison with a simple arithmetic mean and the developed system has a good reliability over the previous single channel sensor system.

  • PDF