• Title/Summary/Keyword: Simulator Design

Search Result 1,807, Processing Time 0.027 seconds

Ka-Band Variable-Gain CMOS Low Noise Amplifier for Satellite Communication System (위성 통신 시스템을 위한 Ka-band 이득제어 CMOS 저잡음 증폭기)

  • Im, Hyemin;Jung, Hayeon;Lee, Jaeyong;Park, Sungkyu;Park, Changkun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.8
    • /
    • pp.959-965
    • /
    • 2019
  • In this paper, we design a low noise amplifier to support ka-band satellite communication systems using 65-nm RFCMOS process. The proposed low noise amplifier is designed with high-gain mode and low-gain mode, and is designed to control the gain according to the magnitude of the input signal. In order to reduce the power consumption, the supply voltage of the entire circuit is limited to 1 V or less. We proposed the gain control circuit that consists of the inverter structure. The 3D EM simulator is used to reduce the size of the circuit. The size of the designed amplifier including pad is $0.33mm^2$. The fabricated amplifier has a -7 dB gain control range in 3 dB bandwidth and the reflection coefficient is less than -6 dB in high gain mode and less than -15 dB in low gain mode.

Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site (산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현)

  • Jang, Mun-Seok;Lee, Eung-Hyuk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.

A Study on the Insulation Characteristics of Epoxy Composites Using Electric Field Simulation

  • Lee, Deok-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.2
    • /
    • pp.53-60
    • /
    • 2021
  • In this paper, we aimed to identify the insulation characteristics and reliability of Epoxy composites, which are widely used as insulation material for electrical & electronic components and electric appliance. To this end, it was necessary to predict variations of electric field due to the distribution of fillers that must be added by economic and mechanical factors. So, we verified the result using an electric field analysis Simulator. Furthermore, under the condtion of DC voltage application, an dielectirc breakdown test was performed according to ambient temperature changes and the distribution of fillers, and the changes were observed. Three types of specimens were manufactured by adding 0, 50 and 100[phr] filling to Epoxy resin. In all specimens, as temperature was increased, the strength of the dielectric strength was decreased. When comparing the simulation results with the actual dielectric breakdown test results, we was able to confirm the technical applicability required for Insulation design of electric appliance.

The Effect of Autonomous Driving Vehicle Positive Notification on Situation Awareness and Take-over Performance (자율주행 차량의 안전한 상태 알림이 제어권 전환 시 상황 인식과 운전 수행에 미치는 영향)

  • Ji, JaeYeong;Kim, JayHee;Han, KwangHee
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.641-652
    • /
    • 2021
  • Drivers have willing to do secondary tasks in situations deemed safe autonomous driving. I studied that positive notifications for secure areas could improve situation awareness and driving performance after TOR(Take over request) in autonomous driving. Comparing TOR alert only and monitoring alert conditions, participants in the positive notification condition showed higher situation awareness and driving performance. Also, in emotional assessment, the positive notification condition showed higher positive evaluation than other conditions. Due to Covid-19, I designed experiments separate online with driving videos in experiment 1 and offline using a driving simulator in experiment 2. This study has implications that presented a different perspective on autonomous driving notification design.

A study on imaging device sensor data QC (영상장치 센서 데이터 QC에 관한 연구)

  • Dong-Min Yun;Jae-Yeong Lee;Sung-Sik Park;Yong-Han Jeon
    • Design & Manufacturing
    • /
    • v.16 no.4
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

Development of Simulation Architecture Framework for Simulation Based Acquisition (모의기반획득을 위한 시뮬레이션 아키텍처 프레임워크 개발)

  • Cho, Kyu-Tae;Shim, Jun-Yong;Lee, Yong-Heon;Lee, Seung-Young;Kim, Sae-Hwan
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.3
    • /
    • pp.81-89
    • /
    • 2010
  • Recent modeling and simulation technology is being used in various fields. Especially in the field of military, Simulation-Based Acquisition (SBA) is recognized as a essential policy. To effectively carry out SBA, modeling and simulation techniques should be applied in the whole life-cycle for the weapon system development, and simulation architecture framework which provides easily reusable and interoperability is needed. Through reusability and interoperability, the costs of constructing the integrated collaborate environment for simulation based acquisition can be minimized. In this study, we define requirements, issues for enhancing reusability and interoperability, and propose simulation framework as a solution of the problem including structural design. Proposing simulation framework provides common functions for producing simulator as reusable units and easily changeable structure on user's purpose. In addition, we provide the result for applying simulation framework to our project.

Water film covering characteristic on horizontal fuel rod under impinging cooling condition

  • Penghui Zhang;Bowei Wang;Ronghua Chen;G.H. Su;Wenxi Tian;Suizheng Qiu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4329-4337
    • /
    • 2022
  • Jet impinging device is designed for decay heat removal on horizontal fuel rods in a low temperature heating reactor. An experimental system with a fuel rod simulator is established and experiments are performed to evaluate water film covering capacity, within 0.0287-0.0444 kg/ms mass flow rate, 0-164.1 kW/m2 heating flux and 13.8-91.4℃ feeding water temperature. An effective method to obtain the film coverage rate by infrared equipment is proposed. Water film flowing patterns are recoded and the film coverage rates at different circumference angles are measured. It is found the film coverage rate decreases with heating flux during single-phase convection, while increases after onset of nucleate boiling. Besides, film coverage rate is found affected by Marangoni effect and film accelerating effect, and surface wetting is significantly facilitated by bubble behavior. Based on the observed phenomenon and physical mechanism, dry-out depth and initial dry-out rate are proposed to evaluate film covering potential on a heating surface. A model to predict film coverage rate is proposed based on the data. The findings would have reliable guide and important implications for further evaluation and design of decay heat removal system of new reactors, and could be helpful for passive containment cooling research.

Channel Modeling and RF Performance Verification in mmWave Bands Based on NS-3 (NS-3 기반의 mmWave 대역 채널 모델링 및 RF 성능 검증)

  • Seung-Min Lee;Jun-Seok Seo;Hong-Je Jang;Myung-Ryul Choi
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.650-656
    • /
    • 2023
  • This paper implements a channel model for mmWave bands using an NS-3-based 5G system-level simulator and analyzes the reliability and validity of the implemented model through RF performance verification. The channel model for RF performance verification in the mmWave bands consider parameters such as characteristics defined in 3GPP TR 38.901, beam-forming, antenna configuration, scenarios, among others. Furthermore, the simulation results verify compliance within the ranges permitted by the 3GPP standards and verify reliability in indoor environmental scenarios by exploiting the Radio Environment Map (REM). Therefore, the channel model implemented in this study is applicable to the actual design and establishment of 5G networks, presenting a method to evaluate and validate RF performance by adjusting various parameters.

A Comparative Study of Immersive 360-degree Virtual Cycling System and Head-mounted Virtual Cycling System for Young adults

  • Wonjae Choi;Gyugeong Hwang;Seungwon Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.2
    • /
    • pp.187-195
    • /
    • 2024
  • Objective: Physical activity can promote physical and mental well-being. University students are more sedentary recently due to the increased use of computers and other technology. The aim of this study was to investigate differences between immersive 360-degree virtual cycling (IVC) and virtual cycling with head-mounted display (VCHMD) on aerobic capacity and usability in young adults. Design: A crossover study. Methods: Twenty-five university students (13 male, 12 female) participated in this study and completed 2 separate 30 min cycling sessions, such as IVC and VCHMD. In the IVC, participants rode on a stationary cycle while watching curved TV where recorded video was played. To enhance the sense of realism, auditory stimulation was given to the headset, and the gyroscope sensor was used to track the screen as the head moved. In the VCHMD, participants rode on the stationary cycle with head-mounted display, and other conditions were the same as IVC. Participants were assessed the aerobic capacity which included gas analyzer and portable near-infrared spectroscopy, and usability which included simulator sickness questionnaire and system usability scale. Results: Aerobic capacity was significantly difference in the IVC compared with the VCHMD except for the total hemoglobin of right and left rectus femoris and muslce oxygen saturation of left rectus femoris (p<0.05). Cybersickness was less in the IVC than VCHMD and usability was high in the IVC than VCHMD (p<0.05). Conclusions: The findings suggested that IVC might be beneficial exericse to improve aerobic capacity and has lower cybersickness and higher usability than VCHMD.

A study on the fire impact of Pentane outdoor storage tank (Pentane 옥외저장탱크의 화재 영향 검토에 대한 연구)

  • Eun-Ji Kim;Sung-Seek Park;Yong-Han Jeon
    • Design & Manufacturing
    • /
    • v.18 no.3
    • /
    • pp.64-70
    • /
    • 2024
  • Fire prediction, response and assessment for outdoor storage tanks are essential to disaster management because they have significant human, social and environmental impacts. Therefore, in this study, the fire situation an outdoor storage tank was simulated and the effects of fire on the radiant heat flux were analyzed concerning tank height and fire occurrence time. tank height and fire occurrence time. For this purpose, fire scenarios and specifications of the outdoor storage tank were set, and a study was carried out considered height, fire occurrence time and the operating or non-operating of a water spray system in outdoor storage tanks containing large amounts of Pentane using FDS (Fire Dynamics Simulator). As a results, the radiant heat flux was reduced by more than 50% depending on whether the water spray system was m operating or not. When the water spray system was in operation, the maximum radiant heat flux was 13.75 kW/m2 at a tank height of 14 m, and when the water spray system was not 117 operation, the maximum radiant heat flux was 25.14 kW/m2 at the same tank height. Additionally, it was found that when the water spray system was in operation, the radiant heat flux was 50% lower than when the water spray system was not in operation.