• Title/Summary/Keyword: Signal Evaluation

Search Result 1,915, Processing Time 0.023 seconds

Self-Interference Cancellation-Aided Relay Beamforming for Multi-Way Relaying Systems (다중방향 릴레이 시스템을 위한 자가간섭 소거 보조 릴레이 빔형성 기법)

  • Le, Anh Duc;Park, Jin Bae;Cho, Yong Ok;Jeong, Min A;Lee, Seong Ro;Kim, Yun Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.4
    • /
    • pp.378-386
    • /
    • 2013
  • In this paper, we propose a multi-way relaying system, in which N communicating nodes interchange their information one another by the help of a multiple-antenna non-regenerative relay station (RS). While the conventional multi-way relaying requires 2N transmission phases to complete the data exchange, the proposed system completes the mission with N phases composed of one multiple access phase and N-1 broadcast phases. For effective broadcast transmission, the proposed system pairs users for signal transmission with a new RS beamforming matrix not to interfere with the nodes of different pairs and a self-interference canceler at each node. The performance evaluation in terms of the average sum rate shows that the proposed system outperforms the conventional one with more significant gain when the number of RS antennas is comparable to the number of communicating nodes. The proposed schemes can be applicable to marine communications where the ships need to share their information with extended coverage.

Design and Performance Evaluation of M×M MIMO Transmission in ESPAR Antenna (ESPAR 안테나에서 M×M MIMO 송신방식의 설계와 성능 평가)

  • Bok, Junyeong;Lee, Seung Hwan;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.12
    • /
    • pp.1061-1068
    • /
    • 2013
  • In this paper, we propose a $M{\times}M$ beam-space multiple input multiple output (BS-MIMO) system using electronically steerable parasitic array radiator (ESPAR) antenna. Conventional MIMO method required multiple RF chains because it map the transmission signals onto multiple antennas. So, conventional MIMO system has high cost for design and high energy consumption at RF circuit. Also, It is difficult to use MIMO system in battery based mobile terminals with limited physical area. In order to solve these problems, BS-MIMO technique which map the data signal onto bases in beam space domain was proposed using ESPAR antenna with single RF chain. This paper, we design and analyze the performance of extended $M{\times}M$ BS-MIMO technique. Simulation results show that the proposed BS-MIMO system has similar BER performance compare to conventional MIMO scheme. Therefore, BS-MIMO system with single RF chain will has a low RF power consumption and low cost for RF hardware design as compared with conventional MIMO technique with multiple RF chains.

Evaluation of Relative Emission of Image Plate by Using Relative Sensitivity in Computed Radiography System (컴퓨터 방사선영상시스템에서 비감도를 이용한 영상판의 상대적 발광량 평가)

  • Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.355-361
    • /
    • 2014
  • The aim of the present study was to evaluate a relative emission of image plate (IP) in computed radiography (CR) system by using relative sensitivity in film/screen methods. The characteristic curve was obtained by using the uniform aluminum 11-step wedge penetrometer. X-ray exposure factors on radiographic digital image were 50 kVp, 10 mAs. We adjusted zero of all parameter of algorithms (MUSICA) so proximate to raw data and applied to 200 of exposure class. Modeling on relative emission of IP are used IP without fading time and IP after 4 hours, 8 hours, 12 hours, 24 hours in the respective storage after X-ray exposure. The results of this study showed that the sensitivity point density at the measuring of relative sensitivity in CR was suited pixel values of the 2000 easy to relatively measure the characteristic curve and when relative sensitivity is decreased, the amount of light emitted from the image signal for generating was also decreased. In conclusion, the proposed method of measurement of relative sensitivity can be utilized to evaluate the quantity of relative emission of IP in CR system.

Comparison of Motor Function and Skill between Stroke Patients with Cerebellar and Non-cerebellar Lesion in Sub-acute Stage

  • Kwon, Yong Hyun;Kim, Chung Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.6
    • /
    • pp.423-427
    • /
    • 2012
  • Purpose: The cerebellum is a region of brain structure that plays an important role in calibrating two different information of neural signal from descending motor commands and from ascending sensory inputs. Damage of the cerebellum shows a variety of classic motor symptoms such as postural and locomotor dysfunctions. Therefore, we tried to investigate motor function and skill in stroke patients with cerebellar lesions in sub-acute stage, and compare with these functions of patients with non-cerebellar lesions. Methods: Total twelve stroke patients with cerebellar lesion and 130 stroke patients with non-cerebellar lesions were retrospectively recruited in this study. For evaluation of motor strength, Motricity index (MI) for upper and lower limbs was tested. For measurement of motor skill function, the modified Brunnstrom classification (MBC), Manual function test (MFT), functional ambulatory category (FAC), and Barthel index were adopted. Results: In comparison of motor strength and motor skill function between two groups, statistical differences between the two groups were significantly observed only in upper MI and FAC. Although no significant differences were found in other variables, stroke patients with cerebellar lesion had higher scores in lower and total MI, MBC, and MFT, whereas they had lower scores in FAC and Barthel index. Conclusion: Our results showed that stroke patients with cerebellar lesion had greater impact on movement functions related to hand motor and walking ability in activities of daily life, compared with patients with non-cerebellar lesion, in spite of similar degree of motor function and skill between the two different lesioned-groups.

A Study on Dose Reduction Method according to Slice Thickness Change using Automatic Exposure Controller and Manual Exposure in Intervention (인터벤션에서 자동노출제어장치와 수동노출 사용 시 두께 변화에 따른 선량감소 방안 연구)

  • Hwang, Jun-Ho;Jung, Ku-Min;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.115-122
    • /
    • 2018
  • We aims to perform comparative analysis on the dose area and image qualities varying on the slice thickness when using Automatic Exposure Controller (AEC) and manual exposure; thus, it wants to suggest a measure to reduce exposure dose by setting the optimal examination condition for each slice thickness. The method was to set the thickness as Thin, Normal, and Heavy adult and evaluate the dose area, spatial resolution, low contrast resolution, Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) according to each slice thickness by using the AEC and the manual exposure controller. The dose area according to each slice thickness all increased both when using the AEC and the manual exposure. However, the manual exposure showed lower dose area product than the AEC. Spatial resolutions and low contrast resolutions were all observed to be higher than the evaluation standard. Also, the SNR and CNR of each thickness all increased when using the AEC. When using the manual exposure, SNR and CNR increased in all cases other than the Heavy Adult. Consequently, the Thin and Normal Adult showed dose reduction about 2 times when using the manual exposure controller, while ensuring the image quality. Heavy adult was able to maintain good image quality by using AEC.

A Study on the Optimum Amount of Contrast Media in Brain Angiography (뇌 혈관검사 시 적정 조영제량에 관한 연구)

  • Kim, Gyoo-Hyung;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.123-128
    • /
    • 2018
  • Recently, the use of contrast agents has been increasing as a broader range of tests and dynamic tests have become common due to the development of equipment and imaging techniques such as Multi-Detector CT. However, the side effects of using contrast agents have been reduced by the development of non-ionic contrast agents, but they are still occurring often. The purpose of this study was to propose a method to minimize the side effect of contrast agent by using the amount of contrast agent injected to the brain angiography test to suppress excessive use of contrast agent and analyze the amount of contrast agent. Patients who were prescribed Brain Angiography due to cerebrovascular disease, According to the results of the comparison of the results obtained by dividing into 4 groups of 10ml each according to the amount of contrast medium injected with contrast agent according to the BMI of the patient, BA and SNR were not different between groups, and even if the amount of contrast injection was reduced, there was no problem in the evaluation of CT angiography through 3D reconstruction. This result shows that even if the contrast medium is injected into the blood vessels of the patient first and then the contrast medium is used as the physiological saline solution, the contrast medium is reduced by 40% it can be expected to minimize.

Video Coding Method Using Visual Perception Model based on Motion Analysis (움직임 분석 기반의 시각인지 모델을 이용한 비디오 코딩 방법)

  • Oh, Hyung-Suk;Kim, Won-Ha
    • Journal of Broadcast Engineering
    • /
    • v.17 no.2
    • /
    • pp.223-236
    • /
    • 2012
  • We develop a video processing method that allows the more advanced human perception oriented video coding. The proposed method necessarily reflects all influences by the rate-distortion based optimization and the human visual perception that is affected by the visual saliency, the limited space-time resolution and the regional moving history. For reflecting the human perceptual effects, we devise an online moving pattern classifier using the Hedge algorithm. Then, we embed the existing visual saliency into the proposed moving patterns so as to establish a human visual perception model. In order to realize the proposed human visual perception model, we extend the conventional foveation filtering method. Compared to the conventional foveation filter only smoothing less stimulus video signals, the developed foveation filter can locally smooth and enhance signals according to the human visual perception without causing any artifacts. Due to signal enhancement, the developed foveation filter more efficiently transfers the bandwidth saved at smoothed signals to the enhanced signals. Performance evaluation verifies that the proposed video processing method satisfies the overall video quality, while improving the perceptual quality by 12%~44%.

Design and Evaluation of a Protection Relay for a Wind Generator Based on the Positive- and Negative-Sequence Fault Components

  • Zheng, Taiying;Cha, Seung-Tae;Kim, Yeon-Hee;Crossley, Peter A.;Lee, Sang Ho;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1029-1039
    • /
    • 2013
  • To avoid undesirable disconnection of healthy wind generators (WGs) or a wind power plant, a WG protection relay should discriminate among faults, so that it can operate instantaneously for WG, connected feeder or connection bus faults, it can operate after a delay for inter-tie or grid faults, and it can avoid operating for parallel WG or adjacent feeder faults. A WG protection relay based on the positive- and negative-sequence fault components is proposed in the paper. At stage 1, the proposed relay uses the magnitude of the positive-sequence component in the fault current to distinguish faults requiring non-operation response from those requiring instantaneous or delayed operation responses. At stage 2, the fault type is first determined using the relationships between the positive- and negative-sequence fault components. Then, the relay differentiates between instantaneous operation and delayed operation based on the magnitude of the positive-sequence fault component. Various fault scenarios involving changes in position and type of fault and faulted phases are used to verify the performance of the relay. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. Results indicate that the relay can successfully distinguish the need for instantaneous, delayed, or non-operation.

Eddy Current Bobbin Probe Design for Steam Generator Tubes in NPPs (원전 증기발생기 전열관 와전류검사 보빈탐촉자 설계)

  • Nam, Min-Woo;Lee, Hee-Jong;Jee, Dong-Hyun;Jung, Jee-Hong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.89-96
    • /
    • 2007
  • The bobbin probe examination is basic and the important method among other ECT techniques for the steam generator tube integrity assesment that is practiced during each plant outage. The bobbin probe is one of the essential components which consist of the whole ECT examination system, and provides us a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of examination probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has enormous effects on examination results. In this study, An optimal differential bobbin probe is designed for the steam generator tube inspection in nuclear power plants(NPPs). Based on the test results for electrical and ECT signal characteristics, the prototype bobbin probe satisfies all the criteria.

DWT Analysis of Scatter-Ray Due to the Changed Energy on Digital Medical Images (디지털 의료영상에서 에너지 변화에 따른 산란선의 DWT 분석)

  • Kim, Jisun;Jung, Jaeeun;Ahn, Byeoungju
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.65-74
    • /
    • 2014
  • This study extracts characteristics of signal by wavelet transform to prove that the Compton scattering, occurred by changed the energy, influenced a picture. We also analyzed the extracted data and evaluated how much the picture of scatter-rays was affected by a change of tube voltage. For this study, we wrote a program with MatLap which is engineering tool and evaluated with the program on variation of scattered-rays due to increased tube voltage. The evaluation result shows both CR and DR have frequency changes of high frequency area by tube voltage variations and it proved that Compton scattering influences the picture. In conclusion, according to this study indicates that DR is more sensitive to radiation with high energy than CR. Therefore, the research on DR detector needs to be advanced as actual condition of clinical setting is being changed to DR circumstance gradually. From the result of this study, we expect that assessment method of the image quality using MatLab Tool becomes the official assessment method and very useful method.