• Title/Summary/Keyword: Signal Evaluation

Search Result 1,910, Processing Time 0.029 seconds

Design and Evaluation of Wireless Sensor Node Application for u-Healthcare (u-헬스케어를 위한 무선센서노드 어플리케이션 구현 및 성능 평가)

  • Lee, Dae-Seok;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.518-521
    • /
    • 2007
  • The functional wireless sensor node for u-healthcare application was developed. The developed sensor node can check the abnormality of ECG in some simple software in ROM of microprocess in the sensor node. The ECG signal is one of very important health signal form human body, and wavelike signal which is sampled as a sampling frequency between 100 and 400 Hz for digitalization, so the wireless data dor ECG signal is some heavy in Zigbee communication. Thus the sensor send the ECG signal to other sensor nodes or base station when it find abnormality in ECG signal is key technology to reduce the traffic between sensor nodes in wireless sensor network for u-healthcare, The sensor node does not need to transmit ECG data all time in wireless sensor network and to server. Using these sensor nodes, the healthcare system can dramatically reduce wireless data packet overload, the power consumption of battery in the sensor nodes and thus increase the reliability of the wireless system.

  • PDF

ECG simulator design with Spartan-3 FPGA (Spartan-3 FPGA를 이용한 ECG 시뮬레이터 설계)

  • Woo, Sung-hee;Lee, Won-pyo;Ryu, Geun-teak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.834-837
    • /
    • 2015
  • In this paper, we designed the FPGA hardware-based real-time ECG simulator, which generates an analog ECG signal within the range of 0 to 5 volts and described function. The ECG signal generated by the simulator can be applied to laboratory tests, the medical device, and the calibration study in various ways. ECG signals generated by simulator are obtained with conventional 24bit quantization to generate the signal data, and they are sampled and quantized to 1kHz of the 8-bit resolution when used as actual data. The proposed simulator is implemented using xilix Spartan-3 and data are transmitted through an RS-232 between the PC and the FPGA simulator. The transmitted data are stored in the memory and the stored data are printed out with the analog ECG signal through DAC (0808). It can also control the heart rate (HR) via the two buttons level UP-DOWN. We used existing ECG input rating for the evaluation of the designed system and evaluated differential circuit for obtaining QRS waveform and the output signal. We finally could obtained proper the result.

  • PDF

Development and Basic Experiment of Active Noise Control System for Reduction of Road Noise (도로 소음 저감을 위한 능동소음제어 시스템의 개발 및 기초실험)

  • Moon, Hak Ryong;Kang, Won Pyoung;Lim, You Jin
    • International Journal of Highway Engineering
    • /
    • v.15 no.6
    • /
    • pp.41-47
    • /
    • 2013
  • PURPOSES : The purpose of this study is about noise which is generated from roads and is consist of irregular frequency variation from low frequency to various band. The existing methods of noise reduction are sound barrier that uses insulation material and absorbing material or have applied passive technology of noise reduction by devices. The total frequency band is needed to apply active noise control. METHODS : In this study applies to the field of road traffic environment, signal processing controller and various analog signal input/output, the amplifier module is based on parallel-core embedded processor designed. DSP performs the control algorithm of the road traffic noise. Noise sources in the open space performance of evaluation were applied. In this study, controller of active signal processor was designed based on the module of audio input/output and main controller of embedded process. The controller of active signal processor operates noise reduction algorithm and performance tests of noise reduction in inside and outside environment were executed. RESULTS : The signal processing controller with OMAP-L137 parallel-core processors as the center, DSP processors in the active control operations dealt with quickly. To maximize the operation speed of an object and ARM processor is external function keys and display for functions and evaluating the performance management system was designed for the purpose of the interface. Therefore the reduction of road traffic noise has established an electronic controller-based noise reduction. CONCLUSIONS : It is shown that noise reduction is effective in the case of pour tonal sound and complex tonal sound below 500Hz by appling to Fx-LMS.

A multi-layer approach to DN 50 electric valve fault diagnosis using shallow-deep intelligent models

  • Liu, Yong-kuo;Zhou, Wen;Ayodeji, Abiodun;Zhou, Xin-qiu;Peng, Min-jun;Chao, Nan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.148-163
    • /
    • 2021
  • Timely fault identification is important for safe and reliable operation of the electric valve system. Many research works have utilized different data-driven approach for fault diagnosis in complex systems. However, they do not consider specific characteristics of critical control components such as electric valves. This work presents an integrated shallow-deep fault diagnostic model, developed based on signals extracted from DN50 electric valve. First, the local optimal issue of particle swarm optimization algorithm is solved by optimizing the weight search capability, the particle speed, and position update strategy. Then, to develop a shallow diagnostic model, the modified particle swarm algorithm is combined with support vector machine to form a hybrid improved particle swarm-support vector machine (IPs-SVM). To decouple the influence of the background noise, the wavelet packet transform method is used to reconstruct the vibration signal. Thereafter, the IPs-SVM is used to classify phase imbalance and damaged valve faults, and the performance was evaluated against other models developed using the conventional SVM and particle swarm optimized SVM. Secondly, three different deep belief network (DBN) models are developed, using different acoustic signal structures: raw signal, wavelet transformed signal and time-series (sequential) signal. The models are developed to estimate internal leakage sizes in the electric valve. The predictive performance of the DBN and the evaluation results of the proposed IPs-SVM are also presented in this paper.

Performance Evaluation of an All-optical Automatic Gain-controlled Erbium-doped Fiber Amplifier for Suppression of Signal Fluctuation in Terrestrial Free-space Optical Communication Systems (자유 공간 광통신 시스템에서 신호 변동 억제를 위한 전광 자동 이득 조절 어븀 첨가 광섬유 증폭기의 성능 평가)

  • Jeong, Yoo Seok;Kim, Chul Han
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.3
    • /
    • pp.99-105
    • /
    • 2022
  • We have evaluated the performance of an all-optical automatic gain-controlled (AGC) erbium-doped fiber amplifier (EDFA) to suppress the optical signal fluctuation induced by atmospheric turbulence in terrestrial free-space optical communication systems. In our measurements, the input power into the EDFA was set to be -30 dBm and -10 dBm to operate the amplifier in the small-signal and saturation regions, respectively. The fluctuations in the optical signal were emulated with an acousto-optic modulator driven with a sinusoidal voltage. From the measured results, we have found that an all-optical AGC EDFA could suppress the optical signal fluctuation effectively, as long as the EDFA operated in the small-signal region with a high feedback amplified spontaneous emission (ASE) power.

The Case Study of High School On-demand Linear Algebra Course : Mixed Traditional and Flipped Learning Methods ans Signal Processing Applications (고등학교 주문형 강좌 선형대수 교과목 운영사례 : 전통적 방식과 플립러닝 방식의 혼합수업 형태 및 신호처리 응용)

  • Jae-Ha Yoo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.3
    • /
    • pp.147-152
    • /
    • 2023
  • This paper is a study of a linear algebra course taught in a high school on-demand course. Compared to the regular course, flipped learning was added to the course, and applications to signal processing related problems were covered in consideration of students' career aspirations. Overall, the class was a mixture of traditional lectures and flipped learning. Flipped learning was implemented twice. The flipped class consisted of pre-class, in-class and post-class. To verify the effectiveness of the course, a survey was conducted and most of the evaluation items were above 4. The topics of the flipped learning were Markov chains and least squares problem, which are very important in the field of signal processing.

Safely Evaluation on Common Grounding System for Electric Railway (전기철도의 공용접지 시스템에 대한 안정성 평가에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.298-306
    • /
    • 2002
  • We performed an safety evaluation on constructing of a common grounding system for electrical railway in view of its efficacy and technical fit. In order to compare the conventional grounding method, which has been individually conducted, with the common grounding with all ground wires connected in common to the counterpoise buried below the surface of the earth in parallel with rail, we set up scenarios with several cases of fault and load conditions in Chungbuk railway sections with the common grounding system. Based on models for railway conductors including the grounded system, line Parameters of railway power system are computed. The circuit model for power system with up and down lines, auto-transformers and railway substations is used to compute impedances of counterpoise and substation ground net. For each scenario with faults and operation conditions of railway, the induced potentials on signal and communication lines are also computed. It is shown that the common grounding for Chungbuk railway is superior experimentally to the conventional method in three respects: (1) the lower rail potentials during operation of railway in line, (2) the lower rail potentials for short-circuit faults between catenary and rail, and (3) the lower stress voltages on signal and communication lines for short-circuit or ground faults. The analysis results confirm that the grounding system for electric railway is required to be built by the common grounding and be evaluated on its safety in design.

Gait-Event Detection for FES Locomotion (FES 보행을 위한 보행 이벤트 검출)

  • Heo Ji-Un;Kim Chul-Seung;Eom Gwang-Moon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.170-178
    • /
    • 2005
  • The purpose of this study is to develop a gait-event detection system, which is necessary for the cycle-to-cycle FES control of locomotion. Proposed gait event detection system consists of a signal measurement part and gait event detection part. The signal measurement was composed of the sensors and the LabVIEW program for the data acquisition and synchronization of the sensor signals. We also used a video camera and a motion capture system to get the reference gait events. Machine learning technique with ANN (artificial neural network) was adopted for automatic detection of gait events. 2 cycles of reference gait events were used as the teacher signals for ANN training and the remnants ($2\sim5$ cycles) were used fur the evaluation of the performance in gait-event detection. 14 combinations of sensor signals were used in the training and evaluation of ANN to examine the relationship between the number of sensors and the gait-event detection performance. The best combinations with minimum errors of event-detection time were 1) goniometer, foot-switch and 2) goniometer, foot-switch, accelerometer x(anterior-posterior) component. It is expected that the result of this study will be useful in the design of cycle-to-cycle FES controller.

Evaluation of Three-Phase Actuated Operation at Diamond Interchanges (다이아몬드 인터체인지의 3현시 감응제어 평가)

  • 이상수
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.2
    • /
    • pp.149-159
    • /
    • 2002
  • The performance of two single-barrier three-phase control systems at diamond interchanges was evaluated for various traffic conditions. To emulate the actuated signal control, hardware-in-the-loop system combined with CORSIM simulation program was used. Two performance measures, average delay and total stops, were used for the evaluation process. Results showed that the two three-phase systems gave similar performance in terms of average delay, but not stops. The delay performance of each phasing system was generally dependent on the traffic pattern and ramp spacing. However, there was a distinct movement preference for each phasing system. The total stops decreased as the spacing increased, and it was the most sensitive variable that can differentiate between the two three-phase systems. It was also shown that the hardware-in-the-loop control could be a good method to overcome the limitations of current simulation technology.

Performance Evaluation of Cascade AOA Estimation Algorithm Based on Square Array Antenna (정방배열 안테나 기반 캐스케이드 도래각 추정 알고리즘 성능평가)

  • Kim, Tae-Yun;Hwang, Suk-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1053-1060
    • /
    • 2019
  • The satellite antenna for collecting information is mainly classified into reflector antenna, lens antenna, and phased array antenna. Among them, the phased array antenna with the excellent antenna pattern control performance for a multi-beam system is frequently used. Although the terrestrial signal information collection based on the satellite is not much effected geographically, it requires the accurate angle-of-arrival (AOA) information of the interesting signal. In this paper, we discuss the characteristics and the advantages/disadvantages of the antenna array shape employed in the phased array antenna. In addition, we present the Cascade AOA estimation algorithm based on a square array antenna mounted on the satellite receiver, and show the performance evaluation results through the computer simulation.