• Title/Summary/Keyword: Signal mapping

Search Result 341, Processing Time 0.022 seconds

An Efficient Constellation Rearrangement for HARQ with 64QAM (64QAM 변조 방식의 HARQ 전송을 위한 효율적인 성상 재배열 방법)

  • Park, Won-Seok;Cho, Chung-Ki;Kim, Jong-Hwan;Kim, Sang-Hyo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.6
    • /
    • pp.14-21
    • /
    • 2011
  • In this paper, we propose an efficient symbol mapping method based on LLR (log-likelihood ratio) statistic for HARQ employing CoRe (constellation rearrangement) with 64QAM. The signal constellations for 64QAM with limited number of retransmissions are selected by the proposed mapping rule. Then we determine the transmission order of selected constellations. The proposed scheme reduces the performance deviation between transmit symbols so as to improve the system performance. Through simulation results, the proposed and existing CoRe mapping methods are compared with respect to error rate and throughput in MIMO-OFDM system over fading channel and we confirm the applicability of the proposed scheme in practical wireless communications environment.

A design of an improved GMSK quadrature modulator for digital cellular system (디지털 셀룰라 시스템을 위한 개선된 GMSK 직교 변조기의 설계)

  • 송영준;한영열
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.32-41
    • /
    • 1996
  • We propose the improved GMSK (gaussian-filtered minimum shift keying) quadrature modulator using the FIR(finite impulse response )filter whose coefficients are obtained form the differnce of phase response, and design its ASIC (applicaton specific integrated circuit) which can be used for GSM (global system for mobile communication) digital cellular system and DCS 1800 (digital cellular system at 1800MHz) personal communication system. Input data become quantized I and Q channel 10 bit signal through cosine and sine ROM mapping after being filtered by the FIR filter whose normalized bandwidth is 0.3 and designed by considering intersymbol interference as well as sampling ratio. These two signals become the GMSK modulated I and Q channel signal through DAC (digital-to-analog converter) and 7th order analog chebyshev LPF(low pass filter) respectively. The difference between the ideal analog signal and its digitized signal is analyzed in terms of sampling noise, quantization noise, truncation noise and coefficient noise. And the effect of the LPF following the DAC is considered. The ASIC design of the GMSK quadrature modulator is also confirmed by an experiment.

  • PDF

Development of ECG Monitoring System on Mobile Platform (모바일 기반의 심전도 모니터링 시스템 개발)

  • Kim M.H.;Yoon J.H.;Lee T.Y.;Lee S.R.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.265-266
    • /
    • 2006
  • In this paper, the ECG monitoring system on mobile platform was proposed, which is very useful to gather, storage and diagnose ECG signal. The existing ECG monitoring system is for indoor environment but this system is for outdoor environment, especially for automobile system. The developed system consisted of data logger using microprocessor and data server fur diagnosis ECG signal. We develop the data acquisition system hardware and data monitoring system for ECG signal.

  • PDF

Comparison of Tropospheric Signal Delay Models for GNSS Error Simulation (GNSS 시뮬레이터 오차생성을 위한 대류층 신호지연량 산출 모델 비교)

  • Kim, Hye-In;Ha, Ji-Hyun;Park, Kwan-Dong;Lee, Sang-Uk;Kim, Jae-Hoon
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.2
    • /
    • pp.211-220
    • /
    • 2009
  • As one of the GNSS error simulation case studies, we computed tropospheric signal delays based on three well-known models (Hopfield, Modified Hopfield and Saastamoinen) and a simple model. In the computation, default meteorological values were used. The result was compared with the GIPSY result, which we assumed as truth. The RMS of a simple model with Marini mapping function was the largest, 31.0 cm. For the other models, the average RMS is 5.2 cm. In addition, to quantify the influence of the accuracy of meteorological information on the signal delay, we did sensitivity analysis of pressure and temperature. As a result, all models used this study were not very sensitive to pressure variations. Also all models, except for the modified Hopfield model, were not sensitive to temperature variations.

Enhancement of SNR Characteristics in Ultrasound Doppler Color Flow Mapping (초음파 도플러 컬러 유동 사상에서 신호 대 잡음비 특성의 향상)

  • Kwon, Sung-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2261-2266
    • /
    • 2011
  • Being the most widely used in ultrasound Doppler color flow mapping, the Kasai algorithm, also known as lag-1 autocorrelation method, is capable of estimating the Doppler mean frequency relatively accurately with a modest amount of computation. Particularly in the case of imaging deep lying areas, however, its performance suffers due to low signal-to-noise ratios. The purpose of this paper is to propose a dealiased lag-2 autocorrelation method which is superior to the Kasai algorithm even at low signal-to-noise ratios and to compare their performances through simulations. The proposed algorithm is found to be better by about 2 to 3 dB than the Kasai algorithm in terms of Doppler mean frequency estimation error in the presence of measurement noise.

Restoration of 3-Dimensional Surface Based on Binocular Stereo Vision (양안 입체시에 의한 3차원 표면의 복원)

  • Jung, Nam-Chae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.6 no.3
    • /
    • pp.112-119
    • /
    • 2005
  • In this paper, a model of neural circuit was proposed, which abstracts the depth information in two images gotten from right and left retinas. The proposed neural circuit corresponds to binocular stereo vision based on psychologic and physiological knowledge, and we examine a restoration method of three-dimensional surface. In case of drawing a disparity based on characteristics of images, we can not abstract the depth information correctly if resemblant characteristics are repeated on the boundary region of an object. A binocular disparity is decided in a model of neural circuit by abstraction, synthesis, and correction of a disparity. And we propose a method which restores three-dimensional shape by correcting a depth information, and also restores a three-dimensional surface by mapping a left input image on the restored three-dimensional shape. And we confirmed that the computation time for disparity abstraction can be greatly reduced through the simulation.

  • PDF

Integration Mechanism of SDL and CORBA System using Method/Signal Mapping Rules (메소드/시그널 매핑을 이용한 SDL과 CORBA 시스템의 통합 방법)

  • Paik, Eui-Hyun;Huh, Jae-Doo;Lee, Hyeong-Ho
    • The KIPS Transactions:PartA
    • /
    • v.9A no.4
    • /
    • pp.479-484
    • /
    • 2002
  • This paper presents the model that integrates an SDL system and a CORBA system using mapping rules between method and signal for developing embedded systems connected with internet. In order to support communication between the two different systems (SDL and CORBA), it is essential to secure the conversion interface between SDL communication protocol and CORBA communication protocol. In this paper, IDL is adopted for the communication interface and the conversion of the communication protocol between the two systems, and the IDL compiler automatically generates the interface for protocol interoperability. The proposed model adopts middleware on the subpart of the SDL based legacy system, and hence, supports the service on the distributed system, regardless of the environment and location of the server system.

Analysis of a TC-16ADPSK Performance for Transmitting Different Information on One Channel Simultaneously (TC-16ADPSK을 사용한 이종 정보 동시 전송용 변조방식의 성능 분석)

  • 이원석;강희훈;이성백
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.5
    • /
    • pp.71-76
    • /
    • 2000
  • A TC-16ADPSK scheme for transmitting different kinds of information simultaneously is proposed in this paper. The scheme is designed for simultaneously transmitting two kinds of Information on one channel. In signal mapping, a data of two kinds of information is used to phase modulation on Star-16APSK constellation and the other to amplitude modulation. In detection, each data independently recovers from mixing signal on each detector Therefore, we can transmit two kinds of Information on one channel can be transmitted efficiently. BER performance of the proposed scheme is analyzed on AWGN channel and Rayleigh fading channels on a computer with Matlab communication toolbox. On same SNR, the Gray code mapping has more 0.5-1.5dB coding gains than Ungerboeck's code mapping gains.

  • PDF

Sentinel lymph node mapping using tri-modal human serum albumin conjugated with visible dye, near infrared fluorescent dye and radioisotope

  • Kang, Se Hun;Kim, Seo-il;Jung, So-Youn;Lee, Seeyoun;Kim, Seok Won;Kim, Seok-ki
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.62-73
    • /
    • 2015
  • We developed an evans blue-indocyanine green-$^{99m}Tc$-human serum albumin conjugate for sentinel lymph node mapping and we describe its unique potential usage for clinical implications. This conjugate has combined the strengths of visible blue dye, near-infrared fluorescence and radioisotope into one single conjugate without any additional weakness/disadvantage. All the components of evans blue-indocyanine green-$^{99m}Tc$-human serum albumin are safe and of low cost, and they have already been clinically used. This conjugate was stable in the serum, it showed a long retention time in the lymphatic system and the lymph nodes showed a much higher signal-to-noise ratio after the conjugate was injected intradermally into the paw of mice. Both the single-photon emission computed tomography and near-infrared fluorescent images of the mice were successfully obtained at the same time as the excised sentinel lymph nodes showed blue color. The visual color, near-infrared fluorescence and gamma ray from this agent could be complementary for each other in all the steps of sentinel lymph node sampling: exploring and planning sentinel lymph node before excision with visualization of the exact sentinel lymph node location during an operation. Therefore, the triple modal agent will possibly be very ideal for sentinel lymph node mapping because of the high signal-to-noise ratio for non-invasive imaging and its complementary multimodal nature, easy preparation and safety. It is promising for clinical applications and it may have great advantages over the traditional single modal methods.

HYPERSPECTRAL IMAGERY AND SPECTROSCOPY FOR MAPPING DISTRIBUTION OF HEAVY METALS ALONG STREAMLINES

  • Choe, Eun-Young;Kim, Kyoung-Woong;Meer, Freek Van Der;Ruitenbeek, Frank Van;Werff, Harald Van Der;Smeth, Boudewijn De
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.397-400
    • /
    • 2007
  • For mapping the distribution of heavy metals in the mining area, field spectroscopy and hyperspectral remote sensing were used in this study. Although heavy metals are spectrally featureless from the visible to the short wave infrared range, possible variations in spectral signal due to heavy metals bound onto minerals can be explained with the metal binding reaction onto the mineral surface. Variations in the spectral absorption shapes of lattice OH and oxygen on the mineral surface due to the combination of heavy metals were surveyed over the range from 420 to 2400 nm. Spectral parameters such as peak ratio and peak area were derived and statistically linked to metal concentration levels in the streambed samples collected from the dry stream channels. The spatial relationships between spectral parameters and concentrations of heavy metals were yielded as well. Based on the observation at a ground level for the relationship between spectral signal and metal concentration levels, the spectral parameters were classified in a hyperspectral image and the spatial distribution patterns of classified pixels were compared with the product of analysis at the ground level. The degree of similarity between ground dataset and image dataset was statistically validated. These techniques are expected to support assessment of dispersion of heavy metal contamination and decision on optimal sampling point.

  • PDF