• Title/Summary/Keyword: Simple standard deviation

Search Result 250, Processing Time 0.021 seconds

Adjusted EWM and MCEWM charts scheme for M statistics in start-up process (초기공정에서 M 통계량을 이용한 수정된 EWM와 MCEWM 관리도 적용기법)

  • 이희춘
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.5 no.4
    • /
    • pp.55-59
    • /
    • 2000
  • In start up process control, it may be necessary to use appropriate scheme in monitoring processes with individual observations. In these situation individual observations are periodically drawn from the process. In this paper, using modifying statistics with individual measurement, we suggest a simple technique which operating control chart for monitoring the process. And compare individual observation control procedures that are X, an exponentially weighted moving(EWM), adjusted EWM and adjusted MCEWM charts. And estimate the ARL to detection of shifts in the process mean and standard deviation using simulation.

  • PDF

A STUDY OF VERTICAL HARMONY OF ADULT CRANIOFACIAL SKELETON WITH NORMAL OCCLUTION (정상교합((정상교합) 성인(成人)의 악안면(顎顔面) 두개골격(두개골격)의 수직적(수직적) 조화(調和)에 관(關)한 연구(硏究))

  • Ahn, Eui-Young;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.12 no.2
    • /
    • pp.127-138
    • /
    • 1982
  • The present study was performed to establish the cephalometric norms and to study characteristics of craniofacial skeleton of Korean male and female with normal occlusion. The author studied and analyzed statistically vertical cephalometric measurements of the 52 adult male ranging in age from 18 to 26 years and 43 adult female ranging in age from 16 to 30 years with normal occlusion and acceptable profile. The results were as follows; 1. Cephalometric craniofacial norms and standard deviation chart were abtained about adult Korean male and female with normal occlusion. 2. Vertical dimensions of the craniofacial skeleton were larger in male than in female. 3. Lower face was more divergent in female than in male. 4. In simple correlation coefficients between vertical linear mesurements in male and female, high correlation were shown between ATFH and ALFH, PTFH and PLFH, ALFH and ALDH, PLFH and PLDH.

  • PDF

Multiphase Homodyne Laser Interferometer with Four Bucket (Four-bucket 알고리즘을 이용한 레이저 간섭계)

  • Park, Yoon-Chang;Jeong, Kyung-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.203-208
    • /
    • 1999
  • By tilting the reference mirror of Twynman-Green interferometer having a reference mirror and a moving mirror, firinge pattern composed of bright and dark parallel lines can be obtained and the fringe pattern is shifted according to the displacement of the mowing mirror. Several studies are executed for displacement measurement by detecting the intensity of the fringe with photo-diodes having small detecting area. In this study, to improve the sensitivity and robustness, the intensity of fringe is detected by using a large-area quadratic photo-diode masked with a grating panel having four kinds of binary grating having phase-difference of 0, {\pi}$/4, {\pi}$/2, 3 {\pi}$/4. The phase of the fringe is calculated with a simple 4-buckets algorithm. A experimental result shows that standard deviation of 5.653 nm is obtained comparing with a capacitive type gap sensor having nearly 1 nm accuracy.

  • PDF

Calibration of Scanner at Color Inspection of printed Texture (직물의 색상검사에서 스캐너의 편차 보정)

  • 정병묵;조지승;박무진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.383-386
    • /
    • 2002
  • It is very important to inspect color of printed texture in the textile process. To distinguish the color of the printed texture, RGB color values obtained from a scanner must be transformed to the standard colorimetric system used in the textile industry. It is XYZ color system that is defined by CIE(Commission Internationale do 1Eclairage). The mapping from RGB to XYZ color values is not simple and the scanner has even a positional deviation of RGB colors. In this paper an automatic color inspection method using a general scanning machine is presented. We used a U(neural network) model to map RGB to XYZ and compensate the positional error. In the real experiments, this inspection system shows to get very exact XYZ values from the traditional scanner regardless of the measuring position.

  • PDF

Quantitative evaluation of hepatic function for pre- and post-surgery patients using deconvolution technique in Tc-99m DISIDA SCAN (Tc-99m DISIDA SCAN에서 deconvolution 방법을 이용한 외과적 수술 전후의 간의 정량적 평가)

  • Kim, S.C.;Kim, D.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.366-369
    • /
    • 1997
  • In this study, we measured upper right, lower right, upper left region to find the optimal region which represent liver function. We found that the upper right region is optimal because of high accuracy and low standard deviation. For normal subjects all the calculated HEFs were greater than 100% and all those of abnormal ones were less than 80%. Thus HEF can be assumed to discriminate abnormal livers from normal ones. It was found that the patients with surgical operation would survive if both the pre-and the post-operative HEFs are greater than 50%. Therefore HEF method can be a good estimator for surgeon to determine the surgical operation and to evaluate remaining hepatic function after surgery as well as it is reliable and simple.

  • PDF

A Simple and Accurate Method for Determining Antioxidative Activity

  • Bae, Jin-Woo;Lee, Moo-Hong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.5
    • /
    • pp.275-278
    • /
    • 2003
  • Antioxidative activity is an important factor in inhibiting oxidative stress. The usual methods for determining antioxidative activity are time-consuming and cumbersome. They are also indirect processes that use biological material such as brain or liver microsome. This study therefore proposed a new method. Redoxpotential was determined using galvanic cell with or without the addition of various antioxidants or herbal extracts in zinc sulfate solution. The result was compared with the results from the TBA method and the peroxide value from sodium thiosulfate titration. All methods showed significant and dose-dependent enhancement of antioxidative activity by adding ascorbic acid, quercetin, ginseng, or gingko biloba extract. The result of redox potential using galvanic cell showed the smallest standard deviation and took the shortest time among the three methods. Therefore, the antioxidative potential of chemical substances and herbal extracts can be determined simply, directly and accurately in a short period of time using galvanic cell.

A Study for the Roundness Estimation (진원도 형상 추정 연구)

  • Kim, Soo-Kwang;Jun, Jae-Uhk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.38-45
    • /
    • 2011
  • The criteria for determining the elements are the minimum zone method(MZM) and the least squares method(LSM). The LSM is deterministic and simple but is limited at the measurements whose errors are significant compared with form errors. For the precise condition, minimum zone method(MZM) has been selected to determine the elements. The roundness is the fundamental problem in the evaluating form errors. In this paper, anew approach adapting the genius education concept is proposed to obtain an accurate results for the MZM and the LSM of the roundness. Its computational algorithm is studied on a set of measured sample data. To be of almost no account of the specification(the number and the standard deviation etc.) of the sanple data, the results shoqs excellent reliability and high accuracy in estimating the roundness.

Generation of Fine Droplets in a Simple Microchannel (유체 소자를 이용한 미세 액적 생성)

  • Kim, Su-Dong;Kim, Young-Won;Yoo, Jung-Yul
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2658-2663
    • /
    • 2008
  • In the present study, we designed a microfluidic flatform that generates monodisperse droplets with diameters ranging from hundreds of nanometers to several micrometers. To generate fine droplets, T-junction and flow-focusing geometry are integrated into the microfluidic channel. Relatively large aqueous droplets are generated at the upstream T-junction and transported toward the flow-focusing geometry, where each droplet is broken up into the targeted size by the action of viscous stresses. Because the droplet prior to rupture blocks the straight channel that leads to the flow-focusing geometry, it moves very slowly by the pressure difference applied between the advancing and receding regions of the moving droplet. This configuration enables very low flow rate of inner fluid and higher flow rate ratio between inner and outer fluids at the flow-focusing region. It is shown that the present microfluidic device can generate droplets with diameters about 1 micrometer size and standard deviation less than 3%.

  • PDF

Talbot Interferometry for Measuring the Focal Length of a Lens without Moiré Fringes

  • Lee, Sukmock
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.165-168
    • /
    • 2015
  • A simple method to determine the focal length of a lens using the Talbot image is presented. This method uses only one grating, requiring neither Moir$\acute{e}$ fringe analysis nor the angle between the gratings. The original Fourier transform was used to access the spectrum beyond the limitation set of the usual fast Fourier transform to determine the (de)magnification accurately enough to be used for the focal length. A set of Talbot images simulated numerically with the Fresnel diffraction integral was used to demonstrate the method. For focal lengths between 5550 mm and 5650 mm, the mean difference between the focal lengths determined from the Talbot images and the true values was 3.3 mm with the standard deviation of the difference being 3.8 mm. The true focal lengths can be recovered with an accuracy of 0.06%.

High Performance Liquid Chromatographic Determination and Content Uniformity of Aclatonium Napadisilate Preparation (고속액체 크로마토그라프법을 이용한 제제중 Aclatonium Napadisilate의 정량 및 함량균일성에 관한 연구)

  • Kim, Myun-Chong;Park, Sae-Ho;Roh, Hwoe-Suk;Kim, Yong-Ju;Huh, Jae-Doo
    • Journal of Pharmaceutical Investigation
    • /
    • v.16 no.2
    • /
    • pp.72-75
    • /
    • 1986
  • A convenient high performance liquid chromatographic method was established for the quantitative determination and content uniformity test of aclatonium napadisilate preparation. This method was more simple to make the sample solution for injection, and easy to determine the content in the preparation. Aclatonium napadisilate was chromatographed using a $Lichrosorb-NH_2$ column $(4mm\;{\times}\;25\;cm$, and acetonitrile-water mixture (83:17) as an eluent at a flow rate of 1.8 ml/min. RI-detector response was linear over a range of $0.5{\sim}2.0%$ aclatonium napadisilate under above conditions. Reproducibility studies gave relative standard deviation of 1.29%.

  • PDF