• 제목/요약/키워드: SimMechanics

검색결과 145건 처리시간 0.028초

Upwind Navier-Stokes 방정식을 이용한 무딘 물체 주위의 유동장 해석 (A Numerical Analysis of High Speed Flow over Blunt Body Using Upwind Navier-Stokes Method)

  • 권창오;김상덕;송동주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1995년도 추계 학술대회논문집
    • /
    • pp.203-212
    • /
    • 1995
  • In this paper the upwind flux difference splitting Navier-Stokes method has been applied to study the perfect gas and the equilibrium chemically reacting hypersonic flow over an axisymmetric sphere-cone($5^{\circ}$) geometry. The effective gamma($\bar{r}$), enthalpy to internal energy ratio was used to couple chemistry with the fluid mechanics for equilibrium chemically reacting air. The test case condition was at altitude(30Km) and Mach number(15). The equilibrium shock thickness over the blunt body region was much thinner than that of perfect gas shock. The pressure difference between perfect gas and equilibrium gas was about $3\sim5$ percent. The skin friction coefficient and heat transfer coefficient were also calculated.

  • PDF

쇼트피이닝재와 언피닝재의 피로균열진전거동 평가 (Evaluation on Fatigue Crack Propagation Behavior of The Shot-peened and un-peened Spring Steel)

  • 박경동;류찬욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.247-254
    • /
    • 2003
  • The lightness of components required in automobile and machinery industry is requiring high strength of components. In particular manufacturing process and new materials development for solving the fatigue fracture problem attendant upon high strength of suspension of automobile are actively advanced. In this paper, the effect of compressive residual stress of spring steel(JISG SUP-9) by shot-peening on fatigue crack growth characteristics in high temperatures($100^{\circ}$, $150^{\circ}$, $180^{\circ}$) was investigated with considering fracture mechanics. So, we can obtain followings. (1)Compressive residual stress decreases in high temperature, that is, with increasing temperature. (2)The effect of compressive residual stress on fatigue crack growth behavior in high temperature increases below ${\Delta}K=17{\sim}19MPa$ (3)It was investigated by SEM that the constraint of compress residual stress for plastic zone of fatigue crack tip was decreased in high temperature as compared with room temperature.

  • PDF

Stack Effect in High-Rise Buildings: A Review

  • Mijorski, Sergey;Cammelli, Stefano
    • 국제초고층학회논문집
    • /
    • 제5권4호
    • /
    • pp.327-338
    • /
    • 2016
  • This technical paper presents a detailed review of the stack effect phenomenon and of the associated implications pertaining to the design and construction of high-rise buildings in regions of extreme climatic conditions. The present review is focused on both the classical 'chimney' effect as well as on the reverse stack effect, which are respectively related to cold and hot climates. For the purposed of the work here presented, the ASHRAE (2013) design conditions of Astana (Kazakhstan) and Riyadh (Kingdom of Saudi Arabia) were selected. A 230 m tall residential building of rectangular floor plan was numerically modelled in the context of the climatic conditions of the two abovementioned cities and a number of sensitivity analyses were performed, covering parametric changes of: temperature, façade air tightness, site wind speeds and wind directions.

전자 제어식 주차브레이크(EPB)의 성능분석 (Performance Analysis of Electronic Parking Brake)

  • 김성모;정종렬;신창우;임원식;차원석
    • 한국생산제조학회지
    • /
    • 제20권6호
    • /
    • pp.751-755
    • /
    • 2011
  • Electric Parking Brake(EPB) is the system operated by electric control actuator. It differs from the mechanical parking brake system which is operated by lever and pedal in need of human power. The EPB system is composed of DC motor, helical and differential epicyclic gear, screw, cables, and sensor. This paper describes about the EPB system mathematically and constructs a modeling of the EPB system using MATLAB/SIMULINK. Especially, SimMechanics library in SIMULINK is used to make each parts of system a module. By made modeling of the friction torque between bolt and nut. Cable tension can be maintained after the motor operating stops.

Effects of $Y_2O_3$ Addition on the Microstructure and Electrical Property of $TiO_2$-excess $BaTiO_3$

  • Kim, Jong-Han;Han, Young-Ho
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1095-1096
    • /
    • 2006
  • When $Y_2O_3$ was added to Ti-excess $BaTiO_3$ ((Ba+Y)/Ti =1), the area occupied by $Y^{3+}$ ion was confirmed by its microstructure development, electrical conductivity behavior and lattice constant. Grain growth inhibition was observed when the content of donor dopant exceeded a critical value ($x{\approx}.0.01$) in $BaTiO_3+x(0.5Y_2O_3+TiO_2)$ system. A donor-doped behavior was observed at various Y contents ($0.2\sim3.0$ mol% Y) when $Y_2O_3$ was added to $TiO_2$-excess $BaTiO_3$. As Y content was increased, (002) and (200) peaks shifted to higher angles and the lattice constant (a and c axis) decreased gradually.

  • PDF

Evaluation of the Aerodynamic Performance of A Hybrid Mesh Based Finite Volume Code

  • ZHENG, H.W.
    • International Journal of Aerospace System Engineering
    • /
    • 제2권2호
    • /
    • pp.40-43
    • /
    • 2015
  • A hybrid mesh based finite volume compressible flow code (PolySim) has been developed recently. Instead of the simple average method for the gradients of variables at each face, the volume average is applied for the calculation of the viscous flux. What is more, an improved Green Gauss method for the calculation of the gradient is also presented. These two techniques will improve both the accuracy and robustness of the code. The aerodynamic performance of this in-house cell centered code is examined by several widely-used bench-mark test cases. These cases include flows over flat plate and RAE 2822 etc. The comparisons on results between calculation and experiment are conducted. They show that the code can produce good numerical results which agree well with the corresponding experiment data.

계면활성제가 첨가된 관내 난류의 열유동 특성에 관한 고찰 (Fluid and Heat Transfer Characterization of Surfactant Turbulent Pipe Flows)

  • 신광호;윤형기;장기창;나호상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.982-987
    • /
    • 2006
  • The fluid mechanics and heat transfer of surfactant turbulent pipe flows are characterized with particular emphasis on the effects of surfactant concentration and solution temperature on drag reduction and heat transfer reduction. The test fluids are the surfactant solutions of DR-IW616 supplied by Akzo Nobel Chemical in concentration of $100{\sim}3000ppm$. The solution temperatures studied are $5^{\circ}C$ to $50^{\circ}C$. The critical values of surfactant concentration and solution temperature are clearly identified for drag reduction phenomena.

  • PDF

Nano-Indenter 측정 중 Indenting 깊이에 따른 박막의 표면 및 기판 효과에 의한 ZrN 박막의 특성연구

  • 현정민;김수인;이재훈;김홍기;심지용;문수영;윤초롱;이창우
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.177.2-177.2
    • /
    • 2015
  • Nano-mechanics 연구는 기판의 나노표면에 대하여 indenter tip을 직접 인가하여 측정함으로써 기존 분광학 연구에서는 불가능했던 박막의 기계적 특성 연구가 가능하다. 그러나 박막분석 특성상 박막의 표면, 기판 또는 하부 박막에 의한 영향으로 인해 박막의 고유한 물성특성 연구에 제약이 있다. 박막 표면에 의한 영향인 표면효과는 nano-indentation을 실행 할 때 tip의 압입으로 발생되는 표면의 스트레스로 인해 표면 변형이 나타나는 현상이다. 반면에 하부 박막과 기판에 의한 오류는 nano-indentation 실행 시 tip의 압입 깊이가 깊어질수록 하부박막 또는 기판과 가까워지기 때문에 박막 고유의 특성이 아닌 하부박막과 기판에 의한 영향이 같이 나타나는 현상이다. 이러한 오류를 최소화 하고자 많은 연구에서는 박막의 강도에 따라 nano-indentation의 실행 깊이를 박막 총 두께의 최소7%에서 최대 50%까지 삽입하는 방법을 도입하였다. 이를 기반으로 본 연구는 Zirconium nitride (ZrN) 박막의 증착된 두께 깊이만큼 nano-indentation 분석을 실행 하였으며 박막 고유의 nano-mechanics 특성을 연구 하였다. ZrN 박막은 hard coating 분야에 많이 사용되는 물질로 박막 고유의 hardness를 연구하는 것이 큰 의미가 있다. 연구 결과 모든 박막은 두께 30% 깊이 측정에서 박막 표면과 기판효과가 최소화된 박막의 물성 측정이 가능 하였고, 증착 시 질소를 0.5, 1, 2 sccm 흘려준 박막들은 총 두께 30% 깊이에서 hardness가 각각 23.2, 8.6, 18 GPa이었다. 따라서 nano-indenter 측정 시 유효한 측정 깊이에서 측정을 실시하는 것이, 박막의 물성분석에 있어서 대단히 중요함을 확인 하였다.

  • PDF

Hydrogel Ocular Inserts for the Treatment of Infectious Bovine Keratoconjunctivitis

  • Ryoo, Je-Phil;Greer, R.T.;Rosenbusch, R.F.
    • Journal of Pharmaceutical Investigation
    • /
    • 제22권3호spc1호
    • /
    • pp.35-47
    • /
    • 1992
  • Hydrogel coated ring shaped ocular inserts (containing the antibiotic, tylosin tartrate) were used in an evaluation of the effectiveness of polymeric ocular drug release devices for treating infectious bovine keratoconjunctivitis. The in vivo experiments represent the first experiments using hydrogel ocular inserts containing an antibiotic for treating infectious bovine keratoconjunctivitis. In the infection tests, ten calves. were challenged with $2.4{\times}10^8{\sim}1.6{\times}10^9$ Moraxella bovis (a bacterium) colonies per eye following two ten minute ultraviolet radiation eye preconditioning exposures. Ninety five percent of the eyes (19 of 20 eyes) were successfully infected by this method. All infected eyes were monitored for the presence of the bacteria quantitiatively, and clinical observations were made for 14 days. The test was performed by three consecutive steps: 1) inoculation with 2 ultraviolet (UV) radiations, 2) growth of bacterial colonies and 3) treatment with medicated ring-shaped devices. The first. bacteriological measurements after 2 UV exposures were performed at day 3 of the tests. At day 7 after inoculation of both eyes of a calf with M. bovis, a medicated or a non-medicated ring-shaped device was inserted into each eye of a calf. The eye receiving the non-medicated ring was taken as a control for comparison with the eye that received a medicated ring. During the next 7 day period following a medicated ring insertion, the number of bacteria in the treated eyes dropped dramatically to negligible levels (0 to 30 colony forming units/swab), while the control eyes which received a non-medicated ring still exhibited a relatively high number of bacteria ($10^3\;to\;10^6$ colony forming units/swab). The number of bacteria was significantly reduced by the antibiotic released from the medicated ocular insert.

  • PDF

Microcantilever biosensor: sensing platform, surface characterization and multiscale modeling

  • Chen, Chuin-Shan;Kuan, Shu;Chang, Tzu-Hsuan;Chou, Chia-Ching;Chang, Shu-Wei;Huang, Long-Sun
    • Smart Structures and Systems
    • /
    • 제8권1호
    • /
    • pp.17-37
    • /
    • 2011
  • The microcantilever (MCL) sensor is one of the most promising platforms for next-generation label-free biosensing applications. It outperforms conventional label-free detection methods in terms of portability and parallelization. In this paper, an overview of recent advances in our understanding of the coupling between biomolecular interactions and MCL responses is given. A dual compact optical MCL sensing platform was built to enable biosensing experiments both in gas-phase environments and in solutions. The thermal bimorph effect was found to be an effective nanomanipulator for the MCL platform calibration. The study of the alkanethiol self-assembly monolayer (SAM) chain length effect revealed that 1-octanethiol ($C_8H_{17}SH$) induced a larger deflection than that from 1-dodecanethiol ($C_{12}H_{25}SH$) in solutions. Using the clinically relevant biomarker C-reactive protein (CRP), we revealed that the analytical sensitivity of the MCL reached a diagnostic level of $1{\sim}500{\mu}g/ml$ within a 7% coefficient of variation. Using grazing incident x-ray diffractometer (GIXRD) analysis, we found that the gold surface was dominated by the (111) crystalline plane. Moreover, using X-ray photoelectron spectroscopy (XPS) analysis, we confirmed that the Au-S covalent bonds occurred in SAM adsorption whereas CRP molecular bindings occurred in protein analysis. First principles density functional theory (DFT) simulations were also used to examine biomolecular adsorption mechanisms. Multiscale modeling was then developed to connect the interactions at the molecular level with the MCL mechanical response. The alkanethiol SAM chain length effect in air was successfully predicted using the multiscale scheme.