• Title/Summary/Keyword: Sildenafil/Vardenafil

Search Result 12, Processing Time 0.032 seconds

Analysis of Sildenafil and its Analogues by LC/MS/MS (LC/MS/MS를 이용한 sildenafil 및 그 유사체 분석)

  • Myung, Seung-Woon;Park, So-Hee;Cho, Hyun-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.488-498
    • /
    • 2003
  • By LC/MS/MS, the analytical method of sildenafil and its analogues (homosildenafil, vardenafil and tadalafil) used as used medical treatment of impotence was established. electrosprary ionization (ESI) and atmospheric pressure chemical ionization (APCI) as a ionization method were applied. Several parameter were varied and the sensitivity and reproducibility were compared. In LC/ESI-MS method, capillary voltage, cone voltage, extractor, entrance and RF lens to create appropriate productr ions for multiple reaction monitoring (MRM) were variable parameter, but the formation of the other product ions except the precursor ion could not detect. And the value of entrance, collision energy, exit, corona voltage, cone voltage, extractor, RF lens, cone gas, and desolvation gas in APCI mode were varied, only the creation pattern of fragment ions by the change of RF lens value were detected, and the limit of detection was decreased due to the increase of S/N. Ten millimole ammonium formate (pH 4.8):acetonitrile=70:30 by isocratic elution in HPLC system was shown the maximum sensitivity in MS, the detection limit of sildenafil, homosildenafil, vardenafil and tadalafil obtained by ESI-MRM were 0.10, 0.025, 0.025, and $0.25{\mu}g/mL$ at S/N>5, respectively.

Simultaneous Identification/Determination System for Sildenafil, Homosildenafil, Vardenafil and Tadalafil as Adulterants in Foods (식품중 불법함유된 발기부전치료제 성분 검출을 위한 동시분석법 연구)

  • Jang, Jae-Hee;Park, Kun-Sang;Park, Hye-Kyung;Koo, Yong-Eui;Choi, Youn-Ju;Hwang, In-Kyung;Kim, Dai-Byung
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.4
    • /
    • pp.195-201
    • /
    • 2003
  • An easily available, simultaneous identification/determination procedure for sildenafil, homosildenafil, tadalafil, vardenafil in adulterated health related foods was established by using a combination of three different analytical methods; thin layer chromatography(TLC), liquied chromatography-mass spectrometry (LC/MS) and high-performance liquied chromatography (HPLC)/photo-diode-array detector. The sample solution for TLC was applied to silica gel 60 $F_{254}$ plates with ethylacetate/acetonitrile/25%ammonia (90:10:5) as a developing solvent. Spots were located under UV radiation at 254 nm and dragendolfs reagent. Mass spectra of the compounds by LC/MS were investigated with electrospray ionization (ESI) interface, under positive ion mode. The HPLC analysis was performed on a column of capcell pack $C_{18}$ (UG120, 4.6${\times}$250mm I.D. 5 ${\mu}$m)with 0.1% sodium 1-hexansulfonate (in 0.1% phosphoric acid)/acetnitrile (73:27) as a mobile phase, and effluent was minitored with a photo-diode-applied to commercial foods, Sildenafil content was inthe range of 0.4mg/g~360.9 mg/g from 7 out of 35 samples. Homosildenafil content was in the range of 2.2 mg/g~336.0 mg/g from 7 out of 35 samples. Tadalafil content was 429.3 mg/g, 9.6 mg/500 mg from 2 out of 35 samples. The procedure described here is available for the screening of sildenafil, homosildenafil, tadalafil, vardenafil.

Development of Disposable Immunosensors for Rapid Determination of Sildenafil and Vardenafil in Functional Foods

  • Vijayaraj, Kathiresan;Lee, Jun Hyuck;Kim, Hyung Sik;Chang, Seung-Cheol
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.83-88
    • /
    • 2017
  • We introduced disposable amperometric immunosensors for the detection of Sildenafil and Vardenafil (SDF/VDF) based on screen printed carbon electrodes. The developed immunosensors were used as a non-competitive sandwich-type enzyme immunoassay with a horseradish peroxidase label. The sensors were constructed on screen printed carbon electrodes by the simple electrochemical deposition of a reduced graphene oxide and chitosan (ErGO-CS) composite. To evaluate the sensing chemistry and optimize the sensor characteristics, a series of electrochemical experiments were carried out including electrochemical impedance spectroscopy, cyclic voltammetry and amperometry. The sensors showed a linear response to SDF/VDF concentrations in a range from 100 pg/mL to 300 ng/mL. The lower detection limit was calculated to be 55 pg/mL, the sensitivity was calculated to be $1.02{\mu}Ang/mL/cm^2$, and the sensor performance exhibited good reproducibility with a relative standard deviation (RSD) of 7.1%. The proposed sensing chemistry strategy and the sensor format can be used as a simple, cost-effective, and feasible method for the in-field analysis of SDF/VDF in functional or health supplement food samples.

Studies on the Analysis of Anti-impotent Drugs(II) - Rapid analysis of Sildenafil and modified Sildenafils using HPTLC

  • Choi, Hyun-Cheol;Kang, Sin-Jung;Yun, Mi-Ok;Park, Sang-Aeh;Kim, Ho-Jeong;We, Sae-Seung
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.396.1-396.1
    • /
    • 2002
  • HPTLC(High Performance Thin Layer Choromatography) method was developed for rapid and precise analysis of Sildenafil and modified Sildenafils(Vardenafil. Homosildenafil, Tadanafil). Chromatographic conditions were Optimized for simultaneous analysis of them and each specific UV spectra were obtained. The calibration curve of Sildenafil and modified Sildenafils had a linearity in the range of 1.0 ~ 56.5 $\mu$/ml at 254nm. The Limit of Detection(LOD) and the limit of Quantification(LOQ) of Sildenafil and modified Sildenafils were 0.8$\mu$/ml and 1.0$\mu$g/ml. (omitted)

  • PDF

A Study on Contents of Anti-impotence drug/drug-like compounds in Food (식품중 발기부전 치료제 및 유사물질 함량에 관한 조사연구)

  • Hong, Hae-Geun;Bang, Seon-Jae;Park, Kwang-Hee;Lee, In-Sook;Park, In-Jung;Park, Jeung-Hwa;Kim, Jong-Chan
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.89-96
    • /
    • 2007
  • To determine 8 anti-impotence drug/drug-like compounds such as sildenafil, vardenafil, tadalafil, homosildenafil, hydroxyhomosildenafil, aminotadalafil, pseudovardenafil and hongdenafil in foods, simultaneously, high performance liquid chromatography(HPLC) and liquid chromatography-mass spectrometry (LC/MS) were used. The HPLC/UV analysis was performed on a column of capcellpak $C_{18}$ with 0.1% sodium-1-hexansulfonate in 0.2M ammonium formate/acetonitrile as a mobile phase. Mass spectra of the compounds by LC/MS were investigated with SCAN mode(Mass range and Fragment voltage) and SIM(Selected Ion Monitoring) mode (Ion target and Fragment voltage). The results follow as; 1. The HPLC/UV analysis was detected from 5 out of 63 samples. The content of sildenafil was in the range of 32.80 ppm ${\sim}$ 60.13 ppm from 4 out of 5 samples. The contents of sildenafil, vardenafil, homosildenafil were in the range 47.14 ppm from 1 out of 5 samples. 2. The conformed result of LC/MS was equal of detected from 5 out of 63 samples in HPLC/UV analysis. An easily available, simultaneous determination of 8 standards in adulterated health related foods was established by using a combination of LC/MS methods.

Determining Anti-impotence drug-like compounds in Food (식품 중 발기부전치료제 및 유사물질의 분석)

  • Choi, Dongmi;Im, Mooheg;Lee, Kyungjin;Kwon, Kwangil;Jeong, Jiyoon;Park, Gunsang;Hong, Mooki;Lee, Chulwon
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.520-526
    • /
    • 2004
  • To determine 6 anti-impotence drug-like compounds such as sildenafil, vardenafil, tadalafil, homosildenafil, hydroxyhomosildenafil and hongdenafil in food, simultaneously, high performance liquid chromatography was applied. In the case of solid sample, it was extracted in organic solvents after homogenizing with mortar and pestle. Whereas liquid sample was just diluted in water and then extracted in organic solvents. Maximum lengths of UV for targets have been identified on photodiode array spectra. As results, vardenafil, hongdenafil, hydroxyhomosildenafil, sildenafil, homosildenafil, and tadalafil were eluted in order using $C_{18}$ column in acetonitrile containing phosphoric acid as the mobile phase. The maximum wavelength (${\lambda}_{max}$) was 216 nm for vardenafil, 233 and 282 nm for hongdenafil, 222 and 293 nm for hydroxyhomosildenafil, sildenafil and homosildenafil, and 284 nm for tadalafil. The overall recoveries were ranged from 95% to 109% and the limit of detection was about 0.04 mg/kg at signal/noise>3. Levels of targets in the selected food samples were 1.7 (hongdenafil) ~ 63 (tadalafil) mg/one dose.

Studies on the Analysis of Anti-impotent Drugs

  • Kang, Chan-Sun;Choi, Bo-Kyung;Kim, Hye-Soo;Choi, Myoeng-Sin;Hong, Chong-Hui;Ko, Yong-Seok;Kim, Sang-Hyun;Jang, Seung-Jae
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.397.2-397.2
    • /
    • 2002
  • Sildenafil citrate(SC. Viagra(equation omitted)) is the oral treatment for erectile dysfunction. Vardenafil hydrochloride. tadalafil and modified sildenafil have anti-impotent effect and have possibility to be used illegally. The aim of this study was to set up simultaneous determination method of anti-impotent drugs using TLC and HPLC. The anti-impotent drugs were extracted with 50% methanol and then diluted with mobile phase for HPLC and also extracted with developing solvents as sample solutions for TLC. (omitted)

  • PDF

Simultaneous Determination of Synthetic Phosphodiesterase-5 Inhibitors in Dietary Supplements by Liquid Chromatography-High Resolution/Mass Spectrometry

  • Kim, So-Hee;Kim, Ho-Jun;Son, Jung-Hyun;Jeon, Byoung-Wook;Jeong, Eun-Sook;Cha, Eun-Ju;Lee, Jae-Ick
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.50-53
    • /
    • 2012
  • After success of sildenafil for the treatment of erectile dysfunction, a large number of its analogues have been approved from FDA. Recently, the illegal dietary supplements which include sildenafil, vardenafil, tadalafil, or analogues of these drugs as ingredient have been widely distributed. Therefore, the determination of the residue of synthetic phosphodiesterase- 5 (PDE-5) inhibitors in dietary supplements is highly required due to indiscriminate and unintentional overdose caused nausea, chest pains, fainting and irregular heartbeat. In this paper, we report a rapid and sensitive analytical method for the simultaneous determination of nine phosphodiesterase-5 inhibitors by liquid chromatography-high resolution mass spectrometry. The present method was found to be accurate and reproducible with 40 ${\mu}g$/g of the limit of quantification for the nine PDE-5 inhibitors. The developed method can be successfully applied to the analysis of the seven illegal dietary supplements.

Identification and evaluation of fragmentation pathways of PDE-5 inhibitor analogues using LC-QTOF-MS (LC-QTOF-MS를 이용한 발기부전치료제 유사물질의 fragmentation pathway 분석)

  • Do, Jung-Ah;Noh, Eunyoung;Yoon, Soon-Byung;Park, Hyoung-Joon;Cho, Sooyeul;Park, Sung-Kwan;Yoon, Chang-Yong
    • Analytical Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.278-287
    • /
    • 2015
  • Phosphodiesterase type 5 inhibitors (PDE-5 inhibitors) are used in the treatment of erectile dysfunction. In recent years, a number of reports have been conducted on dietary supplements contaminated with PDE-5 analogues. In this study, 58 analogues of PDE-5 inhibitors were sorted into five groups: tadalafil, sildenafil, hongdenafil, vardenafil, and other analogues. These analogues were then evaluated using a liquid chromatography-quadrupole-time of flight mass spectrometry (LC-QTOF-MS) electrospray ionization mass method. Each compound has a unique fragmentation ion, which can be easily analyzed qualitatively. The fragmentation pathways of the analogues were elucidated based on the QTOF-MS and MS/MS data. Common ions were confirmed for each group by analyzing the structural characteristics and fragmentation pathways. Specifically, common ions were observed at m/z 169.08 and 135.04 (tadalafil analogues), m/z 311.15 and 283.12 (sildenafil analogues and hongdenafil analogues), and m/z 312.16 and 151.09 (vardenafil analogues). The advantage of this method is that the structure of unknown components can be determined by interpreting the product ions. Hence, the developed method can be used for the identification of unknown compounds. Fragmentation pathways may also aid in the detection and identification of PDE-5 inhibitor analogues.

Proficiency test for analyzing illegal compounds in food (식품 중 부정유해물질의 분석 능력평가)

  • Chang, Moonik;Yoon, Taehyung;Hong, Mooki;Choi, Dongmi
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.78-83
    • /
    • 2007
  • To perform proficiency test for determining anti-impotence drug-like compounds in food, interlaboratory test has been done. Targets were 6 such as sildenafil, tadalafil, vardenafil, homosildenafil, hydroxy-homosildenafil and pseudo-vardenafilI. Total 13 institutes were participated and all is in charging of food analysis. To do double blind test, the reference materials were made as 13 different ginseng drink samples and each sample had random 3 targets. By the official method for anti-impotence drug-like compounds in food code, sample was just diluted in water, extracted in organic solvents, determined by HPLC/UV and then confirmed by LC/MS. The analytical duration was 60 days after receiving sample. Ten out of 13 institutes were satisfied by evaluation of Z-score and RSZ according to the regulation for managing analytical quality assurance.