• Title/Summary/Keyword: Silicoating

Search Result 21, Processing Time 0.03 seconds

Shear bond strength between gold alloy and orthodontic metal bracket using light emitting diode curing light (Light emitting diode를 이용한 광중합 시 금합금과 교정용 금속 브라켓의 전단접착강도)

  • Jung, Min-Ho;Chung, Shin-Hye;Shon, Won-Jun
    • The korean journal of orthodontics
    • /
    • v.40 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • Objective: The need to bond orthodontic brackets onto various alloys has increased because of the increasing demand for adult orthodontic treatment. This study tried to evaluate the shear bond strength between gold alloy and metal bracket using light emitting diode (LED) light curing after metal primer and silicoating surface conditioning. Methods: Half of the type III gold alloy plates were treated with sandblasting with aluminum oxide and metal primer containing 4-META. the other half were treated with silica and silane. Metal brackets were bonded with Transbond XT light curing adhesive on these plates and shear bond strength were evaluated 1 hour, 6 hours, and 24 hours later. The differences of shear bond strength between groups were evaluated with two-way ANOVA. Results: The results showed higher bond strength in the silicoating group and a tendency of bond strength increase over time. Conclusions: When using LED curing lights for metal bracket bonding to alloy surfaces, long curing time and silicoating can produce a reliable bonding strength.

AN EXPERIMENTAL STUDY ON BOND STRENGTH OF SILICOATED RESIN BONDED RESTORATION (Silicoating이 수지접합 수복물의 결합력에 미치는 영향에 관한 실험적 연구)

  • Shin, Hyeon-Soo;Han, Dong-Hu;Lee, Keun-Woo;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.101-121
    • /
    • 1989
  • This study investigated the effects of Silicoating procedure on the tensile bond strength of resin-bonded prostheses. The Rexillium III specimens were treated with electrochemical etching and Silicoating procedure, followed by thermocycling and the NNB, Pors-on 4, and Degudent-U specimens were treated with Silicoating procedure. The specimens were debonded in tension with a Tensilon machine. Also, all specimens were observed with SEM, concentration of Si elements was analyzed with EPMA, and the mode of failure was recorded. The results of this study were obtained as follows: 1. In the Rexillium III specimens, the tensile bond strength of the Silicoated specimens was higher than that of the electrochemically etched specimens, and significant differences were observed (P<0.05). 2. The tensile bond strength of electrochemically etched Rexillium III specimens, significant differences were observed between the thermocycled and nonthermocycled specimens (P<0.05), but no significant differences were observed in the Silicoated specimens (P>0.05). 3. The tensile bond strength of the Silicoated specimens decreased NNB, Pors-on 4, Rexillium III, and Degudent-U in that order named. 4. Unlike the electrochemically etched specimens, the Silicoated specimens showed gap-free metal-resin interfaces with SEM. 5. Compared to the electrochemically etched specimens, the Silicoated specimens showed higher concentration of Si elements at the metal-resin interfaces and resin cement. 6. Photographic evaluation (X2) of the fractured sites revealed mainly cohesive failures with the Silicoated specimens, and adhesive failures with the electrochemically etched specimens.

  • PDF

Effect of $Al_2O_3$ Sandblasting and Silicoating on Bond Strength of a Resin Cement to Titanium Implant ($Al_2O_3$ sandblasting과 Silicoating이 titanium과 레진시멘트의 접착강도에 미치는 영향)

  • Choi, Byung-Hwan;Ha, Jung-Yun
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.67-73
    • /
    • 2012
  • 연구 목적: 임플란트의 하부구조를 상부 구조와 연결하는 레진시멘트의 접착강도를 높이기 위한 기계적 화학적인 표면처리 방법들이 연구 되고 있다. 이 연구에서 다양한 크기의 $Al_2O_3$ sandblasting과 Silano Pen으로 표면처리한 티타늄과 레진 시멘트의 접착강도를 알아보고자 한다. 연구 방법: 12개의 티타늄(Ti-6A1-4V)시편을 디스크 형태로 제작하여 자가중합 수지에 매립하였다. 이들을 각각 6개의 군으로 나누어 $50{\mu}m$, $90{\mu}m$, $110{\mu}m$ 등 3가지 크기의 $Al_2O_3$로 sandblasting 하는 조건과 $Al_2O_3$로 sandblasting한 후 Silano Pen(Bredent, bredent GmbH &Co.KG, Senden, Germany)을 사용한 군으로 나누었다. 표면처리 한 티타늄 표면에 레진시멘트(Duolink dual syringe, Bisco, USA)으로 접착하였다. 그 후 증류수($37^{\circ}C$)에 24시간 보관 후 접착강도 실험을 시행하였고, SEM을 사용하여 표면처리 한 표면과 접착강도 실험 후 파절양상을 관찰하였다. 결과: 통계학적 분석에 따르면 Silano Pen을 사용하여 표면처리한 군들의 접착강도가 높았다(P<0.05). 결론: Silano Pen을 사용하는 것이 티타늄과 레진시멘트의 접착강도를 증가 시킨다.

A STUDY ON THE METAL SURFACE TREATMENT OF RESIN BONDED RETAINERS (산부식가공의치(酸腐植架工義齒)의 금속피착면(金屬被着面)에 관(關)한 연구(硏究))

  • Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.17-22
    • /
    • 1991
  • The purpose of this study was to evaluate the tensile bond strengths of treated alloy surfaces for resin bonded retainers. For the experiment metal surfaces of 5 alloys were teated with sandblasting, Silicoating Rocatec, and cemented with Visio-Gem. All specimens divided into two groups. The group I specimens were treated with 24-hour immersion in $37^{\circ}C$ distilled water, and group II specimens were teated with 1500 thermo-cycles from $5^{\circ}C\;to\;55^{\circ}C$. The obtained results were as follows: 1. Bond strength values showed significantly different between sandblasting group and other groups after a 24-hour immersion in $37^{\circ}C$ distilled water(P<0.05). 2. All samples were fractured during thermo-cycles for sandblasting group, and bond strength values for Silicoating and Rocatec groups showed significantly different after 1500 thermo-cycles from $5^{\circ}C\;to\;55^{\circ}C$.

  • PDF

EFFECT OF SURFACE TREATMENTS ON THE BOND STRENGTH OF DENTURE BASE RESINS TO DENTAL ALLOY (표면 처리법에 따른 치과용 합금과 열중합형 레진 간의 결합 강도에 관한 연구)

  • Lee Joo-Hee;Jung Eun-Min;Jang Bok-Sook;Chung Dong-June;Heo Seong-Joo;Han Dong-Hoo;Shim June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.344-351
    • /
    • 2002
  • The purpose of this study is to compare tensile bond strength between Cr-Co alloy and three denture base resins after surface treatment. Following the manufacturer's instructions, 180 bonded specimens were made from three denture base resins (Lucitone 199. Paladent 20. POSS resin) and three surface treatment methods (sandblasting. metal primer. silicoating) 20 samples were made in each group and a half was ther-mocycled 1000 times between $5^{\circ}C$ and $55^{\circ}C$. The tensile bond strength was measured using an Instron with 5mm/min crosshead speed. Data was analyzed with one-way ANOVA, T-test and Duncan test. The results were as follows : 1. Samples with metal primer coating had significantly high tensile bond strength than the other surface treated groups (p<.05). Significantly low tensile bond strength was shown in sand blasted groups (p<.05). 2. No significant difference was observed in metal primer coating groups before and after ther-mocycling (p>.05) 3. Tensile bond strength was decreased in silicoated samples after thermocycling (p<.05). 4. Of the surface treated groups with metal primer, Lucitone 199 had the greatest bond strength and POSS resin and Paladent 20 were followed (p<.05). 5. Of the surface treated groups with silicoating, POSS resin and Lucitone 199 had greater bond strength than Paladent 20 (p<.05).

THE EFFCT OF TIME DELAY AFTER SILICOATING ON THE BOND STRENGTH BETWEEN THE METAL AND RESIN CEMENT (Silicoating후 시간지연이 금속과 레진 시멘트 간의 접착강도에 미치는 영향)

  • Yang, Jin-Kyoung;Bae, Jeong-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.1
    • /
    • pp.1-12
    • /
    • 1995
  • For the purpose of this study, the silicoating on Ni-Cr-Be alloy surface was carried out by using the Silicoater MD. The effect of time delay after silicoating on the bond strength between the metal and resin cement was examined. The groups were divided into 4 : group 1 : Sandblasted with $250{\mu}m$ aluminium oxide, immediatly cemented group 2 : Sandblasted with $250{\mu}m$ aluminium oxide, silicoated and immediatly cemented group 3 : Sandblasted with $250{\mu}m$ aluminium oxide, silicoated and cemented after 7 days group 4 : Sandblasted with $250{\mu}m$ aluminium oxide, silicoated and coated with unfilled resin and cemented after 7 days Specimens were luted with Comspan, Superbond C&B or Panavia EX. The tensile bond strength between the metal and resin cement was measured by using the universal testing machine. The results were as follows : 1. The bond strength in groups 2, 3 and 4 was higher than that of group 1 (p<0.05). There was no statistically significant difference among the bond strength in groups 2, 3 and 4 (p>0.05). 2. In Comspan-cemented groups, there was no significant difference among the bond strength in groups 2, 3 and 4 (p<0.05). 3. In Panavia EX-cemented groups, the bond strength of group 3 was higher than that of group 2 (p<0.05) and there was no significant difference between groups 3 and 4. 4. In Superbond C&B-cemented groups, there was significant difference between groups 2 and 3 (p<0.05) and the bond strength of group 4 was higher than that of group 3 (p<0.05). 5. The highest tensile bond strength was obtained by using the Superbond C&B and no difference in the Panavia EX and Comspan. 6. The modes of bond failure were mainly cohesive failure. The method of storage and transport indicated in this study seems recommendable for laboratory and clinical use at least up to 7 days.

  • PDF

THE EFFECTS OF METAL SURFACE TREATMENT ON BOND STRENGTH BETWEEN RESIN AND METAL INTERFACE OF RESIN VENEERED CROWN (레진전장관의 금속면 처리방법 레진과 금속간 접착강도에 미치는 영향)

  • Choi Nak-Joon;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.4
    • /
    • pp.471-483
    • /
    • 1994
  • The purpose of this experiment was to determine the effects of various surface treatments on veneering resin to metal bond for Ni-Cr alloy. The metal surfaces were treated as follows, Group 1 : Ground with carborudum point and followed by silicoating Group 2 : Sandblasted with $50{\mu}m$ aluminum oxide and followed by silicoating Group 3. Sandblasted with $250{\mu}m$ aluminum oxide and followed by silicoating Group 4 : Beaded with $200{\mu}m$ retention structures and followed by silicoating Group 5 : Silicoated in as cast condition Group 6. Beaded with $200{\mu}m$ retention structures only All specimens were veneered with resin. Each group was consisted of 20 specimens. 10 specimens were storaged in $37^{\circ}C$ water for 3 days and the rest 10 specimens were thermocycled 1000 times at temperature of $5^{\circ}C\;to\;55^{\circ}C$. The effects of various surface treatments on the bond strength between resin and metal interface were studied by means of four-point flexure test. The specimens which bad been ground with carborundum point. sandblasted with $50{\mu}m$ and $250{\mu}m$ aluminum oxide. beaded with $200{\mu}m$ retention structures and not been treated were observed with SEM. The following results were obtained 1. The bond strength of groups 2, 3, 4 and 6 were higher than the that of groups 1 and 5 (p<0.05) in the case of being storaged in $37^{\circ}C$ water for 3 day and there was no statistically significant difference in bond strength among groups 2, 3, 4 and 6. and between groups 1 and 5 (p>0.05). 2. The bond strength of the case of being thermocycled decreased in the following orders : groups 2, group 4, group 3, group 6, group 1, group 5 and there was no statistically significant difference in bond strength among groups 2, 3 and 4, between groups 1 and 5 (p>0.05). 3. A statistical difference in bond strength of each group between storaged and being thermocycled was demonstrated for group 5 (p<0.05). 4. The treated surfaces of groups 2, 3 and 4 had more fine undercut than that of groups 1 and 5 with SEM.

  • PDF

The Shear Bond Strength of Resin to Electroforming Gold according to the Surface Treatment (표면처리방법에 따른 Electroforming Gold와 레진과의 전단결합강도)

  • You, Byung-Il;Chang, Mun-Suk;Yoon, Tae-Ho;Park, Ju-Mi;Park, Charn-Woon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.2
    • /
    • pp.125-136
    • /
    • 2006
  • Statement of problem. The success of the bonding between electroforming gold and resin is dependent on the surface-conditioning technique but its effective technique has net been studied widely. Purpose. The purpose of the study was to evaluate the bond strength between the electroforming gold and resin with varying the surface-conditioning technique. Materials and methods. Sixty rectangular shaped metal specimens were made and one side of each specimen were gold hard plated. The sand-blasted specimens were divided into four experimental groups with fifteen specimens in each group and were treated as follows. Group 1: Silicoating (Rocatec, 3M ESPE)+ Sinfony (3M ESPE), Group 2: SR Link+ SR Adoro (Ivoclar Vivadent), Group 3: Tin plating (Microtin, Danville Engineering)+ SR Link+ SR Adoro, Group 4: Tin plating (Micro tin, Danville Engineering)+ Silicoating (Rocatec)+ Sinfony. Shear bond strength at metal-resin interface were measured using universal testing machine. Energy Dispersive x-ray analysis was done and scanning electron microscope images were taken and observed. Results and Conclusion. The following conclusions were drawn. 1. The mean shear bond strength values in order were 11.69MPa (Group 2), 22.35MPa (Group 3), 22.40MPa (Group 1) and 27.71MPa (Group 4). There was no significant difference in Group 1, Group 3 and Group 4(P>0.05). 2. In the EDX line analysis, the Au was detected on the surface of all specimen. $SnO_2$ showed on the surface of Group 2 and $SiO_2$ was detected on the surface of Group 1. 3. Increasing of roughness by sandblasting(Group 2), formation of micro-irregularities and tin crystals by electrolytic tin plating(Group 3) and formation of surface irregularities and $SiO_2$ layer(Group 1,4) were observed in SEM photo. 4. Tin plating(Group 3) and Rocatec treatment(Group 1) showed clinically effective shear bond strength(>20MPa), but when the two surface conditioning method were used together higher bond strength were achieved.