• Title/Summary/Keyword: Signal-injection

Search Result 396, Processing Time 0.03 seconds

Diagnosis of Iliotibial Band Friction Syndrome and Ultrasound Guided Steroid Injection

  • Hong, Ji Hee;Kim, Ji Sub
    • The Korean Journal of Pain
    • /
    • v.26 no.4
    • /
    • pp.387-391
    • /
    • 2013
  • A 64-year-old woman visited our pain clinic with the pain of right lateral side of thigh for one year. Her pain always started from knee and was radiated to buttock area when symptom was severe. She showed significant tenderness at knee lateral side and local tightness at lateral thigh. Magnetic resonance image of the knee was performed and we could identify high signal intensity of iliotibial band through coronal and axial view. In spite of medication and physical stretching exercise of iliotibial band for one month, she did not show any improvement of pain. To alleviate her symptom, ultrasound guided local corticosteroid injection targeting beneath the iliotibial band was performed. After the procedure, the reduction of pain was significant and there was no need for further management.

An experimental study on the impingement spray of a common-rail diesel injector (2) -atomization characteristics- (커먼레일식 디젤 인젝터의 충돌 분무에 대한 실험적 연구(2) -미립화 특성-)

  • Lee, C.S.;Park, S.W.;Seo, S.H.
    • Journal of ILASS-Korea
    • /
    • v.8 no.3
    • /
    • pp.19-26
    • /
    • 2003
  • In this study, experimental study on atomization characteristics of the fuel spray impinging on the wall was at different wall distances and angles of wall inclination. The fuel injection system was composed based on the common rail system. and the injection signal was synchronized by the delay generator. The atomization characteristics of the injected spray were analyzed in terms of the SMD and velocities which were measured by using the phase Doppler particle analyzer system. It is revealed that the free spray is atomized actively above 50mm form the injector tip. In the cases of the impinged spray, the 5MD and velocity of the impinged spray are smaller than those of the free spray. The impinged spray has the maximum near the 35mm of the radial distance from the injector axis, and the atomization performance is enhanced with the decrease of the wall distance.

  • PDF

On the new mold structure with multi-point gate for filling-balance mold (사출성형시 불균형 충전에 관한 다구찌 실험계획법을 이용한 성형공정의 최적화)

  • Hong, Youn-Suk;Han, Dong-Hyup;Jeong, Yeong Deug
    • Design & Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.13-16
    • /
    • 2007
  • Almost all injection molds have multi-cavity runner system for mass production, which are designed with geometrically balanced runner system in order to accomplish filling balance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalance have been observed. Filling imbalance could be decreased by modifying processing conditions such as injections rate, mold temperature, injection pressure, melt temperature that are related to shear, viscosity. In this study, a series of experiment was conducted to investigate filling imbalance variation when modifying runner layout and polymer and to determine which processing condition influences as the primary cause of filling imbalance in geometrically balanced runner system.

  • PDF

Actuaots based on Single Walled Carbon Nanotube (단일벽 탄소 나노튜브의 엑츄에이터 응용)

  • Oh, Young-Seok;Cao, Cheng-Fan;Choi, Jae-Boong;Kim, Young-Jin;Baik, Seung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1387-1390
    • /
    • 2006
  • Several actuation mechanism for carton nanotubes has teen reported recently, including actuation by double-layer charge injection and ac voltages applyied to multiple electrodes. Carbon nanotube actuator based on double layer charge injection work well in electrolyte at low voltage. AC dielectrophoresis based on four electrode geometry demonstrated carton nanotubes in solution phase can be oriently manipulated by dielectrophoresis. From this point of view, and in regard to their performance, bucky paper actuator may alternate natural muscle. also, applied AC signal with appropriate magnitude and frequency together with four electrode arrangement has potential to realize nanotube electrokinetics.

  • PDF

Initial Rotor Position Estimation of an IPMSM Based on Least Squares Approximation with a Polarity Identification (극성 판별이 가능한 최소 제곱법 기반의 IPMSM 회전자 초기 위치 추정)

  • Kim, Keon Young;Bak, Yeongsu;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.1
    • /
    • pp.72-75
    • /
    • 2018
  • An initial rotor position estimation method is proposed in this study for an interior permanent-magnet synchronous motor without a resolver or an absolute encoder. This method uses least squares approximation to estimate the initial rotor position. The magnetic polarity is identified by injection of short pulses. The proposed estimation process is robust because it does not require complex signal processing that depends on the performance of a digital filter. In addition, it can be applied to various servo systems because it does not require additional hardware. Experimental results validate the effectiveness of the proposed method using a standard industrial servomotor with interior-permanent magnets.

Voltammetric Analysis on a Disposable Microfluidic Electrochemical Cell

  • Chand, Rohit;Han, Dawoon;Kim, Yong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1175-1180
    • /
    • 2013
  • A microfabricated electrochemical cell comprising PDMS-based microchannel and in-channel gold microelectrodes was fabricated as a sensitive and a miniature alternative to the conventional electroanalytical systems. A reproducible fabrication procedure enabled patterning of multiple microelectrodes integrated within a PDMS-based fluidic network. The active area of each electrode was $200{\mu}m{\times}200{\mu}m$ with a gap of $200{\mu}m$ between the electrodes which resulted in a higher signal to noise ratio. Also, the PDMS layer served the purpose of shielding the electrical interferences to the measurements. Analytes such as potassium ferrocyanide; amino acid: cysteine and nucleoside: guanosine were characterized using the fabricated cell. The microchip was comparable to bulk electrochemical systems and its applicability was also demonstrated with flow injection based rapid amperometric detection of DNA samples. The device so developed shall find use as a disposable electrochemical cell for rapid and sensitive analysis of electroactive species in various industrial and research applications.

Implementation and modeling of wavelength tunable all-optical clok recovery using a semiconductor-fiber ring laser (고리형 반도체-광섬유 레이저를 이용한 파장 가변형 전광 동기 신호 재생 구현과 모델링)

  • 유봉안;김동환;이병호
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.3
    • /
    • pp.166-170
    • /
    • 2000
  • A wavelength tunable all-optical clock recovery using a semiconductor optical amplifier in a fiber ring cavity is proposed and demonstrated at the wavelength of 1530 nm to 1570 nm. A synchronized optical pulse train is recovered from 10 Gbps and 30 Gbps randomly generated optical pulse streams with injection locking technique. Also, the system responses to the perturbation and the input average power variation are analyzed by a large-signal model based on time-domain travelling wave equation. ation.

  • PDF

WDM-PON Based on Wavelength Locked Fabry-Perot LDs

  • Lee, Chang-Hee;Mun, Sil-Gu
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.326-336
    • /
    • 2008
  • A WDM-PON has been considered as an ultimate solution for access networks. However, there were many technical and practical issues for commercial deployment. These issues were solved with wavelength locked F-P LD and the WDM-PONs employing this optical source were commercialized. These WDM-PON systems have been deployed in Korea, Europe, and US. We reviewed wavelength locking technology and WDM-PON achievements. When we inject spectrum sliced broadband light into an F-P LD, the multimode output is changed to a quasi single mode. Then, we can use the single mode light for WDM signal transmission. The broad spectral gain of the semiconductor gain medium enables a color-free operation of WDM-PON, i.e., an identical ONT can be used for each user. The wavelength locking properties depend on many parameters, especially alignment of injection wavelength to a lasing mode, passband profile of AWG and front facet reflectivity of F-P LD. However, these dependencies can be reduced by proper design of the laser and the injection bandwidth. Thus, WDM-PON systems have been achieved with color-free operation.

Analysis of $Si_3N_4$ Ultra Fine Powder Using High-pressure Acid Digestion and Slurry Injection in Inductively Coupled Plasma Atomic Emission Spectrometry

  • Kim, K.H.;Kim, H.Y.;Im, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.2
    • /
    • pp.159-163
    • /
    • 2001
  • Si3N4 powder has been analyzed by inductively coupled plasma atomic emission spectrometry (ICP-AES). The sample was dissolved by high-pressure acid digestion with HF, H2SO4 (1+1), and HNO3 mix ture. This technique is well suited for the impurity analysis of Si3N4 because the matrix interference is eliminated. A round-robin samples trace elements, such as Ca, W, Co, Al, Fe, Mg, and Na, were determined. For the direct analysis, slurry nebulization of 0.96 mm Si3N4 powder also has been studied by ICP-AES. Emission intensities of Fe were measured as ICP operational conditions were changed. Significant signal difference between slurry particles and aqueous solution was observed in the present experiment. Analytical results of slurry injection and high-pressure acid digestion were compared. For the use of aqueous standard solution for calibration, k-factor was determined to be 1.71 for further application.

Evaluation of Near-infrared Fluorescence-conjugated Peptides for Visualization of Human Epidermal Receptor 2-overexpressed Gastric Cancer

  • Jeong, Kyoungyun;Kong, Seong-Ho;Bae, Seong-Woo;Park, Cho Rong;Berlth, Felix;Shin, Jae Hwan;Lee, Yun-Sang;Youn, Hyewon;Koo, Eunhee;Suh, Yun-Suhk;Park, Do Joong;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.21 no.2
    • /
    • pp.191-202
    • /
    • 2021
  • Purpose: A near-infrared (NIR) fluorescence imaging is a promising tool for cancer-specific image guided surgery. Human epidermal receptor 2 (HER2) is one of the candidate markers for gastric cancer. In this study, we aimed to synthesize HER2-specific NIR fluorescence probes and evaluate their applicability in cancer-specific image-guided surgeries using an animal model. Materials and Methods: An NIR dye emitting light at 800 nm (IRDye800CW; Li-COR) was conjugated to trastuzumab and an HER2-specific affibody using a click mechanism. HER2 affinity was assessed using surface plasmon resonance. Gastric cancer cell lines (NCI-N87 and SNU-601) were subcutaneously implanted into female BALB/c nu (6-8 weeks old) mice. After intravenous injection of the probes, biodistribution and fluorescence signal intensity were measured using Lumina II (Perkin Elmer) and a laparoscopic NIR camera (InTheSmart). Results: Trastuzumab-IRDye800CW exhibited high affinity for HER2 (KD=2.093(3) pM). Fluorescence signals in the liver and spleen were the highest at 24 hours post injection, while the signal in HER2-positive tumor cells increased until 72 hours, as assessed using the Lumina II system. The signal corresponding to the tumor was visually identified and clearly differentiated from the liver after 72 hours using a laparoscopic NIR camera. Affibody-IRDye800CW also exhibited high affinity for HER2 (KD=4.71 nM); however, the signal was not identified in the tumor, probably owing to rapid renal clearance. Conclusions: Trastuzumab-IRDye800CW may be used as a potential NIR probe that can be injected 2-3 days before surgery to obtain high HER2-specific signal and contrast. Affibody-based NIR probes may require modifications to enhance mobilization to the tumor site.