• Title/Summary/Keyword: Single Bubble

Search Result 144, Processing Time 0.025 seconds

Crystal Growth of LiNbO3 for SAW Devices (SAW Device 응용을 위한 LiNbO3 단결정 성장)

  • 최종건;오근호
    • Journal of the Korean Ceramic Society
    • /
    • v.25 no.1
    • /
    • pp.78-82
    • /
    • 1988
  • Good quality LiNbO3 single crystals which can be applied to SAW devices, were grown by Czochralski method. It was observed that the gas-bubbles were concentrated in ring shape at the outer part of grown crystals, and this anomaly was illustrated by modeling the mechanism of gas-bubble entrapment according to the melt flow pattern in the crucible. And this mechanism was also encertained by observation of solid-liquid interface shape of grown crystals. The optimal condition for good quality crystals was known that the solid-liquid interface shape was slightly concave.

  • PDF

A Facility Design Model for 1300 Capacity School Foodservice with Adjacency and Bubble Diagrams (근접요구도와 버블다이어그램을 적용한 1300식 규모의 학교급식 시설 설계 모델)

  • Jang, Sun-hee;Chang, Hye-Ja
    • Korean Journal of Community Nutrition
    • /
    • v.16 no.1
    • /
    • pp.98-112
    • /
    • 2011
  • This study aimed to suggest a 1300 scale of a middle school foodservice facility floor plan which was compliant to the principle of HACCP, as well as ensuring food and work safety, and the flow of personnel and food materials. which consisted of 46 nutrition teachers and 6 experts, responded with a questionnaire on the relationship of functional area and space. Using their opinions, key principles for the design of the facility were single direction movement of food materials, customers and workers; minimization of the cross-contamination through the separation of functional space; and securement of customer-focused efficiency; staff-centered convenience and efficiency; and work and food safety. After the completion of an adjacency diagram, bubble diagram and program statement, the functional areas of a 1300 scale middle school food-service facility were allocated as follows: $9.9\;m^2$ for the receiving area, $56.1\;m^2$ for the pre-preparation area, $10.5\;m^2$ for the food storage area, $6.0\;m^2$ for the supplies storage area, $97.8\;m^2$ for the cooking area, $33.6\;m^2$ for the service area, $52.5\;m^2$ for dish washing area, cafeteria $410.5\;m^2$, $4.5\;m^2$ for the front room, for a total of $725.8\;m^2$. Expert groups have pointed to limitations within this model as there are no windows in the office for the influx of fresh outside air and a need for the straight line installation of steam-jacket and frying kettles on the sides of windows. This study can be useful as the guidelines for estimating the investment cost of the facility and placing the placement of functional areas and equipment in the renovation of the facility. It can be also useful data for a methodology of foodservice facility design.

Subcultural Style in the Turn of the nst Century High Fashion -The Case of Punk Look- (21세기 전환기 하이패션에 나타난 하위문화 스타일 -펑크 룩을 중심으로-)

  • 임은혁
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.2
    • /
    • pp.71-85
    • /
    • 2003
  • In the turn of the century, fashion designers have not just drawn upon one or two subcultural styles but have extracted elements from many subcultures to use in a single collection. In true postmodern style these are freely combined with historical, cross-cultural and futuristic influences to create new fashions. The process could be explained by bubble-up phenomenon, retroism. pastiche and pursuit of pleasure. In the course of illustrating subcultural styles transformed into mainstream fashion, the case of Punk was studied as a turning point of modernist and postmodern period which have been introduced by high fashion designers since the birth in 1976. The following cases have continued to appear entering upon the third millennium and the aesthetic value of those can be summarized as ambiguity, eclecticism, and deconstruction. In other words. the energy and authenticity of Punk has been considered to be desirable in high fashion, however designers focus on clothing and adornment rather than ideology and lifestyle. The aesthetic property of subcultural style defeats the established notion of standardized fashion and stimulates new consciousness. which allows a room to be diversified and subdivided.

Characterization of SiC-SiC Whisker Matrix Retaining Electrolyte in Phosphoric Acid Fuel Cell (인산형 연료전지용 SiC-SiC Whisker 전해질 매트릭스의 특성)

  • 윤기현;이현임;이근행;김창수
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.8
    • /
    • pp.587-592
    • /
    • 1992
  • Sheets of SiC-SiC whisker maxed matrix were prepared from the mixed slurry of SiC whisker and SiC matrix by the rolling method. With the increase of SiC whisker, the pore size, the porosity and the phosphoric acid absorbency of the matrix were increased, while the bubble pressure was decreased. The activation energy for the transfer of H+ ion was decreased with the increase of mixing ratio of SiC whisker to the SiC matrix from the measurement of hydrogen ion conductivity. The activation energy was evaluated as 0.25 eV when the mixing ratio of SiC whisker to the SiC matrix was 1 : 2 and the activation energy was 0.16 eV for the 2 : 1 matrix. It means that SiC whisker matrix contributes to attain a better microstructure for the diffusion of hydrogen ion. From the measurement of single cell performance of matrix with various mixing ratio, it is concluded that if SiC-SiC whisker maxed matrix has a sufficient bubble pressure to prevent the crossover of H2 gas, the current density of a fuel cell is increased with the increase of acid absorbency of the matrix. Current density was improved from 140 mA/$\textrm{cm}^2$ for 0.25 mm thickness of matrix to 170 mA/$\textrm{cm}^2$ for the 0.20 mm one at 700 mV.

  • PDF

Effects of a single roughness element on Venturi cavitation (단일 거칠기 요소가 벤투리 캐비테이션에 미치는 영향)

  • Jongbin Hwang;Yisu Shin;Jooha Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.1
    • /
    • pp.57-66
    • /
    • 2023
  • In this study, we investigate the effects of a single roughness element on Venturi cavitation. The single roughness element of hemispherical shape is installed at the throat inlet of a Venturi tube. Since the wake behind the roughness element induces an additional pressure drop, cavitation inception occurs at a higher Cavitation number for the Venturi model with the single roughness element than for the Venturi model with no roughness. Cavitation bubbles form along the wake of the roughness element and lengthen in the streamwise direction as the Cavitation number decreases, forming a longitudinal cavitation. With a further decrease in the Cavitation number, the longitudinal cavitation bubble merges with the sheet cavitation initiated from the exit edge of the Venturi tube throat, followed by the shedding of cloud cavitation. The merging of the longitudinal cavitation and sheet cavitation is accompanied by a sudden decrease in the discharge coefficient and an increase in the pressure loss coefficient as it chokes the flow inside the Venturi tube.

Effects of Entrained Air on the Characteristics of a Small Screw-type Centrifugal Pump (공기 흡입이 소형 스크류식 원심펌프의 특성에 미치는 영향)

  • Kim, You-Taek;Tanaka, Kazuhiro;Lee, Young-Ho;Matsumoto, Yoichiro
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.37-44
    • /
    • 1999
  • In a screw-type centrifugal pump, the pump head deteriorates from single-phase flow to the choke due to an increased air entrainment at a wide tip clearance compared to that of a narrow tip clearance. Moreover, at a narrow tip clearance, the pump head became partially higher in a two-phase flow than that of a single-phase flow near the best efficiency point in low void fraction region. Therefore, we observed the internal flow pattern by using a stroboscope and we measured the mean size of bubbles from the images obtained with a high speed camera. Then, we investigated the influences of the mean size of bubbles, tip clearances and flow patterns on pump performance.

  • PDF

Experimental Study on Microexplosive Burning of Binary Fuel Droplets (이성분 연료 액적 연소에 관한 실험적 연구)

  • Ghassemi, Hojat;Baek, Seung-Wook;Khan, Qasim Sarwar
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.110-119
    • /
    • 2005
  • The combustion characteristics of binary component single droplets hanging at the tip of a quartz fiber are studied experimentally at different environmental pressures and temperatures under normal gravity. Normal Heptane and Normal Hexadecane are selected as two fuels with high difference in boiling temperatures. A falling electrical furnace in a high pressure vessel has provided high temperature environment. Nitrogen and air have formed the environment to study evaporation and combustion, respectively. The initial diameter of droplet was ranging from 1.1 to 1.3 mm. The evaporation and combustion processes were recorded by a high speed digital camera. Some characteristics of droplet burning under different environment conditions and different droplet composition have been investigated. Microexplosion of droplet take places under atmospheric pressure. Bubble formation and its consequent result, incomplete droplet disintegration which presents in all binary compositions, do not appear at high pressure. The initiation of combustion, always takes place in the bottom of droplet due to buoyancy effect of relatively cold fuel vapor. Also, the burning of binary droplet produces soot when the pressure is high.

  • PDF

Simulation on mass transfer at immiscible liquid interface entrained by single bubble using particle method

  • Dong, Chunhui;Guo, Kailun;Cai, Qinghang;Chen, Ronghua;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1172-1179
    • /
    • 2020
  • As a Lagrangian particle method, Moving Particle Semi-implicit (MPS) method has great capability to capture interface/surface. In recent years, the multiphase flow simulation using MPS method has become one of the important directions of its developments. In this study, some key methods for multiphase flow have been introduced. The interface tension model in multiphase flow is modified to maintain the smooth of the interface and suitable for the three-phase flow. The mass transfer at immiscible liquid interface entrained by single bubble which could occur in Molten Core-Concrete Interaction (MCCI) has been investigated using this particle method. With the increase of bubble size, the height of entrainment column also increases, but the time of film rupture is slightly different. With the increase of density ratio between the two liquids, the height of entrained column decreases significantly due to the decreasing buoyancy of the denser liquid in the lighter liquid. In addition, the larger the interface tension coefficient is, the more rapidly the entrained denser liquid falls. This study validates that the MPS method has shown great performance for multiphase flow simulation. Besides, the influence of physical parameters on the mass transfer at immiscible interface has also been investigated in this study.

Observation of Acoustic Characteristic Change in bubble cloud by Ultrasonic Cavitation (초음파 캐비테이션에 의한 기포군에서의 음향특성 변화관찰)

  • Noh, Si-Cheol;Kim, Ju-Young;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.351-356
    • /
    • 2012
  • Ultrasonic cavitation is a physical phenomenon that generates and collapses microbubbles in media (mainly fluids) under conditions of strong ultrasonic irradiation. In this study, changes in the ultrasonic acoustic characteristics of bubble clouds in relation to ultrasonic irradiation were observed by the quantitative evaluation of cavitation yields. Concave-type single ultrasonic transducers with center frequencies of 500 kHz and 1.1 MHz were used to produce cavitation, and 2.25 MHz interference ultrasonic waves that would traverse any bubble clouds generated were used to analyze the cavitation. The parameters used for the evaluation of cavitation yields (changes in the center frequency, attenuation characteristics, and the propagation time of penetrating waves) were analyzed in relation to the cavitation-generating conditions (irradiation intensity, excitation signal, and center frequency). On the basis of these results, correlations between the changes in the center frequency and irradiation intensity were identified. Although the correlation coefficient was low, notable changes were observed in the center frequency under certain irradiation conditions. Attenuation trends in the interference ultrasonic waves showed high correlations with all the irradiation conditions, and it was noted that these trends were not affected by the forms of cavitation generated. No differences in the propagation time were observed among different irradiation conditions. These findings suggest that bubble yields can be quantitatively evaluated effectively by evaluating the diverse irradiation conditions and that such a quantitative evaluation could be used to study the basic cavitation phenomenon occurring in high-intensity ultrasonic wave treatment.

Evaluation of the Oxygen Transfer Parameters (α and F) of a Coarse Bubble Aeration System by Off-gas Column Test (Off-gas Column Test를 이용한 하수처리장 심층포기시스템의 산소전달 매개변수(α와 F)의 산정)

  • Kim, Chul Woong;Lee, Se Ho;Shin, Dong Rok;Lee, Ji Yong;Park, Jae Han;Ahn, Yoon Hee;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1119-1122
    • /
    • 2006
  • Aeration by using diffusers usually requires approximately 50~90% of the total electricity needed to operate WWTP (WasteWater Treatment Plant)s. Accurate evaluation of the oxygen transfer efficiency for an aeration system, and recommendation of a better alternative may help saving WWTP operational costs. Appropriate techniques and methods to achieve this purpose have not been introduced in Korea. In this study, in-process analysis was performed for a coarse bubble aeration system by the off-gas method to evaluate its applicability in Korea. To accomplish this analysis, an off-gas test, unsteady-state clean water test and steady-state off-gas column test was conducted and comparisons to other aeration systems were made. The ${\alpha}$ and the F estimated from the results of the unsteady-state clean water test and the steady-state off-gas column test were 0.61 and 0.90 respectively in a coarse bubble aeration system. The comparison of P.E tube diffusers laid out single spiral roll and ceramic dome diffusers laid out full floor coverage showed that the oxygen transfer efficiency of the coarse bubble aeration system was less than or similar to other aeration systems. But, airflow rates per unit area were 4~5 times greater than other aeration systems. In regards to the oxygen transfer efficiency for airflow rates per unit area, a retrofit to higher efficiency diffusers was urgently needed. This study showed proved that off-gas methods can apply to evaluate diffuser performances to estimate operating factors and to compare other aeration systems in Korea.