• Title/Summary/Keyword: Simple internal model control

Search Result 36, Processing Time 0.027 seconds

Control Strategy for Industrial Safety Based on Dynamic Modeling of Safety Budget-Industrial Accidents Relationship (안전예산-산재간 동적모델을 이용한 산업안전제어 전략)

  • Choi, Gi-Heung
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.1-6
    • /
    • 2011
  • This study focuses on the control strategy for industrial safety in Korea. Specifically, the effect of safety budget such as the industrial accident prevention fund on the safety performance to prevent and reduce industrial accidents is statistically examined first and modeled as a second order system. The effectiveness of such a dynamic model is also explained with a simple PI control mechanism in a feedback loop. The simulated model, however, suggests that, without improving the efficiency of the safety system, extra safety budget needed to decrease the accident rate to a level in advanced countries is far beyond the social consensus. An efficient way of reducing industrial accidents based on such a dynamic model with more internal damping but with less elastic nature in a feedback loop framework needs to be implemented.

An Improved Predictive Functional Control with Minimum-Order Observer for Speed Control of Permanent Magnet Synchronous Motor

  • Wang, Shuang;Fu, Junyong;Yang, Ying;Shi, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.272-283
    • /
    • 2017
  • In this paper, an improved predictive functional control (PFC) scheme for permanent magnet synchronous motor (PMSM) control system is proposed, on account of the standard PFC method cannot provides a satisfying disturbance rejection performance in the case of strong disturbances. The PFC-based method is first introduced in the control design of speed loop, since the good tracking and robustness properties of the PFC heavily depend on the accuracy of the internal model of the plant. However, in orthodox design of prediction model based control method, disturbances are not considered in the prediction model as well as the control design. A minimum-order observer (MOO) is introduced to estimate the disturbances, which structure is simple and can be realized at a low computational load. This paper adopted the MOO to observe the load torque, and the observations are then fed back into PFC model to rebuild it when considering the influence of perturbation. Therefore, an improved PFC strategy with torque compensation, called the PFC+MOO method, is presented. The validity of the proposed method was tested via simulation and experiments. Excellent results were obtained with respect to the speed trajectory tracking, stability, and disturbance rejection.

Design of Robust High-Speed Motion Controller with Actuator Saturation and Its Application to Precision Positioning System (구동기 포화가 있는 견실 고속 온동 제어기 설계 및 정밀 위치 결정 시스템에의 적용)

  • Park, Hyun-Raek;Kim, Bong-Keun;Shh, Il-Hong;Chung, Wan-Kyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.9
    • /
    • pp.768-776
    • /
    • 2000
  • A robust high-speed motion controller is proposed. The proposed controller consists of the proximate time optimal servomechai는 (PTOD) for high-speed motion, disturbance observer (DOB) for robustness, friction compensator, and saturation handling element, In the proposed controller, DOB basically provides the chance to apply PTOS to non-double integrator systems by drastically reducing disturbances as well as unwanted signals due to difference between real system and the double integrator model. But, in DOB-based systems, if control input is saturated due to control input PTOS and/or DOB, overall system stability cannot be guaranteed. To solve this problem, ribust stability, when the control input is saturated. Eventually, a simple saturation handling element is inserted to maintain internal stability of overall system. Also, we explain the our two saturation handling methods, Additional Saturation Element (ASE_ and Self Adjusting Saturation (SAS), are the equivalent solutions of the saturation problem to maintain internal stability. The stability and performance of the proposed controller are verified through numerical simulations and experiments using a precision linear motor system.

  • PDF

Design of Active Disturbance Rejection Control for Inductive Power Transfer Systems

  • Wang, Yanan;Dong, Lei;Liao, Xiaozhong;Ju, Xinglong;Xiao, Furong
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1434-1447
    • /
    • 2018
  • The control design of inductive power transfer (IPT) systems has attracted a lot of attention in the field of wireless power transmission. Due to the high-order resonant networks and multiple loads in IPT systems, a simplified model of an IPT system is preferred for analysis and control design, and a controller with strong robustness is required. Hence, an active disturbance rejection control (ADRC) for IPT systems is proposed in this paper. To realize the employment of ADRC, firstly a small-signal model of an LC series-compensative IPT system is derived based on generalized state-space averaging (GSSA), then the ADRC is implemented in the designed IPT system. The ADRC not only provides superior robustness to unknown internal and external disturbances, but also requires few knowledge of the IPT system. Due to the convenient realization of ADRC, the designed IPT system retains its simple structure without any additional circuits. Finally, a frequency domain analysis and experimental results have validated the effectiveness of the employed ADRC, especially its robustness in the presence of frequency drifts and other common disturbances.

Phenomenological Damping Flow Modeling and Performance Evaluation for a Continuous Damping Control Damper Using MR Fluid (MR 유체를 이용한 연속 감쇠력 가변형 댐퍼를 위한 감쇠유동의 현상학적 모델링과 성능평가)

  • Park, Jae-Woo;Jung, Young-Dae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2008
  • Recently MR CDC damper has been applied to semi-active suspension control system gradually. Compared to former hydraulic CDC damper, it has rapid time response performance as well as simple internal structure and wide range of damping force. In order to develop control logic algorithm which enables to take maximum advantage of unique characteristics of MR CDC damper, it is inevitable to perform a thorough investigation into its nonlinear performance. In many previous researches, MR fluid model was either simply assumed as Bingham Plastic, or a phenomenological model based on experiment was established instead to predict damping performance of MR CDC damper. These experimental flow model which is not based on flow analysis but intentionally built to fit damping characteristics, may lead to totally different results in case of different configuration or structure of MR CDC damper. In this study, a generalized flow formula from mathematical flow model of MR fluid for annular orifice is derived to analyze and predict damping characteristics when current is excited at piston valve.

Effect of Optical Delay on the Suppression of the Power Transient Excursion in a Combined Gain-Controlled Erbium-Doped Fiber Amplifier

  • Chung, Hee-Sang;Chang, Sun-Hyok;Park, Heuk;Lee, Hyun-Jae;Chu, Moo-Jung
    • ETRI Journal
    • /
    • v.25 no.6
    • /
    • pp.531-534
    • /
    • 2003
  • This report describes the effect of optical delay on the suppression of the power transient excursion in a combined gain-controlled erbium-doped fiber amplifier with an internal optical feedback loop (OFL). A simple homogeneous model showed that the optical delay caused a phase change in the oscillation of the surviving and laser channels, which resulted in a reduction of the overall power transient excursion. In addition to the reduction, a real system with a 1528.7-nm OFL shifted the oscillation upward or downward according to channel removal or addition, whereas another one with a 1560.9-nm OFL did not. This different transient behavior reflected a control-wavelength dependence on optical automatic gain control, where spectral-hole burning dominated over relaxation oscillation for 1528.7 nm, and vice versa for 1560.9 nm.

  • PDF

Transient-Performance-Oriented Discrete-Time Design of Resonant Controller for Three-Phase Grid-Connected Converters

  • Song, Zhanfeng;Yu, Yun;Wang, Yaqi;Ma, Xiaohui
    • Journal of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.1000-1010
    • /
    • 2019
  • The use of internal-model-based linear controller, such as resonant controller, is a well-established technique for the current control of grid-connected systems. Attractive properties for resonant controllers include their two-sequence tracking ability, the simple control structure, and the reduced computational burden. However, in the case of continuous-designed resonant controller, the transient performance is inevitably degraded at a low switching frequency. Moreover, available design methods for resonant controller is not able to realize the direct design of transient performances, and the anticipated transient performance is mainly achieved through trial and error. To address these problems, the zero-order-hold (ZOH) characteristic and inherent time delay in digital control systems are considered comprehensively in the design, and a corresponding hold-equivalent discrete model of the grid-connected converter is then established. The relationship between the placement of closed-loop poles and the corresponding transient performance is comprehensively investigated to realize the direct mapping relationship between the control gain and the transient response time. For the benefit of automatic tuning and real-time adaption, analytical expressions for controller gains are derived in detail using the required transient response time and system parameters. Simulation and experimental results demonstrate the validity of the proposed method.

A Water-Wall Model of Supercritical Once-Through Boilers Using Lumped Parameter Method

  • Go, Geon;Moon, Un-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1900-1908
    • /
    • 2014
  • This paper establishes a compact and practical model for a water-wall system comprising supercritical once-through boilers, which can be used for automatic control or simple analysis of the entire boiler-turbine system. Input and output variables of the water-wall system are defined, and balance equations are applied using a lumped parameter method. For practical purposes, the dynamic equations are developed with respect to pressure and temperature instead of density and internal energy. A comparison with results obtained using APESS, a practical thermal power plant simulator developed by Doosan Heavy Industries and Construction, is presented with respect to steady state and transient responses.

Inelastic response of multistory buildings under earthquake excitation

  • Thambiratnam, D.P.;Corderoy, H.J.B.;Gao, H.
    • Structural Engineering and Mechanics
    • /
    • v.2 no.1
    • /
    • pp.81-94
    • /
    • 1994
  • It is well recognized that structures designed to resist strong ground motions should be able to withstand substantial inelastic deformations. A simple procedure has been developed in this paper to monitor the dynamic earthquake response (time-history analysis) of both steel and concrete multistorey buildings in the inelastic range. The building is treated as a shear beam model with three degrees of freedom per floor. The entire analysis has been programmed to run on a microcomputer and can output time histories of displacements, velocities, accelerations and member internal forces at any desired location. A record of plastic hinge formation and restoration to elastic state is also provided. Such information can be used in aseismic analysis and design of multistorey buildings so as to control the damage and optimize their performance.

Characteristics Comparison of Motion Controllers through Experiments (실험을 통한 모션제어기의 특성비교)

  • Jung, Seung-Hyun;Wang, Jun;Han, Chang-Wook;Park, Jung-Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.11
    • /
    • pp.1094-1102
    • /
    • 2008
  • Through the motion control experiment using Industrial Emulator(Model 220 by ECP), the performance comparison of three kinds of controllers such as PID, RIC and LQR was carried out. It was shown that RIC has the best performance in the presence of disturbances such as step one, sinusoidal one and Coulomb friction for the rigid body. LQR using feedback state variables has the best tracking performance far the flexible body. The performance of PID controller is low compared to other controllers, but the design process is simple. The most advanced controller is LQR. In order to attenuate disturbance, an additional state observer should be used to estimate it, making more complex control system. RIC lies between PID and LQR in view of complexity of design. Even though RIC is not complicated, it has good disturbance rejection ability and less tracking error. By considering these aspects, the RIC is suggested as high precision controller to be used in motion control system.