• Title/Summary/Keyword: Simulant

Search Result 124, Processing Time 0.025 seconds

Visualization of Supercritical Mixed Hydrocarbon-Fuel Droplet (혼합 탄화수소계 초임계 상태 연료의 액적 거동 가시화)

  • Song, Juyeon;Song, Wooseok;Koo, Jaye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.9
    • /
    • pp.711-716
    • /
    • 2020
  • Injection visualization of heated mixed simulant droplets based on hydrocarbon fuel was performed under supercritical state environment. Mixed simulant consisted of Decane and Methylcyclohexane with different critical pressure and critical temperature. Flows injected into the supercritical state environment created droplet by Rayleigh breakup mechanism, and the Oh number and Re number were determined to confirm the breakup area. The temperature of the mixed simulant varied from Tr=0.49 to Tr=1.34. The flow rate was maintained at 0.7 to 0.8 g/s. Droplet became shorter in breakup length as heated and into a lumped form. Second droplet was formed and when Tr=1.34, the phase was not visible in the supercritical state with local unsteady flow.

Development of KAU Mechanical Lunar Simulants and Drop Test of Lunar Landing Gears (KAU 기계적 달 복제토 개발 및 달착륙선 착륙장치의 낙하시험)

  • Yoo, Seok-Ho;Kim, Hyun-Duk;Lim, Jae Hyuk;Park, Jung-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.12
    • /
    • pp.1037-1044
    • /
    • 2014
  • In this study, we designed a drop test system considering lunar surface environment and tested landing gear of experimental lunar lander. The lunar lander would be landed at soil place for soft landing. When the lunar lander touches down, the acceleration of the lander is largely affected by mechanical characteristics of the lunar soil. Accordingly, a drop test using lunar soil is needed to verify the performance of the lunar landing gear. Because the lunar soil is not available generally, we developed a lunar simulant KAUMLS(Korea Aerospace University Mechanical Luna Simulant) based on mechanical properties of the lunar soil of NASA's LUNA PROJECT. In addition, drop tests on steel plate and dry sand are performed to evaluate impact characteristics by the surface environment.

Rheological Characteristics of Highly Concentrated Polymer Bonded Explosive Simulant: Wall Slip, Thixotropy, and Flow Instability (고농축 복합화약 시뮬란트의 유변학적 특성: 벽면 미끄러짐, 틱소트로피, 유동불안정성)

  • Lee, Sangmook;Hong, In-Kwon;Ahn, Youngjoon;Lee, Jae Wook
    • Polymer(Korea)
    • /
    • v.38 no.2
    • /
    • pp.213-219
    • /
    • 2014
  • The rheological characteristics of highly concentrated polymer bonded explosive simulant were studied. Hydroxyl terminated polybutadiene (HTPB) and polyethylene plastomer (Exact) were used as binders. Sugar and Dechlorane particles whose physical properties are similar to research department explosive (RDX) were used as fillers. When HTPB was used, diethyl hexyl adipate (DEHA or DOA) was used as a plasticizer together for some cases. Highly concentrated suspensions were mixed in a batch melt mixer (Rheomixer 600, Haake) and rheological properties were measured by plate-plate and capillary rheometers. Wall slip phenomena, thixotropy with shear hysteresis, and flow instability were investigated as shear rate and amount of fillers changed.

Estimation of Rheological Properties of Highly Concentrated Polymer Bonded Explosive Simulant by Microstructure Analysis (미세구조 해석을 통한 고농축 복합화약 시뮬란트의 유변물성 예측)

  • Lee, Sangmook;Hong, In-Kwon;Lee, Jae Wook;Shim, Jung Seob
    • Polymer(Korea)
    • /
    • v.38 no.2
    • /
    • pp.225-231
    • /
    • 2014
  • The rheological properties of highly concentrated polymer bonded explosive simulant were studied by using poly(ethylene-co-vinyl acetate) with 30 and 60% vinyl acetate (VA) content as a binder, respectively. Calcium carbonate and Dechlorane, whose physical properties are similar to resarch department explosive (RDX)'s, were used as fillers. The suspensions were mixed in a batch melt mixer and it was possible to fill 75 v% at maximum. From dynamic mechanical analysis, Dechlorane showed higher interaction with binder resins than that with calcium carbonate fillers. The effects of microstructural change on the rheological properties of the suspensions were investigated by a plate-plate rheometer with constant shear rate and constant shear stress modes, respectively. The theoretical maximum packing fraction of EVA31/Dechlorane suspension obtained from Krieger-Dougherty equation was 70 v% and it was thought that 2000 Pa was proper shear stress condition for this melt processing.

Highly Concentrated Polymer Bonded Explosive Simulant: Rheology of Exact/Dechlorane Suspension (고농축 복합화약 시뮬란트: Exact/Dechlorane 현탁계의 유변물성)

  • Lee, Sangmook;Hong, In-Kwon;Lee, Jae Wook;Lee, Keun Deuk
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.286-292
    • /
    • 2014
  • The rheology of highly concentrated polymer bonded explosive (PBX) simulant was studied. An energy material, polyethylene plastomer (Exact$^{TM}$) having similar properties to poly(BAMO-AMMO) was selected as a binder. Dechlorane with similar properties to RDX (Research Department eXplosive) was chosen as a filler. Mixing behavior in a batch melt mixer was investigated. During mixing a large amount of heat of viscous dissipation was generated and a continuous decrease in torque was observed when the filler content was above 70 v%. It was believed due to wall slip phenomena. From the SEM images, the fillers were well dispersed and the effect of mixing condition affected slightly on the dispersion. Owing to distinct shear thinning behavior of the suspensions, measuring viscosity of highly filled suspensions was possible in a high shear rate capillary rheometer though it was impossible even in a low shear rate plateplate rheometer.

Experimental Study of Lunar Rover Wheel's Motion Performance on Korean Lunar Soil Simulant (한국형 인공월면토를 이용한 달탐사 로버 휠 성능평가 실험 연구)

  • Wang, Cheng-Can;Han, Jin-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.11
    • /
    • pp.97-108
    • /
    • 2016
  • Lunar rover plays an important role in lunar exploration. Especially, performance of rover wheel related to interaction with lunar soil is of great importance when it comes to optimization of rover's configuration. In this study, in order to investigate the motion performance of lunar rover's wheel on Korean Lunar Soil Simulant (KLS-1), a single wheel testbed was developed and used to carry out a series of experiments with two kinds of wheel with grousers and without grousers which were used to perform the experiments. Wheel traction performance was evaluated by using traction parameters such as drawbar pull, torque and sinkage correlated with slip ratio. The results showed that the single wheel testbed was suitable for evaluation of the performance of wheel and rover wheel with grousers which was likely to have higher traction performance than that without grousers in Korean Lunar soil simulant. The experimental results could be utilized in verification of the optimum wheel design and effectiveness of wheel traction for Korean lunar rover.

Classification of Chemical Warfare Agents Using Thick Film Gas Sensor Array (후막 센서 어레이를 이용한 화학 작용제 분류)

  • Kwak Jun-Hyuk;Choi Nak-Jin;Bahn Tae-Hyun;Lim Yeon-Tae;Kim Jae-Chang;Huh Jeung-Soo;Lee Duk-Dong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.2 s.17
    • /
    • pp.81-87
    • /
    • 2004
  • Semiconductor thick film gas sensors based on tin oxide are fabricated and their gas response characteristics are examined for four simulant gases of chemical warfare agent (CWA)s. The sensing materials are prepared in three different sets. 1) The Pt or Pd $(1,\;2,\;3\;wt.\%)$ as catalyst is impregnated in the base material of $SnO_2$ by impregnation method.2) $Al_2O_3\;(0,\;4,\;12,\;20\;wt.\%),\;In_2O_3\;(1,\;2,\;3\;wt.\%),\;WO_3\;(1,\;2,\;3\;wt.\%),\;TiO_2\;(3,\;5,\;10\;wt.\%)$ or $SiO_2\;(3,\;5,\;10\;wt.\%)$ is added to $SnO_2$ by physical ball milling process. 3) ZnO $(1,\;2,\;3,\;4,\;5\;wt.\%)$ or $ZrO_2\;(1,\;3,\;5\;wt.\%)$ is added to $SnO_2$ by co-precipitation method. Surface morphology, particle size, and specific surface area of fabricated sensing films are performed by the SEM, XRD and BET respectively. Response characteristics are examined for simulant gases with temperature in the range 200 to $400^{\circ}C$, with different gas concentrations. These sensors have high sensitivities more than $50\%$ at 500ppb concentration for test gases and also have shown good repetition tests. Four sensing materials are selected with good sensitivity and stability and are fabricated as a sensor array A sensor array Identities among the four simulant gases through the principal component analysis (PCA). High sensitivity is acquired by using the semiconductor thick film gas sensors and four CWA gases are classified by using a sensor array through PCA.

Development of Chemical Vapor Sampler for Man-in-Simulant Test(MIST) (화생방 개인보호체계 시험평가용 화학증기 흡착 샘플러의 개발)

  • Jung, Hyunsook;Lee, Kyoo Won;Kah, Dongha;Jung, Heesoo;Ko, Chung Ah;Choi, Geun Seob;Park, Hyen Bae;Lee, Hae Wan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.387-394
    • /
    • 2015
  • We have recently developed a cost-effective and pouch-type chemical vapor sampler which consists of a selectively permeable high density polyethylene(HDPE) membrane, aluminum/nylon barrier film, and adsorbents. Since the sampler mimics the actual adsorption process that occurs when the skin is exposed to chemical vapors, it can be applied to man-in-simulant test(MIST) to determine the protective capability of individual protective ensembles for chemical warfare agents. In this study, we describe the manufacturing process of samplers and results for performance testing on MIST. Methyl salicylate(MeS) is used to simulate chemical agent vapor and the vapor sampler was used to monitor chemical concentration of MeS inside the protective suit system while worn. Values of protection factors(PF) were also analyzed to provide an indication of the protection level of the suit system evaluate by MIST. The results obtained by home-made samplers(ADD samplers) and commercially avaliable ones(Natick samplers) showed no significant differences.