• 제목/요약/키워드: Signal stability

검색결과 899건 처리시간 0.041초

전력선 통신을 이용한 난방용 솔레노이드밸브 제어에 관한 연구 (A Study on the Control of Solenoid Valve for Heating by using Power Line Communication (PLC))

  • 신관우;김용태;이윤섭
    • 제어로봇시스템학회논문지
    • /
    • 제9권8호
    • /
    • pp.647-650
    • /
    • 2003
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance, and selective possibility of frequency property. We designed the boiler temperature control system unit by using the PLC modem. We can avoid unnecessary heating of separate temperature control unit, and save the cost accordingly control stability of the proposed system is proven through the experiment.

변류기 포화 곤단 알고리즘으로 억제된 모선보호용 비율 전류차동 계전방식 (A Percentage Current Differential Relaying Algorithm for Bus Protection Blocked by a CT Saturation Detection Algorithm)

  • 강용철;윤재성
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권1호
    • /
    • pp.44-49
    • /
    • 2003
  • This paper describes a percentage current differential relaying algorithm for bus protection blocked by a CT saturation detection algorithm. The detection algorithm blocks the output of a current differential relay only if a differential current is caused by CT saturation in the case of an external fault. Moreover, if a current differential relay operates faster than the detection algorithm, the blocking signal is not ignited. On the other hand. if the detection algorithm operates faster than a current differential relay, the output of the relay is blocked. The results of the simulation show that the proposed algorithm can discriminate internal faults from external faults ever when a CT is saturated in both cases. This paper concludes by implementing the algorithm into the TMS320C6701 digital signal processor. The results of hardware implementation are also satisfactory The algorithm can not only increase the sensitivity of the current differential relay but Improve the stability of the relay for an external faults.

LLC 공진형 컨버터의 소신호 모델링 분석 및 실험적 검증 (Small Signal Modeling Analysis and Experimental Verification of LLC Resonant Converter)

  • 김진우;이태영;조영훈;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.365-366
    • /
    • 2017
  • LLC resonant DC-DC converter is widely used in many kinds of applications such as battery energy storage systems, wireless power transfer and high voltage power supply. It is because of characteristics like high efficiency, power density, isolation, wide power level and stability enhancement at high switching frequency. Small signal modeling helps to design controller of the converter by approximating the behavior of nonlinear system with linear state equations. This paper presents comparison between small signal modeling analysis and experimental results of LLC resonant converter.

  • PDF

The Program Development for Real-Time Monitoring And Control of RF Output

  • Shin, Gang-wook;Hong, Sung-Tak;Yang, Jae-Rheen
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.69.6-69
    • /
    • 2001
  • The SSPA makes the power level of EIRP up to 16W, and compensates for temperature to the SSPA´s maximum stability. The up and the down converters are dually conversed like as individual synthesizers for selecting of independent transmit-receive transponder. The function of the up-converter is to convert the 70MHz IF signal modulated in the indoor unit modem into a 14.0 ∼ 14.5 GHz Ku-band up-link signal to be sent to the antenna. The down-converter converts the 12.25 ∼ 12.75 GHz Ku-band down-link signal or a trouble malfunction of SSPA may be a fatal factor to operation of the whole satellite communication network. Therefore, this study developed the remote monitoring and control program to monitor the SSPA´s status before the problem occurs for stable operation of the system. This software ...

  • PDF

A New Negative Impedance Stabilizing Control Technique for Switching Power Supplies with Constant Power Loads

  • Emadi A.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.276-280
    • /
    • 2001
  • In this paper, an approach to the design of negative impedance stabilizing controllers for PWM DC/DC converters that are used in DC switching. power supplies with constant power loads is presented. The control approach is based on the feedback linearization technique. Because of the negative impedance destabilizing characteristics of constant power loads, classical linear control methods have stability limitations around the operating points. However, the proposed stabilizing technique improves large-signal stability and dynamic responses. The proposed controllers are simulated and their responses under different operations are studied. Stability of the control technique is also verified using the second theorem of Lyapunov.

  • PDF

철도 노반 구축물의 광섬유 센서를 활용한 보안시스템에 관한 연구 (Study for security system of Railroad bed structure using optical fiber)

  • 김성원;송억영;배윤;황성만
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.153-158
    • /
    • 2004
  • The security system using optical fiber is a system, circulating infrared rays laser pulse on the optical fiber which is attached on the security fence to prevent invasion, which can show invasion position with visible and audible signal on the situation monitor if an invader cut or pull the security fence with minuteness of 10m. The optical fiber can be also applied for the bed structure stability monitoring system of high speed train as well as security system. To apply this system for high speed railroad bed structures, this system will give an alarm if it detect excessive tension, shrinkage, deflection which is beyond the limit of structure, that will prevent serious railroad accident. In this paper, we like to propose that applying this system for security and structure stability can improve confidence and stability on operation of railways

  • PDF

A New Approach to Servo System Design in Hard Disk Drive Systems

  • Kim, Nam-Guk;Choi, Soo-Young;Chu, Sang-Hoon;Lee, Kang-Seok;Lee, Ho-Seong
    • 정보저장시스템학회논문집
    • /
    • 제1권2호
    • /
    • pp.137-142
    • /
    • 2005
  • In this paper, we propose a new servo system design strategy to reduce the position error signal(PES) and track mis-registration(TMR) in magnetic disk drive systems. The proposed method provides a systematic design procedure based on the plant model and an optimal solution via an optimization with a 'Robust Random Neighborhood Search(RRNS)' algorithm. In addition, it guarantees the minimum PES level as well as stability to parametric uncertainties. Furthermore, the proposed method can be used to estimate the performance at the design stage and thus can reduce the cost and time for the design of the next generation product. The reduction of PES as well as robust stability is demonstrated by simulation and experiments.

  • PDF

A Controller Design for a Stability Improvement of an On-Board Battery Charger

  • Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.951-958
    • /
    • 2013
  • This paper proposes the controller design for a stability improvement of an on-board battery charger. The system is comprised of a power factor correction (PFC) circuit and phase shift full-bridge DC-DC converter. The PFC circuit performs the control of the DC-link voltage and the input power factor. The DC-DC converter regulates the voltage and the current in the battery using the DC-link voltage. This paper proposes the design method of PI controller for the PFC circuit using a small signal model. The analysis and design of a type-three controller for the DC-DC converter is also presented. A simulation and experiment has been performed on the on-board battery charger and their results are presented to verify the validity of the proposed system.