• Title/Summary/Keyword: Signal-to-Noise(S/N) Ratio

Search Result 187, Processing Time 0.029 seconds

A Study on the Data Analysis Systems in Deep Level Transient Spectroscopy (DLTS 시스템에서의 신호처리에 관한 연구)

  • Lim, H.;Lee, W.Y.;Choi, Y.I.;Chung, S.K.;Kim, H.N.
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.1
    • /
    • pp.120-125
    • /
    • 1986
  • Data analysis methods in lock-in amplifier based DLTS systems were discussed with regards to the signal-to-noise ratio and improvement of resolution of DLTS spectrum. The DLTS system based on wideband two-phase lock-in amplifier is shown to be the most preferabe for the studies in deep levels of low concentration. A single-temperature scanning DLTS methods in lock-in amplifier based system with the improved sensitivity is proposed. The method is tested on the characterization of deep levels in n-GaAs.

  • PDF

Dose Reduction Method for Chest CT using a Combination of Examination Condition Control and Iterative Reconstruction (검사 조건 제어와 반복 재구성의 조합을 이용한 흉부 CT의 선량 저감화 방안)

  • Sang-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1025-1031
    • /
    • 2023
  • We aimed to evaluate the radiation dose and image quality by changing the Scout view voltage in low-dose chest CT (LDCT) and applying scan parameters such as AEC (auto exposure control) and ASIR (adaptive statistical iterative reconstruction) to find the optimal protocol. Scout view voltage was varied at 80, 100, 120, 140 kV and after measuring the dose 5 times using the existing low-dose chest CT protocol, the appropriate kV was selected for the study using the Dose report provided by the equipment. After taking a basic LDCT shot at 120 kV, 30 mAs, ASIR 50% was applied to this condition. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed by measuring Background noise (B/N). For dose comparison, CTDIvol and DLP provided by the equipment were compared and analyzed using the formulas. The results indicated that the protocol of scout 140 + LDCT + ASIR 50 + AEC reduced radiation exposure and improved image quality compared to traditional LDCT, providing an optimal protocol. As demonstrated in the experiment, LDCT screenings for asymptomatic normal individuals are crucial, as they involve concerns over excessive radiation exposure per examination. Therefore, applying appropriate parameters is important, and it is expected to contribute positively to the public health in future LDCT based health screenings.

Effect of Cationization Agent Concentration on Glycan Detection Using MALDI TOF-MS

  • Kim, Inyoung;Shin, Dongwon;Paek, Jihyun;Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • v.8 no.1
    • /
    • pp.14-17
    • /
    • 2017
  • The effect of cationization agent concentration on glycan detection via matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was investigated using $Na^+$ ions in the form of NaCl as the cationization agent. NaCl solution concentrations ranging from 1 mM to 1 M were investigated. Glycans from ovalbumin were mixed with the cationization agent solution and the 2,5-dihydroxybenzoic acid (2,5-DHB) matrix solution in a volume ratio of 1:1:1. The resulting mixture was loaded onto the MALDI plate. Two MALDI-TOF MS instruments (Voyager DE-STR MALDI-TOF MS and Tinkerbell RT MALDI-TOF MS) were used for detection of glycans. The best detection, in terms of the number of identified glycans, the peak intensity, and the signal-to-noise (S/N) ratio, was obtained with NaCl concentrations of 0.01-0.1 M for both MALDI-TOF MS instruments.

A Study on Digital Frequency Discriminator (DFD) Operating in E, F, and G Band (E, F, G 밴드 디지털 주파수 측정기에 대한 연구)

  • Yu, Yun-Seop;Kim, Eun-Sil;Lee, Chan-Ho;Ahn, Hyeon-Kwan;Yang, Hong-Sun;Lim, Joong-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.149-150
    • /
    • 2006
  • In this paper, design, simulation, fabrication method, and measured results of a digital frequency discriminator(DFD) operating in E, F, and G band are introduced. We describe the direct conversion scheme(DCS) with microwave integrated-circuit(MIC) developed for the small-area and high-speed system. When the input signal is the pulse with a pulse width of 100 ns, accuracy of frequencies measured by the DFD has 1.335 MHz RMS at no noise and 2.64 MHz RMS at signal-to-noise(S/N) ratio within 3 dB in E, F, and G band, which nearly satisfy the specification of 2.5 MHz RMS.

  • PDF

Straylight analysis for preliminary filter and baffle design for New Generation GOCI

  • Oh, Eun-Song;Ahn, Ki-Beom;Jung, Kil-Jae;Ryu, Dong-Ok;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.25.4-26
    • /
    • 2010
  • We present a three-mirror anastigmat(TMA) optical system for New Generation GOCI. In order to reduce the ghost optimized filter and baffle. By using carefully chosen antireflective coating and tilted filter angle, we fulfilled the design SNR requirement of 1500. We then designed a new entrance baffle and an internal baffle capable of producing the ghost ratio better than 0.01% of the nominal signal. The entrance baffle limits FOV to $0.75^{\circ}$ (E/W) $\times$ $0.60^{\circ}$ (S/N), and prevents the system from strong sun illumination, and the internal baffle prevents stray and scattered ray from entering into the telescope cavity. From these filter and baffle design, we confirmed that the instrument signal to noise ratio can be met with the current conceptual opto-mechanical design.

  • PDF

Construction and Functional Tests of Fuel Assembly Mechanical Characterization Test Facility (핵연료집합체 기계적특성 시험시설 구축과 기능시험)

  • Lee, Kang-Hee;Kang, Heung-Seok;Yoon, Kyung-Ho;Yang, Jae-Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2016
  • Fuel assembly's mechanical characterization test facility (FAMeCT) in KAERI was constructed with upgraded functional features such as increased loading capacity, underwater vibration testing and severe earthquake simulation for extended fuel design guideline. This facility is designed and developed to provide out-pile fuel data for accident analysis model and fuel licensing. Functional tests of FAMeCT were performed to confirm functionality, structural integrity, and validity of newly-built fuel assembly mechanical test facility. Test program includes signal check of data acquisition system, load delivering capacity using real-sized fuel assemblies and a standard loading cylindrical rigid specimen. Fuel assembly's lateral bending test was carried out up to 30 mm of pull-out displacement. Limit case axial compression loading test up to 33 kN was performed to check structural integrity of UCPS (Upper Core Plate Simulator) support frame. Test results show that all test equipment and measurement system have acceptable range of alignment, signal to noise ratio, load carrying capacity limit without loss of integrity. This paper introduces newly constructed fuel assembly's mechanical test facility and summarizes results of functional test for the mechanical test equipment and data acquisition system.

Parameter Design and Analysis for Aluminum Resistance Spot Welding

  • Cho, Yong-Joon;Li, Wei;Hu, S. Jack
    • Journal of Welding and Joining
    • /
    • v.20 no.2
    • /
    • pp.102-108
    • /
    • 2002
  • Resistance spot welding of aluminum alloys is based upon Joule heating of the components by passing a large current in a short duration. Since aluminum alloys have the potential to replace steels fur automobile body assemblies, it is important to study the process robustness of aluminum spot welding process. In order to evaluate the effects of process parameters on the weld quality, major process variables and abnormal process conditions were selected and analyzed. A newly developed two-stage, sliding-level experiment was adopted fur effective parameter design and analysis. Suitable ranges of welding current and button diameters were obtained through the experiment. The effects of the factors and their levels on the variation of acceptable welding current were considered in terms of main effects. From the results, it is concluded that any abnormal process condition decreases the suitable current range in the weld lobe curve. Pareto analysis of variance was also introduced to estimate the significant factors on the signal-to-noise (S/N) ratio. Among the six factors studied, fit-up condition is found to be the most significant factor influencing the SM ratio. Using a Pareto diagram, the optimal condition is determined and the SM ratio is significantly improved using the optimal condition.

Measurement of Viscoelastic Constants from Multiple Phase MR Elastography Fitting Elastic Wave (탄성파를 적용한 다중 위상 MR Elastography로부터의 점탄성 정수의 측정)

  • Jung, Nam-Chae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.3
    • /
    • pp.119-129
    • /
    • 2012
  • In the medical field, the hardening of tissues is one of important informations used in diagnosis or understanding progress of disease, a quantitative measuring method of hardening is important for objective diagnosis. It has been proposed MRE(Magnetic Resonance Elastography) method that measures an index of hardening, viscoelastic properties in a noninvasive. Because the S/N ratio of MRE images go down when measuring viscoelastic properties from local wavelength and local damping factor of a propagating wave in MRE method, methods using multiple phase MRE images have been examined to decrease the effect of noise. We propose a method measuring viscoelastic properties after Fitting a function for multiple phase MRE images in this research. This proposed method has a advantage to set up arbitrarily the variation rate of a space direction of viscoelastic properties or the spatial resolution of measuring values according to changing of the noise included in images, though it applies viscoelastic wave for multiple phase MRE images. We confirmed the effectiveness of a proposed method by experiment using simulation images and experiment using silicone-gel phantom.

Analysis of Flavonoids in Concentrated Pomegranate Extracts by HPLC with Diode Array Detection

  • Lee, Jeong-Hwan;Kim, Seung-Deok;Lee, Ja-Young;Kim, Kyung-Nam;Kim, Hyun-Su
    • Food Science and Biotechnology
    • /
    • v.14 no.1
    • /
    • pp.171-174
    • /
    • 2005
  • Three flavonoid compounds - quercetin, luteolin, and kaempferol - were analyzed from two commercially available concentrated pomegranate extracts produced in Turkey and Italy, respectively. The samples were freeze-dried and hydrolyzed by 0.4 M hydrochloric acid in 50% ethanol at $80^{\circ}C$. HPLC (high-performance liquid chromatography) with DAD (diode array detection) at a wavelength of 260 nm was used for the detection of the three flavonoids. The detection limits of the three compounds were in hundreds of picograms and the signal-to-noise ratio ranged from 4 to 5: quercetin: >308 pg, s/n=4.0; luteolin: >262 pg, s/n=4.5; kaempferol: >688 pg, s/n=5.0. Quercetin, but not luteolin and kaempferol, was detected in the both pomegranate extracts. The concentrations of quercetin were $49.7\;{\mu}g/g$ and $27.7\;{\mu}g/g$ in the two pomegranate extracts made in Turkey and Italy, respectively.

Application of Mahalanobis Taguchi System for Analysis of Multivariate System (Mahalanobis Taguchi System을 이용한 다변량 시스템의 해석에 관한 연구)

  • Hong, Jeong-Eui;Kim, Yong-Beom
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2005.11a
    • /
    • pp.300-310
    • /
    • 2005
  • Mahalanobis Taguchi System (MTS) is developed by Genishi Taguchi as a part of his quality engineering methodology. The basic idea of Taguchi's quality engineering is looking for the way of effectiveness of analyzing multivariate system. In the MTS, with the standardized variables of healthy normal data, Mahalanobis Distance(MD) calculated and that can be discriminate between normal and abnormal objects. If this discrimination process is successful, next step is optimization which is try to reduce number of attributes by neglecting less effective attributes to MD. Orthogonal Array (OA) and Signal to Noise ratio (S/N) are used to evaluate the amount contribution of each attribute to the MD. Wisconsin Breast Cancer study, from machining learning repository at University of California at Irvine, used for examining the discriminant ability of MTS.

  • PDF