• Title/Summary/Keyword: Significance of Pulse

Search Result 96, Processing Time 0.03 seconds

A study on the pulse wave factor according to BMI and period of sterility on female (난임 여성의 체질량지수(BMI), 불임기간에 따른 맥파 연구)

  • Kim, Gyeong-Cheol;Kim, Yi-Soon
    • Korean Journal of Oriental Medicine
    • /
    • v.18 no.2
    • /
    • pp.139-149
    • /
    • 2012
  • Objectives : This is the study to understand of the pulse wave factor according to BMI and period of sterility on female, and to confirm the relationship of pulse wave factor among left and right inch, bar and cubit. Methods : The Questions and measurement of the pulse wave were operated with subjects(76 sterile females using on public health center). The measurement of the pulse wave was operated in 6 part of left and right inch, bar and cubit. The pulse wave was prior measured in part of left bar (i.e. interior pulsation part of radial process styloides in left hand), and next was measured in part of left inch and bar. And the pulse wave was operated samely in part of right inch, bar and cubit. Results : The results were as follows. The pulse energy of 6 part of left and right inch, bar and cubit was showed statistical significance and decreased in order of left inch, right inch, left cubit, right cubit, left inch, right bar. The left and right inch and cubit were showed numerical value of normal range, but left and right bar were showed lower pulse eneregy than normal range. Also left and right cubit were showed lower than left and right inch, and higher than left and right bar. In BMI, The pulse energy of left and right inch, cubit and the average of right hand was not showed statistical significance in the range of low-weight, normal, over-weight and obesity. But in the left and right bar and the average of left hand, the pulse energy of over-weight and obesity group were showed significantly higher than low-weight group. And the pulse wave factor was divided the pattern of h1 showing high numerical value in inch (Ap, As, Aw) and the pattern of Wm showing high numerical value in bar and cubit (RAI, Ad) Conclusions : The low pulse energy of bar was significant observation on the setting of oriental medical diagnostic index on sterilitas. Also, in the numerical value pattern of diverse pulse wave factor, it was divided the pattern of high numerical value in inch and the pattern of high numerical value in bar and cubit. On this, we think that the studies need in the future.

Clinical Assessment of Warm Acupuncture Therapy System Using HF Time-varying Magnetic Field (고주파 자기장을 이용한 온침 치료시스템의 임상 평가)

  • Lee, Su-Yong;Byeon, Sang-Jun;Choi, Ye-Bin;Kim, Jin-Ju;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.33 no.4
    • /
    • pp.213-220
    • /
    • 2016
  • Objectives : The aim of this paper is to develop acupuncture needle heating system by utilizing the new method which uses high frequency(HF) time-varying magnetic field. Also, it is possible to make an assessment for reliability and clinical significance of the system. Methods : We designed the system with solenoid coils for generation of HF time-varying magnetic field that oscillates at 150 kHz. Acupuncture needles are quickly magnetized and heated by 150 kHz. We assessed clinical significance of system, such as body temperature, pressure pulse waveform. Results : Temperature of acupuncture needle increased up to 60 degree. In the result for clinical significance of system, in case of manual acupuncture stimulation(MAS), body temperature change was $0.373^{\circ}C{\pm}0.224$(p<0.05), rate of pulse energy change increased about 7.6%. In case of warm acupuncture stimulation(WAS), body temperature change was $0.645^{\circ}C{\pm}0.281$(p<0.05), rate of pulse energy change remarkably increased about 35.9%. Conclusions : We confirm that the system is able to be applied clinically to various warm acupuncture needle therapy in the area of oriental medicine.

The Study on the Web-Based Analysis System of Oriental Pulse Waveform (웹기반 임상 맥파 데이터 분석 시스템에 관한 연구)

  • Lee, Jun-Young
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.9-12
    • /
    • 2012
  • This paper analyzes a web-based clinical management system and conducts research on the pulse. Pulse analysis and the clinical study management system proposed by the web-based research holds significance in that it improves the objectivity and accuracy of pulse diagnosis. In particular, exact data must be analyzed through the clinical interpretation of these studies. Eventually oriental pulse standardization work will be continuously sustained. The findings of this study will help achieve remote diagnosis and consultation and updating of database. Research must be expanded to the development of telemedicine technology to create u-Health that will lead this present era.

Study on the pulse current control of the inverter TIG welder (인버터 TIG 용접기의 펄스전류 제어에 관한 연구)

  • 서문준;김규식;원충연;민명식;최규하;목형수
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.154-157
    • /
    • 1998
  • In this paper, the inverter TIG(Tungsten Inert Gas) welding system with high power efficiency by means of pulse current control of welding process is presented. In TIG welding, pulse current control is utilized in order to attain less apatter and high welding performance. The four factors which determine the welding performance of the pulse current are frequency, base current, peak current, and peak current duty current, and peak current duty ratio. In this paper, we analyze these factors should be controlled to achieve minimum power input. To demonstrate the practical significance of our results, we present some experimental results as well as simulation results.

  • PDF

Characteristics of Lightweight Concrete and Their Application in Structures

  • ;R.N. Swamy
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.E
    • /
    • pp.60-69
    • /
    • 1992
  • The research significance of the paper is to identify the major properties of synthetic lightweight concrete that are affected by ASR expansion and to determine the extent and magnitude of the loss in these properties. Emphasis is also given to the use of non-destructive testing techniques ; Such as dynamic modulus of elasticity and ultrasonic pulse velocity, to examine whether these methods could be used to identify the initiation of expansion and the internal structural damage caused by ASR.

  • PDF

Study on the Basic Pulse Indicators for Pattern Identifications in Stroke (중풍환자의 변증에 사용되는 맥진 지표에 관한 연구)

  • Lee, Jung-Sup;Ko, Mi-Mi;Kang, Byoung-Kab;Kim, So-Yeon;Kim, Jeong-Cheol;Oh, Dal-Seok;Lee, In;Kim, Yun-Sik;Bang, Ok-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.964-968
    • /
    • 2009
  • The purpose of this study is to select the major pulse indicators and evaluate their significance in discriminating the subtypes of Pattern Identifications (PI) from stroke patients. Decision tree analysis was carried out using clinical data collected from 835 stroke patients with the same subtypes diagnosed identically by two experts with more than 3 year clinical experiences. Among the 10 pulse indicators, 6 major pulse indicators (slow, rapid, strong, weak, slippery, and fine pulse) were selected by decision tree analysis. The accumulated distributions of six pulse indicators in each PI showed that strong was major pulse indicator in Fire-Heat pattern, slippery in Dampness Phlegm pattern, weak in Qi Deficiency pattern. But there were two major combinations in Yin deficiency pattern, weak or fine with rapid pulse and weak or fine without rapid pulse. Therefore, it is suggested that 6 pulse indicators can be used for discrimination of PI in stroke patients, though the combination studies between these pulse indicators and the other PI indicators are left for further study.

Evaluation of Significance on the Brachial-ankle arterial pulse wave velocity And Cerebral Artery Vascular Stenosis (상완-발목 맥파 전달 속도와 뇌동맥 혈관 협착과의 유의성 평가)

  • Kim, Ji-Yul;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.873-878
    • /
    • 2019
  • Cerebrovascular disease is one of the three major causes of death in Korea. Since these diseases are associated with atherosclerosis, the diagnosis of atherosclerotic factors should be presented. In this study, we evaluated the relationship between brachial-ankle arterial pulse wave velocity, cerebral artery vascular stenosis, blood pressure, obesity, and abdominal obesity by age group. The significance of cerebral artery stenosis and age group. The risk factors of atherosclerosis, such as blood pressure, obesity, and abdominal obesity, were significant in all age groups. When the pulse wave velocity of the brachial-ankle artery was increased, the cerebral artery stenosis was distributed in 57.3% of the total test subjects. If the arterial stiffness is suspected during the measurement of the pulse wave velocity of the brachial ankle artery, We recommend suspected vascular stenosis and perform a cerebral artery angiography. It is suggested that the data will be used as a baseline data for similar studies after evaluating the significance of blood pressure, obesity, and abdominal obesity as risk factors of atherosclerosis.

Effects of Venesection at the Sybsun-points on Blood Pressure and Body Temperature and Pulse Rate in Humans (남녀 대학생에서 십선혈(十宣穴) 사혈(瀉血)이 혈압, 체온 및 맥박수에 미치는 영향)

  • Lee, Dong-Gun;Jeong, Won-Je;Lee, Hyun-Jin;Cho, Hyun-Seok;Kim, Kyung-Ho;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.25 no.4
    • /
    • pp.51-58
    • /
    • 2008
  • Objectives : Sypsun-points are located at the tips of all fingers, 0.1 chon(寸) from the finger nails, totaling 10 points on both hands. These points have been used for emergency care, fainting, epilepsy, cerebrovascular accidents, hypertension, unconsciousness, high fever etc. in oriental medicine. The most common technique is bleeding with a needle at these points. We investigated whether Venesection at the Sybsun-points has effects on blood pressure and body temperature and pulse rate in humans aged from 20 to 30 who had no specific past history and whose vital signs are in normal range. Methods : 67 persons were studied from March to June 2008. They were composed of Sample group(n=36) and Normal group(n=31). Both two groups kept a steady state an hour before venesection. In both group, we checked blood pressure and body temperature and pulse rates 6 times( 30min. before and just before treatment, and just after, 30, 60, 90min after treatment). All study environments were same between sample and normal group. But only, normal group didn't carry out venesection at the Sybsun-points. Results : In a comparison of before and after venesection at the Sybsun-points, any Statistical significance was not evaluated. Though pulse rate in sample group was significantly decreased after venesection(p<0.05), it has no statistical significance because normal group's pulse rate was also significantly decreased and between two groups had no statistical difference. Conclusions : Though further study is needed, our findings suggest that venesection at the Sybsun-points has no significant effect on blood pressure and body temperature, and pulse rate in humans who had no specific past history and whose vital signs are in normal range. Also in that case, we may know that pain and tension result from venesection at the Sybsun-points have no significant effect on blood pressure and body temperature and pulse rate.

  • PDF

A Study on Pulse Pattern Using Ultrasonic Device (초음파기기를 이용한 맥상(脈象) 연구)

  • Kim, Hee Young;Park, Jeongbin;Keum, Yujeong;Yeo, Inkeum;Eom, Dongmyung;Song, Jichung
    • Journal of Korean Medical classics
    • /
    • v.34 no.2
    • /
    • pp.85-94
    • /
    • 2021
  • Objectives : Pulse diagnosis is one of the main diagnostic methods of Korean Medicine that understands the patient's condition and illness by reading changes in the patient's pulse, which is described in terms of pulse condition While they are described in detail in medical texts, it is difficult to grasp their true nature, as the written descriptions fail to do justice to the experience of pulse taking it tries to convey. As a way to approach pulse condition the effect of the body's tension on the radial vein was measured using an ultrasonic device, after which the measured changes and how they could be reflected in pulse condition were studied. In other words, changes in the radial vein following induced tension were analyzed. Methods : 1) The thickness of the subject's radial vein was measured using a linear probe of an ultrasonic device[LOGIQ 5 Basic, GE, USA]. 2) Fatigue level was increased through artificial stimulation using the Gripmeter[ks-301, Lavisen, Korea]. 3) Thickness of the radial vein post tension induction was measured. 4) The results were analyzed with the Tukey test or paired t-test as post hoc tests. Results : Thickness of the radial vein of the subject pre- and post- Gripmeter stimulation decreased with significance. Conclusions : Constriction of the radial vein that happened after tension induction could be linked to the Tight Pulse[緊脈] that is related to patterns of contraction and pulling.

A Investigation into Arrhythmia between East and West medicine (부정맥(不整脈)에 대(對)한 동서의학적(東西醫學的) 문헌고찰(文獻考察))

  • Jeong, Gwang-Sik;Kim, Young-Guen;Kwon, Jung-Nam;Kim, Kyoung-Min
    • The Journal of Internal Korean Medicine
    • /
    • v.21 no.5
    • /
    • pp.747-763
    • /
    • 2000
  • through a literal study upon Arrhythmia between east and west medicine, the results were as follows 1. Arrhythmia is not only irregular cardiac beat but disorder of cardiac impulse making and conduction disturbance. it means almost irregularity of interval between two beat 2. In the east medicine, arrhythmia is represented various category as palpitation, continuous palpitation, dizziness, consumption which give the first consideration by the accompanied symptoms. A separate way in a diagnostics it become a base of diagnosis of diseases and decision of prognosis by the examination of pulse 3. In the west medicine, Arrhythmia is classified as disorder of heart rate, rhythm, conduction disturbance or tachycardia, bradycardia and it is concomitant with fatigue, palpitation, dyspnoea, syncope, chest discomfort 4. The diagnostic study of pulse condition which represent arrhythmia was started from $\mathbb{<}$Nae-Kyung$\mathbb{>}$ and it was revealed as pulse condition of rapid pulse, slow pulse, swift pulse, running pulse, knotted pulse, intermittent pulse etc. Out of them running pulse, knotted pulse, intermittent pulse which obviously are concomitant with irregularity of interval are clinically meaningful in a conditions of disease and decision of prognosis. and the significance of these pulse condition are transformed through the changes of the times 5. According to cause of disease it is classified by Arrhythmia(running pulse, knotted pulse, intermittent pulse) due to heat, cold, phlegm, deficiency(or insufficiency) and There are three categories of etiological factor that is, endogenous, exogenous and non-exo-endogenous factor. the endogenous factor is insufficiency of the heart Ki, deficiency of both Ki and blood, intemal stagnation of phlegm and fluid, stagnation of seven emotions. the exogenous factor is caused by stagnation of Ki and blood by six exogenous pathogenic factor and the non-exo-endgenous factors are improper diet, overstrain, traumatic injury. A cause of arrhythmia in western medicine are a organic and pathological change of the heart itself and malfunction of the autonomic nervous system.

  • PDF