• Title/Summary/Keyword: Simple Technique

Search Result 3,403, Processing Time 0.026 seconds

The Effect of Dose Distribution under Treatment Techniques on Cerebrospinal Irradiation (뇌 및 척수조사시 치료기법의 변화가 선량분포에 미치는 영향)

  • Lee, Seungchul;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • This study tries to evaluate the usefulness CSI treatment. Compare the standard technique and simple technique, using the volume region of a high dose of Field joints (hot spot) or low dose regions (cold Spot). In patients who agreed to this study, obtain CT image using CT simulator skull to pelvis region. Standard Technique were performed on the movement of the joint radiation field range and simple technique has set a treatment plan to secure the radiation field range and analyzed treatment planning. Under analysis standard technique occurred the area of the high dose(Hot Spot) for the area overlapping the field and simple technique showing a uniform doses. CI indices of standard technique and simple technique was 1.6~3, 1.6~1.87, CN indices was 0.32~0.53, 0.46~0.51 and HI indices was 0.11~0.33, 0.2~0.26. Therefore, adjacent to part of the dose distribution junction more equally than simple technique compared to the Standard Technique. Compare the dose distribution patterns using CI, CN, HI indices, showed a uniform dose distribution in the simple technique. so, simple technique was determined appropriate treatment the CSI.

A Comparative study of Simple Tracing with Gothic Arch Tracing (Gothic arch tracing technique에 비교된 Simple tracing에 관한 연구)

  • Bae, Bong-Jin
    • Journal of Technologic Dentistry
    • /
    • v.2 no.1
    • /
    • pp.25-27
    • /
    • 1980
  • In the process of arranging artificial teeth the simple atracing technique was shown to be more precise and convenient for general use in dental clinic than gothic arch tracing. The simple tracing technique had some advantages over other ones in that they were very useful to check protrusive, lateral and central occlusion of mandible movement, and it was very easy to transfer the oral condition and mandible movements precisely onto the articulator. Also the technique was more effective than when using wax bite in that the functional movement range has shifted to 0.2 - 0.4mm form central occlusion.

  • PDF

A simple culture technique of Rhodobacter azotoformans EBN-7 for public use: application to NH4+-N removal in shrimp aquaculture water

  • Cho, Kyoung Sook;Kim, Joong Kyun
    • Fisheries and Aquatic Sciences
    • /
    • v.25 no.10
    • /
    • pp.525-536
    • /
    • 2022
  • Photosynthetic bacteria (PSB) attract considerable interest as useful microorganisms; nevertheless, a generalized culture technique has not been previously reported owing to difficulty in their cultivation. Therefore, a simple culture technique suitable for public use was investigated. Among the PSB tested, the strain Rhodobacter azotoformans EBN-7 was the most suitable for scale-up production because it showed the highest specific growth rate (0.20 h-1) on basal medium. In scale-up cultivation (500 L), R. azotoformans EBN-7 showed 4.50 × 1010 colony-forming units mL-1 (number of viable cells), dry cell weight of 26.8 g/L, and a specific growth rate of 0.15 h-1. Cultivation using this final culture broth (as seed culture) in a 15 L simple reactor was successful, with maintenance of cell activity evident. For use as seed culture, the maximum allowable preservation period of R. azotoformans EBN-7 at 4℃ was 3 months. When R. azotoformans EBN-7 cultivated in a simple technique was applied to shrimp aquaculture water, NH4+-N was reduced from 0.61 mg/L to 0.24 mg/L (by 60.7%) in 4 days in comparison with the control. Thus, this simple culture technique using R. azotoformans EBN-7 has the potential for a good removal efficiency of NH4+-N, making seed culture easier and suitable for public use.

Roof Crush Analysis Technique Using Simple Model with Plastic Hinge Concepts (소성 힌지를 갖는 단순 보 모델을 이용한 루프 붕괴 해석 기술)

  • 강성종
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.6
    • /
    • pp.216-222
    • /
    • 1996
  • This paper presents a computational technique to predict roof crush resistance in early design stage of passenger car development. This technique use a simple F.E. model with nonlinear spring elements which represent plastic hinge behavior at weak areas. By assuming actual sections as equivalent simple sections, maximum bending moments which weak areas in major members can stand are theoretically calculated. Results from prediction of roof crush resistance are correlated well with test results.

  • PDF

Revisited Straight Line Technique for Unilateral Cleft Lip (구순구개열 환자에 있어 직선봉합법의 역할)

  • Seo, Byoung-Moo
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.11 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • The variations of cleft lip deformities imposed the difficulty to the surgical correction for them. Straight line technique for cleft lip surgery has been ignored quite long since other techniques were developed. Initially the straight line technique was introduced and widely accepted because it is simple and easy to perform during the period of no adequate anesthetics. But it was abandoned for its several shortcomings such as tighten lip, vermilion notching, anatomical distortion, and wound contractures. Recently, some groups advocated the usefulness of straight line technique which has a significant modification from its original form. Additionally the variable degree of cleft lip deformity allows simple straight line closure for those patients. Here a case of simple straight line technique was presented and discussed for its reliability and plausible results as well.

  • PDF

Dynamic Analysis of Interconnected Flexible Beams Having Large Rigid Body Rotations (대규모 강체 회전을 포함한 상호 연결된 유연한 보의 동역학적 해석)

  • Lee, K.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.8
    • /
    • pp.108-114
    • /
    • 1997
  • A simple and efficient method is presented for the dynamics of interconnected flexible beams having large rigid body rotations. A simple mass matrix is obtained by interpolating the displacements in the global inertia frame, and the elastic force is also simply computed by using linear finite element technique with the moving frame attached to the beam. For the beams connected by revolute joints, kinematic constraints and relative rotations between the beans are not required and the equations of motions are time integrated by a simple ODE technique. Numerical simulations are conducted to demonstrate the accuracy and efficiency of the present technique.

  • PDF

Employing high-temperature gas flux in a residual salt separation technique for pyroprocessing

  • Kim, Sung-Wook;Heo, Dong Hyeon;Kang, Hyun Woo;Hong, Sun-Seok;Lee, Sang-Kwon;Jeon, Min Ku;Hur, Jin-Mok;Choi, Eun-Young
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1866-1870
    • /
    • 2019
  • Residual salt separation is an essential step in pyroprocessing because its reaction products, as prepared by electrochemical unit processes, contain frozen residual electrolyte species, which are generally composed of alkali-metal chloride salts (e.g., LiCl, KCl). In this study, a simple technique that utilizes high-temperature gas flux as a driving force to melt and push out the residual salt in the reaction products was developed. This technique is simple as it only requires the use of a heating gun in combination with a gas injection system. Consequently, $LiNO_3-ZrO_2$ and $LiCl-ZrO_2$ mixtures were successfully separated by the high-temperature gas injection (separation efficiency > 93%), thereby demonstrating the viability of this simple technique for residual salt separation.

A Smart Setup for Craniospinal Irradiation

  • Peterson, Jennifer L.;Vallow, Laura A.;Kim, Siyong;Casale, Henry E.;Tzou, Katherine S.
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.230-236
    • /
    • 2013
  • Our purpose is to present a novel technique for delivering craniospinal irradiation in the supine position using a perfect match, field-in-field (FIF) intrafractional feathering, and simple forward-optimization technique. To achieve this purpose, computed tomography simulation was performed with patients in the supine position. Half-beam, blocked, opposed, lateral, cranial fields with a collimator rotation were matched to the divergence of the superior border of an upper-spinal field. Fixed field parameters were used, and the isocenter of the upper-spinal field was placed at the same source-to-axis distance (SAD), 20 cm inferior to the cranial isocenter. For a lower-spinal field, the isocenter was placed 40 cm inferior to the cranial isocenter at a constant SAD. Both gantry and couch rotations for the lower-spinal field were used to achieve perfect divergence match with the inferior border of the upper-spinal field. A FIF technique was used to feather the craniospinal and spinal-spinal junction daily by varying the match line over 2 cm. The dose throughout the target volume was modulated using the FIF simple forward optimization technique to obtain homogenous coverage. Daily, image-guided therapy was used to assure and verify the setup. This supine-position, perfect match craniospinal irradiation technique with FIF intrafractional feathering and dose modulation provides a simple and safe way to deliver treatment while minimizing dose inhomogeneity.

Aortic Valve Replacement Using Continuous Suture Technique in Patients with Aortic Valve Disease

  • Choi, Jong Bum;Kim, Jong Hun;Park, Hyun Kyu;Kim, Kyung Hwa;Kim, Min Ho;Kuh, Ja Hong;Jo, Jung Ku
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.249-255
    • /
    • 2013
  • Background: The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Materials and Methods: Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. Results: There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. Conclusion: The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.

A New Sensorless Control Scheme Using Simple Duty Feedback Technique in DC-DC Converters (DC-DC 컨버터에서 Duty Feedback 을 이용한 새로운 센서리스 제어 기법)

  • Noh Hyeong-Ju;Lee Dong-Yun;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.115-118
    • /
    • 2001
  • This paper presents a new sensorless control scheme using simple duty signal feedback technique in DC-DC converters. The proposed sensorless control scheme (DFC) has the characteristics that they show the same as operation performance of current mode control by using duty feedback technique without current sensor as well as present better dynamic response performance than conventional sensorless current mode control (SCM) in case that input source is perturbed by step change or DC input source includes the . harmonics. Also, the proposed control scheme has good noise immunity and simple control circuits since they have one feedback loop, and can be applied to all DC-DC converters. The concept and control principles of the proposed control scheme are explained in detail and the validity of the proposed control scheme is verified through several interesting simulated results.

  • PDF