• 제목/요약/키워드: Signal-to-Noise(S/N) Ratio

검색결과 187건 처리시간 0.031초

DLTS 시스템에서의 신호처리에 관한 연구 (A Study on the Data Analysis Systems in Deep Level Transient Spectroscopy)

  • 임한조;이우용;최연익;정상구;김현남
    • 대한전자공학회논문지
    • /
    • 제23권1호
    • /
    • pp.120-125
    • /
    • 1986
  • Data analysis methods in lock-in amplifier based DLTS systems were discussed with regards to the signal-to-noise ratio and improvement of resolution of DLTS spectrum. The DLTS system based on wideband two-phase lock-in amplifier is shown to be the most preferabe for the studies in deep levels of low concentration. A single-temperature scanning DLTS methods in lock-in amplifier based system with the improved sensitivity is proposed. The method is tested on the characterization of deep levels in n-GaAs.

  • PDF

검사 조건 제어와 반복 재구성의 조합을 이용한 흉부 CT의 선량 저감화 방안 (Dose Reduction Method for Chest CT using a Combination of Examination Condition Control and Iterative Reconstruction)

  • 김상현
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1025-1031
    • /
    • 2023
  • 저선량흉부 CT (Low Dose chest CT, LDCT)에서 Scout 관전압을 변화시키고 scan parameter인 자동노출제어장치(Auto Exposure Control, AEC)와 적응식 반복재구성기법(Adaptive Statistical Iterative Reconstruction, ASIR)등을 적용하여 최적의 프로토콜을 찾음으로써 방사선 피폭선량과 화질을 평가하고자 하였다. Scout 관전압을 80, 100, 120, 140 kV로 변화시키며 LDCT 프로토콜로 5회 반복 측정 후 선량을 비교하기 위해 장비에서 제공된 Dose report를 이용하여 연구 목적에 적합한 관전압을 선택하였다. 120 kV, 30 mAs의 조건으로 기본 LDCT 촬영한 후, 이 조건에 ASIR 50%를 적용하였으며 신호대잡음비와 대조도대잡음비를 평가하기 위해 배경의 노이즈를 측정하였다. 선량 비교를 위해 장비에서 제공되는 CTDIvol과 선량길이곱(Dose length product, DLP)를 식을 이용하여 비교 분석하였다. 그 결과 S140 + LDCT + ASIR 50 + AEC를 적용한 프로토콜에서 고식적인 LCDT보다 방사선 피폭선량을 감소시키고 영상의 질을 향상시켰으며 최적의 프로토콜을 얻을 수 있었으며 LDCT는 매 검사 시 필요 이상의 피폭선량이 우려되기 때문에 적절한 Parameter를 적용하는 것이 중요하며, 향후 LDCT를 이용한 건강검진에서 국민의 건강에 이바지 하는데 긍정적인 요인으로 작용될 것으로 사료된다.

Effect of Cationization Agent Concentration on Glycan Detection Using MALDI TOF-MS

  • Kim, Inyoung;Shin, Dongwon;Paek, Jihyun;Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • 제8권1호
    • /
    • pp.14-17
    • /
    • 2017
  • The effect of cationization agent concentration on glycan detection via matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was investigated using $Na^+$ ions in the form of NaCl as the cationization agent. NaCl solution concentrations ranging from 1 mM to 1 M were investigated. Glycans from ovalbumin were mixed with the cationization agent solution and the 2,5-dihydroxybenzoic acid (2,5-DHB) matrix solution in a volume ratio of 1:1:1. The resulting mixture was loaded onto the MALDI plate. Two MALDI-TOF MS instruments (Voyager DE-STR MALDI-TOF MS and Tinkerbell RT MALDI-TOF MS) were used for detection of glycans. The best detection, in terms of the number of identified glycans, the peak intensity, and the signal-to-noise (S/N) ratio, was obtained with NaCl concentrations of 0.01-0.1 M for both MALDI-TOF MS instruments.

E, F, G 밴드 디지털 주파수 측정기에 대한 연구 (A Study on Digital Frequency Discriminator (DFD) Operating in E, F, and G Band)

  • 유윤섭;김은실;이찬호;안현관;양홍선;임중수
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.149-150
    • /
    • 2006
  • In this paper, design, simulation, fabrication method, and measured results of a digital frequency discriminator(DFD) operating in E, F, and G band are introduced. We describe the direct conversion scheme(DCS) with microwave integrated-circuit(MIC) developed for the small-area and high-speed system. When the input signal is the pulse with a pulse width of 100 ns, accuracy of frequencies measured by the DFD has 1.335 MHz RMS at no noise and 2.64 MHz RMS at signal-to-noise(S/N) ratio within 3 dB in E, F, and G band, which nearly satisfy the specification of 2.5 MHz RMS.

  • PDF

Straylight analysis for preliminary filter and baffle design for New Generation GOCI

  • Oh, Eun-Song;Ahn, Ki-Beom;Jung, Kil-Jae;Ryu, Dong-Ok;Kim, Sug-Whan
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2010년도 한국우주과학회보 제19권1호
    • /
    • pp.25.4-26
    • /
    • 2010
  • We present a three-mirror anastigmat(TMA) optical system for New Generation GOCI. In order to reduce the ghost optimized filter and baffle. By using carefully chosen antireflective coating and tilted filter angle, we fulfilled the design SNR requirement of 1500. We then designed a new entrance baffle and an internal baffle capable of producing the ghost ratio better than 0.01% of the nominal signal. The entrance baffle limits FOV to $0.75^{\circ}$ (E/W) $\times$ $0.60^{\circ}$ (S/N), and prevents the system from strong sun illumination, and the internal baffle prevents stray and scattered ray from entering into the telescope cavity. From these filter and baffle design, we confirmed that the instrument signal to noise ratio can be met with the current conceptual opto-mechanical design.

  • PDF

핵연료집합체 기계적특성 시험시설 구축과 기능시험 (Construction and Functional Tests of Fuel Assembly Mechanical Characterization Test Facility)

  • 이강희;강흥석;윤경호;양재호
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.11-16
    • /
    • 2016
  • Fuel assembly's mechanical characterization test facility (FAMeCT) in KAERI was constructed with upgraded functional features such as increased loading capacity, underwater vibration testing and severe earthquake simulation for extended fuel design guideline. This facility is designed and developed to provide out-pile fuel data for accident analysis model and fuel licensing. Functional tests of FAMeCT were performed to confirm functionality, structural integrity, and validity of newly-built fuel assembly mechanical test facility. Test program includes signal check of data acquisition system, load delivering capacity using real-sized fuel assemblies and a standard loading cylindrical rigid specimen. Fuel assembly's lateral bending test was carried out up to 30 mm of pull-out displacement. Limit case axial compression loading test up to 33 kN was performed to check structural integrity of UCPS (Upper Core Plate Simulator) support frame. Test results show that all test equipment and measurement system have acceptable range of alignment, signal to noise ratio, load carrying capacity limit without loss of integrity. This paper introduces newly constructed fuel assembly's mechanical test facility and summarizes results of functional test for the mechanical test equipment and data acquisition system.

Parameter Design and Analysis for Aluminum Resistance Spot Welding

  • Cho, Yong-Joon;Li, Wei;Hu, S. Jack
    • Journal of Welding and Joining
    • /
    • 제20권2호
    • /
    • pp.102-108
    • /
    • 2002
  • Resistance spot welding of aluminum alloys is based upon Joule heating of the components by passing a large current in a short duration. Since aluminum alloys have the potential to replace steels fur automobile body assemblies, it is important to study the process robustness of aluminum spot welding process. In order to evaluate the effects of process parameters on the weld quality, major process variables and abnormal process conditions were selected and analyzed. A newly developed two-stage, sliding-level experiment was adopted fur effective parameter design and analysis. Suitable ranges of welding current and button diameters were obtained through the experiment. The effects of the factors and their levels on the variation of acceptable welding current were considered in terms of main effects. From the results, it is concluded that any abnormal process condition decreases the suitable current range in the weld lobe curve. Pareto analysis of variance was also introduced to estimate the significant factors on the signal-to-noise (S/N) ratio. Among the six factors studied, fit-up condition is found to be the most significant factor influencing the SM ratio. Using a Pareto diagram, the optimal condition is determined and the SM ratio is significantly improved using the optimal condition.

탄성파를 적용한 다중 위상 MR Elastography로부터의 점탄성 정수의 측정 (Measurement of Viscoelastic Constants from Multiple Phase MR Elastography Fitting Elastic Wave)

  • 정남채
    • 융합신호처리학회논문지
    • /
    • 제13권3호
    • /
    • pp.119-129
    • /
    • 2012
  • 의료분야에서 조직의 경화는 진단 또는 질환의 진행상황의 파악에 이용되는 중요한 정보의 한 가지이며, 객관적인 진단을 위해서는 경화의 정량적 계측법이 중요하다. 경화의 지표인 점탄성 정수를 비침습적으로 계측하는 방법으로 MRE(Magnetic Resonance Elastography) 법이 제안되고 있다. MRE 법에서는 전파파(propagating wave)의 국소 파장과 국소 감쇠율로부터 점탄성 정수를 구하는데 MRE 화상은 S/N 비가 낮아지므로, 잡음의 영향을 감소시키기 위하여 다중 위상 MRE 화상을 이용한 방법이 검토되고 있다. 본 연구에서는 다중 위상 MRE 화상에 함수를 적용하여 점탄성 정수를 측정하는 방법을 제안한다. 제안 방법은 다중 위상 MRE 화상에 점탄성파를 적용시키지만, 점탄성 정수의 공간방향으로의 변화율이나 화상에 포함된 잡음에 따라 측정값의 공간분해능을 임의적으로 설정할 수 있다는 장점이 있다. 시뮬레이션 화상을 이용한 실험과 silicone-gel phantom을 이용한 실험에 의하여 제안된 방법의 유효성을 확인하였다.

Analysis of Flavonoids in Concentrated Pomegranate Extracts by HPLC with Diode Array Detection

  • Lee, Jeong-Hwan;Kim, Seung-Deok;Lee, Ja-Young;Kim, Kyung-Nam;Kim, Hyun-Su
    • Food Science and Biotechnology
    • /
    • 제14권1호
    • /
    • pp.171-174
    • /
    • 2005
  • Three flavonoid compounds - quercetin, luteolin, and kaempferol - were analyzed from two commercially available concentrated pomegranate extracts produced in Turkey and Italy, respectively. The samples were freeze-dried and hydrolyzed by 0.4 M hydrochloric acid in 50% ethanol at $80^{\circ}C$. HPLC (high-performance liquid chromatography) with DAD (diode array detection) at a wavelength of 260 nm was used for the detection of the three flavonoids. The detection limits of the three compounds were in hundreds of picograms and the signal-to-noise ratio ranged from 4 to 5: quercetin: >308 pg, s/n=4.0; luteolin: >262 pg, s/n=4.5; kaempferol: >688 pg, s/n=5.0. Quercetin, but not luteolin and kaempferol, was detected in the both pomegranate extracts. The concentrations of quercetin were $49.7\;{\mu}g/g$ and $27.7\;{\mu}g/g$ in the two pomegranate extracts made in Turkey and Italy, respectively.

Mahalanobis Taguchi System을 이용한 다변량 시스템의 해석에 관한 연구 (Application of Mahalanobis Taguchi System for Analysis of Multivariate System)

  • 홍정의;김용범
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2005년도 추계학술대회
    • /
    • pp.300-310
    • /
    • 2005
  • Mahalanobis Taguchi System (MTS) is developed by Genishi Taguchi as a part of his quality engineering methodology. The basic idea of Taguchi's quality engineering is looking for the way of effectiveness of analyzing multivariate system. In the MTS, with the standardized variables of healthy normal data, Mahalanobis Distance(MD) calculated and that can be discriminate between normal and abnormal objects. If this discrimination process is successful, next step is optimization which is try to reduce number of attributes by neglecting less effective attributes to MD. Orthogonal Array (OA) and Signal to Noise ratio (S/N) are used to evaluate the amount contribution of each attribute to the MD. Wisconsin Breast Cancer study, from machining learning repository at University of California at Irvine, used for examining the discriminant ability of MTS.

  • PDF