• Title/Summary/Keyword: Silicone implant

Search Result 78, Processing Time 0.023 seconds

Wear, microleakage and plastic deformation of an implant-supported chair-side bar system

  • Mehl, Christian Johannes;Steiner, Martin;Ludwig, Klaus;Kern, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.323-328
    • /
    • 2015
  • PURPOSE. This in-vitro study was designed to evaluate retention forces, microleakage and plastic deformation of a prefabricated 2-implant bar attachment system (SFI-Bar, Cendres+$M{\acute{e}}taux$, Switzerland). MATERIALS AND METHODS. Two SFI implant-adapters were torqued with 35 Ncm into two implant analogues. Before the tube bars were finally sealed, the inner cavity of the tube bar was filled with liquid red dye to evaluate microleakage. As tube bar sealing agents three different materials were used (AGC Cem (AGC, resin based), Cervitec Plus (CP; varnish) and Gapseal (GS; silicone based). Four groups with eight specimens each were tested (GS, GS+AGC, AGC, CP). For cyclic loading, the attachment system was assembled parallel to the female counterparts in a chewing simulator. The mean retention forces of the initial and final ten cycles were statistically evaluated (ANOVA, ${\alpha}{\leq}.05$). RESULTS. All groups showed a significant loss of retention forces. Their means differed between 30-39 N initially and 22-28 N after 50,000 loading cycles. No significant statistical differences could be found between the groups at the beginning (P=.224), at the end (P=.257) or between the loss of retention forces (P=.288). Microleakage occurred initially only in some groups but after 10,000 loading cycles all groups exhibited microleakage. CONCLUSION. Long-term retention forces of the SFI-Bar remained above 20 N which can be considered clinically sufficient. The sealing agents in this study are not suitable to prevent microleakage.

Reccurent Foreign body Granuloma after Gore-tex Removal in Rhinoplasty (융비술에서 고어텍스 제거 후 발생한 재발성 이물성 육아종의 치험례)

  • Kwon, Soon Geun;You, Young Cheun;Yang, Won Yong;Park, Jun;Kang, Sang Yun
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.611-614
    • /
    • 2008
  • Purpose: Infection, foreign body reaction and decreased volume of implant are common complications after augmentation rhinoplasty with $Gore-tex^{(R)}$ implant. The author experienced two cases of recurrent foreign body granuloma in the patients who underwent $Gore-tex^{(R)}$ removal because of infection after augmentation rhinoplasty. and treated them with complete removal of$Gore-tex^{(R)}$. Methods: Case 1: A 49 year-old female visited our clinic for recurrent foreign body reaction on nasal dorsum and tip area. The patient underwent augmentation rhinoplasty with $Gore-tex^{(R)}$ 3 years ago and implant was removed due to infection 9 months ago. Excision of the granuloma was performed and a piece of foreign body suspicious to be a $Gore-tex^{(R)}$ implant debris was detected under the subcutaneous pocket. The implant fragments were removed and nasalis muscle rotation flap was performed to cover the lesion. The specimen was proved to be $Gore-tex^{(R)}$ in histological study. Case 2: A 31 year-old-male with recurrent foreign body granuloma on the nasal tip area visited our clinic. 10 years ago, the patient had augmentation rhinoplasty with silicone implant and then, he underwent revisional rhinoplasty five times including nasal implant removal, which was performed 9 months ago. The authors excised the granuloma and found a small sized foreign body suspicious to be a $Gore-tex^{(R)}$ implant debris under the granuloma. The foreign body was excised and identified to be $Gore-tex^{(R)}$ in histological study. Results: In both cases, the lesions were healed without any complications and there were no evidences of recurrence up to 6 months of follow-up. Conclusion: The $Gore-tex^{(R)}$ is known to be weak against mechanical force. These properties of $Gore-tex^{(R)}$ make it difficult to remove the implant completely. In the patient who have infection after augmentation rhinoplasty with $Gore-tex^{(R)}$, the operator should take care to perform the complete removal without remaining fragment of the implant.

A Study on the Adhesiveness between Polyurethane Sheet for Maxillofacial Prostheses and Autopolymerizing Acrylic Resin in Various Polymerization Methods (다양한 중합방법에 따른 악안면 보철용 폴리우레탄과 자가중합 레진 간의 결합력에 관한 연구)

  • Kim, Doo-Yeol;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.123-132
    • /
    • 2000
  • The field of maxillofacial prosthetics is concerned with the prosthetic reconstruction of missing head and neck tissue. Currently, facial prostheses are usually applied in cases of defects caused by the surgical removal of tumors or congenital defects. While silicone has been most widely used for the reconstruction of missing maxillofacial defects, it does not have ideal physical properties. Therefore, bonding a thin polyurethane sheet to silicone prostheses was recommended. In this case skin adhesives were used for the retention of maxillofacial prostheses. But retention of devices has always been problematic. The contributions of implants can be made to solve these problems. Implants have reduced the need for adhesive use, simplifying cleaning procedures and thus extending the life of the prostheses. For implant-retained prostheses, retentive matrix is necessary to hold attachments and/or magnets. The retentive matrix is usually fabricated with autopolymerizing acrylic resin or visible light- polymerized resin. The purpose of this study was to compare the adhesion-in-peel force of silicone adhesive to autopolymerizing acrylic resin and polyurethane sheet with two different surface textures : pumice polish only or retention groove, and three surface primers : Dow corning 1205 primer or Dow corning S-2260 primer or FactorII A-304 primer, and two polymerization methods : room temperature or dry heat oven. The t-peel bond strength of specimens was determined as described in ASTM Standard D1876-72. The results were statistically analyzed using the ANOVA test, multiple range test and t-test The results were as follows. 1. The t-peel bond strength of A-304 primer was the highest and statistically higher than that of S-2260(p<0.05). 2. The t-peel bond strength of specimens with retention groove was statistically higher than that of specimens polished with pumice(p<0.05). 3. The t-peel bond strength of specimens polymerized in dry heat oven was statistically higher than that of specimens in room temperature(p<0.01).

  • PDF

Changes in pre-osteoblast cells associated with non-precious metal cores with dental implants: Pilot test (치과용 임플란트 적용 비귀금속 코어와 관련된 전조골세포의 변화)

  • Park, Jung-Hyun;Kang, Seen-Young;Kim, Jong-Woo;Kim, Jang-Ju;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.40 no.2
    • /
    • pp.63-69
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the non-precious metal core materials used in the dental laboratory to fabricate the implant superstructure by CAD / CAM method. And to observe and compare the morphology and distribution of the osteoblasts in relation to implant osseointegration. Methods: In this study, the mandibular right first molar tooth model was selected as an international standard to produce a single core. Using this model, the impression was made with the silicone rubber, the tooth model was scanned, and a single core was designed and 5-axis milling was performed. The materials used were Cobalt-Chromium and Nickel-Chromium, and the cores for dental implant top structures were fabricated according to the procedures of the dental labs. After the fabrication, the marginal area of the core was separated and cell culture experiment was performed. The osteoblast cells used MC3T3-E1, which is currently widely used. For morphological analysis of osteoblasts, cells were posttreated and observed using CLSM (Confocal Laser Scanning Microscope) and compared. Results: The cell adhesion behavior of the specimen surface measured by CLSM was uniformly distributed in specimen A (Cobalt-Chromium) than in specimen B (Nickel-Chromium). The distribution and changes of the cells were different in the two specimens. Conclusion : It is possible to confirm that specimen A (Cobalt-Chromium) is suitable for the living body through adhesion and proliferation of osteoblasts related to implant osseointegration in the non-precious metal superstructure used after implantation. It is considered that it is preferable to use Co-Cr when fabricating the superstructure.

Aesthetic Rhinoplasty for the Improvement of the Lateral Facial Profile; Image-up Rhinoplasty (얼굴의 측면 윤곽선 개선을 위한 미용 코성형술)

  • Min Sung
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.205-213
    • /
    • 2005
  • There are several characteristics of the nose of orientals. The dorsum of nose is flat and low, the skin is thick with severe tension, the nasal tip is bulbous, the nostril is wide, and the projection of the nose is limited due to a poorly developed alar cartilage with a short columella. In order to improve these untoward characteristics of the nose of Orientals aesthetically, plain augmentation of the dorsum and tip-plasty with conventional methods has been performed by many plastic surgeons. However these conventional rhinoplasty is not enough to obtain satisfactory results when transforming into a more beautiful and aesthetically charming appearance. In order to produce the optimal nasal shape and profile, it is extremely important to consider the aesthetic surgical factors, which are; the position of the nasion, the optimal nasolabial angle(95-100 degree in Orientals), the natural exposure of infra-tip lobule with and columella, the position of the tip defining point in harmony with the dorsal profile and the smooth and natural silhouette of the lateral nasal profile as it descends into the inferior portion of the nose. From April, 2003 to August, 2004, a total of 52 patients underwent open rhinoplasty, adhering to the strict aesthetic principles considered and described priorly. Surgical approach was done through a transcolumella incision and an alar rim incision. The nasal dorsum was augmented with a silicone implant and the shape of the columella and the nasolabial angle were finessed with a silicone strut implant which was placed in between the medial crurae in a manner of a non-visible graft. The nasal tip was corrected by alar cartilage suture technique and onlay graft of shield shaped Alloderm and Gore-Tex. Author obtained the optimal nasal shape and profile aesthetically, and the results, considered satisfactory in all patients without any complications, are as follows; 1. the average increase in nasal length was 2.5 mm, 2. the average decrease in nasal width was 2.1 mm, 3. the average increase in nasal tip projection was 3.2 mm, 4. the changes of nasolabial angles were from 85.5 degree to 94.7 degree, 5. the changes of the angle between the long axis of the external naris was from 101.3 degree to 89.5 degree. In conclusion, this surgical procedure is an effective, reliable and a valuable method in improving the nasal shape, tip projection, nasolabial angle and especially, the lateral facial profile of Orientals aesthetically.

The convergence study on the use of dental impression materials (치과용 인상재의 사용 실태에 대한 융합 연구)

  • Jang, Sun-Ok;Choi, Eun-Mi;Kang, Min-Kyung;Shim, Youn-Soo;Cho, Yoon-Jeong;Oh, Sang-Hwan;Choi, Yu-Ri
    • Journal of Digital Convergence
    • /
    • v.16 no.4
    • /
    • pp.195-203
    • /
    • 2018
  • This study was conducted to investigate the types and methods of dental impression materials used in dental clinics in south Korea, the questionnaire was surveyed by a self-administered method for one dentist in a one dental clinic, the collected data were statistically analyzed using SPSS 20. The most frequently used addition silicone impression materials were used in most dental treatment. It was confirmed that the method of taking impression materials having different flow properties(light body and heavy body) was most preferred at one time, also, the implant impression taking method was the most preferred for two rubber impression materials with different flow properties, both direct and indirect. There were statistically significant differences in age and clinical experience between the methods of impression taking of casting restorations and prosthetic according to general characteristics. These results are expected to be helpful for the development of theoretical and practical work based on the basic data for impression material development and research and the preference of impression materials required for dental professional in clinical practice.

Transabdominal Augmentation of Contralateral Breast in TRAM Breast Reconstruction (횡복직근 피판을 이용한 유방 재건시 복부 절개선을 통한 반대측 유방 확대술)

  • Kim, Eun Key;Lee, Taik Jong
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.29-32
    • /
    • 2009
  • Purpose: Introduction of the mammary implant through the abdominal route has been well known since late 1960s, but the use of transabdominal route for contralateral breast augmentation in transverse rectus abdominis musculocutaneous (TRAM) flap breast reconstruction patients has not been reported in Korean literature. The authors report their experience with technical points as well as the selection of the appropriate patients. Methods: Simultaneous contralateral augmentation mammaplasty through transabdominal route was performed in 11 patients who underwent TRAM breast reconstruction from August 2003 to May 2008 with a mean follow up of 27 months. The pocket was created under direct vision: 3 subglandular, 7 subpectoral, and 1 dual plane was dissected. Eight saline and 3 silicone gel implants were used with an average volume of 165 cc. Results: There were no complications such as infection, hematoma, implant displacement, and capsular contracture. The result was well maintained throughout the follow up period. Conclusion: Transabdominal route could be recommended in selected patients for contralateral augmentation in TRAM breast reconstruction.

Modified Narrowing Corrective Rhinoplasty & Augmention Rhinoplasty in Patient with Wide Nasal Bone (폭이 넓은 코에서의 절골술과 동시에 시행한 융비술)

  • Lee, Young Jong;Hong, Sung Hee;Hong, Seung Eup
    • Archives of Plastic Surgery
    • /
    • v.32 no.1
    • /
    • pp.37-42
    • /
    • 2005
  • The human nose is located in the center of the face and it's cosmetic importance is high. The contour of the nasal dorsum and side walls play a major role in the shaping of the nose, and even a slight distortion may results in significant variance of the human facies. However, in the case of patients with wide nasal bone, augmention rhinoplasty can make nasal planes look wide, resulting in bulbous appearing noses or lateral borders of the nasal implant may be visible after the surgery making the final cosmetic results unsatisfactory. To solve such problems, from march, 1999 to march, 2004, the authors have performed augmention rhinoplasty in 36 patients. The cause of operations were as follows: flat nose 20, hump nose 5, deviated nose 4, secondary rhinoplasty 7. Paramedian osteotomy was performed at a distance that was the same as the width of the implant from the midline(5 mm + 5 mm). To prevent it from connecting to the roof at the lateral osteotomy line, intentional green stick fracture of the roof was performed. Agumentation rhinoplasty was done with either Silicone or Gortex and ear cartilage as a supplement. The follow up period was 2 weeks to 13 months with an average of 5.5 months. There were no infections and postoperative bleeding. As a result, the nose was augmented higher and narrower than before which we and the patient both found highly satisfactory.

Augmentation Mammaplasty in Women with Simple Sunken Chest (단순흉부함몰 환자에서 유방확대술)

  • Jang, Hyun;Oh, Sang-Ah;Yoon, Won-June
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.808-814
    • /
    • 2010
  • Purpose: The sunken chest deformity without breast asymmetry is not a rare condition encountered in augmentation mammaplasty. Therefore, failure to recognize the deformity and improper surgical plan will lead to a suboptimal result. The authors review the experience of breast augmentation in simple sunken chest patient based on retrospectively collected data. Methods: From January, 2008 to January, 2009, patients with simple sunken chest underwent endoscopic submuscular augmentation mammaplasty through axilla, using silicone implants. Patient demographics were queried and outcomes were assessed. Results: Eleven patients (22 breasts) were followed up for 8.2 months after surgery. Sunken chests were augmented with implant size of approximately 248.9 cc (range: 213~286 cc) and contralateral chest with 211.4 cc (range: 180~235 cc). Simultaneous camouflaging the chest wall depression with breast augmentation resulted in good aesthetic outcome. All of the patients were satisfied with the surgery. There were no complications among all patients. Conclusion: We have demonstrated proper surgical planning with precise implant selection to optimize results in patients with small breast and simple sunken chest. Even though asymmetry still remains after the operation, it is still considered as acceptable.

Infective Costochondritis after Augmentation Mammoplasty: A Rare Case Report and Review of the Literature

  • Sally Min;Jinil Choi;Kwon Joong Na;Ki Yong Hong
    • Archives of Plastic Surgery
    • /
    • v.50 no.5
    • /
    • pp.488-491
    • /
    • 2023
  • Silicone breast implant insertion is a commonly performed surgical procedure for breast augmentation or reconstruction. Among various postoperative complications, infection is one of the main causes of patient readmission and may ultimately require explantation. We report a case of infective costochondritis after augmentation mammoplasty, which has rarely been reported and is therefore difficult to diagnose. A 36-year-old female visited the clinic for persistent redness, pain, and purulent discharge around the left anteromedial chest, even after breast implant explantation. Magnetic resonance imaging showed abscess formation encircling the left fourth rib and intracartilaginous and bone marrow signal alteration at the left body of the sternum and left fourth rib. En bloc resection of partial rib and adjacent sternum were done and biopsy results confirmed infective costochondritis. Ten months postoperatively, the patient underwent chest wall reconstruction with an artificial bone graft and acellular dermal matrix. As shown in this case, early and aggressive surgical debridement of the infected costal cartilage and sternum should be performed for infective costochondritis. Furthermore, delayed chest wall reconstruction could significantly contribute to the quality of life.